08-1177-033SECTION A -A A INSULATION (IF REQUIRED BY SPECIFICATION RESILIENT TYPE PIPE I" THICK X 12' LONG SLEEVE NEOPRENE FOAM (RUBATEX OR ARMFLEX) PIPE RING 1" GREATER THAN PIPE O.D. Ed A INSULATION STEEL - SHIELD (SEE SPECS. FOR SHIELD CAGE) 16 GAUGE X 12" LONG GALVANIZED STEEL PIPE SHIELD I 1 A A I/l Crl r'I^M ADJUSTABLE TRAPEZE CHANNEL OR ANGLE TRAPEZE TYPE PIPE HANGER N.T.S. PIPE HANGER DETAILS N.T.S. "ONCRETE ANCHOR SELF DRILLING J.L. LISTED THRU 4" PIPE SIZE ROAD COUPLING, U.L. /F.M. GRINNELL 136 OR APPROVED EQUAL ALL THREAD ROAD RING METAL PIPE OR CONDUIT 3M FIRE CARRIER CP 25 C SCE OF WALL MAI I STAINLESS STEEL COVER SCREWED TO THREADED C.O. PLUG. TYPICAL CLEANOUT DETAIL N.T.S. nnIA IT METAL PIPE OR CONDUIT 3M FIRE CARRIER CP 25 CAUI FIRE RATED CONC. FLOOR SLAB NOTES: I- FLOOR OR WALL ASSEMBLY - MIN. 2 -1/2 IN. THICK REINFORCED LIGHTWEIGHT OR A NORMAL WEIGHT (100 -150 PCF) CONCRETE. WALL MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS. MAX DIAM OF OPENING IS 30 -7/8 IN, IA- STEEL FLOOR UNIT /FLOOR ASSEMBLY - AS AN ALTERNATE TO ITEM I, THE FLOOR ASSEMBLY MAY CONSIST OF A FLUTED STEEL FLOOR UNIT / CONCRETE FLOOR ASSEMBLY. THE FLOOR ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL FLOOR- CEILING DESIGN THE THE FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: I�. SECTION A -A A. CONCRETE - MIN 2-1/2 IN, THICK REINFORCED LIGHTWEIGHT ON NORMAL WEIGHT (100 -150 PCF) CONCRETE, AS MEASURED FROM THE TOP PLANE THE FLOOR UNITS. B. STEEL FLOOR AND FORM UNITS - COMPOSITE OR NON - COMPOSITE 1 -1/2" TO 3 IN. DEEP FLUTED GALV STEEL UNITS AS SPECIFIED IN THE INDIVIDUAL FLOOR - CEILING DESIGN. MAX DIAM OF OPENING IS 30 -7/8 IN. 2- THROUGH- PENETRANT- ONE METALLIC PIPE OR CONDUIT TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR 3M FIRE CARRIER SPACE BETWEEN PIPE OR CONDUIT AND PERIPHERY OF OPENING SHALL BE MIN 0 IN. CP 25 CAULK TO MAX 7/8 IN. PIPE OR CONDUIT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES OR CONDUITS MAY BE USED: UL APPROVED PIPING SAFING ASSEMBLIES EQUAL TO UL SYSTEM ttCAJ -1175 FOR INSULATED PIPE AND SYSTEM nC -AJ -1291 FOR NON INSULATED PIPE A. STEEL PIPE - NOM 30 IN. DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE. B. IRON PIPE - NOM 30 IN. DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE. C. COPPER PIPE - NOM 6 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. D. COPPER TUBING - NOM 6 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. E. CONDUIT - NOM 6 IN. DIAM (OR SMALLER) STEEL CONDUIT. F. CONDUIT - NOM 4 IN. DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING (EMT). 3- FILL, VOID, OR CAVITY MATERIAL - SEALANT - MIN 1/2 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH TOP SURFACE OF FLOOR OR WITH BOTH SURFACES OF WALL. -AT THE POINT CONTACT LOCATION BETWEEN PIPE AND CONCRETE, A MIN 114 IN. DIAM BEAD OF FILL MATERIAL SHALL BE APPLIED AT THE CONCRETE / PIPE INTERFACE ON THE TOP SURFACE OF FLOOR AND ON BOTH SURFACES OF WALL. PIPE PENETRATION FIRESTOP DETAIL N.T.S. PROJ. No. 18056 EB0000924 LOUIS J. AGUIRRE ASSOCIATES-. Rk � CONSULTING ENGINEERS 2600 DOUGLAS RD. SUITE 605 CORAL GABLE.a; 7LORIDA -, _ 331 4 TELEPHONE: csobj -444 -1679 FAX: =, -- E -MAIL ADDRESS: GRALMAILOLJAAPA.COM i Revisions: 0 0 0 A 0 V rn N a Z o F cme a a v O � N W V V) N cmd = an W F :� LLJ O n �uapi 1 A, �o p_" C� c� 1j •0 O m Q V f �U�I 1� O k � z LLJ a PERMIT SET DRA H CHECKED: P.A. DATE: 09-25-05 SCALE: AS NOTED SEAL tip' M�,C,H/�NIC'AL: T ?NESFO N;FA.NA P.E., LICEAISi`' ' 6 88- 1 ; Sheet No. P7.00 JOB f 28003 +. r �s