Loading...
09-236-002jpM mM■■ ONES 0 0 Non ■■ EMME■ 0MONS O■ MEMOS ■■ N■■■■ EMNO N Mom 0 SEMEN onE■■ ■■00 MEMOS ■NNNNN■■MENEM■■EHNEN■% MASS NOTIFICATION ■ ■ ■ ■ ■ NOT, r ■ ■ ■ 1. MASS NOTIFICATION SPEAKER WILL NOT WORK IN CONJUNCTION WITH FIRE ALARM SYSTEM HORNS. ■ ■ 2. IN THE EVENT OF A FIRE ALARM BEING ACTIVATED AND MASS NOTIFICATION IS NEEDED, MASS NOTIFICATION WILL OVERRIDE THE HORN OF FIRE ALARM AND SPEAKERS WILL BE ACTIVATED TO DIRECT INDIVIDUAL WITHIN FACILITY. ■ ■ UPON ACTIVATION HANDHELD MICROPHONE AT PANEL. ■ ■ 1. ALL SPEAKERS WILL BE ACTIVATED BY DESIGNATED FLOOR AT THE MAIN PANEL USING SWITCHES. ■ ■ ■ ■ ■ %■ EEN0 Oman MMENE■■■ NNONon ME■ MEM EME NS■■ NNRON0 MONO 0■■■ NON MENEM MENU soon NONE MENEM0MONSON■o man MEMO NOTES "w ft "m awo, w MIIIE mw4mmm""w EA&4 wwm am Musa +w" It � I !tr!'!re "w" 11. DIY a Yom, am" %f EXISTING SIRE ALARM TO REMAIN 1. FIRE ALARM SYSTEM SHALL BE POWER LIMITED. 2. WIRING SHALL BE #12 THHN, #14 THHN OR 18/2 TWISTED SHIELDED PAIR FPL TYPE CABLE. 3. INSTALLATI ❑N SHALL COMPLY WITH NFPA 1, 2003, APPLICABLE CHAPTERS. 4. INSTALLATION SHALL COMPLY WITH NFPA 72, 2'002, APPLICABLE CHAPTERS. 5. INSTALLATION SHALL COMPLY WITH NFPA 101, 2003, APPLICABLE CHAPTERS. 6. INSTALLATION SHALL COMPLY WITH NEC 2002 7. CONDUIT, AS APPLICABLE SHALL BE 1/2' MINIMIUM WITH A MAXIMUM FILL OF 40%. COMPLY WITH NEC. B. SYSTEM SHALL BE GROUNDED PER MANUFACTURERS SPECIFICATI ❑NS. 9. ALL DEVICES SHALL BE COMPATIBLE L SHALL BE UL LISTED FOR FIRE SERVICE USE. 10. ALL SPACES SHALL MEET THE AUDIBLE CHARACTRISTICS OF NFPA 72 AND NFPA 101. 11. SMOKE DETECTORS SHALL NOT BE LOCATED WI'rHIN 3' OF A/C DIFFUSERS, KITCHEN OR BATHROOM DOORS. 12. CEILING MOUNTED DEVICES SHALL BE LOCATED AT A HEIGHT OF 10' +/- ON SMOOTH FLAT CEILINGS UNLESS OTHERWISE NOTED. 13. SIGNALLING LINE CIRCUITS SHALL HAVE A MAXIMUM OF 250 POINTS PER CHANNEL. SEE FLOOR PLANS FOR QUANTITIES L TYPES OF DEVICES. 14. FIRE ALARM PANEL L ANY ASSOCIATED FIRE ALARM TRANSPONDERS SHALL BE FED BY A 120VAC, SINGLE PHASE, 20 AMP, DEDICATED BREAKER. 15. ALL INTERCONNECTED FIRE ALARM PANELS SHALL BE ARRANGED TO FUNCTION AS A SINGLE SYSTEM AND SHALL BE MONIT ❑RED FOR INTEGRITY PER NFPA 72. 16. RACKS, SHELVES AND EQUIPMENT ARE ALL L❑ \WER THAN 80' ABOVE FINISHED FLOOR UNLESS OTHERWISE INDICATED. 17. THE DESIGN INSTALLATION COMPLIES WITH F.B.C. 11- 4.287.3 18. THE BUILDING HAS A BACK UP GENERATOR 19. PREMISES HAS A 24 HOURS MANNED CENTRAL t� ❑NTROL STATION 20. THIS SYSTEM SHALL BE A LOCAL FIRE ALARM SIGNALING SYSTEM. UPON ACTIVATION OF ANY MANUAL STATION THE F'OLL❑WING SHALL OCCURI 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SI :LENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET, 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP L REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS SUPERVISING STATION VIA DACT, UPON ACTIVATION OF ANY AUTOMATIC DEVICE THE: F ❑LL ❑WING SHALL OCCURI 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP L REMOTE ANNUNCIAT ❑R. 4. A SIGNAL SHALL BE SENT TO THE OWNERS aUPERVISING STATION VIA DACT. 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. UPON ACTIVATION OF THE ELEVATOR LOBBY SMOKE DETECTORS (WITH THE EXCEPTION OF THE ELEVATOR LOBBY DETECTOR AT THE PRIMARY LEVEL OF EGRESS), THE FOLL ❑WING SHALL OCCUR, 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP L REMOTE ANNUNCIAT ❑R. 4. A SIGNAL SHALL BE SENT TO THE OWNERS SUPERVISING STATI ❑N VIA DACT. 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. 6. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. 7. FIREHAT IN ELEVATOR CAB SHALL ILLUMINATE. UPON ACTIVATION OF THE ELEVATOR LOBBY SMOKE DETECTOR AT THE PRIMARY LEVEL OF EGRESS, THE FOLLOWING SHALL OCCUR, 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP L REMOTE ANNUNCIAT ❑R, 4. A SIGNAL SHALL BE SENT TO THE OWNERS 1UPERVISING STATION VIA DACT, 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. 6. ELEVATORS SHALL RECALL TO THE ALTERNATE LEVEL OF EGRESS. 7. FIREHAT IN ELEVATOR CAB SHALL ILLUMINA7rE. UPON ACTIVATION OF THE ELEVATOR MACHINE R 017M SMOKE DETECTOR, THE FOLLOWING SHALL ❑CCURt 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP L REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS SUPERVISING STATION VIA DACT. 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. 6. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. 7. FIREHAT IN ELEVATOR CAB SHALL BLINK. UPON ACTIVATION OF THE ELEVATOR TOP OF SHAFT SMOKE DETECTOR, THE FOLLOWING SHALL ❑CCURi 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SI:LENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP L REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS SUPERVISING STATION VIA DACT, 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. 6. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. 7. FIREHAT IN ELEVATOR CAB SHALL BLINK. UPON ACTIVATI ❑N OF A WATERFL ❑W SWITCH, THE FOLL ❑WING SHALL OCCUR. 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP L REMOTE ANNUNCIAT ❑R. 4. A SIGNAL SHALL BE SENT TO THE OWNERS SUPERVISING STATION VIA DACT. 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. UPON ACTIVATI ❑N OF A TAMPER SWITCH, THE FOLLOWING SHALL OCCUR. 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP L REMOTE ANNUNCIAT ❑R. 2. A SUPERVISORY SIGNAL SHALL BE SENT TO THE OWNERS SUPERVISING STATION VIA DACT. UPON ACTIVATION OF A DUCT SMOKE DETECTOR, T-HE FOLL ❑WING SHALL OCCUR. 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP L REMOTE ANNUNCIATOR. 2. A SUPERVISORY SIGNAL SHALL BE SENT TO THE OWNERS SUPERVISING STATION VIA DACT. 3. THE AIR HANDLER UNIT ASSOCIATED WITH TliAT DUCT DETECTOR SHALL SHUT DOWN. 4. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND THE ASSOCIATED FIRE SMOKE DAMPERS SHALL ACTIVATE. w w W r� Z Q � w m u- C) N W N W 04 N M QU� U i Q q r �MMco 4 o¢L o z LO w a. nit r- a u a- w V z cn J � w; ZW Zw a� w LLj C0 U) w C> _j o� Z z a w U w W IL d 0 ° z 0 0 in w w U) w o o 0 Z Lu w I-- N � 5 w Lil �CLL Z O 124 8 J m i z 0 Z 0 U .. LL W w U 0 wLL � LL 0 o a� o(D h < o� t� r 7-o �Z Z O O U �Z Z w .r � Z �.� 0 Z �+ z z w U1 0 F- P �0 Z.0.� U US w o= 0 Z~ z `2 LL Z� w .� Z � z C04 r ��� �« DRAWN NY: DATE: KW 1/13/09 DESIGNED ■Y: , DATE: KW 1/13/09 APPROVED BY: DATE: PROJECT NUMBER: 940010209 SHEET NUMBER: DOTES SIZE: (24 "X36 ") SYMBOL LEGEND SYMBOL SIMPLEX MODEL # DESCRIPTION FRCP 4100 -9111 SIMPLEX 41000 (EXISTING) O 4902 -9721 TRUE ALERT SPEAKERS (CEILING MOUNTED) jpM mM■■ ONES 0 0 Non ■■ EMME■ 0MONS O■ MEMOS ■■ N■■■■ EMNO N Mom 0 SEMEN onE■■ ■■00 MEMOS ■NNNNN■■MENEM■■EHNEN■% MASS NOTIFICATION ■ ■ ■ ■ ■ NOT, r ■ ■ ■ 1. MASS NOTIFICATION SPEAKER WILL NOT WORK IN CONJUNCTION WITH FIRE ALARM SYSTEM HORNS. ■ ■ 2. IN THE EVENT OF A FIRE ALARM BEING ACTIVATED AND MASS NOTIFICATION IS NEEDED, MASS NOTIFICATION WILL OVERRIDE THE HORN OF FIRE ALARM AND SPEAKERS WILL BE ACTIVATED TO DIRECT INDIVIDUAL WITHIN FACILITY. ■ ■ UPON ACTIVATION HANDHELD MICROPHONE AT PANEL. ■ ■ 1. ALL SPEAKERS WILL BE ACTIVATED BY DESIGNATED FLOOR AT THE MAIN PANEL USING SWITCHES. ■ ■ ■ ■ ■ %■ EEN0 Oman MMENE■■■ NNONon ME■ MEM EME NS■■ NNRON0 MONO 0■■■ NON MENEM MENU soon NONE MENEM0MONSON■o man MEMO NOTES "w ft "m awo, w MIIIE mw4mmm""w EA&4 wwm am Musa +w" It � I !tr!'!re "w" 11. DIY a Yom, am" %f EXISTING SIRE ALARM TO REMAIN 1. FIRE ALARM SYSTEM SHALL BE POWER LIMITED. 2. WIRING SHALL BE #12 THHN, #14 THHN OR 18/2 TWISTED SHIELDED PAIR FPL TYPE CABLE. 3. INSTALLATI ❑N SHALL COMPLY WITH NFPA 1, 2003, APPLICABLE CHAPTERS. 4. INSTALLATION SHALL COMPLY WITH NFPA 72, 2'002, APPLICABLE CHAPTERS. 5. INSTALLATION SHALL COMPLY WITH NFPA 101, 2003, APPLICABLE CHAPTERS. 6. INSTALLATION SHALL COMPLY WITH NEC 2002 7. CONDUIT, AS APPLICABLE SHALL BE 1/2' MINIMIUM WITH A MAXIMUM FILL OF 40%. COMPLY WITH NEC. B. SYSTEM SHALL BE GROUNDED PER MANUFACTURERS SPECIFICATI ❑NS. 9. ALL DEVICES SHALL BE COMPATIBLE L SHALL BE UL LISTED FOR FIRE SERVICE USE. 10. ALL SPACES SHALL MEET THE AUDIBLE CHARACTRISTICS OF NFPA 72 AND NFPA 101. 11. SMOKE DETECTORS SHALL NOT BE LOCATED WI'rHIN 3' OF A/C DIFFUSERS, KITCHEN OR BATHROOM DOORS. 12. CEILING MOUNTED DEVICES SHALL BE LOCATED AT A HEIGHT OF 10' +/- ON SMOOTH FLAT CEILINGS UNLESS OTHERWISE NOTED. 13. SIGNALLING LINE CIRCUITS SHALL HAVE A MAXIMUM OF 250 POINTS PER CHANNEL. SEE FLOOR PLANS FOR QUANTITIES L TYPES OF DEVICES. 14. FIRE ALARM PANEL L ANY ASSOCIATED FIRE ALARM TRANSPONDERS SHALL BE FED BY A 120VAC, SINGLE PHASE, 20 AMP, DEDICATED BREAKER. 15. ALL INTERCONNECTED FIRE ALARM PANELS SHALL BE ARRANGED TO FUNCTION AS A SINGLE SYSTEM AND SHALL BE MONIT ❑RED FOR INTEGRITY PER NFPA 72. 16. RACKS, SHELVES AND EQUIPMENT ARE ALL L❑ \WER THAN 80' ABOVE FINISHED FLOOR UNLESS OTHERWISE INDICATED. 17. THE DESIGN INSTALLATION COMPLIES WITH F.B.C. 11- 4.287.3 18. THE BUILDING HAS A BACK UP GENERATOR 19. PREMISES HAS A 24 HOURS MANNED CENTRAL t� ❑NTROL STATION 20. THIS SYSTEM SHALL BE A LOCAL FIRE ALARM SIGNALING SYSTEM. UPON ACTIVATION OF ANY MANUAL STATION THE F'OLL❑WING SHALL OCCURI 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SI :LENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET, 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP L REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS SUPERVISING STATION VIA DACT, UPON ACTIVATION OF ANY AUTOMATIC DEVICE THE: F ❑LL ❑WING SHALL OCCURI 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP L REMOTE ANNUNCIAT ❑R. 4. A SIGNAL SHALL BE SENT TO THE OWNERS aUPERVISING STATION VIA DACT. 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. UPON ACTIVATION OF THE ELEVATOR LOBBY SMOKE DETECTORS (WITH THE EXCEPTION OF THE ELEVATOR LOBBY DETECTOR AT THE PRIMARY LEVEL OF EGRESS), THE FOLL ❑WING SHALL OCCUR, 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP L REMOTE ANNUNCIAT ❑R. 4. A SIGNAL SHALL BE SENT TO THE OWNERS SUPERVISING STATI ❑N VIA DACT. 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. 6. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. 7. FIREHAT IN ELEVATOR CAB SHALL ILLUMINATE. UPON ACTIVATION OF THE ELEVATOR LOBBY SMOKE DETECTOR AT THE PRIMARY LEVEL OF EGRESS, THE FOLLOWING SHALL OCCUR, 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP L REMOTE ANNUNCIAT ❑R, 4. A SIGNAL SHALL BE SENT TO THE OWNERS 1UPERVISING STATION VIA DACT, 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. 6. ELEVATORS SHALL RECALL TO THE ALTERNATE LEVEL OF EGRESS. 7. FIREHAT IN ELEVATOR CAB SHALL ILLUMINA7rE. UPON ACTIVATION OF THE ELEVATOR MACHINE R 017M SMOKE DETECTOR, THE FOLLOWING SHALL ❑CCURt 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP L REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS SUPERVISING STATION VIA DACT. 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. 6. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. 7. FIREHAT IN ELEVATOR CAB SHALL BLINK. UPON ACTIVATION OF THE ELEVATOR TOP OF SHAFT SMOKE DETECTOR, THE FOLLOWING SHALL ❑CCURi 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SI:LENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP L REMOTE ANNUNCIATOR. 4. A SIGNAL SHALL BE SENT TO THE OWNERS SUPERVISING STATION VIA DACT, 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. 6. ELEVATORS SHALL RECALL TO THE PRIMARY LEVEL OF EGRESS. 7. FIREHAT IN ELEVATOR CAB SHALL BLINK. UPON ACTIVATI ❑N OF A WATERFL ❑W SWITCH, THE FOLL ❑WING SHALL OCCUR. 1. ALL HORNS WILL SOUND UNTIL SYSTEM IS SILENCED. 2. ALL STROBES WILL FLASH UNTIL SYSTEM IS RESET. 3. AN ALARM SIGNAL SHALL BE SENT TO THE FACP L REMOTE ANNUNCIAT ❑R. 4. A SIGNAL SHALL BE SENT TO THE OWNERS SUPERVISING STATION VIA DACT. 5. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND FIRE SMOKE DAMPERS SHALL ACTIVATE. UPON ACTIVATI ❑N OF A TAMPER SWITCH, THE FOLLOWING SHALL OCCUR. 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP L REMOTE ANNUNCIAT ❑R. 2. A SUPERVISORY SIGNAL SHALL BE SENT TO THE OWNERS SUPERVISING STATION VIA DACT. UPON ACTIVATION OF A DUCT SMOKE DETECTOR, T-HE FOLL ❑WING SHALL OCCUR. 1. A SUPERVISORY SIGNAL SHALL BE SENT TO THE FACP L REMOTE ANNUNCIATOR. 2. A SUPERVISORY SIGNAL SHALL BE SENT TO THE OWNERS SUPERVISING STATION VIA DACT. 3. THE AIR HANDLER UNIT ASSOCIATED WITH TliAT DUCT DETECTOR SHALL SHUT DOWN. 4. ALL AIR HANDLER UNITS SHALL SHUT DOWN AND THE ASSOCIATED FIRE SMOKE DAMPERS SHALL ACTIVATE. w w W r� Z Q � w m u- C) N W N W 04 N M QU� U i Q q r �MMco 4 o¢L o z LO w a. nit r- a u a- w V z cn J � w; ZW Zw a� w LLj C0 U) w C> _j o� Z z a w U w W IL d 0 ° z 0 0 in w w U) w o o 0 Z Lu w I-- N � 5 w Lil �CLL Z O 124 8 J m i z 0 Z 0 U .. LL W w U 0 wLL � LL 0 o a� o(D h < o� t� r 7-o �Z Z O O U �Z Z w .r � Z �.� 0 Z �+ z z w U1 0 F- P �0 Z.0.� U US w o= 0 Z~ z `2 LL Z� w .� Z � z C04 r ��� �« DRAWN NY: DATE: KW 1/13/09 DESIGNED ■Y: , DATE: KW 1/13/09 APPROVED BY: DATE: PROJECT NUMBER: 940010209 SHEET NUMBER: DOTES SIZE: (24 "X36 ") 1 Ji 4 t r, �` iT 1 Ji 4 t r,