Loading...
08-1242-0014 " Number of Sprinklers Total This Sheet: 002 Total This Job: 002 Symbol No. Description: 002 TYCO FRB QR WHITE CONC. PEND.(K =5.6 , OR. 1/2 ",155 D. Drawn By: F Z Scale: 1/411= 1 rr -0'r Date: 11.04.2008 Approval By: J.T. Symbol I Revisions: Date: 11,8 AREA OF WORK EXISTING PIPING AND EXTEND ' BRANCH PIPING TO NEW D LOCATION. pA 10 t C.A. No.2435 7290 NW 44th STREET Miami, FL. 33166 Tel. (305) 994 9220 Fax. (305) 994 9210 SEAL: Jorge de la Torriente P.E. Reg.No.: 18690 \C'0NGRETE ANCHOR 6ALL T"READ ROD _PIPE RING HANGER DETAIL BASIS OF DESIGN OCCUPANCY - OFFICES AREA CLASSIFICATION OF CONTENT - LIGTH HAZARD (NFPA 13 -2002) HANGER LOCATE)N DSf R. GENERAL NOTES: PIPE SIZE A B• 1. All Pipe Locations are to be Field Measured Symbol Description -0 UAY. Prior to Fabrication and Installation by Sprinkler Contractor. O Hydraulic Reference Points 1 -1 4 2. All Dimensions Shown are Center to Center. -0 UAZ Elev. Below Top of Steel UiN 3. High Temperature Heads are to be Field 8 -61 Elev. Above Finished Floor 11 Located Where Required. N 4. All Pipes and Hangers are to be Installed A B. Elev. of Top of Steel — per NFPA #13. O Ceiling Height 5. Hangers are to be U.L. Listed and F.M. ; = Denotes Hanger Location Approved. 0 Rise up or down Number of Sprinklers Total This Sheet: 002 Total This Job: 002 Symbol No. Description: 002 TYCO FRB QR WHITE CONC. PEND.(K =5.6 , OR. 1/2 ",155 D. Drawn By: F Z Scale: 1/411= 1 rr -0'r Date: 11.04.2008 Approval By: J.T. Symbol I Revisions: Date: 11,8 AREA OF WORK EXISTING PIPING AND EXTEND ' BRANCH PIPING TO NEW D LOCATION. pA 10 t C.A. No.2435 7290 NW 44th STREET Miami, FL. 33166 Tel. (305) 994 9220 Fax. (305) 994 9210 SEAL: Jorge de la Torriente P.E. Reg.No.: 18690 \C'0NGRETE ANCHOR 6ALL T"READ ROD _PIPE RING HANGER DETAIL BASIS OF DESIGN OCCUPANCY - OFFICES AREA CLASSIFICATION OF CONTENT - LIGTH HAZARD (NFPA 13 -2002) HANGER LOCATE)N DSf R. PIPE SIZE A B• C 1 -0 UAY. -0 f[AE imt 1 -1 4 4 -0 UAL -0 UAZ UiN -1 TH a 5- UAL 15 -0 UAL 11 UDt A B. S M11M HEAD C LEER • 11Am1ui1 HANGER 1111 1115 Foa THREADED ficaneu 1W PIPE IS 12' -0' FOR Ail. PIPR q"Eq There Wan be not fear than one hanger for each section of pipe. Vhm sprinkiem — spaced leas than an apart, hanger spacing amn be permitted up to 12 R Starting lengtbs leas than Oft ahall not require a hanger, nukes the end line of a aide fed system or where an intermediate croae main hanger bas been omitted HANGER LOCATION VW THE SPNDiSI,Sa DL9 THE PEMUR8 M= 100 PSL The hunger's rod slab be located agehrt the pipe to prevent the pipe to move upward. The unsupported length between the end cf the pipe and the pendent Bp�rinkleer or the drop nipple the distance Than not exoeed 12 The cumulative horizontal length of an unsupported armorer to a sprinkle: sprtdder drop. or sprig —ap shaD not esneeds 24 inches e=ept when the aprinldar discharge pmpsure meads 100 PSI Wan the unsupported length alnD not be greater than 12 inches Mhanger sball be permitted only for the rapport of pipe or smaller. NFPA pnmphkt 113 1D9 wction 0-214 when eprtnidera are located under HVAC duct , sprbkIer pipe is allowed to be hung to the duct enpport. SPRINKLER LEGEND :OMPONENTS THREAD ROD ;ONCRETE ANCHOR 3ALV. HANGER RING. 3. Hanger Detail #01 FOR OFFICES AREAS E O DENOTES EXISTING HEADS N 0 DENOTES NEW HEADS R O DENOTES RELOCATED EXISTING HEADS — — DENOTES EXISTING LINES DENOTES NEW LINES NO SCALE NOTES: 1. THE FIRE PROTECTION SYSTEM DESIGN ON THIS DRAWING IS BASED ON NFPA 13 (2002) –L.H. 2. ALL PIPES HANGERS AND HANGER LOCATIONS TO BE INSTALLED IN ACCORDANCE WITH NFPA 13 (2002). 3. ALL TAMPER AND FLOW SWITCHES ARE EXISTING. 4. FITTINGS TO BE C.I.; PIPES 1"-2" TO BE LIGHTWALL THREADABLE. PIPE 2Y2" AND ABOVE TO BE SCH. 10. JOB NAME: DENTAL OFFICE SUITE 402 (ozov O 12 SUNSET DRIVE, SOUTH MIAMI, FLORIDA 1 33143 m a, z LL 0 z Drawing Title: F- SUITE 402 0 _ a U) v 1 I A r 1+ a � r� R+D �