08-1308-001tqC01Fire &Building Products Tochnical Servicos: Tol: (80% 381 -9312 f Fax: (800) 791 -5500 Series RFII — 5.6 K- factor "Royal Flush ll" Pendent Concealed Sprinklers Quick & Standard Response, Standard Coverage General Description The Tycall, Series RFII Quick Response (3 mm bulb) & Standard Response (5 mm bulb), 5.6 K- Factor, "Royal Flush It* Concealed Pendent Sprinklers are decorative sprinklers featuring a flat cover plate designed to conceal the sprinkler. It is the bast choice for archi- tecturally sensitive areas such as ho- tel lobbies, office buildings, churches, and restaurants, Protective Cap is temporarily removed for installation, and then it can be re- placed to help protect the sprinkler while the ceiling is being installed or finished. The tip of the Protective Cap can also be used to mark the center of the ceding hole into plaster board. ceiling tiles, etc, by gently pushing the ceiling product against the ProteC- tive Cap_, when the ceiling installation is complete the Protective Cap is,re- moved and..the Cover Plate Assembly installed. .. • . • . . As an option, the Series RFII Standard Response (5 mn1 bulb) "Royal Flush 11" Each unit includes a Cover Plate As- sembly that conceals the sprinkler op- Conceited Pendent Sprinklers may be Floor Plan - erating components above the ceiling. fitted with a silicone Air and Dust, Seal (Ref. Fig. 5), The Air and Dust Seal is Technical The separable two -piece design of the Cover Plate and Support Cup Assem- intended for sensitive areas where it Data blies allows installation of the sprin- is desirable to stop air and dust travel -- thmu h the cover fate from the area 9 p Approvals: klers and pressure testing of the fire protection system prior to installation above the ceiling. UL and C -UL Listed- FM Approved of a suspended ceiling or application— " T MIN. NYC under MEA 353 -01 -E. LPCB (Ref. No. 094a/03 for TY3551 & of the finish coating to a fixed ceiling. They also permit removal of suspend- - - eno The. Series RF# Concealed Pvn# 094a/10 fQr TY3631) ed ceiling panels for access to building service equipment without having to Spnnklers 'described herein must be instal l2dand maintained incompliance The approvals apply only to the ser- vice conditions indicated in the De- first shut down the fire protection sys- with -this document and with the appli- sFgn Criteria section. tem and remove sprinklers. cable ,standards of the National Fire Approvals for Air & Dust Seal: Also. the two-piece Protection anyauthoritties having' UL and C-U8 Listed for use with the Sprinkler er p 1t2einch (12,7 mm) of vertical adjustnt2nt, to Jurisdiction. Failure to do so ma}ilmparr RFII (TY3551), Standard Response provide a measure of flexibility with re- the performance of these devices. Concealed Sprinkler. gard to which the length of fixed pipe The owner is responsible for maintain- Maximum Working Pressure: drops to the sprinklers must be cut. ing their fire protection system and de- Maximum 250 psi (17,3 bar) by UL, The Series RFII Sprinklers are shipped -vices in._-proper Operating gQnC6tion- The installing contractor or sprinkler C -UL, and NYC. Maximum 175 psi (12,1 bar) by FM and LPCB. with a Disposable Protective Cap, The manuiactvrer should ba contacted with any questions. Temperature Rating: °171681C IMPORTANT Always refer to Technical Data Madel/Sprinkler 155 - Sprinkler 139'F159`C - Plate 200`F/93'G - Sprinkler Sheet TFP700 for the INSTALLER WARNING" that provides cautions Identification 165 °F /74 °C - Plate with respect to honoring rued instal- nation of sprinkler systems and com- 'Number Discharge Coefficient: K- 5.6 GPM /psl1f2 (80,6 LPMfbartrz) ,ponents. Improper handling and In- Adjustment: stal /ation can permanently damage TY3551 (5 mm bulb) 112 inch (11 2,T mm) a sprinklersystem or its components TY3531(3mm bulb) Finishes: and cause the sprinkler to fail to Refer to Ordering Procedure section. operate in a fire situation or cause It to operate prematurely. Page i of d MAY, 2008 TFP181 � I I I I I � I 2111 I _ r - - - - -- --�- I cv I I I I I =1 I NI I I I I I T. I Nor I I I I I I I I Enlarged Floor Plan - H.C. Room New Fire Sprinkler Piping Plan � I I I I I I I I I I I I I I I I I I I I I I 2" I I I I I I I I I I I I I I I 1 Enlarged Floor Plan Floor Plan - H.C. Room New Fire Sprinkler Piping Piping Plan 4' -0" MAX. 12' -0" MAX. 3" MIN. 1-11271-18" f L - - -� T MIN. A 1 1 SPRINKLER HEAD I I STEEL PIPE LHANGER NI 1" I E0 1n I --0 I I I I I I 2" I I I I I I I I I I I I I I I 1 Enlarged Floor Plan Floor Plan - H.C. Room New Fire Sprinkler Piping Piping Plan ;9- NORTH -ii NORTH 1 I I I I I I 1 I I I I I - r-- ----- � r -P _ b I r- I I _I I r-I I I DI J T. I I I I I II I I I Enlarged Floor Plan - H.C. Room Demo Fire Sprinkler 3' -0" MAX. — — — — Piping Plan 4' -0" MAX. 12' -0" MAX. 3" MIN. I I I I I I I I I I I I I I I I I�I I I I _I I r-I I I 0 11� --0 JI O-J I I I I I I COMPONENTS 1. ADJUSTABLE HANGER RING Hanger Detail 1 Not To Scale ALL THREAD ROD 1ATR) ATTACHED TO CONCRETE 3/8" POWDER NCTUATED PIN & 3/8" ROD CPLG. FOR USE WITH 4" PIPE & SMALLER). Hanger Location Detail ..... PIPE SIZE A B: - - C 1' 3' -0" MAX. — — — — 1- 1-1/4" 4' -0" MAX. 12' -0" MAX. 3" MIN. 1-11271-18" 5 -0" MAX. 15' -0' MAX. T MIN. A B, SPRINKLER HEAD STEEL PIPE LHANGER ' MAXIMUM HANGER SPACING FOR THREADED LIGHTWALL STEEL PIPE IS 12' -0" FOR ALL PIPE SIZES There Shall Be Not Less Than One Hanger For Each Section Of Pipe. Where Sprinklers Are Spaced Less Then Eft Apart, Hanger Spacing Shall Be Permitted Up To 12 Ft. Starting Lengths Less Than 6ft Shall Not Require A Hanger, Unless The End Line Of A Side Fed System Or Where An Intermediate Cross Main Hanger Has Been Omitted. Hanger Location When The Sprinkler Discharge Pressure Exceeds 100 Psi. The Hanger's Rod Shall Be Located Against The Pipe To Prevent The Pipe To Move Upward. The Unsupported Length Between The End Of The Pipe And The Pendent Sprinkler Or The Drop Nipple The Distance Shall Not Exceed 12 Inches. The Cumulative Horizontal Length Of An Unsupported Armover To A Sprinkler, Sprinkler Drop , Or Sprig -up Shall Not Exceeds 24 Inches Except When The Sprinkler Discharge Pressure Exceeds 100 Psi Then The Unsupported Length Shall Not Be Greater Than 12 Inches. Toggle Hangers Shall Be Permitted Only For The Support Of Pipe 1 -1/2" Or Smaller. NFPA Pamphlet #13 (2002) When Sprinklers Are Located Under Hvac Duct, Sprinkler Pipe Is Allowed To Be Hung To The Duct Support. Fire Protection Criteria ALL MATERIALS & INSTALLATION SHALL BE PROVIDED IN ACCORDANCE WITH NFPA 13 (2002) REQUIREMENTS. NORTH SPRINKLERS SHALL BE INSTALLED PER MANUFATURES REQUIREMENTS AND DESIGN CRITERIA IS IN ACCORDANCE WITH NFPA 13 (2002) FOR LIGHT. NEW CONSTRUCTION LEGEND SYMBOL DESCRIPTION K PIPE NEW SPRINKLER HEADS FROM EXISTING LOCATIOI O EXISTING SPRINKLER HEADS TO REMAIN — — — — EXISTING TO REMAIN 1/2" NEW CONSTRUCTION 155 CONNECT TO EXIST. AT THIS POINT Enlarged Floor Plan - H.C. Room - NewFire Sprinkler Piping Plan ki NORTH INTERIOR SPRINKLER PIPE TO BE XL STEEL. ALL HANGER MATERIALS AND SPACING SHALL COMPLY WITH NFPA 13 (2002). Scope Of Work:_ ADD AND /OR RELOCATE FIRE SPRINKLERS IN BATHROOMS. NOTE: FIRE SPRINKLER CUT SHEETS SHALL BE AVAILABLE ON SITE FOR FIELD FIRE INSPECTOR. V B 8 °�7 fl II r �t T� Key Plan S! ppRESSION SYSTEM APPROVED BY MIJ\ml�DAD.E COUNTY FIRE DEPARTMENT SPRINKLER I.D. NO. 1.0. NO. DATE SYM TY SIZE K TEMP MODEL SIN 0 2 1/2" 5.6 155 TYCO RFII Wht Concealed Pd TY3531 �2 I Total Sprinklers J J NF , NORTH 1 11/04/08 1 EDR I SUBMIT FOR REVIEW INO.1 DATE 113Y1 REVISIONS & APPROVALS 1 Robertson Fire Protection, Inc. 7795 Northwest 54th Street Miami, Florida 33166 Phone: 305 - 593 -2993 Fire Sprinkler Project For: SMH 7th Floor PAV Upgrades 6200 SW 73rd Street South Miami, Florida 33143 -4989 Drawn I Date REL 11/04/08 SCALE Fire Sprinkler Plan As Noted CONTRACT NO. e r' I �4 0 M O r W 0 N 0 1 . t • 4 •. • ..