Loading...
08-1177-027PLUMBING GENERAL NOTES: I. ALL WORK SHALL COMPLY WITH ALL LOCAL LAWS AND REGULATIONS AND THE FLORIDA BUILDING CODE. ALL MATERIALS AND WORKMANSHIP SHALL BE OF THE HIGHEST QUALITY. 2. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY FOR THE COMPLETE INSTALLATION OF THE PLUMBING SYSTEMS, ALL IN ACCORDANCE WITH THESE CONSTRUCTION DOCUMENTS, ALL WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH THE FLORIDA BUILDING CODE 2004, ALL APPLICABLE STATE, COUNTY AND LOCAL ORDINANCES, AND ALL THE STANDARDS OF CONSTRUCTION ESTABLISHED BY THE EXISTING INSTALLATION. 3. THE CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE OF THE WORK AND BECOMING FAMILIAR WITH THE CONDITIONS OF THE WORK PRIOR TO SUBMITTING A BID. THE CONTRACTOR IS REQUIRED TO BECOME FAMILIAR WITH ALL THE CONTRACT DOCUMENTS PERTAINING TO THE PROPOSED WORK. THE SUBMISSION OF A BID SHALL BE SUFFICIENT TO ESTABLISH THAT THE CONTRACTOR HAS INVESTIGATED THE SITE OF THE WORK AND IS SATISFIED AS TO ALL REASONABLE CONDITIONS TO BE ENCOUNTERED, THE WORK TO BE PERFORMED AND THE MATERIALS TO BE PROVIDED IN THE COMPLETION OF THE PROJECT. 4. FAILURE OF BIDDERS TO MAKE REQUIRED VISITATIONS AND /OR INVESTIGATIONS TO INFORM THEMSELVES FULLY OF EXISTING CONDITIONS, AND TO INCLUDE IN THEIR PROPOSALS A SUM SUFFICIENT TO COVER ALL POSSIBLE FIELD CONDITIONS, WILL NOT IN ANY WAY ENTITLE THEM TO ANY EXTRA CHARGES OVER AND ABOVE THEIR ORIGINAL PROPOSALS. 5. IT IS THE INTENT OF THE PLANS AND GENERAL NOTES TO PROVIDE A COMPLETE AND OPERATING INSTALLATION INCLUDING ALL NECESSARY ITEMS REQUIRED, EVEN THOUGH ITEMS ARE NOT INDICATED ON THE DRAWINGS OR IN THE NOTES. ALL WORK CONSIDERED NECESSARY FOR THE COMPLETION OF THE WORK IN PROPER MANNER NOT SHOWN ON THE PLANS OR NOTES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IN WRITING PRIOR TO BIDS OTHERWISE WORK SHALL NOT BE ADDITIONALLY CHARGED AFTER BID IS AWARDED. 6. THE CONTRACTOR SHALL PAY ALL COSTS OF PERMIT, INSPECTIONS AND ALL OTHER COSTS INCIDENTAL TO THE COMPLETION AND TESTING OF THIS WORK. UPON FINAL ACCEPTANCE, A CERTIFICATE FROM THE LOCAL INSPECTION AUTHORITY SHALL BE FURNISHED TO THE OWNER, 7. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO ENGINEER FOR APPROVAL OF ALL EQUIPMENT, MATERIALS AND LAYOUTS PRIOR TO INSTALLATION. 8. CONTRACTOR SHALL GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE. 9. UPON COMPLETION, CONTRACTOR SHALL CLEAN ALL DUST AND DEBRIS IN AREAS WHERE WORK WAS CONDUCTED. 10. ALL WORK SHALL BE COORDINATED WITH ALL OTHER TRADES AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF EQUIPMENT. II. THE WORK THAT IS TO BE DONE UNDER THIS CONTRACT INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS AND EQUIPMENT REQUIRED FOR THE COMPLETION OF THE SYSTEMS SHOWN ON DRAWINGS. 12. THE DRAWINGS ARE GENERALLY DIAGRAMMATIC. THEY DO NOT SHOW EVERY BEND, OFFSET, ELBOW OR OTHER FITTINGS WHICH MAY BE REQUIRED FOR THE INSTALLATION IN THE SPACE ALLOCATED. 13. DRAWINGS ARE NOT TO BE SCALED. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE ARCHITECTURAL AND /OR SITE CONDITIONS SHALL GOVERN EXACT LOCATION OF PIPING AND EQUIPMENT TO BE INSTALLED. 14. ALL MATERIALS AND EQUIPMENTS SHALL BE NEW AND OF GOOD QUALITY OF RESPECTIVE KIND AND GRADE AND MUST BE FURNISHED SO AS TO PREVENT ANY DELAY IN THE PROGRESS OF THE WORK. ALL WORK THROUGHOUT SHALL BE PERFORMED IN A WORKMANLIKE MANNER BY SUFFICIENT NUMBER OF SKILLED WORKMEN. 15. FOR EXACT LOCATION OF ALL PLUMBING FIXTURES, SEE ARCHITECTURAL DRAWINGS. DO NOT ROUGH-IN ANY PLUMBING FIXTURE AND /OR EQUIPMENT WITHOUT AN APPROVED COPY OF THE CORRESPONDING SHOP DRAWINGS. 16. PROVIDE A CLEANOUT AT BASE OF EACH SOIL AND WASTE STACK, 17. CLEANOUTS SMALLER THAN 3 INCHES SHALL BE SO INSTALLED THAT THERE IS A CLEARANCE OF NOT LESS THAN 12 INCHES FOR THE PURPOSE OF PODDING. CLEANOUTS ON 3 INCH OR LARGER PIPES SHALL BE SO LOCATED THAT THERE IS A CLEARENCE OF NOT LESS THAN 18 INCHES FOR THE PURPOSE OF PODDING. 18. PROVIDE 24 "X24 "X4" CONCRETE PAD FOR ALL CLEANOUTS LOCATED IN GRASS OR EARTH AREAS. 19. ALL FLOOR DRAINS AND SHOWER DRAINS WITH TAP FOR TRAP SEAL. 20. FLOOR DRAIN RESEALS SHALL BE FROM A WATER CLOSET FLUSH VALVE TAILPIECE UNLESS OTHERWISE NOTED. FLUSH VALVE WITH TRAP PRIMER ASSEMBLY. 21. ALL HORIZONTAL PIPING 3' AND LARGER SHALL BE SLOPED AT 1 /8" PER FOOT. ALL HORIZONTAL PIPING 21/2" AND SMALLER SHALL BE SLOPED AT 1/4" PER FOOT. 22. ACCESS PANELS LARGE ENOUGH TO REPLACE OR REPAIR UTILIZING NORMAL TOOLS SHALL BE PROVIDED FOR ANY VALVE LOCATED WITHIN A CHASE OR CONCEALED IN CEILING OR WALLS. 23. PROVIDE SHUT -OFF VALVES AND UNIONS TO ALL FIXTURES AND EQUIPMENT, ETC., 12EOUI12ING WATER SUPPLY. PROVIDE DIELECTRIC COUPLINGS AS REQUIRED. 24. ALL PLUMBING FIXTURES SHALL BE PROVIDED WITH ALL NECESSARY ACCESSORIES SUCH AS STOP VALVES, "P" TRAPS, SUPPORTS, P E T VALVES, ETC. AS REQUIRED. ALL EXPOSED PIPING AT FIXTURES AND EQUIPMENT SHALL BE CHROME PLATED BRASS PIPE OR TUBE. PROVIDE WATER HAMMER ARRESTOR AT EACH GROUP OF FIXTURES. 25. PROVIDE SLEEVES FOR ALL PIPING THROUGH WALLS AND FLOOR SLABS. SLEEVES SHALL BE EXTENDED 2 INCHES BEYOND EACH FACE, SLEEVES FOR ANY PIPES SHALL BE OF THE SAME MATERIAL AS THE PIPING. ANNULAR SPACE BETWEEN PIPING AND SLEEVES SHALL BE FILLED WITH FIRE STOP PRODUCTS. SEE DETAIL. 26. PROVIDE PITCH PANS AND LEADS FLASHING FOR ALL SANITARY SYSTEM VENTS. PLUMBING SPECIFICATIONS: HANGERS AND SUPPORTS A. PROVIDE ADJUSTABLE HANGERS, INSERTS, BRACKETS, ROLLS, TRAPEZE, CLAMPS AND SUPPLEMENTARY STEEL AS REQUIRED FOR PROPER SUPPORT OF PIPE LINES. B. HANGERS SHALL ALLOW FOR EXPANSION AND CONTRACTION OF PIPE LINES AND OF ADEQUATE SIZE TO PERMIT COVERING TO RUN CONTINUOUSLY THROUGH HANGERS. C. COORDINATE LOCATION OF HANGERS WITH OTHER TRADES. D. HANGERS SHALL BE PLACED WITHIN 18 INCHES OF HUB OR JOINT FOR HORIZONTAL CAST IRON PIPE. HUBLESS JOINTS MUST BE SUPPORTED AT EVERY OTHER JOINT EXCEPT THAT WHEN THE LENGTH BETWEEN SUPPORTS EXCEEDS FOUR FEET THEY SHALL BE PROVIDED AT EACH JOINT. E. HANGERS SHALL BE PLACED AT EACH CHANGE OF DIRECTION, WITHIN ONE FOOT OF VALVES AND OTHER APPURTENANCES INSTALLED IN HORIZONTAL PIPING AND NOT MORE THAN THREE FEET FROM END OF EACH BRANCH RUNOUT. F. HANGERS SHALL BE ADJUSTABLE CLEVIS TYPE WITH CONTINUOUS THREADED RODS. SANITARY, GREASE, WASTE AND VENT PIPING A. ALL HORIZONTAL BRANCHES, SEWER AND DRAIN LINES SHALL BE SLOPED A MINIMUM OF 1/8 INCH PER FOOT UNLESS OTHERWISE INDICATED ON PLANS. B. EVERY FIXTURE CONNECTED TO THE DRAINAGE SYSTEM SHALL BE EQUIPPED WITH A WATER SEAL TRAP. C. VENT STACKS SHALL NOT PASS THROUGH ROOF AT VALLEYS, ROOF CRICKETS, IN FRONT OF WINDOWS OR WITHIN 6' -0" OF ROOF EDGE. D. MATERIALS SHALL BE AS FOLLOWS: 1) DRAINAGE AND VENT PIPING (BELOW GRADE) SHALL BE HUB AND SPIGOT SERVICE WEIGHT CAST IRON WITH GASKETED PUSH -ON JOINTS. 2) DRAINAGE AND VENT PIPING (ABOVE GRADE): SHALL BE HUBLESS SERVICE WEIGHT CAST IRON WITH NEOPRENE GASKETS AND STAINLESS STEEL BAND JOINTS. DOMESTIC COLD AND HOT WATER PIPING A. PROVIDE AIR CHAMBER 18" HIGH, NEXT SIZE LARGER THAN PIPE SERVING THE FIXTURE. B. PROVIDE DIELECTRIC UNIONS WHERE DISSIMILAR METALS ARE JOINED. C. ESCUTCHEONS SHALL BE CHROME PLATED BRASS WITH LOCKING SCREWS WHERE PIPES PASS THROUGH FINISHED WALLS. D. EACH NOSE BIBB SHALL BE FURNISHED WITH A VACUUM BREAKER AND SHUT -OFF VALVE. E. PROVIDE PIPING AS FOLLOWS: D WATER PIPING (BELOW GRADE): SHALL BE COPPER TYPE 'K" ASTM B-88 WITH WROUGHT COPPER FITTINGS AND 95 -5 SOLDERED JOINTS. PAINT WITH BITUMASTIC WHEN INSTALLED IN GRADE. 2) WATER PIPING (ABOVE GRADE): SHALL BE COPPER TYPE "L" ASTM B-88 WITH WROUGHT COPPER FITTINGS AND 95 -5 SOLDERED JOINTS. COPPER TYPE 'K" ASTM B -88 UNDER GROUND. 3) PRESSURE AND TEMPERATURE RELIEF LINES: SHALL BE TYPE "M" COPPER WITH WROUGHT COPPER FITTINGS AND 50 -50 SOLDERED JOINTS. F. ALL EXPOSED PIPING WITHIN TOILET ROOMS SHALL BE CHROME PLATED. VALVES A. PROVIDE CONTROL VALVES WHERE NOTED ON PLANS, AND AS REQUIRED FOR COMPLETE REGULATION OR CONTROL OF ALL SYSTEM MAINS, BRANCHES TO GROUP OF FIXTURES, AND TO EACH PIECE OF EQUIPMENT. B. PROVIDE ACCESS PANELS AS REQUIRED TO VALVES, OR GROUP OF VALVES, WHERE CONCEALED AND FOR PROPER MAINTENANCE AND OPERATION OF SYSTEM. C. GATE VALVES: 1) 2 -1/2 INCHES AND SMALLER SHALL BE BRONZE BODY, SCREWED BONNET, NON- RISING STEM, SOLID WEDGE, CLASS 125, 200 PSI NON -SHOCK WATER, THREADED END WATTS WGV- SERIES, SOLDERED END WATTS WGVS- SERIES. TESTING A. COMPLETE WATER PIPING SYSTEM SHALL BE PRESSURE TESTED BY CAPPING OR PLUGGING OPENINGS, FILLING SYSTEM WITH WATER AND APPLYING HYDROSTATIC PRESSURE OF 125 PSI FOR PERIOD OF NOT LESS THAN 2 HOURS. B. SOIL, WASTE AND VENT PIPING SHALL BE TESTED BY CAPPING THE ENDS OF THE SYSTEM AND ALL LINES FILLED WITH WATER TO HIGHEST POINT AND ALLOW TO STAND UNTIL INSPECTION IS MADE AND WATER LEVEL REMAINS CONSTANT. INSULATION A. INSULATION SHALL RUN CONTINUOUS THROUGH WALLS, FLOORS AND CEILINGS. B. WHERE INSULATION PASSES THROUGH HANGERS IT SHALL BE PROVIDED WITH A PROTECTION SHIELD, 180 DEGREE ARC GALVANIZED SHEET METAL COVERING 12 INCHES LONG. C. ALL A/C CONDENSATE DRAIN LINES ABOVE GRADE SHALL BE INSULATED WITH 1/2" ARMAFLEX PIPE INSULATION. SEAL ALL SEAMS WITH INSULATION MANUFACTURER'S SOLVENT. NO TAPES ARE ALLOWED. D. GLASS CLOTH JACKET: FACTORY SIZED WHITE, STANDARD WEIGHT, WITH 1 -1/2 INCH MINIMUM LONGITUDINAL PRESSURE SEALING LAP, AND SEAL STRIPS FOR BUTT JOINTS. E. VAPOR BARRIER JACKET: FLAME RESISTANT GLASS FIBER ADHERED TO OUTSIDE OF A I -MIL ALUMINUM FOIL SHEET WITH LONGITUDINAL PRESSURE SEALING LAP AND SEAL STRIPS FOR BUTT JOINTS. END JOINT CEMENT PERM RATING NOT TO EXCEED .05. F. DOMESTIC HOT WATER SUPPLY PIPING: 1/2 INCH THICK GLASS FIBER MOLDED INSULATION WITH PRE -SIZED FACTORY APPLIED FIRE RATED JACKET OF GLASS CLOTH WITH LONGITUDINAL LAP AND BUTT JOINT STRIPS WITH SELF - SEALING ADHESIVE. G. CONDENSATE DRAINING, DRINKING FOUNTAIN AND ELECTRIC WATER COOLER DRAINS; ELASTOMERIC (FOAM PLASTIC) THERMAL INSULATION 1/2 INCH THICK WITH BUILT -IN VAPOR BARRIER RATED SELF- EXTINGUISHING. INSULATION SHALL HAVE A MAXIMUM THERMAL CONDUCTIVITY OF 0.26K FACTOR AT 70 DEGREES F. MEAN TEMPERATURE, DENSITY OF 5 -6 POUNDS PER CUBIC FOOT AND A WATER VAPOR TRANSMISSION OF 0.1 PERMS. STERILIZATION A. AFTER WATER PIPING HAS BEEN THOROUGHLY FLUSHED OUT, STERILIZE THE LINES BY INTRODUCING INTO THEM A SOLUTION OF CALCIUM HYPOCHLORITE OR CHLORIDE OF LIME. OPEN AND CLOSE ALL VALVES WHILE SYSTEM IS BEING CHLORINATED. AFTER THE STERILIZING AGENT HAS BEEN APPLIED FOR 24 HOURS, TEST FOR RESIDUAL CHLORINE AT THE ENDS OF THE LINES. IF LESS THAN 5 PARTS PER MILLION IS INDICATED, REPEAT THE PROCESS. WHEN THE TESTS SHOW AT LEAST 5 PARTS PER MILLION OF RESIDUAL CHLORINE, FLUSH OUT THE SYSTEM UNTIL ALL TRACES OF THE CHEMICAL USED ARE REMOVED. MAKE NECESSARY CONNECTIONS TO STERILIZE PIPING. PLUMBING FIXTURE CONNECTION SCHEDULE MARK DESCRIPTION WASTE CW HW REMARKS L -I LAVATORY 1 1/2" 1/2" 1/2" A. AMERICAN STANDARD MODEL NO.0356.421 LUCERNE WALL HUNG LAVATORY 20 -1/2* X COUPLING OR UNION (ADA) SHUT -OFF VALVE (GATE VALVE) I 18 -1/4'. WALL CLEANOUT EXISTING CHECK VALVE -C+ EXISTING HOSE BIBB B. FAUCET: SLOAN MODEL NO.EAF -100 -P -ISM WITH 6 V.D.C. PLUG -IN TRANSFORMER. EXISTING BALL VALVE C CAP SENSOR C. SUPPLY PIPE: 3/8" RIGID RISER WITH LOOSE KEY CONTROL BY MCGUIRE. ABOVE FINISHED FLOOR LEVEL DN DOWN EXIST. EXISTING D. P -TRAP ADJUSTABLE OFFSET WITH TUBING DRAIN TO WALL, CLEANOUT PLUG AND SOIL STACK VIV VALVE IN VERTICAL VTR VENT THRU ROOF WALL ESCUTCHEON BY MCGUIRE. WASTE STACK E. GRID DRAIN: PERFORATED CHROME PLATED, 1 -1/4' OFFSET TAILPIECE BY MCGUIRE. F. CARRIER: FLOOR MOUNTED CARRIER ARMS, JOSAM 17100 OR ACCEPTED EQUIVALENT. G. HANDI LAV - GUARD INSULATION KIT 102/105 - WHITE BY TRUEBRO WC -1 WATER CLOSET 4' 1' - A. AMERICAN STANDARD MODEL NO.2257.103 AF WALL EL 1.6 GPF. ELONGATED BOWL. (ADA) B. FLUSH VALVE SLOAN MODEL NO.111 ES-S SENSOR AND 12 OVAC /24 VAC 50 VA. TRANSFORMER WITH OLSONITE n95 OPEN FRONT SEAT LESS COVER. C. CARRIER: JOSAM n12000 SERIES - CHASE SAVER II SK -1 SINGLE COMPARTMENT SINK 11/2" 1/2" 1/2" A. ELKAY MODEL NO.LR -1517, THREE FAUCET POLES WITH HEAVY DUTY SOUND GUARD UNDERCOATING. B. FAUCET: CHICAGO MODEL NO.786 -GN2B- 317 -E4. C. SUPPLY PIPE: FLEXIBLE RISERS WITH LOOSE KEY CONTROL BY MCGUIRE. D. P -TRAP ADJUSTABLE TRAP WITH TUBING DRAIN TO WALL, CLEANOUT PLUG AND WALL ESCUTCHEON BY MCGUIRE. E. GRID DRAIN: ELKAY MODEL NO. LK35. SK -2 SINGLE COMPARTMENT SINK 1 1/2' 1/2" 1/2" A. ELKAY MODEL NO.LR -1919, THREE FAUCET HOLES WITH HEAVY DUTY SOUND GUARD UNDERCOATING. B. FAUCET: CHICAGO MODEL NO.786 -GN2B- 317 -E4. C. SUPPLY PIPE: FLEXIBLE RISERS WITH LOOSE KEY CONTROL BY MCGUIRE. D. P -TRAP ADJUSTABLE TRAP WITH TUBING DRAIN TO WALL, CLEANOUT PLUG AND WALL ESCUTCHEON BY MCGUIRE. E. GRID DRAIN: ELKAY MODEL NO. LK35. REF ICE MAKER BOX - 1/2" - A. WATER TITE CODE a 88080 ICE MAKER BOX, COLD WATER CONNECTION W/ INTEGRAL WATER HAMMER ARRESTORS PLUMBING DRAIN SCHEDULE MARK DESCRIPTION WASTE REMARKS FD-I FLOOR DRAIN 3" POLISHED NICKEL BRONZE TOP, WITH TRAP PRIMER. NEW HOT WATER PIPE POLISHED NICKEL NEW HOT WATER RETURN PIPE J.R. SMITH MODEL u 2005-8. COUPLING OR UNION BRONZE TOP SHUT -OFF VALVE (GATE VALVE) I System No. C -AJ -1080 F- RATING - 3 NR T- RATING - 0 NR L RATING AT AMBIENT - LESS THAN I CFM /SQ FT L RATING AT 400 F - LESS THAN I CFM /SQ FT F- A L A Section A -A I. FLOOR OR WALL ASSEMBLY - MIN 4 -1/2 IN. THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100 -150 PCF) CONCRETE. WALL MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS *. MAX DIAM OF OPENING IS 32 IN. SEE CONCRETE BLOCK (CAZT) CATEGORY IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF MANUFACTURERS. 2. THROUGH PENETRANTS - ONE METALLIC PIPE, CONDUIT OR TUBING TO BE CENTERED WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE SHALL RANGE FROM MIN 0 IN. (POINT CONTACT) TO MAX 2 IN. PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED: A. STEEL PIPE - NOM 30 IN. DIAM (OR SMALLER) SCHEDULE 5 (OR HEAVIER) STEEL PIPE. B. IRON PIPE - NOM 30 IN. DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE. C. CONDUIT - NOM 4 IN. DIAM (OR SMALLER) ELECTRICAL METALLIC TUBING OR NOM 6 IN. DIAM (OR SMALLER) RIGID GALV STEEL CONDUIT. D. COPPER TUBING - NOM 6 IN. DIAM (OR SMALLER) TYPE M (OR HEAVIER) COPPER TUBING. E. COPPER PIPE - NOM 6 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. 3. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: A. PACKING MATERIAL - (OPTIONAL, NOT SHOWN) - MINERAL WOOL BATT INSULATION, POLYETHYLENE BACKER ROD OR GLASS FIBER BATT INSULATION FRICTION FITTED INTO ANNULAR SPACE. PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF FLOOR OR BOTH SURFACES OF WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL. B. FILL, VOID OR CAVITY MATERIAL* - CAULK - MIN 1/2 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH TOP SURFACE OF FLOOR OR WITH BOTH SURFACES OF WALL. AT POINT CONTACT LOCATION, APPLY MIN 114 IN. DIAM BEAD OF SEALANT AT THE PIPE /CONCRETE INTERFACE ON THE TOP SURFACE OF THE FLOOR OR BOTH SURFACES OF WALL. SPECIFIED TECHNOLOGIES INC - SPECSEAL 100, 101, 102, 105, 120 OR 129 SEALANT *BEARING THE UL CLASSIFICATION MARK PROJ. No. 18056 EB0000924^ LOUIS J. AGIRRE- 4- ASSOCATE1,; R.A. ; CONSULTING ENGINEERS 2600 DOUGLAS RD. SUITE 605 CORAL GABLES,'rWRIDA TELEPHONE: 2k5)-,444-1&f9 FAX: '(305) 448,' . - E -MAIL ADDRESS: GRALMAIL@LJAAPA.COM PLUMBING SYMBOL LEGEND SYMBOL DESCRIPTION CHECKED% NEW SANITARY PIPE DATE: NEW VENT LINE SCALE: NEW COLD WATERLINE NEW HOT WATER PIPE - - - NEW HOT WATER RETURN PIPE F COUPLING OR UNION SHUT -OFF VALVE (GATE VALVE) I WCO�iI WCOo -II WALL CLEANOUT EXISTING CHECK VALVE -C+ EXISTING HOSE BIBB ( EXISTING BALL VALVE C CAP SENSOR AFF ABOVE FINISHED FLOOR LEVEL DN DOWN EXIST. EXISTING SS SOIL STACK VIV VALVE IN VERTICAL VTR VENT THRU ROOF WS WASTE STACK System No. W -L -1054 F Ratings -1 and 2 Hr (See Items 1 and 3) T Rating - 0 Hr L Rating At Ambient - Less Than 1 CFM /Sq Ft L Rating At 400 F - 4 CFM /Sq Ft SECTION A -,4 1. Wall Assembly -- The 1 or 2 hr fire -rated gypsum wallboard /stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory. 2. Through- Penetrants -- One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the firestop system. The annular space shall be min 0 in. to max 2 -1/4 in. Pipe may be installed with continuous point contact. Pipe, conduit or tubing may be installed at an angle not greater than 45 degrees from perpendicular. Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used: A. Steel Pipe -- Nom 30 in diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe - Nom 30 in. diam (or smaller) cast or ductile iron pipe. C. Conduit - Nom 4 in diam (or smaller) steel electrical metallic tubing or 6 in. diam steel conduit. D. Copper Tubing - Nom 6 in. diam (or smaller) Type L (or heavier) copper tubing. E. Copper Pipe - Nom 6 in. diam (or smaller) regular (or heavier) copper pipe. 3. Fill, Void or Cavity Material* -- Sealant - Min 5/8 in. thickness of fill material applied within the annulus, flush with both surfaces of wall. At the point or continuous contact locations between pipe and wall, a min 1/2 in. diam bead of fill material shall be applied at the pipe wall interface on both surfaces of wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- FS -One Sealant *Bearing the UL Classification Mark ® w-/ Fj�o u RRESTOP SYSTEMS C ® L U S Revisions: 0 Z__\ 0 2L 0 V rn N L a a cvC 4 � cn 4 V O WN IP_ cZ LAJ V N a Q 0 LLj 1­00 O �� N .. h own $ 1-4 PMM •ice O n� O� Q� V g J a6q a Z ,L N V H .j _z LLj � a IW Z W V PERMIT SET DRAW% A.P.,J.B. CHECKED% P.A. DATE: OcJ -25 -08 SCALE: A5 NOTED SEAL MECHANICAL- .2 WNESTOyS� TrgNA.P.E. LICEN ; Sheet No. P0.00 IJOB # 20003 E