Loading...
08-1177-037ELECTRICAL LEGEND ABBREVIATIONS /SUFFIXES LIGHTING FIXTURES A.F.F. ABOVE FINISHED FLOOR O LIGHTING FIXTURE IDENTIFICATION. SEE SCHEDULE A.F.G. ABOVE FINISHED GRADE / • HID OR FLUORESCENT DOWN LIGHT BD. BOARD 0 ACCENT TYPE LIGHT FIXTURE C. CONDUIT Q a HID OR FLUORESCENT WALL MOUNTED LIGHT FIXTURE CAB. CABINETQ,J -© RECESSED / LAY -IN MOUNTED FLUORESCENT LIGHT FIXTURE C.B. CIRCUIT BREAKER ® SURFACE OR PENDANT MOUNTED FLUORESCENT LIGHT FIXTURE CKT. CIRCUIT T WALL MOUNTED FLUORESCENT LIGHT FIXTURE E EXISTING FLUORESCENT SURFACE OR PENDANT MOUNTED FLUORESCENT STRIP E.C. EMPTY CONDUIT / Q HID DOWN LIGHT ON EMERGENCY OR NIGHT LIGHT CIRCUIT E.W.C. ELECTRIC WATER COOLER , HID OR FLUORESCENT WALL MOUNTED LIGHT FIXTURE ON EMERGENCY OR NIGHT LIGHT CIRCUIT F.A. FIRE ALARM WALL MOUNTED EMERGENCY LIGHT BATTERY PACK G.F.I. GROUND FAULT INTERRUPTER Os� DIMMING LIGHTOLIER RECESSED /FLUORESCENT LIGHT FIXTURE ON EMERGENCY LIGHT CIRCUIT OR BATTERY BACK -UP GND. GROUND 0 SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE ON EMERGENCY LIGHT CIRCUIT OR BATTERY BACK -UP HID HIGH INTENSITY DISCHARGE Q 50 277 RECESSED /FLUORESCENT EHPA STAND -BY EMERGENCY LIGHTING HPS HIGH PRESSURE SODIUM SPS2GRAVA26U277 -H1 e EXIT LIGHT I.G. ISOLATED GROUND NO DIMMING I WALL MOUNTED EXIT LIGHT SHADED QUADRANT INDICATES NUMBER OF FACES. LT. LIGHT ARROWS AS SHOWN OR REQUIRED. LTG. LIGHTING 2X13W DOWNLIGHT O WIRING 2 MCB MAIN CIRCUIT BREAKER 277 28 1, 2 , 3 �� BRANCH CIRCUIT OR FEEDER WIRING IN CONDUIT, NO TICKS INDICATES 2 u 12 MLO MAIN LUGS ONLY CONDUCTORS 6 I u 12 GROUND IN 3/4" CONDUIT. TICK MARKS WHEN SHOWN, MT. MOUNT / INDICATES NUMBER OF u 12 CONDUCTORS IF OTHER THAN THREE, (1) INDICATES GROUND, CONDUIT LARGER THAN 3/4' 6 CONDUCTOR LARGER THAN u 12 SHALL BE NO DIMMING AS INDICATED. MTG, HT. MOUNTING HEIGHT N.E.C. NATIONAL ELECTRICAL CODE A -1 1-'5,- , HOME RUN TO PANEL 'A" = PANEL DESIGNATION, 1,35 - CIRCUIT NUMBERS. U.ON. MINIMUM SIZE OF 3/4'C AND MAXIMUM OF THREE CIRCUITS PER HOMERUN N.I.C. NOT IN CONTRACT f� f� FLEXIBLE CONDUIT P.A. PUBLIC ADDRESS 3.6 CONDUIT RUN CONCEALED IN CEILING OR WALLS PNL. PANEL — CONDUIT RUN UNDERGROUND OR IN SLAB RECEPT. RECEPTACLE - - - - -- CONDUIT RUN EXPOSED S.D.B.C. SOFT DRAWN BARE COPPER C -- CAPPED CONDUIT SW. SWITCH —i1- SYSTEM AND /OR EQUIPMENT GROUNDING CONDUCTOR U.O.N. UNLESS OTHERWISE NOTED � GROUNDING ELECTRODE & CONDUCTOR SYSTEM V.P. VAPOR PROOF NP! IH -13 SPACE SERVED BY NORMAL POWER CIRCUIT IH -13 PACK. EP IEH-i AND BY EMERGENCY POWER CIRCUIT IEH -I W.P. WEATHER PROOF (NEMA SP ENCLOSURE) X.P. EXPLOSION PROOF (CLASS TO MEET N.E,C.) FIRE ALARM DEVICES N.L. NIGHT LIGHT Q FIRE ALARM PULL STATION (48' A.F.F,) DATA, COMMUNICATIONS AND SECURITY L'J FIRE ALARM SPEAKER WITH STROBE LIGHT 75 CANDELA MINIMUM (80'AF,F.) FIRE ALARM STROBE LIGHT - 75 CANDELA MIN. - (80 " A.FF.) O TELEPHONE AND DATA OUTLET (4 "X 4'X 21/2" OUTLET BOX)(18' A.F.F.) "C. ® SMOKE DETECTOR (PHOTOELECTRIC TYPE) PROVIDE A 3/4 STUB OUT AT 6" ABOVE CEILING. 2 PROVIDE EMERGENCY SAVING BALLAST AND LAMPS 0 HEAT DETECTOR (135 DEGREES FT /RR) ® TELEPHONE OUTLET (4'X 4 "X 2 I/2' OUTLET BOX)(IS' A.F,F.) 3. PROVIDE IN LINE FUSETO ALL FIXTURES PROVIDED WITH A BALLAST DD DUCT SMOKE DETECTOR ® TELEPHONE OUTLET FLUSH FLOOR MOUNTED Fs FLOW SWITCH V, INTERCOM ADMINISTRATIVE DISPLAY TELEPHONE OUTLET (18 'AFF) Ts TAMPER SWITCH ®P PUBLIC TELEPHONE (48' A.FF.) FACP FIRE ALARM CONTROL PANEL ®w WALL MOUNTED TELEPHONE OUTLET (60 "AFF.) © FIRE ALARM TWO WAY COMMUNICATION TELEPHONE JACK T� TELEVISION OUTLET (86' A,FF.) U.O.N. DH DOOR HOLDER SP CEILING MOUNTED SPEAKER SP SOUND REINFORCEMENT SYSTEM CEILING MOUNTED SPEAKER WIRING DEVICES rC__Al CARD ACCESS BOX (4 11/16 X 411/16 X 2 1/8' BOX, (42' AFF) DUPLEX RECEPT - 20 AMP NEMA 5 -20P (18" AF.F.) CCTV VIDEO SURVEILLANCE CAMERA COORDINATE MOUNTING HEIGHT WITH SDPBC DUPLEX RECEPT - DEDICATED CIRCUIT 20 AMP NEMA 5 -20P (18' A.FF.) KP KEY PAD BOX (4 II /16 X 4 11/16 X 2 1/2' BOX, 42" AFF.) QTv DUPLEX RECEPT FOR TV - 20 AMP NEMA 5 -2012 (86" AFF,) Q MOTION DETECTOR SINGLE RECEPT. - 20 AMP NEMA 5 -202 (18' AF.F.) ML MAGNETIC DOOR LOCK DUPLEX RECEPT. MOUNTED ABOVE COUNTER - 20 AMP NEMA 5 -2012 (44' AFF.) U.O.N. 0 TERMINAL CABINET - TYPE INDICATED QUAD - PLEX RECEPT. - 20 AMP NEMA 5 -202 (18' A.F.F.) ® TELEPHONE TERMINAL BACK BOARD QUAD - PLEX RECEPT. - DEDICATED CIRCUIT 20 AMP NEMA 5 -202 (18" AFF.) POWER EQUIPMENT ® DUPLEX RECEPT. - 20 AMP NEMA 5 -2012 AND TELECOM OUTLET IN DOUBLE GANG FLOOR BOX. HIGH VOLTAGE DISTRIBUTION PANEL BOARD 277/480V SPECIAL PURPOSE RECEPT, (18' A,F,F.) ® LOW VOLTAGE DISTRIBUTION PANEL BOARD 120/20BV A, B' C A - 250V, 30A, 4W ® HIGH VOLTAGE PANEL BOAR D 277/48OV. B - 250V, 50A, 4W. C - 250V, 50A, 5W. _ LOW VOLTAGE PANEL BOARD 120/208V. Q JUNCTION BOX 0' HD FUSIBLE DISCONNECT OR CIRCUIT BREAKER. NEMA 32 WHEN OUTDOORS. ZH WALL MOUNTED JUNCTION BOX 3660 3 -NO. OF POLES, 60- SWITCH SIZE, 50 -FUSE, NF- NON - FUSED, ■ -FUSE SIZE AS REQUIRED BY LOAD, ,,gi�pp PROVISION FOR FUTURE MODULAR FURNITURE SYSTEM OJT (U POWER JUNCTION BOX WITH (1) 3/4" CONDUIT WITH PULL STRING STUBBED UP ABOVE CEILING. ® MOTOR STARTER W /CONTROL XMFR, HOA SELECTOR SW. AND RED I-O (D TELEPHONE /DATA JUNCTION BOX WITH (2) 1' CONDUITS WITH PULL STRING STUBBED UP ABOVE CEILING. PILOT LIGHT, NEMA SIZE BY MOTOR. PROVIDE NEMA 4 ENCLOSURE WHEN OUTDOORS DEHUMIDIFIER ZJ COMBINATION MOTOR STARTER W/ DISCONNECT SWITCH OR CB. SAME ENCLOSURE AND ACCESSORIES AS INDICATED ABOVE oP SIX (6) GANG J.BOX RECESSED IN WALL (18'AFF TO CENTER) FOR CEILING PROJECTOR © CONTACTOR, SAME ENCLOSURE AND ACCESSORIES AS STARTERS Oi FLUSH POKE THRU WITH DUPLEX RECEPTACLE. FAN ® FLUSH POKE THRU WITH VOICE, DATA AND TV OUTLET. /C)/ MOTOR © PULL BOX If] TRANSFORMER S SINGLE POLE SWITCH - 20 AMP (48' A.FF.) PZM STRIP HEATERS BY MECH. CONTRACTOR S3 THREE WAY SWITCH - 20 AMP (48" A.F.F,) S4 FOUR WAY SWITCH - 20 AMP (48" A.F,FJ ® VAV BOX WITH ELECTRIC HEATER So DIMMER SWITCH 2000 WATTS 48' A,FF.) SF FAN SPEED CONTROL (48' AF.F.) SK KEY OPERATED SWITCH - 20 AMP (48' A.F.F.) NOTE: SP SINGLE POLE SWITCH WITH PILOT LIGHT - 20 AMP(48' A.F.F,) NOT ALL SYMBOLS USED IN THIS PROJECT. S MOTOR RATED SWITCH (WITH OVERLOADS) ST TIME CONTROL SWITCH SP SINGLE POLE LIGHT SWITCH WITH PILOT LIGHT - 20A(48 -AFF) PROJ. No. 18056-- FeCC0009?4 LOUIS J. AGUIRRE &_ ASSOCIATES P.A. CONSULT ft' 5ENGIHE�ERS 2600 DOUGLAS RD. - = = 30 T 6D5-- CORAL GABLES, FLOROA - - 33134 TELEPHONE: (305) 444 -1679 FAX: (3C5) x'48 -1405- - E -MAIL ADDRESS: CRALMAILQLJAAPA QOM o Revisions: 0 0 0 0 4 Z W � V of a ul m of ^ m g� C� G/1 0 o FA 1 a a� w, O A z rW V I.I.) 0.4 A Z < V Ow zw Iia z LLj V PERMIT SET DRAWN: A.P.,J.B. CHECKM P.A. DATE: 09 -25 -08 SCALEi AS NOTED SEAL UCEN5ff tt F' : W i r G Cti Sheet No. E0.00 I JOB 0 28003 I L I G H T I N G FIXTURE S C H E D U L E LAMPS FIXTURE TYPE MANUFACTURER & CATALOG No. MOUNTING ................................................ ......................... . ... .. . . .. .. .... ..... .... . ..... .....SEftVIGE......... .............. TOTAL REMARKS DESCRIPTION NO. TYPE WATTS VOLTS WATTS O LIGHTOLIER RECESSED 1 FLUORESCENT 17 17 277 52 1, 2 , 3 2X2 DIRECT INDIRECT QVS2GPFOS1 FT277B3 50W T175 DIMMING LIGHTOLIER FLUORESCENT 2X2 LENS OB RECESSED 2 50 277 59 1, 2 , 3 SPS2GRAVA26U277 -H1 FB32U61835 NO DIMMING LIGHTOLIER FLUORESCENT 2X13W DOWNLIGHT O RECESSED 2 13 277 28 1, 2 , 3 8052CLP- 6213HU CF13DD /835 NO DIMMING LIGHTOLIER FACES AND ARROWS AS X CEILING LED 3.6 277 3.6 SHOWN IN PLANS. TX2RCWN PROVIDE A BATTERY PACK. REMARKS 1. PROVIDE ADVANCE ELECTRONIC BALLASTS FOR ALL FLUORESCENT FIXTURES UNLESS OTHERWISE SPECIFIED 2 PROVIDE EMERGENCY SAVING BALLAST AND LAMPS 3. PROVIDE IN LINE FUSETO ALL FIXTURES PROVIDED WITH A BALLAST 4. PROVIDE PHILIPS T8 TO ALL LAMPS FOR ALL LINEAR FLUORESCENT FIXTURES, UNLESS OTHERWISE SPECIFIED 5. PROVIDE LIGHTOLER DIMMERS FOR CONTROL OF ALL FLUORESCENT LUMINAIRES WDIMMING BALLASTS. 6. MANUFACTURER AND CATALOG NUMBER LISTED ESTABLISHES THE MINIMUM LEVEL OF QUALITY ACCEPTABLE. ANY PROPOSED SUBSTITUTION MUST MEET OR EXCEED THIS LEVEL OF QUALITY, AS DETERMINED BY THE ENGINEER, AND MUST BE SUBMITTED FOR PRIOR APPROVAL A MINIMUM OF 14 DAYS BEFORE THE BID DUE DATE SUBMITTAL MUST BE MACE V lA A BIDDING GENERAL CONTRACTOR, AND FULLY OPERATIONAL SAMPLES MUST BE PROV IDEDAT THE ENGINEER'S REQUEST. o Revisions: 0 0 0 0 4 Z W � V of a ul m of ^ m g� C� G/1 0 o FA 1 a a� w, O A z rW V I.I.) 0.4 A Z < V Ow zw Iia z LLj V PERMIT SET DRAWN: A.P.,J.B. CHECKM P.A. DATE: 09 -25 -08 SCALEi AS NOTED SEAL UCEN5ff tt F' : W i r G Cti Sheet No. E0.00 I JOB 0 28003 I