Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
08-957-019
SPECIFICATIONS I GENERAL CONDITIONS: A. THE SCOPE OF THE WORK SHALL INCLUDE THE FURNISHING AND INSTALLATION OF THE NECESSARY MATERIAL AND LABOR TO ACCOMPLISH THE WORK INDICATED BY THE DRAWINGS AND HEREIN SPECIFIED. ALL WORK BY THIS CONTRACTOR SHALL CONFORM TO ALL APPLICABLE FEDERAL, STATE AND LOCAL BUILDING CODES. B. CONTRACTOR SHALL BE RESPONSIBLE FOR REVIEWING THE EXISTING CONDITIONS AT THE JOB SITE BEFORE SUBMITTING PROPOSALS. SUBMISSION OF PROPOSALS SHALL BE TAKEN AS EVIDENCE THAT SUCH INSPECTION HAS TAKEN PLACE. THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE COMPLETE SET OF CONSTRUCTION DOCUMENTS, AND THE LACK OF SPECIFIC INFORMATION ON THE DRAWINGS SHALL NOT RELIEVE THE CONTRACTOR OF ANY RESPONSIBILITY. C. MATERIALS AND EQUIPMENT FURNISHED UNDER THIS CONTRACT SHALL BE NEW AND SHALL BEAR THE UL. LABEL WHERE APPLICABLE, UNLESS NOTED OTHERWISE. ALL WORK SHALL BE GUARANTEED AGAINST DEFECTIVE MATERIALS AND WORKMANSHIP FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR AFTER COMPLETION AND ACCEPTANCE BY THE OWNER. D. MATERIALS AND WORKMANSHIP SHALL COMPLY WITH THE CONTRACT DOCUMENTS AND APPLICABLE CODES AND STANDARDS. IN CASE OF DIFFERENCE BETWEEN APPLICABLE CODES AND STANDARDS AND THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL PROMPTLY NOTIFY THE ARCHITECT /ENGINEER AND THE OWNER IN WRITING OF SUCH DIFFERENCE. SHOULD THE CONTRACTOR PERFORM ANY WORK THAT DOES NOT COMPLY WITH THE REQUIREMENTS OF APPLICABLE CODES AND STANDARDS, HE SHALL BEAR ALL COSTS ARISING IN CORRECTING SUCH DEFECTS. APPLICABLE CODES AND STANDARDS SHALL INCLUDE ALL ORDINANCES, UTILITY COMPANY REGULATIONS, AND APPLICABLE REQUIREMENTS OF NATIONALLY ACCEPTED CODES AND STANDARDS. SHOULD THE CONTRACTOR SUPPLY EQUIPMENT DIFFERING FROM THE SPECIFIED ITEMS IN THE CONTRACT DOCUMENTS WITHOUT NOTIFICATION TO THE ENGINEER, HE SHALL BEAR ALL COSTS TO UPGRADE DEFICIENCIES ARISING FROM SUCH. E. WHERE ONLY ONE MANUFACTURER'S NAME IS LISTED IN THE EQUIPMENT SPECIFICATION, OTHER MANUFACTURERS OF SIMILAR CHARACTERISTICS AND OF EQUAL OR BETTER PERFORMANCE CAPACITIES MAY BE CONSIDERED FOR "OR EQUAL" APPROVAL BY THE ENGINEER. WHERE MORE THAN ONE MANUFACTURER IS LISTED IN THE NOTES AND EQUIPMENT SPECIFICATIONS, ONLY THOSE NAMED MANUFACTURERS WILL BE CONSIDERED FOR APPROVAL. F. SHOULD A SUBSTITUTION BE ACCEPTED, AND SHOULD THE SUBSTITUTE MATERIAL PROVE DEFECTIVE, OR OTHERWISE UNSATISFACTORY FOR THE SERVICE INTENDED WITHIN THE GUARANTEE PERIOD, THIS MATERIAL OR EQUIPMENT SHALL BE REPLACED WITH THE MATERIAL OR EQUIPMENT SPECIFIED AT NO COST TO THE OWNER. G. PROVIDE SNAP —ON OR ADHESIVES LABELS INDICATING SERVICES, EQUIPMENT AND DIRECTION OF FLUID FLOW. MECHANICAL DEMOLITION A. UNLESS NOTED OTHERWISE, THE MECHANICAL DEMOLITION SHALL BE CARRIED OUT TO THE EXTENT THAT THE FLOORS ARE RETURNED TO THE ORIGINAL BASE BUILDING CONDITIONS. CONTRACTOR SHALL VERIFY ALL EXISTING FIELD CONDITIONS IN ORDER TO ACCURATELY DETERMINE THE EXTENT OF THE WORK UNDER THIS SECTION. B. PIPING SHALL BE REMOVED BACK TO RISER STACK CONNECTIONS AND CAPPED, UNLESS NOTED OTHERWISE. III PRODUCTS, EQUIPMENT AND EXECUTION: A. SANITARY DRAIN LINES (SOIL, WASTE AND VENT) SHALL BE AMERICAN MANUFACTURED SERVICE WEIGHT CAST IRON OR DWV COPPER PIPE. JOINTS SHALL BE FABRICATED BY THE USE OF COMPRESSION JOINTS SIMILAR TO TYLER PIPE AND FOUNDRY'S "TY— SEAL" FOR CAST IRON PIPE OR 95/5 SOLDER FOR DWV COPPER PIPE. NO —HUB CAST IRON PIPE ASSEMBLED WITH STAINLESS STEEL /NEOPRENE HUBLESS COUPLINGS SHALL BE LIMITED TO ABOVE GROUND INSTALLATIONS. B. DOMESTIC WATER PIPING INSTALLED ABOVE GROUND SHALL BE AMERICAN MANUFACTURED TYPE "L" HARD DRAWN COPPER ASSEMBLED WITH 95/5 SOLDER AND WROUGHT COPPER JOINTFITTINGS. C. RELIEF AND DRAIN PIPING SHALL BE AMERICAN MANUFACTURED TYPE "M" COPPER WITH 95/5 SOLDER JOINT FITTINGS OR SCHEDULE 40 BLACK STEEL PIPES WITH SCREWED FITTINGS. D. MEDICAL GAS PIPING SHALL BE INSTALLED IN STRICT ACCORDANCE WITH 2002 E. NFPA -99 AND HOSPITAL LICENSING CODE REQUIREMENTS, GCA P -2.1 RECOMMENDATIONS FOR MEDICAL — SURGICAL VACUUM SYSTEMS IN HEALTH CARE FACILITIES. F. 1. PIPING SHALL BE AMERICAN MANUFACTURED SEAMLESS TYPE 'K' HARD —DRAWN COPPER TUBING CLEANED AND SEALED FOR MEDICAL GAS USE. FITTINGS SHALL BE WROUGHT, BRASS OR BRONZE, MADE ONLY FOR BRAZED CONNECTIONS. ALL JOINTS IN THE PIPING, EXCEPT AT VALVES AND EQUIPMENT REQUIRING SCREW CONNECTIONS, SHALL BE ASSEMBLED WITH A SILVER G. BRAZING ALLOY. SCREWED JOINTS SHALL BE MADE —UP WITH GLYCERIN. 2. MEDICAL GAS WALL OUTLETS SHALL MATCH EXISTING MANUFACTURER, MODEL NUMBER AND FINISH OR MAY BE BEACON MEDICAL PRODUCTS TO MATCH EXISTING. 3. PROVIDE NECESSARY PIPING, FITTINGS, VALVES, ALARMS, SENSORS, WIRING, OUTLETS, ETC. AND LABOR FOR COMPLETE OPERATING SYSTEMS. 4. COLOR —CODED ADHESIVE PIPE MARKERS SHALL BE INSTALLED AT NO MORE THAN 20 FEET APART, OR ONE IN EACH ROOM, OR EACH FLOOR OF THE BUILDING. LABELS SHALL INCLUDE GAS CONTENTS, OPERATING PRESSURE AND THE DIRECTION OF FLOW ON ALL MEDICAL GASES, COMPRESSED AIR AND VACUUM PIPING. N 5. THE MEDICAL VACUUM PIPING SHALL ORIGINATE FROM THE EXISTING VACUUM PIPING SYSTEMS LOCATED ABOVE THE CORRIDOR CEILING. 6. THE OXYGEN PIPING SHALL ORIGINATE FROM THE EXISTING OXYGEN DISTRIBUTION LINE ABOVE THE CORRIDOR CEILING. 7. THE MANUFACTURER OF MEDICAL GAS EQUIPMENT SHALL TEST ALL MEDICAL GAS PIPING SYSTEMS AFTER INSTALLATION TO INSURE THAT NO CROSSED LINES EXIST AND THAT THE PROPER SERVICE IS BROUGHT TO EACH OUTLET. THE TEST SHAD_ BE PERFORMED IN ACCORDANCE WITH NFPA 99 GAS SYSTEM PERFORMANCE CRITERIA AND TESTING. FURNISH THE OWNER, THROUGH THE ARCHITECT, A WRITTEN CERTIFICATION, SIGNED BY AN OFFICER OF THE COMPANY, THAT THE SYSTEM HAS BEEN CHECKED AND IS CONSTRUCTED AND TESTED IN ACCORDANCE WITH NFPA 99 AND IS SAFE FOR PATIENT USE. MANUFACTURER MUST SUBMIT A LETTER SIGNED BY AN OFFICER OF THE COMPANY TO THE ARCHITECT 10 DAYS PRIOR TO BID OPENING THAT THIS SERVICE WILL BE PERFORMED. 8. VALVES NOT IN BOXES SHALL BE BEACON BRONZE —BODY, DOUBLE —SEAL, FULL—FLOW UNION BALL TYPE, WITH TEFLON SEATS AND SEALS, DESIGNED FOR A WORKING PRESSURE OF 27" Hg VACUUM TO 400 PSI WITH CHROME — PLATED BRASS BALLS WHICH SEAL IN BOTH DIRECTIONS. EACH VALVE SHALL BE SO DESIGNED THAT ONLY A QUARTER TURN OF THE LEVER TYPE HANDLE IS NECESSARY BETWEEN THE OPEN AND CLOSED POSITIONS. VALVE DESIGN SHALL ELIMINATE THE NEED FOR UNIONS BY PERMITTING REMOVAL OR SWING —AWAY OF THE CENTER VALVE SECTION OUT —OF —LINE. VALVES SHALL CONFORM TO NFPA STANDARDS. VALVES SHALL BE SUPPLIED PROPERLY WASHED FOR OXYGEN SERVICE. GAS SERVICE LABELS SHALL BE PROVIDED FOR EACH SERVICE AS REQUIRED. 9. PROVIDE GAUGES ON SYSTEMS AS REQUIRED BY NFPA 99, CURRENT EDITION, AND WHERE INDICATED ON THE DRAWINGS. 10. GAUGES FOR PIPELINE INSTALLATION SHALL BE EQUAL TO OHMEDA MAIN LINE GAUGES AS FOLLOWS: SERVICE CALIBRATION STOCK NO. a. OXYGEN, N20, AIR 0 -100 PSI 841- 0014 -300 b. VACUUM 0 -30" Hg. 395 - 7558 -300 c. NITROGEN 0 -400 PSI 841- 0007 -300 11. WALL SERVICE OUTLETS SHALL BE INSTALLED WHERE INDICATED ON THE DRAWINGS AND SHOWN ON ARCHITECTURAL ELEVATIONS. 12. OUTLETS TO MATCH EXISTING. 13. BEFORE ERECTION, ALL PIPE, TUBING, VALVES AND FITTINGS (EXCEPT THOSE SUPPLIED EXPRESSLY CLEANED FOR OXYGEN SERVICES BY MANUFACTURER) SHALL BE THOROUGHLY CLEANSED OF ALL GREASE, OIL OR OTHER READILY OXIDIZABLE MATERIALS BY WASHING IN A HOT SOLUTION OF SODIUM CARBONATE OR TRISODIUM PHOSPHATE MIXED IN EQUAL PROPORTIONS OF ONE POUND TO THREE GALLONS OF WATER. SCRUBBING AND CONTINUOUS AGITATION OF THE PARTS SHALL BE EMPLOYED WHERE NECESSARY TO REMOVE ALL DEPOSITS AND INSURE COMPLETE CLEANSING. AFTER WASHING, ALL MATERIALS SHALL BE RINSED THOROUGHLY IN CLEAN, HOT WATER. AFTER CLEANSING, GREAT CARE MUST BE EXERCISED IN THE STORAGE AND HANDLING OF ALL MATERIALS AND IN THE CONDITION OF TOOLS USED IN CUTTING AND REAMING TO PREVENT OIL OR GREASE BEING INTRODUCED INTO THE TUBING. WHERE SUCH CONTAMINATION IS KNOWN TO HAVE OCCURRED, THE MATERIALS AFFECTED MUST BE REWASHED AND THEN RINSED. 14. AFTER INSTALLATION OF THE PIPING, BUT BEFORE INSTALLATION OF THE STATION OUTLETS AND OTHER MEDICAL GAS SYSTEM COMPONENTS (e.g., PRESSURE — ACTUATING SWITCHES FOR ALARMS, MANIFOLDS, PRESSURE GAUGES OR PRESSURE RELIEF VALVES), THE LINE SHALL BE BLOWN CLEAR BY MEANS OF OIL —FREE, DRY AIR OR NITROGEN. THE SYSTEM SHALL BE TESTED IN ACCORDANCE WITH NFPA 99 4 -5.1.3 "MEDICAL GAS SYSTEM TEST". 15. ALL PIPING SHALL BE SUPPORTED WITH COPPER —CLAD HANGERS WITH POLYSTYRENE OR NEOPRENE INSERTS OR PADS AT APPROPRIATE INTERVALS AND NOT SUPPORTED BY OTHER PIPING. FITTINGS AND PIPING CONNECTED WITH PLUMBING FIXTURES SHALL BE BRASS AND, WHEREVER EXPOSED, SHALL BE POLISHED CHROME — PLATED. FURNISH AND INSTALL ALL REQUIRED WATER, WASTE, SOIL, AND VENT CONNECTIONS TO ALL PLUMBING FIXTURES AND EQUIPMENT, TOGETHER WITH ALL FITTINGS, SUPPORTS, FASTENING DEVICES, COCKS, VALVES, TRAPS, ETC., LEAVING ALL IN COMPLETE WORKING ORDER. PLUMBING FIXTURES SHALL BE PROVIDED AS SCHEDULED ON THE DRAWINGS. PLUMBING FIXTURES SHALL BE NEW, EXCEPT WHERE NOTED, AND SHALL BE APPROVED BY THE APPLICABLE WATER CONSERVATION AUTHORITY. THE PLUMBING CONTRACTOR SHALL PROVIDE NECESSARY CHROME PLATED P— TRAPS, SUPPLIES WITH STOPS, RISERS, INLET DRAINS, ETC. PIPE, EQUIPMENT, ETC., SHALL BE PROPERLY SUPPORTED FROM STRUCTURE WITH THE USE OF APPROVED TYPE CLEVIS, TRAPEZE HANGERS OR FLOOR STANDS WITH SPACING AS FOLLOWS: 1. STEEL PIPE OR COPPER TUBING — 1 -1/2" OR LESS, 6 FOOT INTERVALS. 2. FITTINGS — WITHIN 2' -0" OF EACH CHANGE OF DIRECTION. I. INSULATION SHALL BE PROTECTED AT HANGERS BY A SECTION OF CALCIUM SILICATE PIPE INSULATION AND A 12" LONG HALF —ROUND SHEET METAL SHIELD ON THE OUTSIDE OF THE INSULATION. EXTEND PIPING INSULATION FULL THICKNESS WITHOUT INTERRUPTION THROUGH WALLS, FLOORS AND SIMILAR PENETRATIONS PLUMBING FIXTURE SCHEDULE DESIG DRAWING TITLE SCALE AMERICAN STANDARD "AFWALL FLOWISE" 3355.128 WALL HUNG VITREOUS CHINA WATER CLOSET, ELONGATED BOWL WITH 1 -1/2' TOP SPUD; J R SMITH FLOOR MOUNTED CARRIER; WC -1 SLOAN CROWN 111 -1.2 FLUSH VALVE WITH CONTROL HANDLE ON WIDE SIDE OF FIXTURE, SCREWDRIVER STOP & VACUUM BREAKER; CHURCH # 950OSSC OPEN FRONT SEAT, P2.51 COVER WITH SELF SUSTAINING HINGES; ADA MOUNTING HEIGHT REQUIREMENTS. L -1 KOHLER 'PENNINGTON' K- 2196 -8 COUNTERTOP VITREOUS CHINA LAVATORY, AMERICAN STANDARD 4801.972 LAVATORY FAUCET WITH LEVER HANDLES; McGUIRE 155WC STRAINER PARTIAL SEVENTH FLOOR PLAN — PLUMBING AND OFFSET TAILPIECE; McGUIRE # 8872 P -TRAP; McGUIRE # H171LK SUPPUES W/LOOSE KEY STOPS; PRESSURE GAUGE WITH GAUGE COCK AMERICAN STANDARD "MURRO" 0954.000 WALL HUNG VITREOUS CHINA LAVATORY, AMERICAN STANDARD 4801.972 LAVATORY FAUCET WITH LEVER HANDLES: McGUIRE 155WC L -2 STRAINER AND OFFSET TAILPIECE; McGUIRE # 8872 P -TRAP; McGUIRE # H171LK SUPPLIES W/LOOSE KEY STOPS; JAY R SMITH FLOOR MOUNTED CARRIER; ADA MOUNTING HEIGHT THERMOMETER WITH SHUT -OFF COCK REQUIREMENTS. SH -1 J R SMITH # 2005 -A CAST IRON FLOOR DRAIN WITH SATIN NICKEL STRAINER; AMERICAN STANDARD AMARILIS T341.000 PRESSURE BALANCING SHOWER VALVE WITH INLET CHECK HOSE BIBB (H.B.) OR WALL HYDRANT (WH) STOPS; AMERICAN STANDARD AMARILIS T342.000 SHOWER HEAD. EXISTING PIPING TO REMAIN 1/2" IV RECORDS FOR OWNER: A. CONTRACTOR SHALL KEEP A CLEAN SET OF DRAWINGS ON THE JOB, NOTING DAILY ALL CHANGES MADE IN THESE DRAWINGS IN CONNECTION WITH THE FINAL INSTALLATION INCLUDING EXACT DIMENSIONED LOCA11ONS OF ALL NEW AND UNCOVERED EXISTING UTILITIES AND SHALL, WITH HIS REQUEST FOR FINAL PAYMENT, TURN OVER A CLEAN, NEATLY MARKED SET OF REPRODUCIBLE' DRAWINGS OR UPDATED CAD FILES ON CD SHOWING "AS INSTALLED" WORK TO THE ARCHITECT FOR SUBSEQUENT REVIEW AND TRANSMITTAL TO THE OWNER. CONTRACTOR SHALL NOTE ALL CONSTRUCTION CHANGES, DATE EACH SHEET AND LABEL "AS— BUILTS" IN THE REVISION BLOCK ON THE DRAWINGS. CONTRACTOR SHALL ALSO FURNISH ONE (1) SET OF BLUELINE PRINTS FROM THE "AS— BUILTS" DRAWINGS OR CD CONTAINING UP DATED CAD FILES SHOWING LATEST CHANGE. B. IN ADDITION TO THE ABOVE, CONTRACTOR SHALL ACCUMULATE DURING THE JOB'S PROGRESS, THE FOLLOWING DATA, IN TRIPLICATE, PREPARED IN A NEAT BROCHURE OR PACKET FOLDER AND TURNED OVER TO THE ARCHITECT FOR REVIEW AND SUBSEQUENT DELIVERY TO THE OWNER. 1. ALL WARRANTIES AND GUARANTEES AND MANUFACTURER'S DIRECTIONS ON EQUIPMENT AND MATERIAL COVERED BY THE CONTRACT INCLUDING THE NAMES, ADDRESSES AND TELEPHONE NUMBERS OF THE MANUFACTURER'S REPRESENTATIVE. 2. APPROVED FIXTURE BROCHURES, WIRING DIAGRAMS AND CONTROL DIAGRAMS (ORIGINAL DATA, NO COPIES). 3. COPIES OF APPROVED SHOP DRAWINGS. 4. OPERATING INSTRUCTIONS FOR HEATING AND COOLING AND OTHER MECHANICAL SYSTEM. OPERATING INSTRUCTIONS SHALL ALSO INCLUDE RECOMMENDED MAINTENANCE PROCEDURES. 5. TEST AND BALANCE REPORTS REQUIRED BY THESE SPECIFICATIONS. 6. ANY AND ALL OTHER DATA AND /OR DRAWINGS REQUIRED DURING CONSTRUCTION. 7. REPAIR PARTS LISTS OF ALL MAJOR ITEMS & EQUIPMENT INCLUDING NAME, ADDRESS AND TELEPHONE NUMBERS OF LOCAL SUPPLIER OR AGENT. C. ALL OF THE ABOVE DATA SHALL BE SUBMITTED TO THE ENGINEER FOR HIS REVIEW AT SUCH 11ME AS THE CONTRACTOR SUBMITS HIS LAST ESTIMATE PRIOR TO HIS FINAL PAYMENT, BUT IN NO CASE, LESS THAN TWO WEEKS BEFORE FINAL INSPECTION. GENERAL NOTES A. LOCATION OF EXISTING SYSTEMS AND APPURTENANCES HAVE BEEN TAKEN FROM "AS- BUILT" DOCUMENTS. THE CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION OF ALL EXISTING PLUMBING EQUIPMENT AND APPURTENANCES THAT WILL REQUIRE SOME TYPE OF MODIFICATION DUE TO THE RENOVATION AND /OR NEW CONSTRUCTION OF THIS CONTRACT PRIOR TO PRICING AND COMMENCEMENT OF WORK. B. REMOVE EXISTING PIPING, WHERE NOTED OR REQUIRED, TO BEYOND FINISHED SURFACES AND CAP AS REQUIRED OR INDICATED ON PLANS. VERIFY EXACT LOCATION OF EXISTING PLUMBING AT SITE C. ANY EXISTING PLUMBING RISER LOCATED IN WALLS /CHASES INDICATED TO BE DEMOLISHED MUST BE RELOCATED TO A CONVENIENT LOCATION. D. REFER TO THE ARCHITECTURAL PHASING PLAN FOR THE PHASING OF CONSTRUCTION. WORK SHALL BE SCHEDULED AND PERFORMED IN SEQUENCE WITH THE ARCHITECTURAL PHASING PLAN. E. PROVISIONS SHALL BE MADE BY THE CONTRACTOR TO PREVENT DISRUPTING ADJACENT AREAS OF THE PHASE IN WHICH WORK IS BEING PERFORMED. F. PROVIDE ADDITIONAL VALVES, TAPS, TEMPORARY PIPING, ETC. AS NECESSARY TO PROVIDE UNINTERRUPTED SERVICE TO AREAS OUTSIDE OF THE PHASE IN WHICH WORK IS BEING PERFORMED. G. ALL WORK SHALL BE PERFORMED IN STRICT COORDINATION WITH FACILITY SCHEDULES AND OCCUPANCIES. CONTRACTOR SHALL COORDINATE WITH FACILITY REPRESENTATIVE. H. COORDINATE WITH OTHER TRADES THE LOCATION AND ROUTING OF ALL PLUMBING, MEDICAL GAS & FIRE PROTECTION SYSTEMS. I. ALL PIPING SHALL RUN IN WALLS /CHASES /ABOVE CEILING. WERE EXPOSED PIPING HAS TO BE INSTALLED PROVIDE CHROME PLATTED PIPING. OBTAIN ARCHITECT'S APPROVAL PRIOR TO INSTALLATION OF ANY EXPOSED PIPING. J. VERIFY ALL MOUNTING HEIGHTS WITH ARCHITECTURAL DRAWINGS. K. VALVES NOT LOCATED IN ZONE BOXES SHOULD BE LOCKING TYPE. MEDICAL GAS SYSTEM TO BE 2002 NFPA 99 COMPLIANT. L. COORDINATE WITH OWNER AND PERSONNEL SHUT -DOWN OF MEDICAL GASES AND PLUMBING SYSTEMS. M. RETAIN A QUALIFIED THIRD PARTY VERIFIER ACCEPTABLE TO THE ARCHITECT AND OWNER TO PERFORM AND ATTEST TO FINAL VERIFICATION OF THE SYSTEMS. PROPOSED VERIFIER SHALL PROVIDE A REFERENCE UST, WHICH INCLUDES AT LEAST THREE REFERENCES ON PROJECTS OF SIMILAR SIZE AND COMPLEXITY. MEDICAL GAS LEGEND MGO = MEDICAL GAS WALL OUTLETS. MEX = EXISTING MEDICAL GAS OUTLETS OX = OXYGEN. MA = MEDICAL COMPRESSED AIR. MV = MEDICAL VACUUM. S = SLIDE (ONE PER MV). N - NITROGEN. N20 = NITROUS OXIDE WAG = WASTE ANESTHETIC GAS. ZVB = ZONE VALVE BOX AAP = AREA ALRM PANEL MGO- O�X,M�A,MV,S,N,N2�0,WAG OXYGEN —' I I ' —WASTE ANESTHETIC GAS MEDICAL COMPRESSED AIR NITROUS OXIDE VACUUM NITROGEN SLIDE EXAMPLE: 2122011 111 1 WAG 2 OX N20 1 MA NITROGEN (N) 2 MV 2 SLIDES (S) MEDICAL GAS NOTES: A. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT MEDICAL GAS OUTLET LOCATIONS & MOUNTING HEEMRIPTION B. NOT ALL GASES MAY BE USED. THE GAS ORDER SHOWN IN THE EXAMPLE WILL BE TYPICAL FOR ALL OUTLETS. C. COORDINATE WITH OWNER AND PERSONNEL MEDICAL GAS SHUT DOWN. PLUMBING SHEET LIST DWG No. DRAWING TITLE SCALE PO.00 GENERAL INFORMATION — PLUMBING NTS P2.51 PARTIAL FIFTH FLOOR PLAN — PLUMBING 1/4" = 1' -0" P2.71 PARTIAL SEVENTH FLOOR PLAN — PLUMBING 1 /4" = 1' -0" a 2121 Ponc:�6 cue Leon ^Blvd., Suite,350, PLUMBING SYMBOLS ALL SYMBOLS SHOWN MAY NOT APPEAR IN ALL DRAWINGS. SYMBOLS ARE SHOWN SCHEMATICALLY AND MAY NOT BE TO SCALE. SYMBOL DESCRIPTION SYMBOL DESCRIPTION - DOMESTIC COLD WATER COLD GAUGE COCK — -- — DOMESTIC HOT WATER (1207 UNLESS OTHERWISE NOTED) 2" PRESSURE GAUGE WITH GAUGE COCK — --- — DOMESTIC HOT WATER RETURN (1207 UNLESS OTHERWISE NOTED) n THERMOMETER WITH SHUT -OFF COCK SH COLD OR HOT REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER (R.P.P.B.Pj �--� HOSE BIBB (H.B.) OR WALL HYDRANT (WH) — EX — EXISTING PIPING TO REMAIN 1/2" RECESSED BOX WALL HYDRANT x -X—X- x EXISTING PIPING TO BE REMOVED 4" PIPING TO BE ELECTRICALLY HEAT TRACED —® YARD HYDRANT # # # SS SANITARY SEWER PIPING (SOIL OR WASTE) -I- T SLEEVE THRU WALL - - - -- SANITARY VENT PIPING EXPANSION LOOP —SSD SUB -SOIL DRAIN PIPING, FOOTING DRAIN PIPING ANCHOR AW ACID WASTE PIPING -- AV -- ACID VENT PIPING —® GCO FLOOR CLEANOUT OR GRADE CLEANOUT I.W. INDIRECT WASTE WC WALL CLEANOUT —SED— SEWAGE EJECTOR DISCHARGE PIPING (PUMPED SANITARY) CO CO _2` CLEANOUT PLUG — CD — CONDENSATE DRAIN PIPING OS & Y VALVE SUPERVISED (HORIZ. POSITION /VERT. POSITION) —DPD— DRIP PAN DRAIN PIPING C INDICATING BUTTERFLY VALVE SUPERVISED (HORIZ. POSITION /VERT. POSITION) Q5 CONNECT NEW TO EXISTING SD — STORM DRAIN PIPING (SD) FCA SPRINKLER SYSTEM FLOOR CONTROL ASSEMBLY — OD — STORM OVERFLOW DRAIN PIPING (OD) DOUBLE CHECK VALVE ASSEMBLY (D.C.V.A.) WITH OS & Y VALVES SUPERVISED —SPD SUMP PUMP DISCHARGE PIPING (PUMPED STORM WATER) FLOW SWITCH — G — NATURAL GAS PIPING o--�� FIRE HOSE VALVE — A COMPRESSED AIR PIPING rrrTrm FIRE HOSE CABINET (SURFACE MOUNTED) — V — VACUUM PIPING —ATV— ATMOSPHERIC VENT PIPING (STEAM OR HOT VAPOR) =1331= FIRE HOSE CABINET (RECESSED) — F — FIRE PROTECTION (STANDPIPE, SPRINKLER, SERVICE) 2 -WAY SIAMESE FIRE DEPARTMENT CONNECTION —DFS— DRY FIRE STANDPIPE PIPING � DIRECTION OF SLOPE — SP — SPRINKLER PIPING (SPRK.) �— DIRECTION OF FLOW —SDR— SPRINKLER DRAIN RISER PIPING CAP OUTLET OR PLUGGED OUTLET —DSP— DRY SPRINKLER PIPING —PASP— PRE - ACTION SPRINKLER PIPING -- UNION -_- -04- GATE VALVE — OX — MEDICAL OXYGEN PIPING F� BUTTERFLY VALVE — MA — MEDICAL AIR PIPING —� BALL VALVE — MV — MEDICAL VACUUM PIPING GLOBE VALVE — EV — MEDICAL EVACUATION PIPING TEMPERATURE AND PRESSURE RELIEF VALVE — N — MEDICAL NITROGEN PIPING GAS COCK / PLUG VALVE —N20— MEDICAL NITROUS OXIDE PIPING SOLENOID VALVE MASTER ALARM SENSOR PRESSURE REGULATION VALVE (PRV) � LOCAL ALARM SENSOR IN -LINE CIRCULATING uu MEDICAL GAS PIPING DROPS IN WALL FULL SIZE AIR CHAMBER PLUMBING ABBREVIATIONS AFF ABOVE FINISH FLOOR INV INVERT AFG ABOVE FINISH GRADE I.E. INVERT ELEVATION A/C ABOVE HUNG CEILING LT LAUNDRY TRAY AP ACCESS PANEL OR DOOR L. -LAV. LAVATORY AC AIR CHAMBER MH MANHOLE AD AREA DRAIN MS MOP SINK BASIN BT BATHTUB PD PLANTER DRAIN BFF BELOW FINISH FLOOR PRV PRESSURE REDUCING VALVE B/F BELOW FLOOR RD ROOF DRAIN B/G BELOW GRADE SS SERVICE SINK OR SLOP SINK CSS CLINICAL SERVICE SINK SH SHOWER DS DOWNSPOUT SD SHOWER DRAIN DF DRINKING FOUNTAIN S. -SK. SINK EWC ELECTRIC WATER COOLER UR URINAL FD FLOOR DRAIN VTR VENT THROUGH ROOF FS FLOOR SINK WS WASH SINK FRS FLUSH RIM SINK WH WALL HYDRANT GC GENERAL CONTRACTOR WC WATER CLOSET GCO GRADE CLEANOUT YCO YARD CLEANOUT AQUASTAT --�}— CHECK VALVE — CHECK VALVE WITH AUTOMATIC BALL DRIP BACK WATER VALVE Cam* }I VALVE IN VERTICAL GAS PRESSURE REGULATOR VALVE BALANCING VALVE �~ STRAINER WITH BLOW -OFF VALVE STRAINER HYDRAULIC SHOCK ARRESTOR (SA) �— VACCUUM BREAKER (VB) En FLOOR DRAIN W/ P -TRAP �Do HUB DRAIN (ALL TYPES) (SPECIFY) ® ® FLOOR DRAIN (ALL TYPES) (SPECIFY) �— DOUBLE CLEANOUT, 2 -WAY CLEANOUT (GRADE) (D.C.O.) PLUMBING FIXTURE CONNECTION SCHEDULE MARK TYPE OF FIXTURE WASTE VENT TRAP WATER REMARKS COLD HOT L LAVATORY 2" 2" 1 1/4- 1/2" 1/210 .O f+ SH SHOWER 2" 2" 2" 1/2" 1/2" WC WATER CLOSET 4" 1 2" 1 - 1" - v i Q W C3 CD to Go a. r , o V J U- Ww J 0 o! w z U Q o C3 (c cn L6 C?pr c9ti" M EP N v N _'s U0 2 A M � ��o 0 oC7�0o m coo> +2ccaQmo = W c a E V cc z p _j coQ iiii5OdtoHQ Comm. No: 08061 M 07/07/08 Drawn: Revised: r M .O f+ C 0 13 O LL w E ca Q ca C co 0 CO m D E L= ._ E CO) O co !g 0 �1 O �- 0 c 0 cm CID 0 V Comm. No: 08061 Date: 07/07/08 Drawn: Revised: © 2008 HARVARD.40LL•Y, INC PO.00