08-1177-022HVAC GENERAL NOTES 1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY FOR THE INSTALLATION OF HVAC SYSTEM IN ACCORDANCE WITH THESE DRAWINGS. FLORIDA BUILDING CODE 2004 ANS /ASHRAE 15 -1994 NFPA PAMPHLETS 90A, 9OB -91 -2002 SMACNA -1995 ASH RAE -2001 OSHA -2005 2. THE WORK INCLUDES PROVIDING THE HVAC SYSTEMS, INCLUDING DUCTWORK, DIFFUSERS AND GRILLES, INSULATION, CONTROLS AND EQUIPMENT NECESSARY FOR A COMPLETE FUNCTIONING SYSTEM. HVAC SYSTEM INCLUDES BUT IS NOT LIMITED TO THE FOLLOWING: SUPPLY, RETURN AND EXHAUST DUCTWORK SYSTEMS WITH GRILLES, DIFFUSERS FILTERS AND DAMPERS. 3. TEMPERATURE CONTROL SYSTEM INCLUDING LOW VOLTAGE WIRING AND CONDUIT, TRANSDUCERS, ACTUATORS, CONTROLLER. 4. WARRANTY: PROVIDE LABOR AND MATERIALS TO REPAIR OR REPLACE DEFECTIVE PARTS AND MATERIALS AS REQUIRED FOR ONE YEAR AFTER SUBSTANTIAL COMPLETION OR OWNER ACCEPTANCE OF THE COMPLETED PROJECT. 5. DRAWINGS FOR HVAC WORK ARE DIAGRAMMATIC, SHOWING THE GENERAL LOCATION, TYPE, LAYOUT AND EQUIPMENT REQUIRED. THE DRAWINGS SHALL NOT BE SCALED FOR EXACT MEASUREMENTS. REFER TO MANUFACTURER'S STANDARD INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTIONS AND INSTALLATION REQUIREMENTS AS REQUIRED. FURNISH AND INSTALL ALL DUCTWORK, CONNECTIONS, ACCESSORIES, OFFSETS AND MATERIALS NECESSARY TO FACILITATE THE SYSTEM FUNCTIONING AS INDICATED BY THE DESIGN AND THE EQUIPMENT INDICATED. 6. CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL TRADES, ESPECIALLY WITH THE LOCATION OF STRUCTURAL MEMBERS, PIPING, SPRINKLERS, CONDUITS AND LIGHTING OUTLETS AND /OR FIXTURES. 7. ALL MATERIAL AND EQUIPMENTS SHALL BE NEW OF U.S. MANUFACTURER AND OF GOOD QUALITY OF RESPECTIVE KIND AND GRADE, AND MUST BE FURNISHED SO AS TO PREVENT ANY DELAY IN THE PROGRESS OF THE WORK. ALL WORK THROUGHOUT SHALL BE PERFORMED IN A WORKMANLIKE MANNER BY SUFFICIENT NUMBER OF SKILLED PERSONNEL. 8. FLEX DUCT: PROVIDE FACTORY ASSEMBLED CLASS 1 AIR DUCT (UL 181) WITH 1 -1/2" THICK 1 PCF FIBERGLASS INSULATION R -6 AND REINFORCED OUTER PROTECTIVE COVERNAPOR BARRIER. FLEX DUCT SHALL MEET NFPA 90A WITH FLAME SPREAD UNDER 25, SMOKE DEVELOPED UNDER 50, AND SHALL BE RATED FOR 2" W.G. PRESSURE AND 0 TO 250 DEGREES FAHRENHEIT. PROVIDE METAL ADJUSTABLE CLAMPING DEVICES, SCREW OPERATED. USE TWIST -LOCK CONICAL TAP COLLARS AT CONNECTIONS INTO SHEET METAL DUCTWORK. FLEXIBLE DUCTWORK MAYBE USED FOR BRANCHES TO DIFFUSERS AS INDICATED ON DRAWINGS. DO NOT EXCEED EIGHT (8) FEET IN LENGTH FOR ANY FLEX DUCT. 9. BALANCING DAMPERS: FABRICATED OF SAME MATERIAL AS DUCT, TWO METAL GAUGES HEAVIER THAN DUCT. MOUNT ON 3/8" SQUARE ROD WITH SAW SLOT POSITION INDICATOR. PIVOT AND BEARING, LOCKING POSITION REGULATOR. 10. ALL EQUIPMENT AND MATERIALS SHALL BE NEW, FREE FROM DEFECTS AND WITH MANUFACTURER'S WARRANTY. 11. PROVIDE DOUBLE THICKNESS TURNING VANES AT ELBOWS AND EXTRACTOR DAMPERS AT ALL DUCT BRANCHES AND TAKE -OFFS. 12. ALL EXHAUST DUCTWORK SHALL BE OF GALVANIZED SHEET METAL FABRICATED IN ACCORDANCE WITH SMACNA STANDARD FOR PRESSURE CLASS ACCORDING TO EACH SYSTEM. EXHAUST AIR DUCTWORK SHALL BE UNINSULATED. 13. FLEXIBLE CONNECTOR: WHERE REQUIRED PROVIDE U.L. LABELED NEOPRENE COATED FIBERGLASS FABRIC DUCT CONNECTORS. 14. CONTRACTOR SHALL BE RESPONSIBLE TO TEST & BALANCE THE HVAC SYSTEMS AS PER ASSOCIATED AIR BALANCE COUNCIL STANDARDS. 15. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO ENGINEER FOR APPROVAL OF ALL EQUIPMENT, MATERIALS AND LAYOUTS PRIOR TO INSTALLATION. 16. CONTRACTOR SHALL PRINT UP INSTRUCTIONS FOR OWNER'S OPERATION OF SYSTEMS. 17. THE CONTRACTOR SHALL PAY ALL INSPECTION FEES. ALL COSTS OF PERMITS AND ALL OTHER COSTS INCIDENTAL TO THE COMPLETION AND TESTING OF THIS WORK UPON FINAL ACCEPTANCE A CERTIFICATE FROM THE LOCAL INSPECTION AUTHORITY SHALL BE FURNISHED TO THE OWNER. 18. THE CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH THE LOCATION OF EXISTING EQUIPMENT, DUCTWORK, PIPING, CONDUITS, ETC., AND /OR ANY CONDITION THAT MAY AFFECT HIS WORK. 19. ALL AIR CONDITIONING DUCTWORK SHALL BE CODE GAGE GALVANIZED SHEET METAL INSULATED WITH 2 INCH THICK AND 1.0 PCF GLASS FIBER FLEXIBLE BLANKET INSULATION WITH ALUMINUM FOIL REINFORCED WITH GLASS FIBER FASING (FSKL) JOHN - MANVILLE MICROLITE (R -6 INSTALLED) OR APPROVED EQUIVALENT, DUCT SIZES SHOWN ARE NET FREE AREA. PROVIDE DOUBLE THICKNESS TURNING VANES AND EXTRACTORS AT ALL ELBOWS AND TAKE -OFFS. 20. ALL CONCEALED SUPPLY AIR DUCTS SHALL BE EXTERNALLY INSULATED WITH DUCT WRAP AS INDICATED IN GENERAL NOTES. 21. CONSTRUCTION FILTER: PROVIDE TWO SETS OF TEMPORARY 2 INCH THICK FIBERGLASS THROW AWAY FILTERS DURING CONSTRUCTION AND START UP. CONSTRUCTION FILTERS TO BE 35% EFFICIENT. CONSTRUCTION FILTERS PROVIDED FOR ALL FILTER APPLICATION. REPLACE FILTER REGULARLY BUT NOT TO EXCEED 7 DAYS DURING CONSTRUCTION. FINAL FILTERS: SHALL CONSIST OF A SINGLE 2 INCH THICK, DISPOSABLE, PLEATED PARTICULATE FILTER, ASHRAE 52.1 -92 RATED AT 40- 45% PERCENT ATMOSPHERIC DUST SPOT EFFICIENY (ADS), LOCATED IN FILTER BOX OF EACH COIL. 22. RETURN AIR DUCTS LOCATED ABOVE UNCONDITIONED SPACES SHALL BE INSULATED THE SAME AS THE SUPPLY AIR DUCTS. 23. DUCT FINISHES AND SEALERS SHALL HAVE A SMOKE DEVELOPED RATING OF LESS THAN 50 AND A FLAME SPREAD OF 25 OR LESS. 24. DURING CONSTRUCTION, ALL SUPPLY AND RETURN DUCTWORK OPENINGS SHALL BE FITTED WITH BLANKET TYPE, DISPOSABLE 1" THICK SYNTHETIC MEDIA IN ORDER TO PREVENT CONSTRUCTION DEBRIS FROM ENTERING AND ACCUMULATING INSIDE THE DUCT SURFACES. UPON COMPLETION, CONTRACTOR SHALL CLEAN ALL DUST AND DEBRIS IN AREAS WHERE WORK WAS CONDUCTED. AIR DISTRIBUTION LEGEND DUCT: FIRST FIGURE IS SIDE SHOWN ® � DUCT MTD. SMOKE DETECTOR W /REMOTE is TEST SWITCH (PROVIDE ACCESS DOOR) ❑ AD SD FC nn nn AA^^ nn U.C. ' DUCT SECTION SUPPLY E RETURN FLEXIBLE DUCT, FLEXIBLE CONNECTION (FC) ALL ELBOW MUST BE PROVIDED WITH TURNING VANES WHETHER UNDERCUT DOOR OR SHOWN ON DWGS. (SEE SPECS) STRAP t`T -E:7 TYP. 450 TAP -OFF WITH VOLUME DAMPER THERMOSTAT VOLUME DAMPER MOTORIZED DAMPER ❑M SPLITTE12 DAMPER VARIABLE VOLUME BOX WITH ELECTRIC HEATER 10 ga. 1" X 22 ga. 12 ga. VAV FIRE DAMPER A.D. ❑ 1 EQUIPMENT OR DUCTS (0.135) HP (0.135) HR (MUST USE ACCES DOOR) IN. EXISTING TO REMAIN P/2 = 72" 1" X 18 ga. 3/8" 1" X20 ga. POINT OF CONNECTION 1" X 22 ga. 1/4" 1" X 22 ga. BETWEEN NEW AND EXISTING P/2 = 96" 1" X 16 ga. 3/8" WORK 3/8" 1" X 20 ga. 3/8" NOTES I. 45 °TAP -OFFS, SPLITTERS AT EACH TAP -OFF AND TEE, AND ACCESS DOORS SHALL BEE USED WHERE REQUIRED, WHETHER OR NOT INDICATED IN THE DRAWINGS. 2. IN AREAS WHERE NON- REMOVABLE CIELINGS ARE USED, PROVIDE 45 TAP -OFFS OF THE FIXED TYPE, WITH WIDTH PROPORTION TO BRANCH CFM. 3. REMOTE LIGHT AND TEST SWITCH NEXT TO AHU STARTER TYPE OF DIFFUSER A 1W----DIRECTION OF FLOW 6x6-- f 1 cJ 0 SIZE OF DIFFUSER AMOUNT OF CFM AIR OUTLET TAG N.T.S. I OUTSIDE AIR CALCULATIONS: I OFF AREA 2,732 S.F. I. NUMBER OF PEOPLE (FBMC 2004 TB- 403.3) 2,732 S.F. X 7PEOPLE - 19.1 1,000 2. MINIMUM OUTSIDE AIR REQUIRED. 20 PEOPLE X 20 C.F.M. = 400 C.F.M. PERSON 3. TOTAL OUTSIDE AIR PROVIDED = 400 C.F.M. 4. TOTAL EXHAUST AIR: 80 C.F.M. RECTANGULAR DUCT HANGERS MINIMUM SIZE MAXIMUM HALF OF PAIR AT 10 FT. SPACING PAIR AT 8 FT. SPACING PAIR AT 5 FT. SPACING PAIR AT 4 FT. SPACING DUCT PER IMEFER STRAP WIRFJROD STRAP WIRE/ROD STRAP WIRE/ROD STRAP WIRE/ROD P/2 = 30" 1" X 22 ga. 10 ga. 1" X 22 ga. 10 ga. 1" X 22 ga. 12 ga. 1" X 22 ga. 12 ga. FEET PER MINUTE FPS (0.135) HP (0.135) HR (0.106) IN. (0.106) P/2 = 72" 1" X 18 ga. 3/8" 1" X20 ga. 1/4" 1" X 22 ga. 1/4" 1" X 22 ga. 1/4" P/2 = 96" 1" X 16 ga. 3/8" 1" X 18 ga 3/8" 1" X 20 ga. 3/8" 1" X 22 ga. 1/4" P/2 =120" 1 1/2" X 16 ga. 112" 1" X 16 ga. 3/8" 1" X 18 ga. 3/8" 1" X 20 ga. 1/4" P/2 = 168" 1 1/2" X 16 ga. 112" 1 1/2" X 16 ga. 1/2" 1" X 16 ga. 3/8" 1" X 18 ga. 3/8" P/2 = 192" NOT GIVEN 1/2" 1 1/2" X 16 ga. 1/2" 1" X 16 ga. 3/8" 1 1/2" X 16 ga 3/8" P/2 = 193" UP SPECIAL ANALYSIS REQUIRED WHEN STRAPS ARE LAP JOINED USE 21 ", 22" 16 ga. D-20 SINGLE HANGER MAXIMUM ALLOWABLE LOAD THESE MINIMUM FASTENERS C-26 C-26 C-26 STRAP WIRE OR ROD (DA.) 1" X 18,20,22 ga. - TWO #10 OR ONE 1/4" BOLT 1" X 22 ga. - 260 lbs. 0.106" - 80 lbs. 1" X 16 ga. - TWO 1/4" DA. BOLT 1" X 20 ga. - 320 lbs. 0.135" - 120 Ibs. 1 1/2" X 16 ga. - TWO 3/8" DA. BOLT 1" X 18 ga. - 420 lbs. 0.162" - 160 lbs. PLACE FASTENERS IN SERIES, NOT SIDE BY SIDE 1" X 16 ga. - 700 lbs. 114" - 260 lbs. 624 622 622 620 G•18 K18 1-16G 1-16G 1 1/2" X 16 ga. - 700 lbs. 318" - 680 lbs. C-26 C•26 1/2" - 1250 lbs. 27 ", 28" D-26 5/8" - 2000 lbs. G26 29 ", 30" 3/4" - 3000 lbs. NOTES: 1 DIMENSIONS OTHER THAN GAGES ARE IN INCHES. 2. TABLE ALLOWS FOR DUCT WEIGHT, 1 lblft2 INSULATION WEIGHT AND NORMAL REINFORCEMENT AND TRAPEZE WEIGHT, BUT NO EXTERNAL LOADS. 3. STRAPS ARE GAL VAN IZ ED STEEL; OTHER MATER lA LS A RE UNCOATED STEEL. 4. ALLOWABLE LOADS FOR P/2 ASSUME THAT DUCTS ARE 16 GA. MAXIMUM, EXCEPT THAT WHEN MAXIMUM DUCT DIMENSION (W) IS OVER 60" THAN P/2 MAXIMUM IS 1.25 in. 5.12, 10, 8 ga. WIRE IS STEEL OF BLACK ANNEALED, BRIGHT BASIC, OR GALVANIZED TYPE. AIR CONDITIONING LEGEND SYMBOL DESCRIPTION AHU AIR HANDLER UNIT BD BACKD12AFT DAMPER COND. CONDENSATE CONC. CONCRETE CFM CUBIC FEET PER MINUTE EF EXHAUST FAN EA EACH E/A EXHAUST AIR FD FIRE DAMPER FLA FULL LOAD AMPS FPM FEET PER MINUTE FPS FEET PER SECOND HP HORSEPOWER HR HOUR IN. INCH KW KILOWATT LBS. POUNDS MAX. MAXIMUM VD MANUAL VOLUME DAMPER (OPPOSED BLADE TYPE) NO. NUMBER 0/A OUTSIDE AIR RPM. REVOLUTIONS PER MINUTE R/A RETURN AIR S/A SUPPLY AIR TEMP. TEMPERATURE T THERMOSTAT V VELOCITY VAV VARIABLE VOLUME BOX HVAC DESIGN REQUIRES: RECTANGULAR DUCT REINFORCEMENT NO DUCT SMOKE DETECTOR 2" W.G. STATIC POS. OR NEG. NO RENFORCEIAENT REQUIRED FIRE DAMPER(S) REINFORCEMENT X CODE FOR DUCT GAGE NO. 12' REINFORCEMENT SPACING OPTIONS FIRE RATED ROOF /FLOOR CEILING ASSEMBLY DUCT DIM. 10' 1 8' 1 6' 1 5' 1 4' 1 3' 1 2 -1/2' 1 2' 10" dn. 26 ga. 460 mm 3.7 m NOT REQUIRED 6.4 mm 25.4 X 0.85 mm 11 ", 12" 24 ga. TWO 10 ga. B-26 B-26 B-26 B-26 B-26 B-26 B-26 13 ", 14" 22 ga. B-24 B-26 B-26 B-26 B-26 B-26 B-26 1511,161, 20 ga. C-22 C-24 G24 C-26 C-26 C-26 B-26 B-26 17 ", 18" 20 ga. C-22 G24 G24 C-26 G26 C-26 G26 B-26 19 ", 20" 18 ga. C-20 C-22 G24 C-26 C-26 C-26 G26 G26 21 ", 22" 16 ga. D-20 D-22 D-24 D-26 C-26 C-26 C-26 G26 23 ", 24" 16 ga. 620 622 D•24 D•26 D-26 C-26 G26 C-26 25 ", 26" 620 618 F18 G-16 NOT DESIGNED 622 620 F=20 G-18 R16 1.16 624 622 622 620 G•18 K18 1-16G 1-16G D-26 624 624 622 G-20 K20 H-18G 1.18G J -16H D-26 D•26 626 624 624 G-22 K20G H-18G 1.18G 1.18G J -18H C-26 C•26 C-26 27 ", 28" D-26 C-26 G26 29 ", 30" D-26 D-26 C-26 31" - 36" 626 D-26 D-26 37" - 42" 624 626 626 43" - 48" F-24 624 624 49" - 54" G-24 624 F-24 55" - 60" G-22 G-24 F-24 61" - 72" H-22G K22G K24 73 " -84" 1-20G 1.22G 1-22G 85" - 96" 1-18H 1.20H 1-22H 97 "- 108" K 18H J -18H 1­18H 109" - 129' 1 K -181 J -181 HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR WIRE X FIRE DAMPER(S) DIAMETER X SMOKE DAMPER(S) X FIRE RATED ENCLOSURE 12' X FIRE RATED ROOF /FLOOR CEILING ASSEMBLY 1 "x 22 ga X FIRE STOPPING ONE 2.75 mm. X SMOKE CONTROL 11" - 18" X PROJ. No. 18056 EB0000924 LOUIS J. AGURRE A A- SSOGIA E§ 0.k: CONSULTING ENGINEERS 2600 DOUGLAS RD. SUITE 605 CORAL GABLRS,- R -ORIDA - - - ; _ " ' _ 33 LA ' TELEPHONE:�305; 444 -16%9' FAX: -(305) 4-48 -1 "OS _ _ '__„ E -MAIL ADDRESS: GRALMAIL@LJAAPA.COM . ^I Revisions: 0 0 0 2L, ZL V Z oC p im-• J m V H V o~C = a cn < u c1d w w V Q E- ~ %n oc� N N a it � N O FE O tn C� V1 O I- N n Ln Vl N W �o t- 0 m V � 9 V A 0 z LLA A I" wz V V LV r.j Q ...� c14 Oz rW, V V) PERMIT SET DRAWI+ MINIMUM HANGER SIZES FOR ROUND DUCTS DUCT MAXIMUM WIRE ROD STRAP DIAMETER SPACING DIAMETER 10 DN 12' ONE 12 ga. 1/4" 1 "x 22 ga 250 mm DN 3.7 m ONE 2.75 mm. 6 4 mm 25.4 X 0.85 mm 11" - 18" 12' TWO 12 ga. OR ONE ga. 1/4" 1 "x 22 ga 460 mm 3.7 m ONE 4.27 mm. 6.4 mm 25.4 X 0.85 mm 19"-24" 12' TWO 10 ga. 114" 1 "x 22 ga 610 mm 3.7 m TWO 3.51 mm. 6.4 mm 25.4 X 0.85 mm 25"-36" 12' TWO 8 ga. 3/8" 1 "x 20 ga 900 mm 3.7 m TWO 2.7 mm. 9.5 mm 25.4 X 1.00 mm 3711-5011 12' TWO 3/8" TWO 1" X 20 ga. 1270 mm 3.7 m TWO 9.5 mm TWO 25.4 X 1.00 mm 5111-6o.. 12' TWO 3/8" TWO 1" X 18 ga. 1520 mm 3.7 m TWO 9.5 mm TWO 25.4 X 1.31 mm 61"-84" 12' TWO 3/8" TWO 1" X 16 ga. 2130 mm 3 7 m TWO 9.5 mm TWO 25.4 X 1.61 mm NOTES: 1. STRAPS ARE GALVANIZED STEEL; RODS ARE UNCOATED OR GALVANIZED STEEL; WIRE IS BLACK ANNEALED, BRIGHT BASIC, OR GALVANIZED STEEL. ALL AREALTERNATIVES. 2. TABLEALLOWS FOR CONVENTIONAL WALL THICKNESS, AND JOINT SYSTEMS FLUS ONE LB /SF INSULATION WEIGHT. E HEAVIER DUCTS ARETO BE INSTALLED, ADJJST HANGER SIZES TO BEWTHIN THEIR LOAD LIMITS. HANGER SPACING MAY BEADJUSTED BY SPECIAL ANALYSIS. . ^I Revisions: 0 0 0 2L, ZL V Z oC p im-• J m V H V o~C = a cn < u c1d w w V Q E- ~ %n oc� N N a it � N O FE O tn C� V1 O I- N n Ln Vl N W �o t- 0 m V � 9 V A 0 z LLA A I" wz V V LV r.j Q ...� c14 Oz rW, V V) PERMIT SET DRAWI+ CHECKED: P.A. DATE- 09 -25 -05 SCALE: AS NOTED SEAL '., NIECHANI(fAD "" ;1rRNESTO, SA T-ANA'P.E. ... h Sheet No. M 0.0 0 JOB t 2a=