08-823-002La Fire Sprinkler Piping o Plan SCALE: N.T.S Fire Sprinkler Pi in "_l Plan SCALE: /8 " =1' -0" N 1 /2 ±1 /8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE 2 -7/8" DIA. CPVC (73,0 mm) 1/2" (12,7 mm) 2 -1/4" DIA. 1/4" (6,4 mm) (57,2 mm) DESIGN CRITERIA CLASSIFICATION: MOUNTING HAZARD: PLATE MAX. HEAD COVERAGE: 225 SCOPE OF WORK 1/8" RELOCATED FIRE SPRINKLERS: 39 ADDED FIRE SPRINKLERS: 16 (3,2 mm) - ALL MATERIALS: HEADS, PIPE AND HANGERS ARE PER NFPA 13. LEGEND SERIES TY FRB 1 -5/16" (33,3 mm) 1 -1 /16" (27,0 mm) G 161 rzwA r24" I I ID, \ RS GREATER THAN NGTH SHALL BE D BY A HANGER. SCHEDULE 1. EXISTING DROP TO BE REMOVED. 2. EXISTING BRANCHLINE. 3. 1" ARMOVER.* 4. 1" DROP, 5. NEW FIRE SPRINKLER HEAD Typical Relocation Detail NO SCALE W, r;] '" .ARMOVERS GREATER THAN 24 IN LENGTH SHALL BE SUPPORTED BY A HANGER. ATTACH COUPONS FOR FIELD INSPECTOR. SCHEDULE 1. NEW MECH -TYPE TEE. 2, EXISTING BRANCHLINE. 3. ARMOVER." 4. 1" DROP. 5. NEW FIRE SPRINKLER HEAD Typical Relocation Detail NO SCALE GENERAL NOTES DESCRIPTION CPVC XL 40 ALL PIPE TO BE: X DESIGN CRITERIA CLASSIFICATION: OFFICE HAZARD: LIGHT HAZARD MAX. HEAD COVERAGE: 225 SCOPE OF WORK RELOCATED FIRE SPRINKLERS: 39 ADDED FIRE SPRINKLERS: 16 OUTLETS PLUGGED: - ALL MATERIALS: HEADS, PIPE AND HANGERS ARE PER NFPA 13. LEGEND EXISTING PIPE - - - - NEW PIPE NEW HANGER -�- NEW QUICK RESPONSE SPRINKLER NEW ARMOVER �--f -Q No. Date Revisions By Water Supply Information Design Criteria Sprinklers/ Spacing 1 5 -12 -08 SUBMIT FOR APPROVAL JRGN Static Pressure - System No. Symbol Qty Size K Temp Description SIN 2 5 -27 -08 CITY COMMENTS JRGN Residual Pressure - Design Area Area #1 Area #2 55 1/2" 5.6 155 TYCO -QUICK RESPONSE WHITE TY -FRB SEMI REC PENDENT TY -3231 Pitot Reading - Density - - Flow In G.p.m. - Design Area S.f. - - Date Of Test 1 - Psi Req'd 0 City Main - - Time Of Test - Gpm Req'd ® City Main - - Test Taken By - Gpm Req'd 0 Basr - - - No. Spkr. In Dsgn. Area - - Hydrant Location - Elev. ® Highest Spkr - - - Domestic /outside Hose - - - 55 Total This Sheet FIRE PROTEC'riON GENERAL NOTES 1. FIRE PROTECTION SYSTEM TO ZOM?LY \VITH NFPA 13, AND ALL APPLICABLE.STATE AND LOCAL: CODES. _ : 2. ADHERE TO AND OBTAIN ALL PERMITS, LICENSES AND GOVERNMENT REQUIREMENTS. 3. FINAL INSPECTION AND APPROVAL BY LOCAL FIRE DEPARTMENT, AND ARCHITECT /ENGINEER. 5. CUTTING OF STRUCTURAL AND /OR ARCHITECTURAL MEMBERS TO BE DONE ONLY WITH THE WRITTEN APPROVAL OF THE ARCHITECT. 6. PIPE ROUTING SHOWN SHALL BE USED AND ANY ADDITIONAL OFFSETS OR FITTINGS REQUIRED FOR PROPER INSTALLATION, COORDINATION WITH OTHER TRADES, AND /OR TO MAINTAIN PROPER CLEARANCES SHALL BE PROVIDED. VERIFY EXISTING STRUCTURAL, MECHANICAL, ELECTRICAL INSTALLATIONS AND AVOID ANY /ALL OBSTRUCTIONS OR INTERFERENCES WITH FIRE PROTECTION PIPE ROUTING. 7. FIRE STOP ALL PENETRATIONS OF SMOKE/FIRE WALLS, CEILINGS, FLOORS, ROOFS, ETC. FLASH AND COUNTERFLASH ROOF PENETRATIONS. (SEE FIRE RATED PIPE PENETRATION DETAIL). 8. PROVIDE ACCESS PANELS TO ALL VALVES ABOVE NON - ACCESSIBLE CEILINGS AND CHASES. 9. SPRINKLER HEADS ARE TO BE COORDINATED WITH ALL EXISTING /NEW DIFFUSERS, SPEAKERS, LIGHTING FIXTURES AND CEILING SYSTEMS. 10. METHODS OF HANGING PIPES, HEADERS AND BRANCHES SHALL BE IN ACCORDANCE WITH N.F.P.A. 13. 11. AUTOMATIC SPRINKLER TEMPERATURE RATINGS OF FUSIBLE ELEMENTS TO BE IN ACCORDANCE WITH N.F.P.A. 13. 12. ALL VALVES FOR FIRE SERVICE SHALL BE LISTED BY THE UNDERWRITER'S LABORATORIES, INC. AND THE FACTORY MUTUAL LABORATORIES. VALVES SHALL BE FACTORY MARKED "UL" AND "FM ", 175 WORKING PRESSURE. 13. ALL VALVES ON THE FIRE PROTECTION SYSTEM TO BE ELECTRICALLY SUPERVISED. TYPE AND EXACT LOCATION OF FLOW, PRESSURE AND SUPERVISORY SWITCHES SHALL FACTORY MARKED "UL" AND "FM ", 175 WORKING PRESSURE. 14. ALL POWER WIRING SHALL BE ACCOMPLISHED UNDER THE ELECTRICAL DIVISION. ALL CONTROL AND INTERLOCK WIRING SHALL BE ACCOMPLISHED UNDER THIS SECTION OF THE SPECIFICATIONS IN ACCORDANCE WITH THE REQUIREMENTS IN THE ELECTRICAL DIVISION. COORDINATE ALL ELECTRICAL ITEMS WITH ELECTRICAL CONTRACTOR AND INSURE PROPER COORDINATION. 15. SPRINKLERS SHALL COVER THE ENTIRE AREA OF THE ROOM INCLUDING ALCOVES. SPRAY SHALL NOT BE BLOCKED BY WALLS OR PARTITIONS. 16. ALL SPRINKLER HEADS MOUNTED IN CEILING SHALL BE LOCATED A MINIMUM OF 4" AWAY FROM ANY WALLS, CEILING HEIGHT CHANGES OR ANY OTHER VERTICAL INTERSECTING SURFACE. 17. PIPE SHALL BE REAMED AND CLEANED BEFORE ASSEMBLY. 18. MAINTAIN A MINIMUM OF 18 INCHES FROM THE BOTTOM OF THE SPRINKLER DEFLECTOR TO THE TOP OF STORAGE/FILE STORAGE. 19. PROVIDE SPRINKLERS ABOVE AND BELOW EXPOSED DUCTWORK 4 FEET OR WIDER "tqco Fire & Building Products Technical Services: Ter: (8001381-9312 1 Fax: (6WJ 791.5500 Series TY -FRB - 2.81 4 "2, 5.6, and 8.0 K- factor upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The S;,nes TY -FRS, 2 8, 4 2.5 6, and 8,0 K•tactar, Upright and Pendent Sprinklers ctescnbed+n this data sheet are autck response - standard cover- age, decorat va 3 mm glass bulb type Spray sprinklers designed for use in fight or orcin,ary hazard, ccmmerc.al cccuparciii such as banks, hors's, shopping ma'ls, Eli, toned when exposed to corrosive al• mospieres. Allhcugh corrosion reSis- ta ^t Coaled spnn k:ers hate passed the standard corrosicn tests of Me appil- =Ae apprevat agencles, the testing is not representative of all possible cor- rosive atntuspheres. Consequently, it is'ec,,mmer,dir_,J that the end user be consulted with respect to the sudabil,ty of 11he5e ccatings for any given cflrro- sive envim -nmenl The ettects of ambi- ent tenp?rature, concentraticn cf rhem-cals, and gasi'chemcrd velocity, should be considered, as a mnmurr,, The re^etsed version of the Senes along w2h the corrosive nature of the TY•FRB Pendent Sprinkler, where ap• pric•,.ble, is rntnnded for use in areas with a fir,ishied ceiling. It uses either a two-piece Style 10 (11`2 inch NPT) or Style 40 ('14 Inch NPT) Recrossed Es- culcheon witty 1,2 inch (12.7 rim) of recessed ad;ustment or up to 314 inch (19,1 mm) of total adjustment from the twee penctnt position, or a tio,piece Style 2011/2 Inch 1`11"T1 or Style 30 (314 inch NPT) Recessed Escutcheon with 1.4 Inch 164 mm) of recessed adiust- them cal to which the scar,nk`,erts will be emxsed_ A.n irrtenmed,ate krvel ver5ipns of the Serle,s T11-FR9 Pendent Sprinklers are detailed in Tccrinlcal Data Shoot TFP356. and Sprinkler G,:ards we Be- ta, ed In "re-,tin-cal Data Sheet TFP780 WARNINGS The Series TY -FRB SPrinAler3 de- scribed h&&a trust W lrtstafied ai.7 nrarntarned in cempt,snce wdh this ni or up to 1!2 Inch fl2,7 mm) of ctocu,Tre,nt, as wed as kwr:r theapplica- total adjustment from the hush pen • bte star*dards cl the Ivahonaf Fire Pro. dent posrt'on. The adjustment pro- tochnn AssocjaNm, in ad<t,'t,on to Vie videdbythe Recessed Escutcheonre- 57,11of any other sutbonheshav- Model /Sprinkler duces the accuracy to which the fixed Mg1unrdr.t ern, Failure to do so may pipe drops to the sprinklers must be impair the performance of these de- Identification cut vii resistant coat ngs, while Toe owrre, is respcins,t�re. for,mavtts,rt• Numbers appicabfe, are utilized to extend the iii hheir fee protevicinsystem and de- "lie of copper Ahoy sprinklers beyond v +sets 40 proper apershng cond,t'on. TY1131 - Upright 2.811 112'NPT that which would otherwise to chi The installing ctrtraclor or sprinkler TY1231 - Pendent 2.8K, 11Y'NPT manufacturer should be contacted TY213 - .2K, 112'NPT inch anY cuesflorl Pendent 2K, 1/2-NPT DISAPPROVED BYWY3231 - Pendent 6K, VVNPT Always refer f Tec7msal late SheetTFP7i70f tits 7f CSTAtL11' J#4JEtJrghit K,3/4'NPT WARNING' thsf rovdi cautLons dent K, W4 -NPT irfth res"ct to h ndri l - D AD E COUNTY FIREXP W-on c (sprinkle fem ponents, tmnp t rid rjg arid m- / -- O� SITE atalP wort can r W � IT a s rirrhror s st nertts and cause a >prrnhrer fo fail c gii _Ep'd F. i 6 tcoperatstnalre ltuatloncrcazusa ��, I,y it to operrte prom rely, DATE Project DR. LOPEZ �.�..�. ,� ,);.� SOUTH MIAMI HOSPITAL Fire s Is 6200 �.�;,���` 6200 SUNSET DRIVE SUITE 305 • t `•rl r ` ' • 'S U � MIAMI, FLORIDA RINK: :-R 1 N C. 01. systerri No. 1 Date: 5 -27 -08 Down By: Scale: All Fire Sprinklers 7570 N.W. 82nd Street Checked eY' All Fire Sprinklers AN: Miami Dade Medley,Florida 33166 Total A/s: 55 TEL:(305) 403 -4455 FAX:(305) 403 -4488 contract No. State Certification # 56528000012005 08 -43 FP-1 Of