08-1177-017EQ. Ea.
•• •.�j. ti„'� sT: » .... �' .� EXISTING
�.; ! `?►.s• �� �` ,4 .��.� _ . CONC. SLAB
• .� �' rte, ,•s1 3 -5/8'
MTL STUDS
UNDERSIDE OF FACE OF INISHED WALL , -
CONC SLAB 16' O.C.
w
ACOUSTICAL
CEILING
CEILING SUSPENSION
SYSTEM TO UNDERSIDE _ .
OF STRUCT. W
ACOUSTICAL
CEILING TILE
TCEILINGPAtNEL (SEE 5/8' G.W.B. �
SPECS FOR TYPE)
2 w
METAL ANGLE STRIP CEILING
FINISH TO MATCH GRID >
•1' SYSTr
T RUNNIER SUSPENDED ACOUSTICAL DOOR FRAME N
A
CEILING TILE, SEE SMOKE DETECTOR OR ACOUSTICAL
CEILING PLAN AND SPECS SP12INKLE 2 HEAD Z
CL
FOR TYPE O
NOTE, DO NOT SUPPORT SOFFIT
FROM FIRE RATED PARTITIONS.
AT FIRE PARTITIONS ANCHOR TO
STRUCTURE ABOVE
j CEILING DETAIL N.T.S. 2 CEILING DETAIL N.T.S. 3 CEILING DETAIL N.T.S. CEILING DETAIL N.T.S.
3116 TAPCONS . 16 O.C.
3/16' TAPCONS u 16. O.C. (I' MIN. EMBEDMENT) TYPICAL
(1' MIN. EMBEDMENT) TYPICAL
3116 TAPCONS . 16' O.C.
(I' MIN. EMBEDMENT) TYPICAL
BOTY. CONC. 33/8' 20 GAUGE METAL
SLAB STUD FRAMING 0 I6' O.C.
METAL STUDS. F. I •
3 -5/8' G: I '. •• +.' :.. FACE OF 2-3/8' PAN HEAD
MTL STUDS �. 'f`\ I EXISTING :. �: t !d° STUD t�2AMING SCREW
e 16' O.C. :# ` 1 CONC. SLAB
3 -5/8' MTL STUDS
\ \ EXISTING BRACKETS .
C: 3 -5/8' \\ \\ CONC. SLAB 4'-O' O.C.
MTL AT FIRE RATED BRACING e `
I I I I I I I I ILIA
\\ \ PAIR MTL N- O* O.C. `
\\ I \\ STUDS TO SLAB \ \ 5/8' G.WB.
ABOVE
J METAL CORNE12 GUARD
LL ACROSS SOFFIT. I I \ `\ \ `\ ACOUSTICAL
ACOUSTICAL I. 1 \\ \\ \` \ SEE INTERIOR CEILING TILE
Z CEILING TILE r I \ \ \ �� ELEVATION OR OR G.W.B. SEE
Q <L PAINTED Q F SEE INTERIOR \ \
5/8' G.W.B L• ELEVATION OR \` \ REF. CLG. PLAN REF. CLG. PLAN
F n I N REP. CLG. PLAN \
t n a \\ Z
Q u 3-5/8' 5/8' G.W.B. \ a
MTL STUDS \
016' O.C. N d
DOOR FRAME Z W � N
tL Q D > 3-5/8' METAL COR GUAR
0 5/8' G.W.B. MTL STUDS ACROSS SOFFIT, ACOUSTICAL 2 -3/8' PAN WAD
�- O 16 O.C. CEILING TILE > FRAMING SCREW _
SEE REF. CLG. PLAN [� OR G.W.B. SEE — 3-5/8' METAL
Z REF. CLG. PLAN VARIES 0 16 OAMING
K (SEE REFLECTED CLG PLAN
N
F` O
?j CEILING DETAIL N.T.S. CEILING DETAIL N.T.-S. SOFFIT DETAIL N.T.S. S SOFFIT DETAIL N.T.S.
3116 TAPCONS . 16' O.C.
(I' MIN. EMBEDMENT) TYPICAL
- -, --
\ EXISTING
. 1MTL STUDS I .a• EXISTING
MET STUDS. \\\ ; I CONC. SLAB 6' O.C. I :� `\\ I CONC. SLAB
I�
3-5/8' 5/8' G.W.B.
MTL BRACING e I \ I j 1 % 4 `\ 1 `\ AT FIRE RATED
PARTITION
4'-O' O.C. CCOUSTI LE I / \ \\\ ( \\\ STUDS TO SLAB
p \ I \ OR G.W.B. SEE li \t \ ABOVE
M \\ I \ REF. CLG. PLAN
Q Z 4 Z \ \ SEE INTERIOR �— --�
Zo
co tL AT FIRE RATED I \ ELEVATION OR
O PARTITION _J \ \ . REF. CLG. PLAN t , SOtj-iH ViUp`M1
f *�
METAL CORNER GUARD STUDS TO SLAB 3-5/8• C1TBUfj�G oEpT.
Q Z ACROSS SOFFIT. ABOVE MTL STUDS
1' @ 16. O.C. MTL STUDS SEE INTERIOR
OR UCTU�� S SON
O PAINTED FL ®16' O.C.
5/8' G.WB PLAN 1/4• ROUND MOLDING N Z W REF. CLG. PLAN $j
(I'-O' a CABINETS
ONLY) I 5/8' G.WB. PAINTED u- Q s
CABINET WORK (W1-RE 5/8' G.WB > ppPR0NJE1D
APPLIES) SEE INT. METAL CORNER GUARD
f�ATTIIONNS AND REF. ACROSS SOFFIT.
9
()
CEILING DETAIL N.T.s. 10 SOFFIT DETAIL N.T.S. jj SOFFIT DETAIL N.T.S. 12 N.T.S.
lteAdstons:
'A 0
0
0
�o
M�
a�
On
gn
H
w
W
H
n On
Vl
.S
m \0 r
pmuo
C43
.w.A
>n
Mil
O in 1
Qr��U a
w
O rtf i
v
m<
1-4
LLA
Q
V
z
V
PERMIT SET
DMVM GAC
C OMMMLEN
DATE: 9 -25 -08
SCALE: 1/4'=I'-O'
SEA4
•
• ��
Sheet No.
A -13
OF
17
JOB #' 28003