08-957-024DEMOLITION NOTES: A. CONTRACTOR SHALL UPDATE ALL ELECTRICAL PANEL SCHEDULES AFFECTED BY THIS DEMOLITION. HAND WRITTEN SCHEDULES ARE NOT ACCEPTED. SCHEDULES SHALL BE TYPED OR COMPUTER GENERATED. B. PRIOR TO BID, THE EXTENT AND UNDERSTANDING OF THE WORK TO BE PERFORMED SHALL BE CLEARLY ESTABLISHED SUCH THAT NO ADDITIONAL COSTS WILL BE INCURRED BY THE OWNER. ANY WORK, OTHER THAN AS DESCRIBED ON ANY ITEM OR SYSTEMS SHALL BE QUALIFIED WITHIN THE BID. C. CONTRACTOR SHALL EXERCISE EXTREME CAUTION DURING DEMOLITION WORK. EXISTING FEEDERS AND PANELS ARE SHOWN SCHEMATIC FOR REFERENCE PURPOSES ONLY. CONTRACTOR SHALL VERIFY IN FIELD ROUTING OF ALL EXISTING FEEDERS PRIOR TO DEMOLITION. D. CONTRACTOR SHALL PROVIDE TEMPORARY POWER, LIGHTING, COMM., ETC., WHERE REQUIRED DURING DEMOLITION AND CONSTRUCTION SCOPE OF WORK. E ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR AND SHALL BE COORDINATED WITH OTHER TRADES. F. CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILITY FOR THE DURATION OF THE WORK. G. CONTRACTOR SHALL PAY FOR THE PERMITS, FEES & INSPECTIONS. H. CONTRACTOR SHALL NOT DISRUPT SERVICE TO ELECTRICAL APPURTENANCES TO REMAIN. I. ALL CIRCUITS SHOWN ARE FOR REFERENCE PURPOSES ONLY. CONTRACTOR SHALL VERIFY ALL CIRCUITS TO BE REMOVED PRIOR TO COMMENCEMENT OF WORK. J. THE CONTRACT DOCUMENTS DO NOT PROPOSE TO SHOW ALL EXISTING SYSTEMS, MATERIAL OR EQUIPMENT. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO OBTAIN DATA RELATED TO EXISTING CONDITIONS FROM EXISTING DOCUMENTS, NOTATIONS, PHOTOGRAPHS, SURVEYS AND OTHER OBSERVATIONS AT THE SITE. K. REMOVE EXISTING WIRE, CONDUIT, EQUIPMENT, FIXTURES AND OTHER ITEMS TO PROVIDE ACCESS FOR WORK IN EXISTING FACILITIES. REINSTALL AND REFINISH ITEMS REMOVED, OR OTHERWISE DAMAGED, TO MATCH EXISTING AT NO ADDITIONAL COST TO OWNER. L WHERE EXISTING FUNCTIONS TO REMAIN IN USE ARE DISRUPTED, THEY SHALL BE FULLY RESTORED AFTER DISRUPTION, IN FULL COMPLIANCE WITH APPLICABLE CODES AND STANDARDS. M. MODIFY , REMOVE, OR RELOCATE MATERIALS AND ITEMS INDICATED ON THE DRAWINGS OR REQUIRED DUE TO THE DEMOLITION WORK. N. WORK JOINTLY WITH THE ARCHITECT, ESTABLISH AND MARK SALVAGE AND DEMOUTION ITEMS BEFORE COMMENCING WORK; REPORT ITEMS SCHEDULE FOR RELOCATION, REINSTALLATION OR REUSE, WHICH ARE FOUND TO BE IN DAMAGED CONDITION; AWAIT FURTHER INSTRUCTIONS FROM THE ARCHITECT BEFORE COMMENCING PITH WORK. 0. DEMOUTION EQUIPMENT, DEVICES AND MATERIAL SHALL BE REMOVED FROM THE SITE AND DISPOSED OF BY THE CONTRACTOR. SALVAGED EQUIPMENT AND DEVICES SHALL BE THE PROPERTY OF THE OWNER UNLESS NOTED OTHERWISE. P. MAKE RELOCATION NECESSITATED BY THE CONDITIONS AT THE SITE OR AS DIRECTED BY THE ARCHITECT, WITHOUT ADDITIONAL COST TO THE OWNER. REPAIR, REPLACE AND /OR RESTORE TO GOOD FUNCTIONAL CONDITION, EQUIPMENT, MATERIAL AND ITEMS SCHEDULE FOR RELOCATION, WHICH ARE DAMAGED DURING DISMANTLING OR REASSEMBLE OPERATIONS PROVIDE NEW MATERIALS, FITTINGS AND APPURTENANCES REQUIRED TO COMPLETE THE RELOCATION AND TO RESTORE TO GOOD OPERATING ORDER. PERFORM THE RELOCATION WORK IN ACCORDANCE TO APPLICABLE CODES ASD STANDARDS, USING SKILLED WORKERS. Q. RELOCATING DEVICES: REMOVE AND REINSTALL IN LOCATIONS DESIGNATED BY THE ARCHITECT, TEMPERATURE CONTROL SYSTEM DEVICES, RELAYS, WIRE CONDUIT, FIXTURES, EQUIPMENT AND OTHER DEVICES REQUIRED FOR THE OPERATION OF THE VARIOUS SYSTEMS THAT ARE INSTALLED IN EXISTING TO BE REMOVED CONSTRUCTION. R. CONTRACTOR SHALL KEEP A CLEAN SET OF DRAWINGS ON THE JOB, NOTING DAILY, ALL CHANGES MADE IN THESE DRAWINGS IN CONNECTION WITH THE DEMOLITION PHASE, INCLUDING EXACT DIMENSIONED LOCATIONS OF ALL UNCOVERED EXISTING UTILITIES AND SHALL. WITH THIS, REQUEST FOR FINAL PAYMENT. TURN OVER A CLEAN, NEATLY MARKED SET OF REPRODUCIBLE MYLARS SHOWING "EXISTING CONDITIONS" WORK TO THE ARCHITECT FOR SUBSEQUENT RENEW AND TRANSMITTAL TO THE OWNER. CONTRACTOR SHALL NOTE ALL CONSTRUCTION CHANGES, DATE EACH AND LABEL "AS- BUILTS" IN THE REVISION BLOCK ON THE DRAWINGS. CONTRACTOR SHALL ALSO FURNISH ONE SET OF 'AS- BUILTS" BLUEPRINTS. S. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SUPPORTING OF EXISTING CONDUITS AND WIRING ABOVE CEILING SPACES WITHIN THE SCOPE OF THE PROJECT TO COMPLY WITH CURRENT CODES. PROVIDE A $5,000 ALLOWANCE FOR SUCH RESUPPORTING. ALL LABOR AND MATERIALS TO BE CHARGED TO ALLOWANCE SHALL BE DOCUMENTED AND APPROVED BY ENGINEER OR ARCHITECT PRIOR TO WORK. ANY ALLOWANCE NOT USED SHALL BE CREDITED TO OWNER. T. ANY EXISTING JUNCTION BOXES OR RACEWAYS WHICH WILL REMAIN AFTER DEMOLITION, SHALL IDENTIFY CIRCUIT AND BE COLOR CODED PER SPECIFICATIONS. PROVIDE COVER PLATED AS REQUIRED THROUGHOUT. U. ALL EXISTING COVER PLATES FOR RECEPTACLES AND SWITCHES REMAINING IN THE SCOPE OF WORK AREA AFTER DEMOUTION SHALL BE REPLACED WITH THE SAME COVER PLATES BEING USED FOR NEW WORK. PROVIDE ENGRAVING PER SPECIFICATIONS. V. ANY SWITCH OR RECEPTACLE THAT WILL REMAIN AFTER DEMOLITION IN THE SCOPE OF WORK AREA SHALL BE REPLACED WITH NEW SWITCHES AND OR RECEPTACLES. REFER TO SPECIFICATIONS. W. CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF THE EXISTING FIRE ALARM SYSTEM DURING CONSTRUCTION. X. ANY DATA/TELEPHONE OUTLET THAT WILL REMAIN AFTER DEMOLITION IN THE SCOPE OF WORK AREA SHALL BE REPLACED WITH TYPE USED FOR NEW WORK. REFER TO SPECIFICATIONS. KEYED NOTES: Ol DISCONNECT AND REMOVE ALL ELECTRICAL EQUIPMENT, DEVICES, CONDUITS AND WIRING BACK TO SOURCE; INCLUDING POWER AND SYSTEMS DEVICES IN THIS AREA U.N.O. ALL EXISTING RACEWAYS PASSING THROUGH THIS AREA THAT SERVE AREAS OUTSIDE THE SCOPE OF WORK SHALL REMAIN. PROVIDE SUPPORTS FOR THESE RACEWAYS IF THEY ARE NOT PROPERLY SUPPORTED. ALL OTHER RACEWAYS SHALL BE REMOVED. OEXISTING DEVICE TO BE REPLACED WITH NEW TYPE. REFER TO NEW WORK DRAWINGS FOR LOCATION AND REQUIREMENTS. (D EXISTING NURSE CALL DEVICE TO REMAIN. CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING PROPER OPERATION OF DEVICE IF NOT IN PROPER WORKING CONDITION PROVIDE NFW r)FVICF AS RFOUIRFIX. 0 S El u c PANEL 7E1 ------------------------------------ CL. I ' CLEAN I UTI L. I i i DESIQMr" II II r — -I PIXIS CART STO R. j i CC I j SITZ ____________ � ' III B i i C ° TREATMENT El �i L_ _j ------------------------- 3 O �"1 i SOIL. i UTI L. i I i El! I � r -� O O �F-HC I OPARTIAL 2SCALE: 114" = T -0" SEVENTH FLOOR — DEMOLITION E 2 DESIQMr" II II r — -I E)WNC TO BE FUOVED ____________ EXISTING TO REMAIN III B A E ROM C / .O L_ _j 3 O �"1 N CB I i i %_jit I � r -� C L _ J ,� 729A` TOILET N ON "�r E Cl 729 r - -- T PRIVATE MOM L_ 2 O IF _a LEGEND DESIQMr" L 1p6r PE E)WNC TO BE FUOVED ____________ EXISTING TO REMAIN � KEYPLAN CITY OF SOUTH MIAMI BUILDING DEPT. ELECTRICAL SECTION APPROVED BY:� DATE- l D cm —AREA OF IMPROVEMENT (5TH & 7H FLOOR) F FLOOR PLAN ol.SEVENTH SCALE: NTS fro co co O a ai C3 co UM cn • -I LL W WJ ❑ IoC ° g N N W r , F_- �/ V m 0 J Q � m J Q U W O U O N co C3 2 �- O M ti O m 3 co Q `rrn�ti000 O C-4 to rn ~ Ww 0 U M y cO jN0 u- "10 N- O��Che- O j N 0 0 N D 2 Z �, N v C7 u.u."0acnl -Q 1 ❑ Comm. No: 08061 M 07/07/08 Drawn: � C .O Ma C o LL "�r E C cc _a 0 CO co O m E ._ E c* 0 0 ca M 0 LM 0o O (L 0 CID V Comm. No: 08061 Date: 07/07/08 Drawn: Revised: 7l © 2008 HARVARD JOLLY,. �NC9 ED1.71