08-957-022
ELECTRICAL SYMBOLS ALL SYMBOLS SHOWN MAY NOT APPEAR IN ALL DRAWINGS. SYMBOLS ARE SHOWN SCHEMATIC AND MAY NOT BE TO SCALE. LIGHTING FIRE ALARM SYMBOL DESCRIPTION DEVICE MTG. HT. SYMBOL DESCRIPTION SEE FIXTURE On O 2x2 / 20 FLUORESCENT LIGHT FIXTURE ON NORMAL CIRCUIT. DESCRIPTION SCHEDULE 4" SQUARE BOX WITH SINGLE GANG ADAPTER FOR MICROPHONE OUTLET - STUB 3/4 C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX. ❑F FIRE ALARM PULL STATION $2 DOUBLE POLE TOGGLE SWITCH, 2OA/120/277V 2'x2' / 2'x4' FLUORESCENT LIGHT FIXTURE ON CRITICAL CIRCUIT. $3 sEE FIDUE 48' AFF Ell FIRE ALARM AUDIBLE/VISUAL SIGNAL 48' AFF $D WALL BOX DIMMER SWITCH 48" AFF $K KEY OPERATED WALL SWITCH 48' AFF $T • • 2'x2' / 2'x4' FLUORESCENT LIGHT FIXTURE ON LIFE SAFETY CIRCUIT. $3D SEE FIXTURE SCHEDULE 48' AFF E4 FIRE ALARM AUDIBLE SIGNAL ® 2'x4' FLUORESCENT LIGHT FIXTURE W/INBOARD LAMPS ON CRITICAL MOMENTARY WALL SWITCH, 20A, 120/277V SEE FIXTURE $Lv F FIRE ALARM VISUAL SIGNAL $0s CIRCUIT AND OUTBOARD LAMPS ON NORMAL CIRCUIT. 48' AFF SCHEDULE SYMBOL DESCRIPTION DEVICE MTG. HT. V WALL MOUNTED FIXTURE ON NORMAL CIRCUIT. 18" AFF U.N.O. SEE FIXTURE SCHEDULE DUPLEX RECEPTACLE - 20A/125V/2P/3W/G NEMA 5-20R 18' AFF U.N.O. FIRE ALARM SPRINKLER FLOW SWITCH DUPLEX RECEPTACLE GFl - 20A/125V/2P/3W/G NEMA 5-20R WALL MOUNTED FIXTURE ON CRITICAL CIRCUIT. TELEVISION SEE FIXTURE SCHEDULE 18' AFF U.N.O. UG FIRE ALARM SPRINKLER TAMPER SWITCH CFC= i WALL MOUNTED FIXTURE ON CRITICAL CIRCUIT. UNO (U.N.O.) SEE FIXTURE SCHEDULE 18' AFF U.N.O. ® FIRE ALARM SPRINKLER PRESSURE SWITCH 0 RECESSED /SUSPENDED DOWNLIGHT FIXTURE ON NORMAL CIRCUIT. DUPLEX RECEPTACLE GFl - 20A/125V/2P/3W/G NEMA 5-20R WITH WEATHERPROOF ENCLOSURE SEE FIXTURE SCHEDULE Lp,GFl �WW D D SMOKE DETECTOR CEILING OR WALL MOUNTED 0 RECESSED /SUSPENDED DOWNLIGHT FIXTURE ON CRITICAL CIRCUIT. _ SEE FIXTURE SCHEDULE DUPLE( RECEPTACLE - 20A/125V/2P/3W/G NEMA 5-20R CEILING MOUNTED - FLUSH MOUNTED UNO O Fe HEAT DETECTOR CEIUNG OR WALL MOUNTED 0 RECESSED /SUSPENDED DOWNLIGHT FIXTURE ON LIFE SAFETY CIRCUIT. Q F QJ SEE FIXTURE - - - ==I D - DUCT SMOKE DETECTOR - min:] PANELBOARD - SURFACE MOUNTED SCHEDULE EFF"i PANELBOARD - FLUSH MOUNTED 72" TO TOP 0 RECESSED DOWNLIGHT FIXTURE WITH WALL WASH TRIM. +54' U.N.O. SEE FIXTURE SCHEDULE DISCONNECT SWITCH - 30/3/ * /1. INDICATES 30A, 3 -POLE, FUSE SIZE. NEMA TYPE, F DENOTES FUSIBLE SWITCH �/� QS ��/ FIRE ALARM SPEAKER CEILING OR WALL MOUNTED 8 CEILING OR WALL MOUNTED EXIT SIGN. SHADING INDICATES DOUBLE OR CB si Ep SEE FIXTURE AS REQUIRED $M SMOKE DOOR MECHANICAL HOLD OPEN, CONNECT TO FIRE ALARM AS REQUIRED SINGAL FACE. ARROWS INDICATE CHEVRON DIRECTIONS. MOTOR SCHEDULE �_D EPO EMERGENCY POWER OFF BUTTON. WALL MOUNTED - STUB 31e C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX SYSTEM - STUB 3/4' C. ABOVE ACCESSIBLE CEILING FROM OUTLET u WALL MOUNTED 90- MINUTE BATTERY - POWERED EGRESS LIGHTING. - SEE FIXTURE MULTI -POLE DEVICE CIRCUIT NUMBERS FACP FIRE ALARM CONTROL PANEL HOMERUN CONDUIT MINIMUM 4 U.N.O. (NUMBER OF ARROWHEADS INDICATE QUANTITY OF #12 PHASE CONDUCTORS). PROVIDE ONE 112 GROUND AND ONE #12 NEUTRAL IN EACH CONDUIT U.N.O. MAXIMUM OF _ SCHEDULE Q,O EXTERIOR POLE MOUNTED AREA LUMINAIRE. ARROW INDICATES DIREC11ON OF 120 SEE FIXTURE MULTI FUNCTION PATIENT LIGHT FF—AA-P-1 FIRE ALARM ANNUNCIATOR PANEL LIGHTING SYSTEMS PHOTOMETRIC OPTIC ROTATION. SCHEDULE NURSE/READING Q MT1F- 1007- 1- E -1 -SW TRACK LIGHTING SEE FIXTURE I TELEPHONE JACK FOR FIREMAN'S PHONE (BY FIRE ALARM DAYBRITE (2) Fl 4T5 120 SCHEDULE 2' X 2' FLUORESCENT CONTRACTOR) SWITCHES SYMBOL DESCRIPTION DEVICE MTG. HT. 4" SQUARE BOX WITH SINGLE GANG ADAPTER FOR MICROPHONE OUTLET - STUB 3/4 C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX. WALL SWITCH SPST, 20A, 120/277V 48' AFF $2 DOUBLE POLE TOGGLE SWITCH, 2OA/120/277V 48" AFF $3 3 -WAY WALL SWITCH, 20A, 120/277V 48' AFF $4 4 -WAY WALL SWITCH, 20A, 120/277V 48' AFF $D WALL BOX DIMMER SWITCH 48" AFF $K KEY OPERATED WALL SWITCH 48' AFF $T WALL SWITCH WITH ADJUSTABLE COUNTDOWN TIMER 48" AFF $3D 3 -WAY WALL DIMMER SWITCH, 20A, 120/277V 48' AFF $3K 3 -WAY, KEY OPERATED WALL SWITCH, 20A, 120/277V 48' AFF $mc MOMENTARY WALL SWITCH, 20A, 120/277V 48' AFF $Lv LOW VOLTAGE WALL SWITCH 48' AFF $0s WALL MOUNTED OCCUPANCY SENSOR SWITCH 48' AFF WIRING DEVICES & POWER SYMBOL DESCRIPTION DEVICE MTG. HT. & SINGLE RECEPTACLE - 20A/125V/2P/3W/G NEMA 5-20R 18" AFF U.N.O. TELEPHONE DUPLEX RECEPTACLE - 20A/125V/2P/3W/G NEMA 5-20R 18' AFF U.N.O. TP DUPLEX RECEPTACLE GFl - 20A/125V/2P/3W/G NEMA 5-20R 8" ABOVE COUNTERTOP U.N.O. TELEVISION DUPLEX RECEPTACLE GFl - 20A/125V/2P/3W/G NEMA 5-20R 18' AFF U.N.O. UG DUPLEX RECEPTACLE GFl - 20A/125V/2P/3W/G NEMA 5-20R 8" ABOVE COUNTERTOP U.N.O. UNIT HEATER UNO (U.N.O.) QUADRAPLEX RECEPTACLE TWO DUPLEX RCPTS. UNDER ONE COVERPLATE 18' AFF U.N.O. VOLTAGE QUADRAPLEX RECEPTACLE TWO DUPLEX RCPTS. UNDER ONE COVERPLATE 8" ABOVE COUNTERTOP U.N.O. aGFl G5� DUPLEX RECEPTACLE GFl - 20A/125V/2P/3W/G NEMA 5-20R WITH WEATHERPROOF ENCLOSURE 18' AFF U.N.O. Lp,GFl �WW DUPLEX RECEPTACLE GFl - 20A/125V/2P/3W/G NEMA 5-20R WITH WEATHERPROOF ENCLOSURE - ROOF MOUNTED 18' AFF U.N.O. 0 DUPLEX RECEPTACLE - 20A/125V/2P/3W/G NEMA 5-20R FLOOR MOUNTED - FLUSH MOUNTED UNO _ WEATHER PROOF DUPLE( RECEPTACLE - 20A/125V/2P/3W/G NEMA 5-20R CEILING MOUNTED - FLUSH MOUNTED UNO _ E) SPECIAL PURPOSE RECEPTACLE (NEMA NO. AS INDICATED) 18' AFF U.N.O. Q F QJ JUNCTION BOX - SIZE AND MOUNTING AS REQUIRED - :m=mc= MULTIOUTLET ASSEMBLY - LENGTH AND OUTLET SPACING AS INDICATED - min:] PANELBOARD - SURFACE MOUNTED 7Y TO TOP EFF"i PANELBOARD - FLUSH MOUNTED 72" TO TOP © 30/3 CIRCUIT BREAKER DISCONNECT SWITCH - THERMAL MAGNETIC CB IN NEMA 1 ENCLOSURE U.N.O.• AMPS /POLES AS INDICATED +54' U.N.O. ❑F ❑- �/3/s/1 DISCONNECT SWITCH - 30/3/ * /1. INDICATES 30A, 3 -POLE, FUSE SIZE. NEMA TYPE, F DENOTES FUSIBLE SWITCH +54" U.N.O. ®2 MOTOR STARTER FVNR UNO; NUMBER INDICATES NEMA SIZE AS REQUIRED CB si Ep COMBINATION MOTOR CONTROLLER/DISCONNECT SWITCH AS REQUIRED $M MANUAL MOTOR STARTER SWITCH WITH THERMAL OVERLOAD AND PILOT LIGHT AS REQUIRED (4) F40BX MOTOR - �_D EPO EMERGENCY POWER OFF BUTTON. WALL MOUNTED - STUB 31e C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX 48. AFF X,X,X THREE SINGLE POLE DEVICE CIRCUIT NUMBERS - X/X/X MULTI -POLE DEVICE CIRCUIT NUMBERS - _ HOMERUN CONDUIT MINIMUM 4 U.N.O. (NUMBER OF ARROWHEADS INDICATE QUANTITY OF #12 PHASE CONDUCTORS). PROVIDE ONE 112 GROUND AND ONE #12 NEUTRAL IN EACH CONDUIT U.N.O. MAXIMUM OF _ FPAP FCP FATC SYMBOL r h s s m m m C SYMBOL ❑N 0 2 R CB EP D EP BI RL NCS NCC NSS rte. r -W-1A SYMBOL FIRE PUMP ANNUNCIATOR PANEL DEVICE MTG. HT. 48'AFF )' TO THE BOTTOM OF THE OR 6" BELOW FINISHED CEII )" TO THE BOTTOM OF THE OR 6" BELOW FINISHED CO )" TO THE BOTTOM OF THE OR 6" BELOW FINISHED CEII 48' AFF FIREFIGHTER'S CONTROL PANEL FIRE ALARM TERMINAL CABINET TELEPHONE /DATA DESCRIPTION 4' SQUARE BOX WITH SINGLE GANG ADAPTER FOR TWO TELEPHONE OUTLETS . STUB 314' C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX. 4' SQUARE BOX WITH SINGLE GANG ADAPTER FOR ONE DATA OUTLET. STUB 3/4" C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX. 4" SQUARE BOX WITH SINGLE GANG ADAPTER FOR TWO TELEPHONE OUTLETS AND ONE DATA OUTLET. STUB 3/4' C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX. 4' SQUARE BOX WITH SINGLE GANG ADAPTER FOR TWO TELEPHONE OUTLETS AND TWO DATA OUTLETS . STUB 314" C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX. 4' SQUARE BOX WITH SINGLE GANG ADAPTER FOR ONE WALL MOUNTED TELEPHONE OUTLET. STUB 3/4" C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX. PAY PHONE TELEPHONE OUTLET. STUB 314' C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX. 4' SQUARE BOX W/ SINGLE GANG ADAPTER FOR DATA OUTLET(S). "X' INDICATES 11` OF OUTLETS. STUB 3/4" C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX. 4' SQUARE BOX WITH SINGLE GANG ADAPTER FOR PATIENT MONITOR OUTLET FOR TELEMETRY SYSTEM - STUB 3/4 C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX. 4' SQUARE BOX WITH SINGLE GANG ADAPTER (UNO) FOR VENDOR SUPPLIED CABLE AND OUTLET - STUB 3/4 C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX. STACKED DATA OUTLET BOXES OR THE LIKE THAT SHARE 3/4' C. STUB UP. NURSE CALL DEVICE MTG. HT. 18' AFF 18" AFF 18' AFF 18" AFF 48" AFF 48' AFF 18" AFF 60' AFF 18' AFF 18' AFF 30" AFF DESCRIPTION I DEVICE MTG. HT. SINGLE PATIENT STATION DUAL PATIENT STATION AUDIO STATION WITH CODE BLUE AND STAFF ASSIST EMERGENCY PULL CORD STATION WATERPROOF PULL CORD STATION FOR SHOWER BED INTERFACE REMOTE LOCATOR NURSE CALL MASTER STATION NURSE CALL EQUIPMENT CABINET NURSE CALL SLAVE STATION DOMEUGHT ZONE LIGHT MISCELLANEOUS SYSTEMS DESCRIPTION AN SQUARE BOX WITH SINGLE GANG ADAPTER FOR CAN SYSTEM OUTLET - STUB 46' AFF 46' AFF 46' AFF 46' AFF 78" AFF HEADWALL CEUNG CEILING OR 4' ABOVE DOOR CEILING OR 4' DEVICE MTG. HT. AIC AFC AFF An BFC BOF C' CB,C /B OR CKT BKR CKT CCTV CLG CUH DFA EC ELEC E EMS EP EWC EX F FA FACP, FAP FCU FIXT FLR FLUOR FTP, FTS FTU G. GND GEF GEN GFCI, GFl HP HV HWAT IC ICAND IG JB KEF LTG LTS LV MAN MCB MCC MDP MH MLO MTD ELECTRICAL ABBREVIATIONS AMPERE INTERRUPTING CAPACITY AVAILABLE FAULT CURRENT ABOVE FINISHED FLOOR AUTOMATIC TRANSFER SWITCH BELOW FINISHED CEILING BOTTOM OF FIXTURE CONDUIT CIRCUIT BREAKER CIRCUIT CLOSED CIRCUIT T.V. CEILING CABINET HEATER DOWN FROM ABOVE EMPTY CONDUIT ELECTRIC EMERGENCY - RED ENERGY MANAGEMENT SYSTEM EXPLOSION PROOF ELECTRIC WATER COOLER EXISTING FUSE FIRE ALARM FIRE ALARM CONTROL PANEL FAN COIL UNIT FIXTURE FLOOR FLUORESCENT FAN TERMINAL UNIT FAN TERMINAL UNIT GROUND (EQUIPMENT) GENERAL EXHAUST FAN GENERATOR GROUND FAULT CIRCUIT INTERRUPTER HORSE POWER HIGH VOLTAGE HEAT TRACE INTERRUPTING CAPACITY INCANDESCENT ISOLATED GROUND JUNCTION BOX KITCHEN EXHAUST FAN LIGHTING LIGHTS LOW VOLTAGE MASTER ANTENNA MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MAIN DISTRIBUTION PANEL MANHOLE MAIN LUGS ONLY MOUNT OR MOUNTED N 3/4 C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX. 18' AFF NORMALLY CLOSED 4" SQUARE BOX WITH SINGLE GANG ADAPTER FOR MICROPHONE OUTLET - STUB 3/4 C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX. 18 AFF IC 4" SQUARE BOX WITH SINGLE GANG ADAPTER FOR INTERCOM OUTLET - STUB 3/4 C. ABOVE ACCESSIBLE CEIUNG FROM OUTLET BOX. 480 AFF NOT IN CONTRACT 4' SQUARE BOX WITH SINGLE GANG ADAPTER FOR ELECTRONIC CARD READER - STUB 3/4 C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX. 48• AFF PO 4" SQUARE BOX WITH SINGLE GANG ADAPTER FOR PUSH PLATE TO POWER OPERATED DOOR. 41f AFF rIJ 4' SQUARE BOX WITH SINGLE GANG ADAPTER FOR ELECTRONIC KEY PAD - STUB 3/4 C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX. 4e AFF FOS OO P.A. SPEAKER - CEILING OR WALL MOUNTED. STUB 314' C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX. 46 AFF PANEL 4" SQUARE BOX WITH SINGLE GANG ADAPTER FOR WALL MOUNTED VOLUME CONTROL BOX. STUB 314" C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX. 48• AFF zPP POWER POLE WITH VOICE/DATA CAPABITIES - FA-P-1 WIRELESS ACCESS POINT CEUNG MOUNTED - CCTV CLOSED CIRCUIT VIDEO SURVEILLANCE CAMERA - PTZ CCTV CLOSED CIRCUIT SECURITY CAMERA - PAN/TILT/ZOOM - I$ TELEVISION SYSTEM TAP OFF OUTLET. 18' AFF U.N.O. AIC AFC AFF An BFC BOF C' CB,C /B OR CKT BKR CKT CCTV CLG CUH DFA EC ELEC E EMS EP EWC EX F FA FACP, FAP FCU FIXT FLR FLUOR FTP, FTS FTU G. GND GEF GEN GFCI, GFl HP HV HWAT IC ICAND IG JB KEF LTG LTS LV MAN MCB MCC MDP MH MLO MTD ELECTRICAL ABBREVIATIONS AMPERE INTERRUPTING CAPACITY AVAILABLE FAULT CURRENT ABOVE FINISHED FLOOR AUTOMATIC TRANSFER SWITCH BELOW FINISHED CEILING BOTTOM OF FIXTURE CONDUIT CIRCUIT BREAKER CIRCUIT CLOSED CIRCUIT T.V. CEILING CABINET HEATER DOWN FROM ABOVE EMPTY CONDUIT ELECTRIC EMERGENCY - RED ENERGY MANAGEMENT SYSTEM EXPLOSION PROOF ELECTRIC WATER COOLER EXISTING FUSE FIRE ALARM FIRE ALARM CONTROL PANEL FAN COIL UNIT FIXTURE FLOOR FLUORESCENT FAN TERMINAL UNIT FAN TERMINAL UNIT GROUND (EQUIPMENT) GENERAL EXHAUST FAN GENERATOR GROUND FAULT CIRCUIT INTERRUPTER HORSE POWER HIGH VOLTAGE HEAT TRACE INTERRUPTING CAPACITY INCANDESCENT ISOLATED GROUND JUNCTION BOX KITCHEN EXHAUST FAN LIGHTING LIGHTS LOW VOLTAGE MASTER ANTENNA MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MAIN DISTRIBUTION PANEL MANHOLE MAIN LUGS ONLY MOUNT OR MOUNTED N NEW DEVICE NC (N.C.) NORMALLY CLOSED NEC NATIONAL ELECTRIC CODE NF NONFUSED NIC NOT IN CONTRACT NL NIGHT LIGHT NO (N.O.) NORMALLY OPEN (ON) HOME RUN FOR CKT IS 'ON" THE SAME E2.71 CKT. ELSEWHERE ON THE PLAN PB PULL BOX PNL PANEL PWR POWER R RELOCATED DEVICE RCPT(S) OR RECEPTACLE(S) RECEPT ELECTRICAL SPECIFICATIONS RF RETURN AIR FAN SEF SMOKE EXHAUST FAN SF SUPPLY AIR FAN SO (S.O.) SPACE ONLY SP SPARE ST (S.T.) SHUNT TRIP SW SWITCH TC TIME CLOCK TEL TELEPHONE TF TRANSFER FAN TP TAMPER PROOF TV TELEVISION OF UNDERFLOOR UG UNDERGROUND UH UNIT HEATER UNO (U.N.O.) UNLESS NOTED OR INDICATED OTHERWISE V VOLTAGE VP VAPOR PROOF VV VARIABLE VOLUME UNIT W WIRE W/ WITH WG WIRE GUARD WP WEATHER PROOF WT WATER TIGHT XFMR TRANSFORMER +xx MOUNTING HEIGHT IN INCHES. AFF UNO. NOTES: 1. 48" AFF INDICATES TO TOP OF DEVICE; 18" AFF INDICATES TO BOTTOM OF DEVICE; 80" AFF INDICATES TO BOTTOM OF DEVICE; ALL OTHER MOUNTING HEIGHTS REFER TO CENTERLINE OF DEVICE. MISCELLANEOUS Q- NOTES: DENOTES 'SEE NOTE NO. 2" E:lr- MARK (ID) NUMBER FOR EQUIPMENT REF. 2/82.02 - DENOTES: REFERENCE DETAIL 2 IN DRAWING (SHEET) E2.02 XX -XX PANEL AND CIRCUIT NOTE: THESE INFORMATION MAY NOT ALWAYS BE INDICATED IN THE FORMAT �a —SWITCHING DESIGNATION SHOWN, DUE TO SPACE RESTRICTIONS IN X --*—FIXTURE TYPE THE FLOOR PLAN, ELECTRICAL SHEET LIST G N o DRAWING TITLE SCALE EO.00 ELECTRICAL LEGEND, SHEET LIST, RISER AND NOTES NTS ED1.51 FIFTH FLOOR DEMOLITION AND REFERENCE LOCATION PLAN SEE DRAWING ED1.71 SEVENTH FLOOR DEMOLITION AND REFERNCE LOCATION PLAN 114 "=1' E2.51 FIFTH FLOOR LIGHTING, POWER AND SYSTEMS 1/4 " =1' E2.71 SEVENTH FLOOR LIGHTING, POWER AND SYSTEMS 1/4 " =1' E3.00 ONE -LINE ELECTRICAL DIAGRAM NTS E4.00 ELECTRICAL PANEL SCHEDULES NTS E5.00 ELECTRICAL STUDIES AND DETAILS NTS E6.00 ELECTRICAL SPECIFICATIONS CAPRI GENERAL NOTES: A. NOT USED. B. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE SITE AND EXAMINE IN DETAIL THE SCOPE OF WORK OF THIS PROJECT PRIOR TO BID AND SHALL NOTIFY THE ARCHITECT AND /OR ENGINEER IF A CONDITION EXISTS WHICH PREVENTS HIM/HER FROM ACCOMPLISHING THE WORK INDICATED AND INTENDED BY THESE DRAWINGS, SO NO ADDITIONAL COST IS INCURRED BY THE OWNER. AFTER CONTRACT IS AWARDED IT WILL BE ASSUMED THAT THE SITE WAS VISITED AND EXAMINED AND ALL PARTIES ARE IN AGREEMENT WITH THE SCOPE OF THE WORK. C. CONTRACTOR SHALL PATCH /RESTORE ALL WALL/FLOOR PENETRATIONS AS REQUIRED TO MAINTAIN/RESTORE ORIGINAL FIRE RATING. D. CONTRACTOR SHALL PROVIDE AND INSTALL AN IDENTIFICATION NAMEPLATE FOR EACH ELECTRICAL EQUIPMENT /APPURTENANCE DEPICTING THE DESIGNATION INDICATED ON THE DRAWINGS. E. ALL EMPTY CONDUIT SYSTEMS SHALL CONTAIN A PULL WIRE FOR FUTURE PULLING OF CONDUCTORS. F. CONTRACTOR SHALL COORDINATE ALL REQUIRED ENERGY MANAGEMENT SYSTEM POINTS AND CONTACT CONNECTIONS TO ENSURE THE COMPLETE AND PROPER OPERATION OF ALL SYSTEMS. G. CONTRACTOR SHALL PROVIDE AND INSTALL A 1" CONDUIT W/PULL WIRE FROM EACH WALL MOUNTED TELEPHONE AND /OR DATA OUTLET STUB UP 6" ABOVE FINISHED CEILING OR NEAREST ACCESSIBLE CEILING SPACE. H. THE CONTRACTOR SHALL COORDINATE WITH OTHER TRADES ALL NECESSARY WIRING AND CONNEC11ONS REQUIRED PRIOR TO PULLING CONDUCTORS INTO NEW CONDUITS. I. CONTRACTOR SHALL PROVIDE ALL EQUIPMENT AND MATERIAL NECESSARY FOR A COMPLETE AND OPERATIONAL INSTALLATION. J. CONTRACTOR SHALL NOT DISRUPT SERVICE TO ELECTRICAL APPURTENANCES TO REMAIN. K. CONTRACTOR SHALL CONNECT ALL NEW FIRE ALARM DEVICES, AS INDICATED ON DRAWINGS, TO EXISTING SYSTEM. CONTRACTOR SHALL PROVIDE NEW EXPANDABLE MODULES, CARDS, ETC. AS REQUIRED TO EXISTING SYSTEM, IN ORDER TO ACCOMODATE NEW DEVICES. �• ALL PANELBOARDS SERVING THE AREA OF WORK SHALL BE BONDED TOGETHER IN COMPLIANCE WITH THE NEC. M. CONTRACTOR SHALL PROVIDE EQUIPOTENTIAL TEST FOR ALL ELECTRICAL DEVICES AND EQUIPMENT WITHIN THE AREA OF WORK. N. ALL RECEPTACLES AND SWITCH PLATES SHALL HAVE ENGRAVED COVER PLATES TO INDICATE THE PANEL BOARD AND CIRCUIT NUMBERS POWERING THE DEVICE. 0. ALL EMERGENCY RECEPTACLES, LIGHT SWITCHES, AND RESPECTIVE COVER PLATES SHALL BE RED. P. THE ELECTRICAL CONTRACTOR SHALL VERIFY THAT THE AIC RATING OF ALL EXISTING CIRCUIT BREAKERS IN PANELS AFFECTED BY THIS PROJECT ARE ABOVE THE FAULT CURRENT VALUES PROVIDED IN THE SHORT CIRCUIT CALCULATIONS. IF THE AIC RATINGS ARE BELOW THE FAULT CURRENT VALUES, THE ELECTRICAL CONTRACTOR SHALL REPLACE ALL BREAKERS WITH NEW BREAKERS WITH AIC RATINGS ABOVE THE FAULT CURRENT VALUES. Q. CONTRACTOR SHALL UPDATE ALL ELECTRICAL PANEL SCHEDULES AFFECTED BY THIS PROJECT. HAND WRITTEN SCHEDULES ARE NOT ACCEPTED. SCHEDULES SHALL BE TYPED OR COMPUTER GENERATED. R. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONNECT ANY NEW FIRE /SMOKE DAMPERS TO THE EXISTING FIRE ALARM SYSTEM. CONTRACTOR SHALL PROVIDE ALL EQUIPMENT AND MATERIAL NECESSARY FOR A COMPLETE AND OPERATIONAL INSTALLATION. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION OF FIRE /SMOKE DAMPERS. LIGHTING FIXTURE SCHEDULE TYPE MANUFACTURER AND CATALOG NO. LAMPS VOLT. MOUNTING DESCRIPTION NOTES o DAY -BRITS (2) F32T8 120 RECESSED 2' X 4' FLUORESCENT A 2STG232PMW- UNV- 1 /2 -EB- PAF -GLR1 CAPRI (2) 18W DTT 120 RECESSED LENSED FLUORESCENT SHOWER LIGHT B CM6- F218U -H65F INFINITY (2) 18W DTT 120 RECESSED FLUORESCENT DOWN LIGHT c PH60- 218Q- EB- CS-MWT INFINITY (2) 18W OTT 120 RECESSED FLUORESCENT DOWN LIGHT WITH D PH60- 218Q- EB- CS -MWT -DIM DIMMING BALLAST SOLAVANTI (2) 11W GX23 120 WALL 24" FLUORESCENT WALL MOUNTED E 147455 VISTA (4)T5HO 120 WALL READING LIGHT CONTROLLED VIA BEDSIDE F AG9348- MCS /2L -T5H0- CONTROL, WITH ROCKER SWITCH AT LEFT O 120V -MW SIDE FOR EXAM LIGHTING. ARCHITECTURAL (4) F40BX 120 RECESSED MULTI FUNCTION PATIENT LIGHT GI LIGHTING SYSTEMS EXAM /AMBIENT (D@ MT1E- 440- 1- E -1 -SW ARCHITECTURAL (1) PL7 120 RECESSED MULTI FUNCTION PATIENT LIGHT GZ LIGHTING SYSTEMS NURSE/READING Q MT1F- 1007- 1- E -1 -SW DAYBRITE (2) Fl 4T5 120 RECESSED 2' X 2' FLUORESCENT H 2STG214PMW- UNV- 1 /2 -EB- PAF-GLR1 VISTA (1) 13WDTT 120 RECESSED NIGHT LIGHT J F13Q- ST- L- C -EB -MW -120 LIGHTING FIXTURE SCHEDULE KEYED NOTES: O FIXTURE SHALL BE PROVIDED WITH LOW VOLTAGE RELAY COMPATIBLE WITH BED SIDE CONTROLS. FIXTURE SHALL BE CONTROLLED AS FOLLOWS. AMBIENT LIGHT FUNCTION - SWITCHED AT PATIENT BEDSIDE CONTROL AND ROOM ENTRANCE EXAM LIGHT FUNCTION - SWITCHED AT HEADWALL NURSE/CHART UGHT FUNCTION - SWITCHED AT ROOM ENTRANCE READING UGHT FUNCTION - SWITCHED AT PATIENT BEDSIDE CONTROL O EXAM LIGHT BALLAST SHALL BE CONNECTED TO THE CRITICAL BRANCH AND THE AMBIENT LIGHT BALLAST TO THE NORMAL BRANCH. WIRING COMPARTMENTS SHALL HAVE SEPARATED CRITICAL AND NORMAL WIRING AND SHALL BE LABELLED AS SUCH FROM THE MANUFACTURER. 30 READING UGHT TO BE CONTROLLED VIA BEDSIDE CONTROLS, COORDINATE WITH NURSE CALL VENDOR. LIGHTING FIXTURE SCHEDULE GENERAL NOTES: A. REFER TO SPECIFICATIONS FOR FURTHER REQUIREMENTS. CITY OF SOUTH MIAMI BUILDING DEPT. ELECTRICAL SECTION APPROVED BY: "�"� DATE' 1 ( O J J • D oG Q oC Q Z W OC � U W U� OC 2! 19021 Q .- �eN E E �a8 8 8 N co a o o 12 04 Q 72 7 c 0Lr ��C 2 2 C r � M . ca I O m i ME 4) O U. .E CIS ca a� Q O _co co O C TO E m m i 4) d ■E c ♦^ O co m .ca 4) n O 4 co L CL O C to 5: (0 0 Comm. No: 08061 Date: 07/07/08 Drawn: Revised: Y • � F� e ® 2008 HARVARD JOLLY„ IJ11,r • , E0.00 Comm. No: 08061 Date: 07/07/08 Drawn: Revised: Y • � F� e ® 2008 HARVARD JOLLY„ IJ11,r • , E0.00 Y • � F� e ® 2008 HARVARD JOLLY„ IJ11,r • , E0.00