08-957-013
SHEET METAL PLENUM FULL SIZE OF GRILLE NECK & MINIMUM OF 3" TALL PAINT INSIDE OF PLENUM BLACK STRAIGHT SUPPLY DUCT RETURN DAMPERED AIR DUCT SPIN TAP CONICAL TAP WITH -7 E PLAN MANUAL VOLUME -- DAMPER SANDPIT FLEX DUCT 6' MINIMUM, WITH STRAP METAL INNER LINING. I ; LAY -IN-/ DUCT COUNG T -BAR GRILLE BY (TYP ) OTHERS RETURN AIR GRILLE DUCT CONNECTION Q 5NO SCALE CONICAL TAP r- ROUND DUCT -'-- VOLUME DAMPER 45 DEG. MAIN DUCT DIRECTION OF AIR FLOW TYPICAL CONICAL TAP TYPICAL TAP LOW PRESSURE DUCT DETAILS O 4 NO SCALE R F PETE'S PLUG (TYP.) SRN _ v- GAUGE COCK (TYP. SHUT -OFF VALVE AUTOMATIC 2 -WA' VALVE BALANCING AND SHUT -OFF VALVE, \1<'.'� UNION (TYP.) VOLUME DAMPER CHW & HW PIPING OF SINGLE WATER COIL WITH AUTOMATIC 0 3 CONTROL AND 2 -WAY VALVE NO SCALE DOUBLE NUTS, TYPICAL 1/2" ALL THREADED STEEL HANGER RODS, TYPICAL CHILLED WATER SUPPLY & RETURN LINES. 0 /A. DUCT. BOTTOM RETURN W /1" FILTER HEATING COIL SECTION CHWS Ile COOLING COIL SECTION NOTES: 1. REFER TO MECHANICAL PLANS FOR DUCTS AND PIPES SIZES 2. HEATING COIL MAY NOT BE ON ALL UNITS. (REFER TO SCHEDULE.) 3. ELECTRIC HEATING COIL NOT REQUIRED ON ALL FAN COIL UNITS. TRAP 2" X 2" X 1/4" STEEL ANGLES BOLTED TO STRUCTURE ABOVE. SET TOP ATTACHMENTS IN CONCRETE FORMS WHERE APPLICABLE. SPRING VIBRATION ISOLATORS TYPICAL. FLEXIBLE CONNECTION, TYPICAL. INSULATED CONDENSATE DRAIN LINE TO DRAIN SYSTEM, SEE PLANS 3" DEEP AUXILIARY DRAIN PAN SIZED TO OVERLAP SIDES OF- UNIT AND EXTENDED PAST VALVE TRAIN. 02 FAN COIL UNIT NO SCALE INSULATION RIGID ROUND DUCT CEILING TILE \- DIFFUSER DUCTED RETURN GRILLE SIMILAR 01 DIFFUSER CONNECTION DETAIL NO SCALE EXIST. EF SCHEDULE DESIG./ SERVES ORIGINAL DESIGN CFM PRE T +B CFM NEW DESIGN CFM EF -12 25,305 42,560 42,560 MANUFACTURER /MODEL NO. TOTAL CFM RETURN CFM OUTSIDE AIR CFM CONICAL TAP WITH MANUAL DAMPER CONTRACTOR OPTION IF "X' > 3' -0" 1111204�3,q EXISTING AHU SCHEDULE DESIG./ SERVES UNIT TYPE ORIGINAL DESIGN CFM PRE T &B CFM NEW DESIGN CFM PRE FlLT. FINAL FILT. MANUFACTURER /MODEL NO. TOTAL CFM RETURN CFM OUTSIDE AIR CFM TOTAL CFM RETURN CFM OUTSIDE AIR CFM TOTAL CFM RETURN CFM OUTSIDE AIR CFM FCU -526 2115 11.4 400 350 - 50 TO 526 TILT NEUTRAL - 526 TILT 279 10.7 0 0 5TH FLR HORIZONTAL 400 350 50 150 110 40 400 350 50 30% NONE SEE FCU SCHEDULE PAT ROOM 10.1 0 0 50 - NEGATIVE - 0 LAT F DB/WB FCU -729 7TH FLR HORIZONTAL 500 450 50 270 195 75 500 450 50 30% NONE SEE FCU SCHEDULE PAT ROOM GPM (MAXIMUM) 1.3 1.6 v WATER PD (FT.) (MAXIMUM) 5.0 5.0 MINIMUM NO. OF ROWS /MAX. FINS PER INCH AHU -4 FCU'S HORIZONTAL 42,800 NONE 42,800 35,165 NONE 35,165 35,165 NONE 35,165 30% 90% EXISTING TO REMAIN C co aEAT F D13 / LAT F D13 55/90 55/90 EWT /LWT (DEGREES F) AIR CHANGE SCHEDULE ROOM VOLUME (FT. 3) ACTUAL S.A. CHANGES SUPPLY (CFM) RETURN (CFM) EXHAUST (CFM) ANSFERE (CFM) PRESSURE RELATIONSHIP NOTES CFM 12 "0 351 -560 CFM 14 "0 561 -850 S1 24x24 YES 526 2115 11.4 400 350 - 50 TO 526 TILT NEUTRAL - 526 TILT 279 10.7 0 0 50 - NEGATIVE - 729 2160 13.8 500 450 - 50 TO 729 TILT NEUTRAL - 729 TLT 297 10.1 0 0 50 - NEGATIVE - AIR DEVICE SCHEDULE DESIG. FRAME SIZE I OBD I FINISH I THROW I NECK SIZE MANUFACTURER /MODEL NO. REMARKS /NOTES 10 "0 201 -350 CFM 12 "0 351 -560 CFM 14 "0 561 -850 S1 24x24 YES WHITE 4 -WAY U.N.O NOTE 1 11TUS / TDC -AA ALUMINUM LOUVERED SUPPLY DIFFUSER /3,4,5,6,7,8 R1 24x24 YES WHITE N/A NOTE 2 TITUS / 350FL ALUMINUM RETURN GRILLE/3,4,5,6,7.8,9 E1 1, -3,/4" YES WHITE N/A NOTE 2 TITUS / 350FL ALUMINUM EXHAUST GRILLE/3.4,5.6,7,8,9 NOTES: 1. NECK* AIRFLOW 6 "0 0 -99 CFM 8 "0 100 -200 CFM 10 "0 201 -350 CFM 12 "0 351 -560 CFM 14 "0 561 -850 CFM *AND /OR DUCT RUNOUT 2. NECK* AIRFLOW 6x6 0 -100 CFM 8x8 101 -230 CFM 10x10 231 -360 CFM 1202 361 -450 CFM 16x16 451 -800 CFM 22x22 801 -1200 CFM *AND /OR DUCT RUNOUT 3. DIFFUSER RUNOUT SIZE SHALL BE DIFFUSER NECK SIZE, UNLESS OTHERWISE NOTED ON PLANS 4. PROVIDE SURFACE MOUNT HARDWARE IN ALL INACCESSABLE CEILING SYSTEMS 5. PROVIDE LAY -IN MOUNT HARDWARE IN ALL SUSPENDED CEILING SYSTEMS 6. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR LOC. OF DIFFUSERS 7• PROVIDE SELECTION BASED ON A MAXIMUM RADIATED NOISE OF NC -25 8• PROVIDE DIFFUSERS, GRILLES, AND REGISTERS MANUFACTURED FROM ALUMINUM UNLESS NOTED OTHERWISED. 9. 35 DEGREE BLADES, 0.50" SPACING. If 2121 Por306 rde Leon Blvd., Suite 350 FAN COIL UNIT SCHEDULE MARK FCU -526 FCU -729 SERVES 5th Floor Pat Rm 7th Floor Pat Rm CFM (MAX/MIN) 400 500 a ESP / TSP ( "WG) 0,5 0.5 FAN MOTOR HP (MIN) (1750 RPM) 1/4 .1/4 a D POWER SUPPLY (VOLTS/PHASE) 120/1 120/1 N FAN WHEEL TYPE FC FC DRIVE BELT BELT FAN RPM 1361 1534 TYPE COIL CHW CHW CFM 400 500 MAX. FACE VEL. (FPM) 500 500 TOTAL / SENS (MBH) 5.76/ 5.64 7.07/6.94 EAT F DB /WB 69.9/59.3 70.4/59.5 0 LAT F DB/WB 55.5/53.7 56.6/54.2 m = E 0 EWT F/LWT F 44/54 44/54 0 ._ ` CID o GPM (MAXIMUM) 1.3 1.6 v WATER PD (FT.) (MAXIMUM) 5.0 5.0 MINIMUM NO. OF ROWS /MAX. FINS PER INCH 6/12 6/12 TYPE / PH = PREHEAT, RH = REHEAT HW /RH HW /RH CFM 400 500 C3 MAX. FACE VEL. (FPM) (AT MAX AHU CFM) 500 500 C co aEAT F D13 / LAT F D13 55/90 55/90 EWT /LWT (DEGREES F) 180/160 180/160 z W GPM (MAXIMUM) 3.3 4.0 = PRESSURE LOSS (FT H2O MAXIMUM) 12 17 MINIMUM NO. OF ROWS/MAX. FINS PER INCH 1/12 1/12 OUTSIDE AIR CFM 50 50 TYPE 1" PLEATED FLAT 2" PLEATED FLAT N o EFFICIENCY (7.) (ASHRAE 52) 30 % 30 X E MAX. VELOCITY (FPM) 200 200 J P.D. (CLEAN /DIRTY) (INCHES W.G.) 0.10/0.30 0.10 /0.30 MANUFACTURER/MODEL NO. TRANE/ FCEB06 TRANE/ FCEB06 WEIGHT (LBS.) 128 128 UNIT MAXIMUM DIMENSIONS INCHE WI S WIDTH x HEIGHT x LENGTH THOU PLENUMS 50 x 13 x 30 50 x 13 x 30 NOTES 1,2 1,2 NOTES (FCU' - 1. FOIL -FACED 1" THICK INSULATION. COIL REMOVAL ACCESS PANEL ON BOTH SIDES. DRAIN PAN: STAINLESS STEEL, REMOVABLE, MAIN AND OVERFLOW CONNECTIONS. COILS: SLIDE IN /OUT ON RAILS. HORIZONTAL DRAW -THRU. 3 SPEED CONTROLLER INTEGRAL TO UNIT 2. PROVIDE HIGH WATER CONDENSATE SWITCH IN AUX. DRAIN PAN TO TURN OFF FCU SWITCH EQUAL TO LITTLE GIANT MODEL ACS-4. 3. PROVIDE CEILING UNIT (SIMILAR TO MAKE AND MODEL SCHEDULED) WITH EXPOSED CABINET, HINGED BOTTOM PANEL FOR FILTER ACCESS, AND OUTSIDE AIR & SUPPLY AIR FLANGED DUCT CONNECTIONS. GENERAL NOTES (FCU'S): A. ESP EQUALS SP LOSSES OF DUCTS PLUS DIRTY FILTERS MINUS CLEAN FILTERS. ISP EQUALS AHU SP LOSS WITH CLEAN FILTERS. TSP EQUALS ESP + ISP. B. FAN MOTOR NAMEPLATE HORSEPOWER SHALL NOT BE EXCEEDED AT SCHEDULED CFM AND TSP. C. IF ANY MANUFACTURER'S COOLING COIL PROMOTES MOISTURE CARRYOVER AT THE ALLOWABLE MAXIMUM FACE VELOCITY THEY SHALL OVERSIZE COOLING COIL FACE AREA TO PREVENT MOISTURE CARRYOVER AT THESE CONDITIONS. D. ACCEPTABLE MANUFACTURERS: TRANS, McQUAY, & YORK /JCI J J • D Oct oC Q Z W U W H z U Q 0 N M o 0 M Mr- o ° IT to Q � r N Lh . E U �r�rnr�r�aoo O O N 9 a rn io U W M a, 2> n U. :1 LLfN-oT tv O C 0 A m o 2 CZ7 too ca cu E0 w WO N z � .� ca iiti--j Odcn -¢ 0 Comm. No: 08061 co 07/07/08 Drawn: qdM C O r . 41000 M C O :c c O U. w E cc MIMMM Q IMMEMEM MW _cvs co O m = E E C a 0 ._ ` CID C E�Mo cl) CO) OO LM C co V Comm. No: 08061 Date: 07/07/08 Drawn: Revised: 11 6 t © 2008 HARVARD JOLLY, INC M3.00 i� i