08-1330-002An11 0 ,,
Am
A AC
ACOUSTICAL
ADJ
ADJUSTABLE
AFF
ABOVE FINISH FLOOR
AGG
AGGREGATE
A.C.
AIR CONDITIONING
ALUM
ALUMINUM
B BM
BEAM
BLK
BLOCK
BLKG
BLOCKING
BOT
BOTTOM
BLDG
BUILDING
BLKHD
BULKHEAD
C CAB
CABINET
CARP
CARPET
CLG
CEILING
CEM
CEMENT
CA
CENTER LINE
CER
CERAMIC
C.T.
CERAMIC TILE
CO,
CLEAN OUT
CL OR CLOS
CLOSET
COL
COLUMN
CONC
CONCRETE
CMU
CONCRETE MASONRY UNIT
CONST
CONSTRUCTION
CONT
CONTINUOUS
CG
CORNER GUARD
CU
CUBIC
D DEPT
DEPARTMENT
DIA
DIAMETER
DIM
DIMENSION
DN
DOWN
DS
DOWN SPOUT
DWG
DRAWING
DF
DRINKING FOUNTAIN
E E.A.
EXPOSED AGGREGATE
EA
EACH
EL
ELEVATION GRADE}
ELE
ELEVATION FACADE)
ELEV
ELEVATOR
EQ
EQUAL
EQUIP
EQUIPMENT
EXIST
EXISTING
EXP.JT. OR EJ
EXPANSION JOINT
EXP
EXPOSED
EXT
EXTERIOR
ELEC
ELECTRICAL
F FT
FEET
FIN
FINISH
FE
FIRE EX11NGUISHER
FEC
FIRE EXTINGUISHER CABINET
FHC
FIRE HOSE CABINET
FL
FLOOR
FD
FLOOR DRAIN
FLUOR
FLUORESCENT
FS
FULL SIZE
FV
FIELD VERIFY
FVC
FIRE VALVE CABINET
G GALV
GALVANIZED
GA
GAUGE
GC
GENERAL CONTRACTOR
GL
GLASS
GR
GRADE
GYP
GYPSUM
GYP BD
GYPSUM WALLBOARD
H HRDW
HARDWARE
HT
HEIGHT
HM
HOLLOW METAL
HORIZ
HORIZONTAL
I IN
INCH
INCAND
INCANDESCENT
ID
INSIDE DIAMETER
INSUL
INSULATION
INT
INTERIOR
INV
INVERT
L LAV
LAVATORY
LAM
LAMINATED
LT
LIGHT
LTWT
LIGHT WEIGHT
LF OR UN FT
LINEAR FEET
M MAT
MATERIAL
ML
MATCH LINE
MAX
MAXIMUM
MECH
MECHANICAL
MET OR MTL
METAL
MIN
MINIMUM
MISC
MISCELLANEOUS
MACH
MACHINE
MANUF
MANUFACTURER
NOM
NOMINAL
NIC
NOT IN CONTRACT
NTS
NOT TO SCALE
0 OFF
OFFICE
OPNG
OPENING
OD
OUTSIDE DIAMETER
OC
ON CENTER
OH OR OPP.HD.
OPPOSITE HAND
P PR
PAIR
PASS
PASSENGER
PENT
PENTHOUSE
PC
PRECAST
Pi
PANEL JOINT
PLAS
PLASTER
POL
POLISHED
PMLD
PREMOULDED
PNL
PANEL
Q QT
QUARRY TILE
QTM
QUARRY TILE MINIATURES
RAD
RADIUS
R
RISER
REINF
REINFORCED
REWD
REQUIRED
RF
ROOF
RD
ROOF DRAIN
RM
ROOM
RD
ROUGH OPENING
REFL OR REF
REFLECTED
S SECT
SECTION
SHT
SHEET
SHT MET OR SM
SHEET METAL
SIM
SIMILAR
SQ
SQUARE
STD
STANDARD
SS
STAINLESS STEEL
STL
STEEL
STOR
STORAGE
STRUCT
STRUCTURAL
SUSP
SUSPENDED
SPECS
SPECIFICATIONS
T TEL
TELEPHONE
TEMP
TEMPERED
T
TOILET
T
TREADS
TYP
TYPICAL
TR
TELEPHONE RECEPTACLE
THK
THICK
V VERT
VERTICAL
VT
VINYL 11LE
VB
VAPOR BARRIER
VWC
VINYL WALL COVERING
W -GYP
WALL COVERING - GYPSUM BOARD
VWC-PLAS
WALL COVERING - PLASTER
WC
WET COLUMN
WP
WATERPROOFING
WD
WOOD
W/
WITH
W/o
WITHOUT
WC
WATER COOLER
Y YD
YARD
HINAMIXMIS91
i
M
WALL CONSTRUC11ON WALL TY •3
DETAIL NUMBER
EXTERIOR & INTERIOR,
ELEVA-f +>, 0&-
TOP OF CONCREIE
SLAB 11O
DRAWING REVISIONS 1 REVISION NUMBER
a �� r
INDEX SHEET
SCALE:
ASSHOWN
INSULATION
CONCRETE
GRAVEL or
CEMENT
CONCRETE
Blanket
PRECAST
CRUSHED
MORTAR
FLOOR
LIFE SAFETY PLAN - AREA "B"
A -1.0
STONE
PLASTER
PLAN - DEMOLITION
A
I
FLOOR
PLAN - NEW WORK
!4 _
EARTH
TILE
SOLID CONC.
CONCRETE
MARBLE
Ceramic or
MAS. UNIT
MASONRY
Structural
UNIT
... ....
i
SHEET
WOOD
BRICK
METAL
FhMed
Blocking
Blocking
Large
_. .._ ......
Continuous
r
Intermittent
Scale
GLASS
GLASS
E
INSULATION
Small
Large
Rigid
Scale
Scale
I
Sim
STEEL
PLYWOOD
Small Scale
Large Scale
d
4
M
WALL CONSTRUC11ON WALL TY •3
DETAIL NUMBER
EXTERIOR & INTERIOR,
ELEVA-f +>, 0&-
TOP OF CONCREIE
SLAB 11O
DRAWING REVISIONS 1 REVISION NUMBER
a �� r
I81l:42:1.r.»4
PROJECT
41 0
rr•.. w -.. i -- r S�
6200 73 STR=
MIANU, FLORIDA
C.UMM. NU.
INDEX SHEET
SCALE:
ASSHOWN
ARCHITECTURE
11-18-2008
DRAWN:
LS -2.0
PARTIAL SECOND
FLOOR
LIFE SAFETY PLAN - AREA "A"
LS -2.1
PARTIAL SECOND
FLOOR
LIFE SAFETY PLAN - AREA "B"
A -1.0
PARTIAL SECOND
FLOOR
PLAN - DEMOLITION
A -2.0
PARTIAL SECOND
FLOOR
PLAN - NEW WORK
A -3.0
PARTIAL SECOND
FLOOR
CEILING PLAN
A -4.0
WALL TYPES & DETAILS
I81l:42:1.r.»4
PROJECT
41 0
rr•.. w -.. i -- r S�
6200 73 STR=
MIANU, FLORIDA
C.UMM. NU.
40053.100
SCALE:
ASSHOWN
DATE:
11-18-2008
DRAWN:
JCR
CHECKED:
BNH
CADD FILE: 1-1:1NS11111TIONAL
DRAWING TITLE:
1
SHEET NO.
A=911