08-1177-020NOTE: THE DETAILS ON THIS SHEET ARE CONSIDERED TYPICAL AND ARE NOT NECESSARILY CALLED OUT ON PLANS NOTE: ALL RATED PENETRATION DETAILS ON THiS SHT. ARE TO COMPLY WITH UNITED STATES GYPSUM COMPANY DETAILS FOR HOSPITAL-4NDaNSTITU1iONAL CANS:1ZUc7ION. ^"' HANDBOOK DATED FEBRUARY 1991, REVISED AUGUST ISel. EQUIVALENT DETAIL NUMBERS ARE SHOWN WHERE APPLICABLE - ^ TRACK OR BLOCKING BAR JOISTS CLIP SCREW + METAL STUD CD LABELLED ACCESS PANEL 6 4' O.C. 5/8' TYPE 'X' 1-1/2' CRC F- I -v ^ 'J FIRE RETARDANT ' O 6' UNDER 6 FIRE RATED CEILING TREATED WOOD ^ ^ ^^ - -__ _ SEALANT O.G. • , • 2 1/2' C ON STUDS 16' FRTW BLOCK (2x4) PARALLEL 70 STRUCTURE RATED PARTITION SECTION AT CEILING LINER PANEL - bd ,. E -STUD ;. ~• SAFNG FASTENER ;ri. .• FASTEN TO E -STUDS J.-**.-.L STUDS 24' OTC, CHANNEL ;.- ol ^i - TRACK OR BLOCKING :, O -LABELLED ACCESS PANEL _^ IMPALING CLIPS BAR JOISTS _ PLAN VIEW (E STUDTENETO E-STUDS SCREWS -- CLIP AT EACH NOTES: _. F_- STUD 1. GYPSUM BOARD APPLIED VERTICALLY. '` OVER 6' UNDER 6' =': 5/8' TYPE 'X' r 2. JOINTS TO RECEIVE SHEETROCK TAPE AND JOINT COMPOUND. SEALANT 2FRM s ON (2x4) PLAN DETAIL AT SHAFT WALL SECTION RATED PARTITION PENETRATION OF 1 -HR RATED CEILING ASSEMBLY RATED PARTITION NOTE: BLOCKING IN WALL IS REQUIRED REF: UL SYSTEM No. 409 el j TYPICAL JOINT REQUIREMENTS FOR 1 HOUR LUALL N.T.S. 3 RATED PARTITION PENETRATION DETAIL NTS• �, MEMBRANE EDGE SUPPORT DETAIL NT.S. rj ACCESS PANEL INSTALLATION DETAIL Nrs. PERPENDICULAR TO STRUCTURE 1 OR 2 HOUR FIRE OR FIRE RESISTIVE MATERIAL SMOKE WALL SECURE ACOUSTICAL SEALANT 1l BRACE ANGLE 1' MIN. OVERLAP 2' -0' (PER UL) BOX AS NECESSARY BACK AND SIDES OF METAL STUDS FIRE DAMPER FOR SOUND RATING OPTIONAL �j' BREAKAWAY CONNECTION ONE OR TWO LAYERS OF DRYWALL SLEEVE k1d_ •k K• —1-• f— � AS REQUIRED FOR WALL CONST. i 5/S' TYPE 'X' GYP. BD. OPENING 14 FIRE S j j MATERIAL TWAT RATING ONE OR TWO LAYER OF DRYWALL LINED WITH FIRE WOOD STUD EQUAL TO THAT ON ACOUSTICAL SEALANT TAPE AND FINISH BEHIND CABINET I I RESISTIVE THE WALL (REQUIRED AROUND BOX PENETRATION BY AHCA) ALTERNATE I: BLOW -OUT ONE STRAPS WRAPPED AROUND ADJACENT ELECTRICAL � MAXi�IJI'1 16 Sa IN. STUDS SIZED AS REQUIRED FOR PIP SIDE OF WALL TAPE t JOINT MAXIMUM OPENING METAL STUDS MAY BE COMP. DRYWALL OR SEALANT too SQ INA00 SF. 4k7USED ON SOME U.L. TELEPHONE OR ELECTRICAL FIRE RATED ACOUSTIC APPROVED FIRE DAMPER T� t�A�JERS BOXES CEILING ASSEMBLY FIRE DAMPER - ANGLE IRON IN E of ALTERNATE 2: LAMINATE BACK PIECE C44A"�E OF CEILING HEIGHT AT RATED CEILING SLEEVE •' '• 1' MR OVERLAP _ I FACE TO SE SEALED WITH TO WALLBOARD BREAKAWAY •� � ��- - AND JOINTSEp TAPE r---- -----=--- - - - - -- -� . sue,•: - CONNECTION OPTIONAL LNNG OF I I S OVER 1' GAP REQUIRES A METAL STUD I OPENING: MAY REQUIRE I I SECURE WITH FIRE RESISTIVE BLOW -OUT PATCH MATERIAL of RATING OPENING TO BE LINED SHALLOW FIVE SiDE BOX DETAIL _ ___ ___________ _____ BRACE EQUAL TO THAT TI THE REQUIRED WHERE BOX EXCEEDS 16 SQ INCHES _:- s z .J METAL STUDS WALL FOR SOME FIRE PACK WITH THERMAFIVER Imam AGGREGATE WALL BOXES EXCEEDS IIdO SQ INJ DAMPER INSTALLATION :.. _..., DENSITY AT MANUFACTURED VARIES • �,w: ••� • DENSITY WITH NO VOIDS DAMPER REQUIRED (NOT READ. BY AHCA) �; ;�: y;�;:+ ;'• =. 1' MIN. OVERLAP OR GAPS ELECTRICAL JUNCTION BOXES " J 1 FIRE DAMPER SLEEVE WHEN A METALLIC JUNCTION BOX FOR ELECTRICAL RECEPTACLES OR SWITCHES 1S CONTAINED WITHIN (FIRE ONLY) °•..''� • ..,..•. - . ELECT. PANEL, PAC. OR OTHER DUCT BREAKAWAY K:... SECTION A -A A RATED WALL OF GYPSUM DRYWALL CONSTRUCTION AND AN OPENING IS PROVIDED FOR THE BOX N WALL MOUNTED CABINET T� "` '-'" "' ' " " E��- ALTERNATE I OR 2 MAY BE USED ON EITHER SIDE OF WALL. THE SURFACE OF THAT WALL, THE AREA OF THE OPENING MAY NOT EXCEED ib SQUARE INCHES, UNLESS 5/8' TH'E 'X' GYP. BD. CONNECTION S ( I ONE SIDE OF PENETRATION MAY REMAIN OPEN THE JUNCTION BOX IS ENCLOSED BY A 15 -SIDED BOX' (SEE APPROVED DETAILS) FUR WALL ABOVE AND BELOW CONCRETE OR MASONRY 'THE iDDEED BOXES 'DESCRIBED ABOVE SHALL NOTT EXCEED RATED SQUARE INCHES N 00 SQUARE FEET OF WALL AREA AS MEASURED FROM FLOOR TO STRUCTURAL DECK OR RATED MEMBRANE. �- -FIRE RATED JUNCTION BOXES WITH OPENINGS ON OPPOSITE FACES OF RATED WALLS SHALL HAVE A HORIZONTAL CEILING ASSEMBLY NOTE: SEPARATION OF 24 INCHES AS A MINIMUM, REGARDLESS OF BOX SIZE, UNLESS ENCLOSED BY ASSE SIT NON RATED SPECIFIC FRAMING REQUIREMENTS OF OPENINGS 5-SIDED BOXES.' CEILNG ASSEMBLY SHOULD BE PROVIDED N THE ARCHITECTURAL LOCATIONS OF STUDS DO NOT HAVE ANY BEARING ON THE ABOVE REQUIREMENTS, NOR DOES THE USE AND STRUCTURAL DRAWINGS THAT ARE SUBMITTED OF MINERAL WOOL FIRE SAFING ALTER THESE REQUIREMENTS. NOTE: 2 LAYERS 5/8' TYPE 'X' DRYWALL FOR BUILDING PEWITS. REF: UL SYSTEM No. WL 1065 EQUIV. TO SKETCH • 206, USG, HANDBOOK EQUiV. TO SKETCH • 101, USG, HANDBOOK AT 2 HOUR RATED CEILING ASSEMBLY BULKHEAD AT ONE -HOUR PITS -j DAMPER SLEEVE INSTALLATION DETAIL NrS. 8 MULTIPLE PIPE PENETRATION DETAIL N.Ts. 9 TYPICAL FIVE SIDE BOX DETAIL N.T.S. UOON RATED PART( OBINET DETAIL NTS RATED CE I L iNG ASSEMBLY Guide XHEZ Guide XHEZ October 03, 2001 Gulde XHEZ February 11, 199S Through- Penetration Firestop Systems Through- Penetration Firestop Systems C- AJ- 1080 -A Card Through - Penetration Firestop Systems W -L -1088 - A Card EXTEND WALL INTO OVER- February 1-1, 1998 HANGAND PARAPET ABOVE System No. IU -L -5014 W -L -5014 - A Card AND /ORSILL BELOW System No. C -AJ -1080 System No. W -L -1088 (Formerly System No. 636) SEAL ANY PENETRATIONS F- Rating - 3 Hr F- Rating - I and 2 Hr (See Item 1) F- Ratings - i and 2 Hr (See Item 1) I I THiW.UA L WITH ACOUSTICAL T- Rating - 0 Hr T- Rating - 0 Hr T- Rating - 1 Hr SEALANT I I L Rating At Ambient - Less Than 1 CFM /sq ft I 1 1/2' GYPSUM SHEATHING L Rating At 400 F - Less Than 1 CFM /sq ft L Rating At Ambient - Less Than 1 CFM /sq ft L Rating At 400 F - Less Than i CFM /ski ft I 1 EXTERIOR WALL MATERIAL I I �A 2 A 3B 1 1 1 3B 1 4 2 s a L L 4 ACOUST. SEALANT 2 METAL STUDS AS REQ'D, a° d FOR WIND LOAD TAPE t JOINT COMPOUND EXT. STUD WALL RUNNER 2 1 $ 2 TRACK CONTINUOUS I 3 LA 3 PLAN VIEW_ Section A -A LA Section A -A (Cont. on C- AJ- 1080 -B Card) (Cont'd on I111-L -1088 - 13 Card) 2 EQUIV: TO SKETCH 0 601, USG, HANDBOOK 3 � 16 �) FIRE AND /OR SMOKE WALL DETAIL NTS A AT EXTERIOR WALL L Floor or Wall Aesembiy - Min 4 -1/2 In. thick reinforced Ilghtwelght or normal weight 1. Wall Aesembly - The i or 2 hr, fire -rated gypsum wallboard /stud wall assembly shall be Section A- (100 -1514 pcf) concrete. Wall may also be constructed of any UL Classified Concrete constructed of the materials and In the manner described In the individual U300 or U400 Series Wall Blocks•. Max diem of opening is 32 In. or Partition Design in the UL Fire Resistance Directory and shall include the following construction (COnt'd Ott W-L-5014 - B Card) See Concrete Block (CAZf) category to the Fire Resistance Directory for names features: of manufacturers. A studs - Wall framing may consist of either wood studs or steel channel studs. Wood etude to 2. Through Penetrants - One metallic pipe, conduit or tubing to be cantered within consist of nom 2 by 4 In• lumber spaced 16 tn. O.C. with nom 2 by 4 in lumber end plates and cross the fTrestop eystem. The annular apace shall range from min 0 in. (point contact) to braces. Steel studs to be min. 3 -5/8 in. wide and spaced max 24 in. O.G. 1. Wall Assembl The 1 or 2 hr fire -rated sum wallboard /stud wall assembl shalt be constructed of the materials and in the manner max 2 in. Pipe, conduit or tubing to be rigidly supported on both aides of floor or B. Gypsum Boards - 5/8 Tn. thick` 4 ft wide with square or tapered edges. The gypsum wallboard y ' gyp y l `; -`;•'. }',, wall eesembly. The following types and sizes of metallic pipes, conduits or tubing may type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the described in the individual U300 or U400 Series Wall or Partition Design In the UL Fire Resistance Directory and shall include the used; individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max diem of opening is following construction features: 4k; {; y A Steel Pipe -Nom 30 In. diam (or smaller) Schedule 5 (or heavier) steel pipe. 6 -3/4 tm A. Studs - Wall Framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 In. lumber spaced - B• Iron Pipe -Nom 30 in diem (or smeller) cast or ductile iron pipe. The hourly F Rating of the Firestop system Ts equal to the hourly fire rating of the wall assembly in 16 in. OC. Steel studs to be min 3 -518 in. wide and spaced max 24 in. OC. _. a installed. B. sum Boards - 5/8 in. thick, 4 ft. wide with square or to Bred edges. The sum wallboard t e, thickness, number of la ers, `?:�`;, ^.:.' =,' G. Conduit -Nom 4 in diam for smaller) electrical metallic tubing or nom 6 to diam which it is install �p q 9 gyp 9 L `;rye d ; > >,:•,;';' (or smaller) rigid gale steel conduct. 2. Through Penetrant -One metallic pipe, tubing or conduct to be installed either concentrically fastener type and sheet orientation shall be as apeelfted in the individual U300 or U400 Series Design in the UL Fire Resistance D. Copper Tubing - Nom 6 im diam for smaller) Type M for heavier) copper tubing. or eccentrically within the firestop aystem. The annular apace between pipes, tubing or conduits and Directory. Max diam of opening is 18 Tn. ;� ,,' •. �• E. Copper Pipe -Nom 6 in. diam for smaller) Regular (or heavier) copper pipe. periphery of opening shall be min 0 in. (point contact) to max 5/8 fn. Pipe, tubing or conduit to be The hourly F Rating of the Firestop system to equal to the hourly fire rating of this wall assembly to which it is inste 3. Firestop System -The Firestop system shall consist of the following: rigidly supported on both sides of wall aeeenbly. The following typee and sizes of metallic pipes, 2. Through Penetrants -One metallic pips or tubing to be installed either concentrically or eccentrically within the Firestop system. Pipe or A Packing Material - (Optional, Not Shown) - Mineral wool batt Insulation, tubs or conduits may be used: tubing to be rigidly supported on both aides of wall assembly. The following types and sizes of metallic pipes or tubing may be used: ng polyetNlene backer rod or glass fiber batt insulation friction fitted into annular A eel Pipe -Nom 6 Tn dram for smaller) Schedule i0 (or heavier) steel pipe. A Steel Pipe :Nom 12 In. diam (or smaller) Schedule 10 (or heavier) steel pipe. space. Packing material to be recessed from top surface of floor or both surfaces B. Iron Pipe -Nom 6 In diam for smaller) cast or ductile iron pipe. B. Iron Pipe - Nom 12 in. diam (or smaller) east or ductile iron pipe. of well as required to accommodate the required thickness of fill material. C. Copper Tubing - Nom 6 in. diam (or smaller) Type M (or heavier) copper tubing. C, Copper Tubing - Nom 4 in. (or smaller) Type M (or heavier) copper tube. t;_r;' - >; •, ;;� B. Fill, Vold or Cavity Material• - Caulk - Min 1/2 in. thickness of fill material applied D. Copper Pipe - Nom 6 in. diam (or smaller) Regular (or heavier) copper pipe. `•tr' ^,;f?,, :, ; within the annulus, flush with top surface of floor or with both surfaces of wall. At E. Conduit -Nom 4 In clam for smaller) steel electrical metallic tubing, nom 4 in. clam (or smaller) D. Copper Pipe -Nom 4 tn. (or smaller) Regular for heavier) copper pipe. point contact location, apply min 1/4 in. diam bead of sealant at the pipe/concrete gaiv steel conduit or nom 1 im (or smaller) flexible steel conduit 3. Pipe Coverings• -One of this following tyypes of pipe coverings ahial) be used: A Pips and Equipment Coverin Materials• - Max 2 in. thick hollow IlndricaI heav densit (min 3.5 cr) lass fiber units jacketed on m„ r, interface on the top surface of the floor or both surfaces of wall. 3. Fill, void or Cavity Materials - Sealant - Min 5/8 in, thickness of fill material within annulus, flush p 9 y y p g j the outside with an all service jacket. Longitudinal oints sealed with metal rasteners or factor a lied self -seal! la tape. SPECIFIED TECHNOLOGIES INC - SpecSeal 100, 101, 102, 105, 120 or 12S sealant with both surfaces of wall. Additional fill material Installed such that a min 114 in. thick crown is formed j 9 j y' pp n9 p p •Hearin the UL Classification Mark around the penetrating item lapping 1/2 in. beyond the periphery of the opening. Transverse Joints secured with metal fasteners or with butt tope supplied with the product. The annular space between insulated �^ g SPECIFIED TECHNOLOGIES INC - LC 150, 151 152 and 155 Sealant penetrating item and the edge of the through opening shell be min 0 In. (continuous point contact) to max 1 -1/4 in. See Pipe and Equipment Coverin - Materials• - (BRSU) cat o in the Buildin Materials Director for names of manufacturers. ._, -Bearing the UL classification Marking nl, y Any pipe coverin terial meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index ;; •ry; >,, ;,,;, of 25 or less and a Smoke Developed Index of 50 or lose may be used. B. Pipe Covering Materials• -Max 2 in, thick unlaced minaret fiber pipe insulation having a nom density of 35 pcf (or heavier) and sized to the outside diam of pipe or tube. Pipe insulation secured with min 8 AWG steel wire spaced max 12 in. OC. The annular apace „i between insulated penetrating item and the edge of the through opening shall be min 0 tn. (continuous point contact) to max 1-1/4 in. OWENS CORNING HT INC, DIV OF OWENS CORNING - Paroc 1200, Paroc EW or Paroc Thermaloc 1200 C. Sheathing Material• -Used in conjunction with Item 313. Foil- scrim -kraft or all service Jacket material shall be wrapped around the outer circumference of the pipe Insulation (item 313) with the kraft aide exposed. Longitudinal joints and transverse Joints sealed with metal fasteners or butt tope. See St-eathing Materials (BVDV) category in the Building Materials Directory for names of manufacturers. Any sheathing material meeting this above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or leas and a Smoks Developed Index of 50 or less may be used. 4. Fill, Vold or Cavity Material• - Sealant - Min 5/8 in. thickness of fill material applied within annulus, flush with both surfaces of wall. At point contact location between insulated through penetrant and gypsum wallboard, a min 3/8 In. bead of fill material shall be applied to the insulated through penetrant/gypsum wallboard interface on both sides of the wall. SPECIFIED TECHNOLOGIES INC - SpecSeal 100, 101, 102 and 105 Sealant *Bearing the UL Classification Marking KTS. i� PENETRATION FIRESTOP DETAIL NrS. 18 PENETRATION FIRESTOP DETAIL N.rS. iPENETRATION FIRESTOP DETAIL KTS• Revisions: 0 0 R en -- o tn k+f a �Np aei4 p0 A w iE � Q W , M a In vii 00 �0 ysomm CIS o�� gal hi C Q� V w, O 110 a W a ..MN LL" z� W z o0 [-"z 1-0 < LLA td z W PERMIT SET DRAWM GAC CIIIECY.MLEN DATE: 9 -25 -08 SCALE: AS SHOWN SEAL,..:: { . � ,a9 Flt �•. `'� ' 'kill ,• ti' '; ,,, r-�MTi_- Sheet No. A -16 OF 17 JOB 28003 'I