09-252-00416 1 15 1 14
SPECIFICATIONS
DIVISION 1 - GENERAL
L SECTION 01000 - SPECIAL CONDITION
1.04 - PROTECTION OF PROPERTY AND THE PUBLIC
A. AS A MINIMUM, PROVIDE TIGHT TEMPORARY DUST BARRIER WALL SEPARATING THE
WORK AREA FROM ADJOINING AREAS. PROVIDE HINGED 4' -0" WIDE DOOR ON A
CLOSER. PROVIDE LARGE FOOT MATS BOTH SIDES OF DOOR. ALL TEMPORARY
WALLS SHALL BE OF SOLID CONSTRUCTION UNLESS OTHERWISE NOTED.
B. PROVIDE STICKY "WALK -OFF" PADS AT EVERY ENTRANCE TO THE WORK AREA, TO
CAPTURE DUST FROM WORKMEN'S FEET. REPLACE EACH PAD DAILY OR MORE
OFTEN IF REQUIRED SO THAT THEIR EFFECTIVENESS IS MAINTAINED.
1.08-MEASUREMENTS
K A. BEFORE ORDERING ANY MATERIAL OR DOING ANY WORK, THE CONTRACTOR SHALL
VERIFY ALL MEASUREMENTS AND SHALL BE RESPONSIBLE FOR THE CORRECTNESS
OF SAME. NO EXTRA CHARGE OR COMPENSATION WILL BE ALLOWED ON ACCOUNT
OF DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND THE MEASUREMENTS
INDICATED ON THE DRAWINGS.
1.09 - EQUIPMENT FURNISHED AND INSTALLED BY THE OWNER
A, CONTRACTOR SHALL PERMIT OWNER TO PLACE AND INSTALL AS MUCH
EQUIPMENT DURING PROGRESS OF WORK AS IS POSSIBLE BEFORE COMPLETION
OF VARIOUS PARTS OF WORK.
B, DELIVERIES OF EQUIPMENT AND FURNISHINGS PURCHASED BY THE OWNER WILL
BE ORDERED TO ARRIVE ON THE PROJECT PRIOR TO SCHEDULED DATE OF
INSTALLATION.
J
C. CONTRACTOR IN ADVANCE OF PREPARING HIS PROGRESS SCHEDULE, SHALL
RECEIVE FROM THE OWNER VIA THE ARCHITECT A LIST OF ALL EQUIPMENT
PROPOSED TO BE FURNISHED AND INSTALLED BY THE OWNER. THE LIST OF
EQUIPMENT AND ITS PROPOSED INSTALLATION DATES SHALL BE REFLECTED IN
THE PROGRESS SCHEDULE WHICH SHALL BE PREPARED BY THE GENERAL
CONTRACTOR.
D. IN GENERAL, THE OWNER WILL DELIVER, UNCRATE AND POSITION EACH PIECE OF
EQUIPMENT IN ITS PROPER LOCATION, FASTENING SAME IN PLACE WHERE
REQUIRED IN ACCORDANCE WITH THE SCHEDULE. OWNER'S EQUIPMENT
SUPPLIERS SHALL BE PROVIDED WITH REASONABLE USE OF POWER AND LIGHT
NECESSARY FOR THE INSTALLATION OF THEIR WORK WITHOUT ADDITIONAL COST
TO THE TENANT.
E. GENERAL CONTRACTOR SHALL COOPERATE WITH OWNER'S EQUIPMENT
SUPPLIERS WHEN EQUIPMENT REQUIRES ATTACHMENT AND /OR UTILITY
CONNECTION TO THE BUILDING SERVICES. GENERAL CONTRACTOR AND /OR HIS
H SUBCONTRACTORS SHALL PROVIDE SAID CONNECTIONS AS A PART OF THE WORK
OF THIS CONTRACT.
1.10 - EQUIPMENT FURNISHED BY THE OWNER AND INSTALLED BY THE CONTRACTOR
A. INSTALLATION OF EQUIPMENT INDICATED TO BE FURNISHED BY THE OWNER
SHALL BE INSTALLED BY THE CONTRACTOR AND /OR HIS SUBCONTRACTORS
RESPECTIVELY, AND SHALL BE INCLUDED AS PART OF THE WORK.
B. DELIVERIES OF EQUIPMENT PURCHASED BY THE OWNER WILL BE ORDERED IN
COORDINATION WITH CONTRACTOR'S SCHEDULING SO THAT ARRIVAL OF SUCH
EQUIPMENT WILL NOT CAUSE DELAY OF THE DATE FOR SUBSTANTIAL
COMPLETION. CONTRACTOR SHALL COOPERATE IN EVERY WAY WITH THE OWNER
FOR THE SCHEDULING OF SUCH ITEMS AS MAY BE REQUIRED.
C. CONTRACTOR SHALL RECEIVE EQUIPMENT AT TAILGATE. CONTRACTOR SHALL BE
G HELD RESPONSIBLE FOR ANY BREAKAGE, DAMAGE OR MISSING ITEMS RECEIVED,
AND SHALL PROVIDE PROTECTED STORAGE UNTIL READY FOR DISTRIBUTION TO
RESPECTIVE SUBCONTRACTORS FOR INSTALLATION,
D. CONTRACTOR SHALL SECURE FROM THE OWNER ALL TECHNICAL INFORMATION
REGARDING SUCH EQUIPMENT AND SHALL PROPERLY PREPARE SERVICE
CONNECTIONS FOR SAME, INCLUDING BUT NOT LIMITED TO SPECIAL ELECTRICAL
OUTLETS, PLUMBING SERVICES, AND HVAC CONNECTIONS. NO ALLOWANCE WILL
BE MADE FOR MINOR VARIATIONS IN SERVICE CONNECTIONS FROM THOSE
SPECIFIED OR INDICATED ON THE CHANGES.
SECTION 01045 - CUTTING & PATCHING
1.02 - NEW SERVICES IN EXISTING WALLS
F
A. EXAMINE ALL MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS CAREFULLY.
WHERE NEW ELECTRICAL OUTLETS, JUNCTION BOXES, THERMOSTATS, PIPING,
AND THE LIKE ARE INDICATED ON EXISTING WALLS OF ANY CONSTRUCTION TYPE
PROVIDE ALL LABOR AND MATERIALS TO CUT, SLOT OR CHASE SAID WALL AS
NEEDED FOR A CONCEALED INSTALLATION OF SERVICES. COOPERATE WITH
TRADE REQUIRED CUTTING OR SLOTTING, AND DO MINIMUM POSSIBLE, WHILE
MAINTAINING REQUIREMENTS OF OTHER SECTIONS. PATCH WALL SURFACE AS
NEEDED TO RESTORE WALL TO LIKE NEW CONDITION. THIS REQUIREMENT IS
MANDATED BY THE OWNER AND WILL BE STRICTLY ENFORCED.
SECTION 01300 SUBMITTALS, PRODUCTS &
F SUBSTITUTIONS
1.01 - SUMMARY
A. PROVIDE TYPES OF SUBMITTALS LISTED IN INDIVIDUAL SECTIONS AND IN NUMBER
OF COPIES REQUIRED BELOW.
1. SHOP DRAWINGS, REVIEWED, ANNOTATED AND STAMPEDAPPROVED BY
THE CONTRACTOR - SUBMIT THREE BLACKLINE PRINTS.
2, PRODUCT DATA - 6 COPIES, REVIEWED, ANNOTATED AND STAMPED
APPROVED BY THE CONTRACTOR. PRODUCT DATA SHALL INCLUDE
COMPLETE SPECIFICATIONS, PERFORMANCE DATA, CERTIFIED
LABORATORY TEST REPORT DATA, INSTALLATION INSTRUCTIONS, HEALTH
AND SAFETY PRECAUTIONS, AND MAINTENANCE INSTRUCTIONS, AND
SHALL SHOW ILLUSTRATED CAPACITIES, CHARACTERISTICS, WIRING
D DIAGRAMS, CONTROLS, AND OTHER PERTINENT INFORMATION FOR
COMPLETE PRODUCT AND PRODUCT USE DESCRIPTION. IF MORE THAN
ONE SIZE OR TYPE IS SHOWN ON ANY PRINTED SHEET, INDICATE CLEARLY
INTENDED ITEM(S). SEE MECHANICAL, PLUMBING AND ELECTRICAL
SECTIONS FOR PARTICULAR SUBMITTAL REQUIREMENTS.
3. SAMPLES - 2, PLUS EXTRA SAMPLES AS REQUIRED TO INDICATE RANGE OF
COLOR, FINISH, AND TEXTURE TO BE EXPECTED.
4. MOCK -UPS - AS REQUIRED IN THE TECHNICAL SPECIFICATION.
5. INSPECTION AND TEST REPORTS - 4 COPIES.
6, WARRANTIES - 4 COPIES.
7. CLOSEOUT SUBMITTALS - 4 COPIES.
C SECTION 07900 JOINT SEALERS
1.01 - SUMMARY
A, PROVIDE SEALANTS AT INTERSECTION OF ALL DISSIMILAR BUILDING COMPONENTS.
1. DOOR FRAMES TO WALL SURFACE.
2. CASEWORK TO WALL SURFACE.
3. COUNTERTOP TO WALL SURFACE.
4. COUNTERTOP TO BACK SPLASH.
5. ACCESS PANELS TO WALL /CEILING,
6. GLASS TO FRAME MATERIAL.
7. PARTITIONS TO ADJOINING MATERIALS.
B. PROVIDE SEALANT AT ALL PENETRATIONS OF MECHANICAL EQUIPMENT, PIPING AND
DUCTWORK WHERE IT PASSES THROUGH NEW OR EXISTING PARTITIONS, WHETHER
EXPOSED TO VIEW OR CONCEALED ABOVE NEW OR EXISTING CEILINGS OR OTHER
FINISH SURFACE. THE INTENT OF THIS REQUIREMENT IS TO FULLY SEAL THE
E PROJECT AREA FROM ADJOINING EXISTING SPACES AND TO SEAL EACH SPACE
WITHIN THE PROJECT FROM EACH OTHER.
2.01 - MATERIALS
A. JOINT SEALANT MATERIALS:
1. GENERAL INTERIOR USE: ONE PART, SILICONIZED ACRYLIC EQUAL TO PECORA
AC-20, SUITABLE TO RECEIVE PAINT FINISH.
-- 3.01 - INSTALLATION
B. PROVIDE SEALANTS IN COLORS AS SELECTED FROM MANUFACTURER'S STANDARDS.
C. INSTALL MATERIALS AND SYSTEMS IN ACCORDANCE WITH MANUFACTURER'S
INSTRUCTIONS AND APPROVED SUBMITTALS. INSTALL MATERIALS AND SYSTEMS
IN PROPER RELATION WITH ADJACENT CONSTRUCTION AND WITH UNIFORM
APPEARANCE. COORDINATE WITH WORK OF OTHER SECTIONS. CLEAN AND PRIME
JOINTS, AND INSTALL BOND BREAKERS, BACKER RODS AND SEALANT AS
A RECOMMENDED BY MANUFACTURERS.
16 1 15 1 14
wu
13 1 12 1 11 1 10 1 9 1 6 7
6
5
0
SECTION 09680 - CARPETING
1.01 -SUMMARY
A. CARPET FOR GLUED -DOWN INSTALLATION.
1.02 - SUBMITTALS
A. SUBMIT FOR APPROVAL SAMPLES, PRODUCT DATA, WARRANTY, MAINTENANCE DATA.
B. SUBMIT FOR APPROVAL CARPET INSTALLATION " SHOP DRAWINGS" TO BE PROVIDED
TO SHOW CARPET LAYOUT, SEAMS, AND MACHINE DIRECTION. IN BROADLOOM
CARPET, LOCATE SEAMS ONLY IN AREAS WITH LOW TRAFFIC AND MINIMIZE
THE NUMBER OF SEAMS. SINCE ALL CARPET HAS A MACHINE DIRECTION DUE
TO THE MANUFACTURING PROCESS, SHOW MACHINE DIRECTIONS ON SHOP
DRAWINGS AND RUN ALL CARPET "GRAIN" IN THE SAME DIRECTION. SHOW
CHANGE OF DYE LOT, IF ANY.
1.03 - QUALITY ASSURANCE
A. PROVIDE PRODUCTS OF LISTED MANUFACTURER
TE WHICH HAVE BEEN IN
SATISFACTORY USE IN SIMILAR SERVICE FOR THREE YEARS.
EXPERIENCED INSTALLERS. DELIVER, HANDLE, AND STORE MATERIALS
IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
2.01 - MATERIALS
A. MATERIALS:
1. CARPET SHALL BE SHAW CONTRACT GROUP, MODEL: 5A020,
- COLOR: GLOW. FOR PRICING ONLY - FINAL SELECT
TO BE MADE BY ARCHITECT
B. MOUNTING:
1. DIRECT GLUE DOWN: WATERPROOF, STRIPPABLE, WATER- RESISTAN,
NON- FLAMMABLE, NON - COMBUSTIBLE, LOW ODOR ADHESIVE.
2. ADHESIVE MUST BE APPROVED BY SPECIFIED CARPET MANUFACTURER
FOR USE WITH THEIR PRODUCT.
C. ACCESSORIES: RESILIENT BASE, SEE SECTION 09650.
3.01 - INSTALLATION
A. INSPECT SUBSTRATES FOR DETRIMENTAL CONDITIONS. BEGINNING WORK MEANS
ACCEPTANCE OF SUBSTRATE.
B. PREPARE FLOORS; INSTALL USING METHOD REQUIRED AS RECOMMENDED BY
CARPET MANUFACTURER.
C. INSTALL MATERIALS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND
APPROVED SUBMITTALS. INSTALL MATERIALS IN PROPER RELATION WITH ADJACENT
CONSTRUCTION AND WITH UNIFORM APPEARANCE. COORDINATE WITH WORK OF
OTHER SECTIONS.
SECTION 09690 - FLOOR PREPARATION
1.01 -SUMMARY
A. PROVIDE PREPARATION OF SUB - FLOORING FOR INSTALLATION OF
CARPET AND RESILIENT FLOORING.
B. IN GENERAL, THE SCOPE OF THE WORK OF THIS SECTION INCLUDES,
BUT IS NOT LIMITED TO, INSTALLATION OF A THIN COATING OF FLOOR
PREPARATION MATERIALS TO COVER AND SMOOTH MASTIC LEFT BY
REMOVAL OF VINYL COMPOSITION TILE UNDER SELECTIVE DEMOLITION
WORK, AS WELL AS OTHER PREPARATORY WORK AS MAY BE REQUIRED
FOR FINISH FLOORING. THIS WORK IS TO INCLUDE A COATING OF NEW
MATERIALS OVER THE ENTIREAREA OF THE PROJECT.
1.02 - SUBMITTALS
A, SUBMIT FOR APPROVAL PRODUCT DATA AND WRITTEN CONFIRMATION OF
COMPATIBILITY OF PRODUCTS PROVIDED UNDER THIS SECTION WITH
ADHESIVES AND OTHER PRODUCTS TO BE PROVIDED BY FINISH FLOORING
TRADES.
1.03 - QUALITY ASSURANCE
A. COMPLY WITH GOVERNING CODES AND REGULATIONS. PROVIDE
PRODUCTS OF ACCEPTABLE MANUFACTURERS WHICH HAVE BEEN
IN SATISFACTORY USE IN SIMILAR SERVICE FOR THREE YEARS.
USE EXPERIENCED INSTALLERS. DELIVER, HANDLE, AND STORE
MATERIALS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
B. PROVIDE WRITTEN MANUFACTURERS /INSTALLER WARRANTY AGAINST
LOSS OF BOND FROM SUBSTRATES, FOR A PERIOD OF TWO YEARS
FROM SUBSTANTIAL COMPLETION.
2.01 - MATERIALS
A. FLOOR LEVELING /PATCHING COMPOUNDS:
B. PROVIDE PORTLAND CEMENT /LATEX MODIFIED PATCHING /LEVELING
COMPOUND SELECTED FOR COMPATIBILITY WITH SUBSTRATES, EXISTING
CONDITIONS, AND WITH ADHESIVES AND OTHER PRODUCTS PROVIDED
UNDER FINISH FLOORING SECTIONS.
3.01 - INSTALLATION
A. COMPLY WITH MANUFACTURER'S INSTRUCTIONS AND
RECOMMENDATIONS.
B. INSTALL PRODUCT OVER EXISTING SUBSTRATES THAT HAVE BEEN
CLEANED AND PRIMED AS NECESSARY BY THIS TRADE.
BEGINNING WORK IMPLIES ACCEPTANCE OF SUBSTRATES.
C. LEVEL TO 1/8" IN 10' TOLERANCE. REPEAT AND RE -PATCH CRACKING
LEFT BY FIRST COATING AS REQUIRED. PROVIDE MULTIPLE COATS
AS NEEDED. DISK SAND AND VACUUM SURFACE AS NEEDED PRIOR
TO INSTALLATION OF FINISH FLOOR.
D. INSTALLERS SHALL BE EXPERIENCED IN THE APPLICATIONS OF ALL
PRODUCTS USED.
6
5
m
3 1 2
DIVISION 9 - FINISHES
SECTION 09900 - PAINTING
1.01 - SUMMARY
A. PROVIDE ALL LABOR, MATERIAL, EQUIPMENT, SERVICES AND
TRANSPORTATION REQUIRED TO COMPLETE PAINTING OF ALL
UNFINISHED
INTERIOR AND EXTERIOR SURFACES, BOTH NEW AND EXISTING.
B. PROVIDE SURFACE PREPARATION AS NEEDED FOR ALL SURFACES.
C. WHERE INDICATED, PAINT EXPOSED STRUCTURE, AND ALL EXPOSED
DUCTWORK, PIPING, CONDUIT, AND DEVICES EXPOSED WHERE THERE
IS NO SUSPENDED CEILING. PREPARE EXISTING SLAB SURFACES AS
NEEDED TO PRESENT A SMOOTH FINISH.
D. PAINT ALL DESKTOP SUPPORT BRACKETS (RAKKS BRACKETS), COLOR TO
MATCH ADJOINING WALL.
E. PAINT ALL EXPOSED MECHANICAL AND ELECTRICAL WORK INCLUDING
PIPING DUCTWORK FANS MOTORS AND ANY OTHER O
R R
EQUIPMENT UNLESS FACTORY Y FINISHED.
F. BACKPRIME ALL INTERIOR FINISHED WOODWORK SURFACES WHICH
WILL BE CONCEALED AFTER INSTALLATION.
G. PAINT ALL EXISTING METAL DOORS AND FRAMES IN PROJECT AREA.
1.02 - INTENT
A. IT IS THE INTENT OF THIS SECTION TO PROVIDE FOR PAINTING OF ALL
EXPOSED AND UNFINISHED SURFACES TO PROVIDE A UNIFORM,
SMOOTH, AND UNBLEMISHED SURFACE.
1.03 - RELATED WORK
A. CASEWORK FINISHES, SEE SECTION 06410.
B. SHOP PRIMING OF CERTAIN ITEMS AS SPECIFIED ELSEWHERE-
C. SPECIAL WALL FINISHES.
D. REFER TO MECHANICAL AND ELECTRICAL SPECIFICATIONS FOR WITH
RESPECT TO IDENTIFICATION BANDING OF EQUIPMENT, DUCTWORK,
PIPING, CONDUIT, AND PAINTING OF PIPING, HANGARS AND SUPPORTS
IN CONCEALED SPACES.
1.04 - SUBMITTALS
A. SUBMIT FOR APPROVAL A COMPLETE SCHEDULE OF PAINT AND FINISH
MATERIAL PROPOSED FOR USE ON THE PROJECT BEFORE ORDERING OR
PROCEEDING WITH ANY WORK.
B. SUBMIT PRODUCT DATA SHEETS FOR ALL PRODUCTS USED.
C. SUBMIT LARGE SIZE COLOR'DRAW DOWN' SAMPLES OF ALL COLORS AND
FINISHES TO BE USED ON THIS PROJECT.
1.05 - QUALITY ASSURANCE
A. COMPLY WITH GOVERNING CODES AND REGULATIONS. PROVIDE
PRODUCTS EXACTLY AS SPECIFIED, NO SUBSTITUTIONS ARE ALLOWED.
B. USE EXPERIENCED INSTALLERS, SKILLED IN THE TRADE.
C. DELIVER, HANDLE, AND STORE AND INSTALL MATERIALS IN ACCORDANCE
WITH MANUFACTURER'S INSTRUCTIONS AND WITH DUE REGARD FOR
MAINTENANCE OF QUALITY OF MATERIALS, F I RE SAFETY, VENTILATION,
SECURITY, AND DISPOSAL OF WASTE MATERIALS.
2.01 - MATERIALS
A. FIRST -LINE STANDARD PRODUCTS FOR ALL SYSTEMS BY SHERWIN
WILLIAMS. PROVIDE THE NUMBER OF COATS INDICATED AS A MIN /MUM
SHOULD COVERAGE NOT BE ADEQUATE, PROVIDE ADDED COATS AT NO
COST TO THE OWNER.
B. INTERIOR PAINT SYSTEMS:
1. DRYWALL AND MASONRY WALLS, SYSTEM 2, FOR USE IN PATIENT
ROOMS, EXAM ROOMS, TREATMENT AND DIAGNOSTIC AREAS,
OFFICE AREAS, CORRIDORS, LOBBIES, CONFERENCE AND MEETING
ROOMS, LOUNGES, WAITING AREAS, PIPE AND WIRE CLOSETS,
MACHINE ROOMS: LATEX PRIMER, ONE COAT; LATEX EGGSHELL TWO
COATS. ALLOW 25% OF WALL AREA TO BE
SPECIAL ACCENT COLOR (SAME PRODUCT LINE).- FINAL COLOR AND
PRODUCT T.B.D. BY ARCHITECT,
2. METAL FRAMES AND OTHER FERROUS METALS, PAINTED FRAMES:
LATEX ONE COAT;
SEMIGLOSS ACRYLIC TWO
COATS, ALLOW 25% OF FRAMES AND DOORS TO BE SPECIAL
ACCENT COLOR (SAME PRODUCT LINE).- FINAL COLOR AND PRODUCT
T.B.D. BY ARCHITECT.
3
APPROVED 10,
nNT
ISSUED FOR
PERMIT AND
CONSTRUCTION
DATE:
02/ G7/ 2=
CLIENT CODE/FILE
NUMBER: h
PROJECT ID- SUBMISSION
NUMBER:
ROBERT BROWN
ARCHITECT .
LICENSE; `AR92624' • ..
y �� Ga'sis x,+•
t<, -
'. ,•
tf �
Arch#echse
�� A••esm,� r�
htedar
LINEA 5, inc.
420 LINCOLN ROAD, SUTE 258
MAM BEACH, FLORIDA 33139
305- 673 -0004
Em 305- 673 -0080
Cu
SECTION 09510
DIVISION 9 - FINISHES
ACOUSTICAL CEILINGS - CON'T
SECTION 09250 - GYPSUM DRYWALL
1.01 - SUMMARY
2.02 - ATTIC STOCK
A. PROVIDE GYPSUM PLASTER FINISHED DRYWALL WORK AND /OR TAPED
A. PROVIDE ATTIC STOCK IN THE AMOUNT OF 10% OF AREA FOR ALL CEILING
JOINT FINISHED DRYWALL WORK INCLUDING METAL SUPPORT SYSTEMS:
TILES. DELIVER TO AREA DESIGNATED BY OWNER.
1. INTERIOR WALLS, PARTITIONS, AND SOFFITS.
3.02 - INSTALLATION - GENERAL
2. SEALANT WORK AT WALL PERIMETERS.
0
A. MEASURE AND LAYOUT TO AVOID LESS THAN 1/2 PANEL UNITS. SEE
2.01 - MATERIALS
CEILING PLAN FOR SPECIFIC LAYOUT REQUIREMENTS_
A. GYPSUM BOARD (GENERAL USE):
1, 5/8" THICK REGULAR AND FIRE RESISTANT, U.S. GYPSUM
B. INSTALL PANELS WITH PATTERN RUNNING ONE -WAY.
"SHEETROCK ", TAPERED EDGES OR APPROVED EQUAL.
cz
00
C. INSTALL MATERIALS AND SYSTEMS IN ACCORDANCE WITH
B. GYPSUM BOARD (LAMINATED WALLS):
MANUFACTURER'S INSTRUCTIONS AND APPROVED SUBMITTALS.
1. 1/4" THICK REGULAR U.S. GYPSUM "SHEETROCK ", TAPERED
INSTALL MATERIALS AND SYSTEMS IN PROPER RELATION WITH
EDGES OR APPROVED EQUAL.
ADJACENT CONSTRUCTION AND WITH UNIFORM APPEARANCE.
I--+
- (�
COORDINATE WITH WORK OF OTHER SECTIONS.
C. STEEL STUDS: 20 GAGE SCREW -TYPE STEEL STUDS, ASTM C 645,
3.02 - INSTALLATION - HANGERS
16 " O.C, 25 GAUGE STUDS WILL NOT BE ALLOWED. SIZES AS INDICATED.
W
A. EACH VERTICAL WIRE SHALL BE ATTACHED TO THE CEILING SUSPENSION
D. JOINT REINFORCEMENT: ASTM C 587 PAPER OR MESH TAPE AND USG
MEMBER AND TO THE SUPPORT ABOVE WITH A MINIMUM OF THREE TURNS
"DURABOND" OR "EASY SAND" COMPOUND.
TO PROVIDE A CONNECTION CAPABLE OF CARRYING NOT LESS THAN A
100 LB (45.4 KG) LOAD.
E. ACCESSORIES: GALVANIZED STEEL CORNER BEADS, CASING BEADS,
CONTROL JOINTS, AS RECOMMENDED BY MANUFACTURER FOR
B. WIRES SHALL NOT ATTACH TO OR BEND AROUND INTERFERING MATERIAL
APPLICATION.
OR EQUIPMENT. A TRAPEZE OR EQUIVALENT DEVICE SHALL BE USED
WHERE OBSTRUCTIONS PRECLUDE DIRECT SUSPENSION. TRAPEZE
F. GENERAL PERIMETER SEALANT: COMMERCIAL ACOUSTICAL SEALANT
SUSPENSIONS SHALL BE A MINIMUM OF BACK TO BACK 1 1/4"
EQUAL TO USG ACOUSTICAL SEALANT.
COLD- ROLLED CHANNELS FOR SPANS EXCEEDING 48"
G. FLOOR JOINT SEALANT SHALL BE PURE SILICONE EQUAL TO GE 1700 OR
C. SUSPENSION WIRES SHALL NOT HANG MORE THAN ONE IN SIX OUT OF
DOW 795.
PLUMB UNLESS COUNTERSLOPING WIRES ARE PROVIDED,
H, FURRING CHANNELS SHALL BE 7/8" THICK NOMINAL STEEL "HIGH- HATS ".
3.03 - INSTALLATION - SUSPENSION SYSTEM
A. INSTALL SUSPENSION BY FOLLOWING MANUFACTURER'S INSTRUCTIONS
3.01 - INSTALLATION
AND RECOMMENDATIONS AND ASTM C636 AND ASTM E580.
A. AT START OF WORK, LAYOUT ALL NEW WORK IN CHALK ON FLOOR.
ALLOW FOR EXISTING CONDITIONS AND INSTALLATION OF ALL
B. A TERMINAL END OF A GRID MEMBER OR TILE SHALL REST ON THE LEDGE
SERVICES. SECURE ARCHITECT'S REVIEW OF LAYOUT BEFORE
OR MOLDING WITH AT LEAST 3/8 -IN. (9 5 MM CLEARANCE FROM AN EDGE
)
PROCEEDING.
OR WALL AS SHOWN ON DETAILS.
B. INSTALL FRAMING SYSTEM AT 16" O.C. MINIMUM.
C. ENDS OF MAIN RUNNERS AND CROSS MEMBERS SHALL BE TIED
TOGETHER WITH APPROVED SPACER BARS TO PREVENT THEIR
C. INSTALL ALL FRAMING WITH "SLIP JOINT" AT TOP AS DETAILED. ALLOW
SPREADING, SEE DETAILS.
FOR LIVE LOAD VERTICAL DEFLECTION OF SLABS.
D. ALL CEILING PENETRATIONS (COLUMNS, SPRINKLERS, ETC.) AND
D. PRIOR TO INSTALLATION OF WALLBOARD, REMOVE BY VACUUMING ALL
INDEPENDENTLY SUPPORTED FIXTURES OR SERVICES ARE CONSIDERED
CONSTRUCTION DEBRIS LEFT IN THE STUD TRACK. DO NOT CLOSE THE
AS PERIMETER CLOSURES. PROVIDE SIMILAR 3/8 -IN CLEARANCE AND
WALL UNTIL ALL DEBRIS IS REMOVED.
MINIMUM 7/8" SUPPORT LEDGE (WALL MOLDING) OR PROVIDE SUITABLE
ESCUTCHEONS OR OTHER APPROVED CLOSURE DETAILS.
E. INSTALL BOARDS VERTICALLY. DO NOT ALLOW EXPOSED BUTT -TO -BUTT
JOINTS AND JOINTS THAT DO NOT FALL OVER FRAMING MEMBERS.
3,04 - INSTALLATION - MECH /ELEC DEVICES
F. INSTALL ACCESS PANELS PROVIDED BY TRADES REQUIRING THEM.
A. ALL LIGHTING FIXTURES SHALL BE SUPPORTED BY MECHANICAL MEANS
INSTALL TRIM AND ACCESSORIES IN STRICT COMPLIANCE WITH
AS SPECIFIED IN THE ELECTRICAL SPECIFICATIONS AND THE NATIONAL
MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS.
ELECTRICAL CODE, SECTION 410- 16(C), AND AS REQUIRED BY THE
2004 FLORIDA BUILDING CODE W /REVISIONS.
G. PROVIDE FIRE -RATED SYSTEMS WHERE INDICATED AND WHERE
REQUIRED BY AUTHORITIES HAVING JURISDICTION. EXCEPT AS
B. SURFACE - MOUNTED AND FLUSH / RECESSED LIGHTING FIXTURES SHALL
OTHERWISE INDICATED, EXTEND ALL PARTITIONS TO UNDERSIDE OF
BE ATTACHED TO THE CEILING SYSTEM WITH POSITIVE CLAMPING
DECK ABOVE CEILING.
DEVICES THAT COMPLETELY SURROUND THE SUPPORTING MEMBERS,
BUT IN NO CASE SHALL THE FIXTURE EXCEED THE DESIGN CARRYING
H. GYPSUM BOARD FINISH LEVELS: FINISH PANELS TO LEVELS INDICATED
CAPACITY OF THE SUPPORTING MEMBERS. INDEPENDENT SAFETY
BELOW, ACCORDING TO ASTM C 840, FOR LOCATIONS AS INDICATED:
HANGARS SHALL BE ATTACHED BETWEEN THE CLAMPING DEVICE AND
1. LEVEL 1: EMBED TAPE AT JOINTS IN CEILING PLENUM AREAS,
THE STRUCTURE ABOVE IN THE FOLLOWING SITUATIONS:
CONCEALED AREAS, AND WHEREVER INDICATED, UNLESS A
1. WHEN REQUIRED BY THE ELECTRICAL SPECIFICATIONS AND / OR
HIGHER LEVEL OF FINISH IS REQUIRED FOR FIRE - RESISTANCE
2. WHEN THE WEIGHT OF THE FIXTURE EXCEEDS 56 POUNDS.
RELATED ASSEMBLIES, AND SOUND -RATED ASSEMBLIES.
2. LEVEL 2: EMBED TAPE AND APPLY SEPARATE FIRST COAT OF JOINT
C. PENDANT -HUNG LIGHTING FIXTURES SHALL BE SUPPORTED DIRECTLY
COMPOUND TO TAPE, FASTENERS, AND TRIM FLANGES WHERE
FROM THE STRUCTURE ABOVE USING NO. 9 -GAGE WIRE OR AN
PANELS ARE SUBSTRATE FOR TILE AND WHERE INDICATED.
APPROVED ALTERNATE SUPPORT WITHOUT USING THE CEILING
3. LEVEL 3: EMBED TAPE AND APPLY SEPARATE FIRST AND FILL
SUSPENSION SYSTEM FOR DIRECT SUPPORT.
COATS OF JOINT COMPOUND TO TAPE FASTENERS, AND TRIM
FLANGES WHERE INDICATED. USE THIS SYSTEM FOR CONCEALED
D. CEILING MOUNTED AIR TERMINAL DEVICES SHALL BE POSITIVELY
SPACES THAT ARE SUBJECT TO MAINTENANCE OF FIRE RATINGS.
ATTACHED TO THE CEILING SUSPENSION MAIN RUNNERS OR CROSS
4. LEVEL 4: EMBED TAPE AND APPLY SEPARATE FIRST, FILL, AND
RUNNERS AND SHALL HAVE, IN ADDITION, ATTACHMENTS AS REQUIRED
FINISH COATS OF JOINT COMPOUND TO TAPE, FASTENERS, AND
BY THE MECHANICAL SPECIFICATIONS.
TRIM FLANGES AT PANEL SURFACES THAT WILL BE EXPOSED TO
VIEW. USE THIS SYSTEM AT ALL AREAS UNLESS OTHERWISE
INDICATED.
5. LEVEL 5: EMBED TAPE AND APPLY SEPARATE FIRST, FILL, AND
SECTION 09650 - RESILIENT FLOORING/ VINYL
FINISH COATS OF JOINT COMPOUND TO TAPE, FASTENERS, AND
TRIM FLANGES, AND APPLY SKIM COAT OF JOINT COMPOUND OVER
BASE
ENTIRE SURFACE AT PANEL SURFACES AS INDICATED. PROVIDE
THIS SYSTEM ONLY WHERE INDICATED.
2.01 - MATERIALS
I. SEAL PERIMETER OF ALL DRYWALL ASSEMBLIES TO FLOOR, WALL, DECK
OR OTHER ASSEMBLY WITH A FULL, CONTINUOUS BEAD OF APPROVED
SEALANT. SEAL ALL PENETRATIONS. USE SILICONE AT FLOOR JOINT.
A. ACCESSORIES: WALL BASE: 4" HIGH VINYL AT CARPET AREAS, 6" HIGH
VINYLAT RESILIENT FLOORING, 1/8" THICK, MATTE FINISH, AT ALL AREAS,
J. MAKE ALL OLD WORK/NEW WORK JUNCTURES LIKE NEW.
INCLUDING FACE OF CASEWORK, BY ARMSTRONG. PROVIDE COVE
BASE AT RESILIENT FLOORING, STRAIGHT BASE AT CARPET AREAS,
K. EXAMINE ALL MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS
FOR PRICING ONLY - FINAL SELECT TO BE MADE BY ARCHITECT.
CAREFULLY, WHERE NEW ELECTRICAL OUTLETS, JUNCTION BOXES,
1. CORNERS: VINYL BASE CORNERS SHALL BE SITE FORMED.
THERMOSTATS, PIPING, AND THE LIKE ARE INDICATED ON EXISTING
2. ADHESIVE: WATERPROOF, AS RECOMMENDED BY THE
WALL, PROVIDE ALL LABOR AND MATERIALS TO CUT, SLOT OR CHASE
MANUFACTURER.
SAID WALL AS NEEDED FOR A CONCEALED INSTALLATION OF SERVICES.
3. LEVELING & PATCHING COMPOUNDS: AS APPROVED BY FLOORING
COOPERATE WITH TRADE REQUIRED CUTTING OR SLOTTING, AND DO
MANUFACTURER.
MINIMUM POSSIBLE, WHILE MAINTAINING REQUIREMENTS OF OTHER
SECTIONS. PATCH WALL SURFACE AS NEEDED TO RESTORE WALL TO
B. FIRE PERFORMANCE
LIKE NEW CONDITION, THIS REQUIREMENT IS MANDATED BY THE OWNER
ASTM E 648 CRITICAL RADIANT FLUX CLASS 1•• 0.45 OR MORE WATTS /CM2
AND WILL BE STRICTLY ENFORCED.
ASTM E 663 SMOKE DEVELOPED 450 OR LESS
NUMERICAL FLAMMABILITY RATINGS ALONG MAY NOT DEFINE THE
PERFORMANCE OF THE PRODUCT UNDER ACTUAL FIRE CONDITIONS. THESE
RATINGS ARE PROVIDED ONLY FOR USE IN THE SELECTION OF PRODUCTS TO MEET
SECTION 09510 -ACOUSTICAL CEILINGS
THE SPECIFIED LIMITS.
2.01 - MATERIALS
A. ACOUSTICAL TILES:
2.03 - ATTIC STOCK
1. TYPE ACT -1: USE 3/4" THICK, MINERAL FIBER TILE, 24 "X24 ",
A. PROVIDE ATTIC STOCK IN THE AMOUNT OF 10% OF AREA FOR ALL FLOOR
ARMSTRONG REGULAR LAYIN, CIRRUS 589 TILE. FOR PRICING ONLY -
TILES AND RESILIENT BASE. DELIVER TO AREA DESIGNATED BY OWNER.
FINAL SELECT TO BE MADE BY ARCHITECT.
3.01 - INSTALLATION
B. EXPOSED GRID SUSPENSION SYSTEM: HEAVY DUTY PAINTED STEEL.
A. COMPLY WITH MANUFACTURER'S INSTRUCTIONS AND
1. TEE SUSPENSION SYSTEM, ARMSTRONG PRELUDE 9/16" HEAVY DUTY,
RECOMMENDATIONS.
BEVELED TEGULAR EDGE. FOR PRICING ONLY - FINAL SELECT TO BE
MADE BY ARCHITECT.
B. PREPARE SURFACES BY CLEANING, LEVELING AND PRIMING. LEVEL TO
2. MAIN RUNNERS AND CROSS RUNNERS OF THE CEILING SYSTEM AND
1/8" IN 10' TOLERANCE. PATCH AS REQUIRED. DISK SAND AND VACUUM
THEIR SPLICES, INTERSECTION CONNECTORS, AND EXPANSION
SURFACE AS NEEDED PRIOR TO LAYING TILES.
DEVICES SHALL BE DESIGNED AND CONSTRUCTED TO CARRY A
MEAN ULTIMATE TEST LOAD OF NOT LESS THAN 60 LB (27.2 KG) IN
0. INSTALL ALL FLOORING PRIOR TO AND COMPLETELY COVERING THE
TENSION WITH A 50 MISALIGNMENT OF THE MEMBERS IN ANY
AREAS UNDER ALL CASEWORK AND EQUIPMENT.
DIRECTION AND IN COMPRESSION.
D. INSTALL MATERIAL WITH TIGHT JOINTS AND WITH ONE -WAY PATTERN,
C. COLORS: WHITE TO MATCH TILES.
1. SUPPORT WIRES OF SOFT, ANNEALED, GALVANIZED STEEL WIRE
E. INSTALL BASE AND TRIM ACCESSORIES TO MINIMIZE JOINTS,
SHALL NOT BE SMALLER THAN NO. 12 GA. SPACED AT 4' -0" ON CENTER
OR NO. 10 GA. AT 5' -0" ON CENTER ALONG EACH MAIN RUNNER
F. INSTALLERS SHALL BE EXPERIENCED IN THE APPLICATIONS OF ALL
UNLESS CALCULATIONS JUSTIFYING THE INCREASED SPACING ARE
PRODUCTS USED.
PROVIDED.
2. ALL PERIMETER CLOSURE ANGLES OR CHANNELS SHALL PROVIDE A
G. PROVIDE 4" VINYL BASE AROUND ALL CASEWORK AS INDICATED.
SUPPORT LEDGE OF APPROXIMATELY 7/8 IN. (22.2 MM) OR GREATER.
3. SPACER BARS TO TIE TOGETHER PERIMETER COMPONENTS SHALL BE
H. BROOM CLEAN AND REMOVE ANY MAJOR STAINS OR DIRT. REPAIR ALL
AS RECOMMENDED BY THE SUSPENSION SYSTEM MANUFACTURER.
DAMAGED TILES. PROJECT FLOOR FROM DAMAGE UNTIL ACCEPTANCE
BY OWNER AND APPLICATION OF POLISH BY OWNER.
D. FIRE PERFORMANCE
ASTM E84 AND CAN /ULC S102 SURFACE BURNING CHARACTERISTICS. FLAME
SPREAD INDEX 25 OR LESS. SMOKE DEVELOPED INDEX 50 OR LESS (UL LABEL),
FIRE GUARD: A FIRE RESISTIVE CEILING WHEN USED IN APPLICABLE UL
ASSEMBLIES.
13
1 12 1
11
1 10
1 9
1 8
1 l
6
5
0
SECTION 09680 - CARPETING
1.01 -SUMMARY
A. CARPET FOR GLUED -DOWN INSTALLATION.
1.02 - SUBMITTALS
A. SUBMIT FOR APPROVAL SAMPLES, PRODUCT DATA, WARRANTY, MAINTENANCE DATA.
B. SUBMIT FOR APPROVAL CARPET INSTALLATION " SHOP DRAWINGS" TO BE PROVIDED
TO SHOW CARPET LAYOUT, SEAMS, AND MACHINE DIRECTION. IN BROADLOOM
CARPET, LOCATE SEAMS ONLY IN AREAS WITH LOW TRAFFIC AND MINIMIZE
THE NUMBER OF SEAMS. SINCE ALL CARPET HAS A MACHINE DIRECTION DUE
TO THE MANUFACTURING PROCESS, SHOW MACHINE DIRECTIONS ON SHOP
DRAWINGS AND RUN ALL CARPET "GRAIN" IN THE SAME DIRECTION. SHOW
CHANGE OF DYE LOT, IF ANY.
1.03 - QUALITY ASSURANCE
A. PROVIDE PRODUCTS OF LISTED MANUFACTURER
TE WHICH HAVE BEEN IN
SATISFACTORY USE IN SIMILAR SERVICE FOR THREE YEARS.
EXPERIENCED INSTALLERS. DELIVER, HANDLE, AND STORE MATERIALS
IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
2.01 - MATERIALS
A. MATERIALS:
1. CARPET SHALL BE SHAW CONTRACT GROUP, MODEL: 5A020,
- COLOR: GLOW. FOR PRICING ONLY - FINAL SELECT
TO BE MADE BY ARCHITECT
B. MOUNTING:
1. DIRECT GLUE DOWN: WATERPROOF, STRIPPABLE, WATER- RESISTAN,
NON- FLAMMABLE, NON - COMBUSTIBLE, LOW ODOR ADHESIVE.
2. ADHESIVE MUST BE APPROVED BY SPECIFIED CARPET MANUFACTURER
FOR USE WITH THEIR PRODUCT.
C. ACCESSORIES: RESILIENT BASE, SEE SECTION 09650.
3.01 - INSTALLATION
A. INSPECT SUBSTRATES FOR DETRIMENTAL CONDITIONS. BEGINNING WORK MEANS
ACCEPTANCE OF SUBSTRATE.
B. PREPARE FLOORS; INSTALL USING METHOD REQUIRED AS RECOMMENDED BY
CARPET MANUFACTURER.
C. INSTALL MATERIALS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND
APPROVED SUBMITTALS. INSTALL MATERIALS IN PROPER RELATION WITH ADJACENT
CONSTRUCTION AND WITH UNIFORM APPEARANCE. COORDINATE WITH WORK OF
OTHER SECTIONS.
SECTION 09690 - FLOOR PREPARATION
1.01 -SUMMARY
A. PROVIDE PREPARATION OF SUB - FLOORING FOR INSTALLATION OF
CARPET AND RESILIENT FLOORING.
B. IN GENERAL, THE SCOPE OF THE WORK OF THIS SECTION INCLUDES,
BUT IS NOT LIMITED TO, INSTALLATION OF A THIN COATING OF FLOOR
PREPARATION MATERIALS TO COVER AND SMOOTH MASTIC LEFT BY
REMOVAL OF VINYL COMPOSITION TILE UNDER SELECTIVE DEMOLITION
WORK, AS WELL AS OTHER PREPARATORY WORK AS MAY BE REQUIRED
FOR FINISH FLOORING. THIS WORK IS TO INCLUDE A COATING OF NEW
MATERIALS OVER THE ENTIREAREA OF THE PROJECT.
1.02 - SUBMITTALS
A, SUBMIT FOR APPROVAL PRODUCT DATA AND WRITTEN CONFIRMATION OF
COMPATIBILITY OF PRODUCTS PROVIDED UNDER THIS SECTION WITH
ADHESIVES AND OTHER PRODUCTS TO BE PROVIDED BY FINISH FLOORING
TRADES.
1.03 - QUALITY ASSURANCE
A. COMPLY WITH GOVERNING CODES AND REGULATIONS. PROVIDE
PRODUCTS OF ACCEPTABLE MANUFACTURERS WHICH HAVE BEEN
IN SATISFACTORY USE IN SIMILAR SERVICE FOR THREE YEARS.
USE EXPERIENCED INSTALLERS. DELIVER, HANDLE, AND STORE
MATERIALS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
B. PROVIDE WRITTEN MANUFACTURERS /INSTALLER WARRANTY AGAINST
LOSS OF BOND FROM SUBSTRATES, FOR A PERIOD OF TWO YEARS
FROM SUBSTANTIAL COMPLETION.
2.01 - MATERIALS
A. FLOOR LEVELING /PATCHING COMPOUNDS:
B. PROVIDE PORTLAND CEMENT /LATEX MODIFIED PATCHING /LEVELING
COMPOUND SELECTED FOR COMPATIBILITY WITH SUBSTRATES, EXISTING
CONDITIONS, AND WITH ADHESIVES AND OTHER PRODUCTS PROVIDED
UNDER FINISH FLOORING SECTIONS.
3.01 - INSTALLATION
A. COMPLY WITH MANUFACTURER'S INSTRUCTIONS AND
RECOMMENDATIONS.
B. INSTALL PRODUCT OVER EXISTING SUBSTRATES THAT HAVE BEEN
CLEANED AND PRIMED AS NECESSARY BY THIS TRADE.
BEGINNING WORK IMPLIES ACCEPTANCE OF SUBSTRATES.
C. LEVEL TO 1/8" IN 10' TOLERANCE. REPEAT AND RE -PATCH CRACKING
LEFT BY FIRST COATING AS REQUIRED. PROVIDE MULTIPLE COATS
AS NEEDED. DISK SAND AND VACUUM SURFACE AS NEEDED PRIOR
TO INSTALLATION OF FINISH FLOOR.
D. INSTALLERS SHALL BE EXPERIENCED IN THE APPLICATIONS OF ALL
PRODUCTS USED.
6
5
m
3 1 2
DIVISION 9 - FINISHES
SECTION 09900 - PAINTING
1.01 - SUMMARY
A. PROVIDE ALL LABOR, MATERIAL, EQUIPMENT, SERVICES AND
TRANSPORTATION REQUIRED TO COMPLETE PAINTING OF ALL
UNFINISHED
INTERIOR AND EXTERIOR SURFACES, BOTH NEW AND EXISTING.
B. PROVIDE SURFACE PREPARATION AS NEEDED FOR ALL SURFACES.
C. WHERE INDICATED, PAINT EXPOSED STRUCTURE, AND ALL EXPOSED
DUCTWORK, PIPING, CONDUIT, AND DEVICES EXPOSED WHERE THERE
IS NO SUSPENDED CEILING. PREPARE EXISTING SLAB SURFACES AS
NEEDED TO PRESENT A SMOOTH FINISH.
D. PAINT ALL DESKTOP SUPPORT BRACKETS (RAKKS BRACKETS), COLOR TO
MATCH ADJOINING WALL.
E. PAINT ALL EXPOSED MECHANICAL AND ELECTRICAL WORK INCLUDING
PIPING DUCTWORK FANS MOTORS AND ANY OTHER O
R R
EQUIPMENT UNLESS FACTORY Y FINISHED.
F. BACKPRIME ALL INTERIOR FINISHED WOODWORK SURFACES WHICH
WILL BE CONCEALED AFTER INSTALLATION.
G. PAINT ALL EXISTING METAL DOORS AND FRAMES IN PROJECT AREA.
1.02 - INTENT
A. IT IS THE INTENT OF THIS SECTION TO PROVIDE FOR PAINTING OF ALL
EXPOSED AND UNFINISHED SURFACES TO PROVIDE A UNIFORM,
SMOOTH, AND UNBLEMISHED SURFACE.
1.03 - RELATED WORK
A. CASEWORK FINISHES, SEE SECTION 06410.
B. SHOP PRIMING OF CERTAIN ITEMS AS SPECIFIED ELSEWHERE-
C. SPECIAL WALL FINISHES.
D. REFER TO MECHANICAL AND ELECTRICAL SPECIFICATIONS FOR WITH
RESPECT TO IDENTIFICATION BANDING OF EQUIPMENT, DUCTWORK,
PIPING, CONDUIT, AND PAINTING OF PIPING, HANGARS AND SUPPORTS
IN CONCEALED SPACES.
1.04 - SUBMITTALS
A. SUBMIT FOR APPROVAL A COMPLETE SCHEDULE OF PAINT AND FINISH
MATERIAL PROPOSED FOR USE ON THE PROJECT BEFORE ORDERING OR
PROCEEDING WITH ANY WORK.
B. SUBMIT PRODUCT DATA SHEETS FOR ALL PRODUCTS USED.
C. SUBMIT LARGE SIZE COLOR'DRAW DOWN' SAMPLES OF ALL COLORS AND
FINISHES TO BE USED ON THIS PROJECT.
1.05 - QUALITY ASSURANCE
A. COMPLY WITH GOVERNING CODES AND REGULATIONS. PROVIDE
PRODUCTS EXACTLY AS SPECIFIED, NO SUBSTITUTIONS ARE ALLOWED.
B. USE EXPERIENCED INSTALLERS, SKILLED IN THE TRADE.
C. DELIVER, HANDLE, AND STORE AND INSTALL MATERIALS IN ACCORDANCE
WITH MANUFACTURER'S INSTRUCTIONS AND WITH DUE REGARD FOR
MAINTENANCE OF QUALITY OF MATERIALS, F I RE SAFETY, VENTILATION,
SECURITY, AND DISPOSAL OF WASTE MATERIALS.
2.01 - MATERIALS
A. FIRST -LINE STANDARD PRODUCTS FOR ALL SYSTEMS BY SHERWIN
WILLIAMS. PROVIDE THE NUMBER OF COATS INDICATED AS A MIN /MUM
SHOULD COVERAGE NOT BE ADEQUATE, PROVIDE ADDED COATS AT NO
COST TO THE OWNER.
B. INTERIOR PAINT SYSTEMS:
1. DRYWALL AND MASONRY WALLS, SYSTEM 2, FOR USE IN PATIENT
ROOMS, EXAM ROOMS, TREATMENT AND DIAGNOSTIC AREAS,
OFFICE AREAS, CORRIDORS, LOBBIES, CONFERENCE AND MEETING
ROOMS, LOUNGES, WAITING AREAS, PIPE AND WIRE CLOSETS,
MACHINE ROOMS: LATEX PRIMER, ONE COAT; LATEX EGGSHELL TWO
COATS. ALLOW 25% OF WALL AREA TO BE
SPECIAL ACCENT COLOR (SAME PRODUCT LINE).- FINAL COLOR AND
PRODUCT T.B.D. BY ARCHITECT,
2. METAL FRAMES AND OTHER FERROUS METALS, PAINTED FRAMES:
LATEX ONE COAT;
SEMIGLOSS ACRYLIC TWO
COATS, ALLOW 25% OF FRAMES AND DOORS TO BE SPECIAL
ACCENT COLOR (SAME PRODUCT LINE).- FINAL COLOR AND PRODUCT
T.B.D. BY ARCHITECT.
3
APPROVED 10,
nNT
ISSUED FOR
PERMIT AND
CONSTRUCTION
DATE:
02/ G7/ 2=
CLIENT CODE/FILE
NUMBER: h
PROJECT ID- SUBMISSION
NUMBER:
ROBERT BROWN
ARCHITECT .
LICENSE; `AR92624' • ..
y �� Ga'sis x,+•
t<, -
'. ,•
tf �
Arch#echse
�� A••esm,� r�
htedar
LINEA 5, inc.
420 LINCOLN ROAD, SUTE 258
MAM BEACH, FLORIDA 33139
305- 673 -0004
Em 305- 673 -0080
Cu
l.l. �
®
W
1.0
M
®
0
��
.M
Cu
= ®
Io.
cz
00
§2
u)2
,Cl) 0
■>
ilk
0
I--+
- (�
;