09-1110-020
W W w F- Q 0 800 KW 800 KW 800 KW 800 KW EMERGENCY EMERGENCY EMERGENCY EMERGENCY GENERATOR GENERATOR GENERATOR GENERATOR 38 38 38 38 ( 3P ( 3P ( 3P C3P 1200A \ 1200A \ 1200A \ 1200A 5000A 5000A EXISTING TO BE DEMOLISHED C 1200A ( 1200A ( 1200A SPACE ( 1200AF SPACE SPACE HP (5HP) 1200AT 100 +) 600 ) 1500 200) 400 ) 600 } 400 400 ) 225 } 1500 400 } 200 } 400) l � 600) 1000 } 600 ) 600 ) 600 225' 400;'l i 400 *1 800 *1 600) 600) 600 ) CONDUCTORS (3 PHASE, 4 WIRE) WITH GROUND NEW CONSTRUCTION FEEDER SYMBOL EXISTING TO BE DEMOLISHED x EF -6B HP (5HP) TYPE AMPS P i CHILLER #1 (402KVA) SPARE PUMP SHWP -1 (20HP) 4 *8 & 1 *10G. EF -6C (5HP) SPARE PUMP SHWP -2 (20HP) SPARE 314 60 4 *6 & 1 *10G. t t t 4 SPARE TO T( TO TO TO TO TO TO TO SPARE TO TO TO SPARE e TO TO TO LS CR -1 CR -2 EO TO TO ATS -E ATS -I NORTH NORTH ATS-4 ATS-9 ATS -2 ATS -3 ATS-8 NORTH ATS NORTH 4 *3 & 1 *8G. ATS -5 ATS -10 EDP4 ATS -11 ATS -12 TOWER TOWER TOWER TOWER 125 MAIN (ATS -1) FIRE (ATS -3) (ATS -2) 1 1/1 BLDG. 4 *1/0 & 1 *6G. PUMP 12 13 3 *2/0 & 1 *6G. 2' PARTIAL ELECTRICAL RISER DIAGRAM CONSTRUCTION LEGEND L DAIMON rNEVW- EXISTING TO REMAIN CONDUCTORS (3 PHASE, 4 WIRE) WITH GROUND NEW CONSTRUCTION FEEDER SYMBOL EXISTING TO BE DEMOLISHED x SECTION "1" SECTION "2" SECTION "3" SECTION "4" (1200A) (600A) (600A) (300A) MCCQ 48OY/277V,3PH,3W,1200A. M.L.O. MCCQ ELEVATION KEYED NOTES: O REMOVE ABANDONED 3P.125A CIRCUIT BREAKER AND PROVIDE NEW 3P,250A TYPE KC CIRCUIT BREAKER IN EXISTING CUBICLE. MODIFY EXISTING SQUARE D MODEL 5 MOTOR CONTROL CENTER AS NECESSARY. CUBICLE MADE SPARE BY DEMOLITION OF EXISTING COOLING TOWER *2. O PROVIDE ALL NEW PHENOLIC ENGRAVED NAMEPLATES FOR MCC INCLUDING EACH CUBICLE AND LABEL SPARES APPROPRIATELY. REMOVE EXISTING NAMEPLATES NO LONGER APPLICABLE. 3000A. BUS DUCT - TO FPL VAULT. 54,000A AVAILABLE FAULT CURRENT. NMSBI % 3000A 277/480V MOOOA NC 3PH, 4W ATS 6 LOAD SUMMARY EXISTING LOAD: 535.63 KVA LOAD REMOVED: (33.24 KVA) NEW LOAD ADDED: 129.64 KVA NEW TOTAL LOAD: 632.03 KYA 632.03KVA = 760A a 480V.3PH 3000A. BUS DUCT TO FPL VAULT. 54,OOOA AVAILABLE FAULT CURRENT. NMSB2 3000A 3000A 277/480V NC M2 3PH, 4W F NO -E1-> 3000A TI Iso�OA 40 1600A _ NSB2 1000) 36 36 ATS -6 1000A. 4P (EQUIP. SYS.) 34 36 EXISTING TO tE0HD3 i MCCQ 1 BE MODIFIED I i j EQUIP BRANCH 1 FEEDER SCHEDULE -� BASED ON N.E.C. TABLE 310 -16 FOR COPPER CONDUCTORS PUMP PIA (7.5HP) COOLING TOWER *2 01 EF -6A (5HP) NOMINAL AMPERE RATING CONDUCTORS (3 PHASE, 4 WIRE) WITH GROUND (125HP) FEEDER SYMBOL ❑C DEVICE EF -6B HP (5HP) TYPE AMPS P i CHILLER #1 (402KVA) SPARE PUMP SHWP -1 (20HP) 4 *8 & 1 *10G. EF -6C (5HP) SPARE PUMP SHWP -2 (20HP) SPARE 314 60 4 *6 & 1 *10G. In 4 SPARE CWP -5 1' 70 4 *4 & 1 *8G. INCOMING (50HP) SPARE SPARE SECTION 100 4 *3 & 1 *8G. 1 114 MCCQ 48OY/277V,3PH,3W,1200A. M.L.O. MCCQ ELEVATION KEYED NOTES: O REMOVE ABANDONED 3P.125A CIRCUIT BREAKER AND PROVIDE NEW 3P,250A TYPE KC CIRCUIT BREAKER IN EXISTING CUBICLE. MODIFY EXISTING SQUARE D MODEL 5 MOTOR CONTROL CENTER AS NECESSARY. CUBICLE MADE SPARE BY DEMOLITION OF EXISTING COOLING TOWER *2. O PROVIDE ALL NEW PHENOLIC ENGRAVED NAMEPLATES FOR MCC INCLUDING EACH CUBICLE AND LABEL SPARES APPROPRIATELY. REMOVE EXISTING NAMEPLATES NO LONGER APPLICABLE. 3000A. BUS DUCT - TO FPL VAULT. 54,000A AVAILABLE FAULT CURRENT. NMSBI % 3000A 277/480V MOOOA NC 3PH, 4W ATS 6 LOAD SUMMARY EXISTING LOAD: 535.63 KVA LOAD REMOVED: (33.24 KVA) NEW LOAD ADDED: 129.64 KVA NEW TOTAL LOAD: 632.03 KYA 632.03KVA = 760A a 480V.3PH 3000A. BUS DUCT TO FPL VAULT. 54,OOOA AVAILABLE FAULT CURRENT. NMSB2 3000A 3000A 277/480V NC M2 3PH, 4W F NO -E1-> 3000A TI Iso�OA 40 1600A _ NSB2 1000) 36 36 ATS -6 1000A. 4P (EQUIP. SYS.) 34 36 EXISTING TO tE0HD3 i MCCQ 1 BE MODIFIED I i j EQUIP BRANCH 1 FEEDER SCHEDULE -� BASED ON N.E.C. TABLE 310 -16 FOR COPPER CONDUCTORS FEEDER SYMBOL CONDUCTORS (3 PHASE. 3 WIRE) WITH GROUND RACEWAY SIZE CONDUIT NOMINAL AMPERE RATING CONDUCTORS (3 PHASE, 4 WIRE) WITH GROUND RACEWAY SIZE CONDUIT FEEDER SYMBOL ❑C DEVICE HP FLA TYPE AMPS P i 3 *8 & 1 *1 OG. 314 50 4 *8 & 1 *10G. 1' 2 3 3 *6 & 1 *10G. 314 60 4 *6 & 1 *10G. In 4 5 3 *4 & 1 *8G. 1' 70 4 *4 & 1 *8G. 1 114 6 7 3 *3 & 1 *8G. 1 1/d 100 4 *3 & 1 *8G. 1 114 8 9 3 *1 & 1 *6G. 1 1/1 125 4 *1 & 1 *6G. 2' 0 11 3 *1/0 & 1 *6G. 1 1/1 150 4 *1/0 & 1 *6G. 2' 12 13 3 *2/0 & 1 *6G. 2' 175 4 *2/0 & 1 *6G. 2' 14 15 3 *3/0 & 1 *6G. 2' 200 4 *3/0 & 1 *6G. 2' 16 17 3 *4/0 & 1 *4G. 2' 225 4 *4/0 & 1 *4G. 2 1/¢ 18 19 3 *250 KCMIL & 1 *4G. 2 1/1 250 4 *250 KCMIL & 1 *4G. 2 1/¢ D 21 3 *350 KCMIL & 1 *4G. 3' 300 4 *350 KCMIL & 1 *4G. 3' 2 3 3 *500 KCMIL & 1 *3G. 3 1/1 350 4 *500 KCMIL & 1 *3G. 3 1/¢ 4 5 3 *600 KCMIL & 1 *3G. 3 1/1 400 4 *600 KCMIL & 1 *3G. 4' 7 6 *250 KCMIL & 2 *2G. 2-2 W 500 8 *250 KCMIL & 2 *2G. 2 -2 SPARE 9 6 *350 KCMIL & 2 *1G. 2-3' 600 8 *350 KCMIL & 2 *1G. 2 -3' 0 31 6 *500 KCMIL & 2 *1 /OG. 2-3' 700 8 *500 KCMIL & 2 *1 /OG. 2 -3 1/¢ 3 3 6 *600 KCMIL & 2 *1 /OG. 2-3 1/1 800 8 *600 KCMIL & 2 *1 /OG. 2 -4' 0 5 9 *400 KCMIL & 3 *2 /OG. 3 -3' 1000 12 *400 KCMIL & 3 *2 /OG. 3 -3' 1 7 9 *600 KCMIL & 3 *3 /OG. 3 -3 1/1 1200 12 *600 KCMIL & 3 *3 /OG. 3 -4' 9 12 *600 KCMIL & 4 *4 /OG. 4 -3 1/¢ 1600 16 *600 KCMIL & 4 *4 /OG. 4 -4' 41 15 *600 KCMIL & 5 *250G. 5-3 1/9 2000 20 *600 KCMIL & 5 *250G. 5 -4' 42 43 18 *600 KCMIL & 6 *350G. 6-3 1/¢ 2500 24 *600 KCMIL & 6 *350G. 6 -4' 44 45 21 *750 KCMIL & 7 *400G. 7-4' 3000 1 28 *750 KCMIL & 7 *400G. 7 -5' 46 47 27 *750 KCMIL & 9 *500G. 9-4' 4000 36 *750 KCMIL & 9 *500G. 9 -5' 48 NOTES: 1.600 KCMIL AND 750 KCMIL FEEDERS SHALL BE COORDINATED WITH PROPER TERMINATION WITH MAC ADAPTERS AS REQUIRED TO COORDINATE WITH STANDARD BREAKER LUG SIZES. 2. SEE SPECIFICATIONS FOR ACCEPTABLE CONDUCTOR TYPES. - -- -- 3 *250,1 *4G.IN 21 /¢C. F EXISTING COOLING TOWER *2 FOR CONNECTION TO VIBRATION SWITCH. REFER TO SHEET E2.1. VFD HP NEW DOLING WER *2 VFD PROVIDED WITH -OVERLOAD PROTECTION AND INTEGRAL DISCONNECT 3 *3/0.1 *4G.IN 21C. LUGS OR PROVIDED PANELi MCCQ ENCLOSURE, NEMA 1 MA I NS(A) i ML❑ BUS RAT I NG(A) i 1200 L ❑CAT I ❑Nl CEP MOUNT I NGi Free Standing W I R I NGl 3 -Ph, 4 -W W I THSTAND(A) i 65 000 FED FROMi VOLTAGEi 480Y/277 FAULT CURRENT(A) 33818 NO DESCRIPTION NOTES ❑C DEVICE HP FLA TYPE AMPS P 1 CHILLER #1 - 414.00 800 3 2A PUMP P l A 7.5 8.41 20 3 2B SPARE 2C SPARE NOTE 1 0 3 2D CWP -5 50 56.08 100 3 3A C❑ ❑LING TOWER #2 NOTE 2 125 156.00 250 3 3B SHWP -1 20 22.43 50 3 3C SHWP -2 20 22.43 50 3 3D SPARE 0 3 4A EF -6A 5 5.61 20 3 4B EF -66 5 5.61 20 3 4C EF -6C 5 5.61 20 3 4D SPARE 0 3 4E SPARE 0 3 4F SPARE 0 3 ALL CONNECTED KVA MAX PH AMPS TOTAL CONNECTED 578, 53 696. 2 TOTAL DEMAND 578.53 696.2 NOTE 1: CUBICLE MADE SPARE BY DEMOLITION OF EXISTING COOLING TOWER *2. NOTE 2: REMOVE EXISTING ABANDONED 3P,125A CIRCUIT BREAKER AND REPLACE WITH 3P,250A CIRCUIT BREAKER ZYZA t ` mi h ei -Tnc �6001Nest Hillsboro, Suite 300 D&.rfield Beach, FL 33441 " - (954) 421 -1260 FAX: (954) 421 -1466 www.ssr- inc.com Firm Certification - EB- 0000857 Alfred Eaquivel PE - 46863 Enk S. Walter PE - 63929 John E. Moulder PE - 33200 Mirl -A A. Steward PE - 66701 SSR JOB # 0932026.0 <z F- w z� wW UV � C0 W �� CL O W Mo LL z� �Q 0 0 F- cmF- � Z Cl) � J �O O� �U DRAWN CHECKED DATE 12/04/09 REVISED SHEET N0. ELECTRICAL RISER DIAGRAM E3.01