08-1177-013FINISH WALL OR
BACKSPLASH.
�— CAULKING
(TYPICAL)
/— FINISH STRIP (METAL)
2' -1' (TYP. U.ON.)�
3/4' PLYWOOD DECKING
AND SPLASH WITH PLASTIC
LAMINATE FINISH /
SINK (SEE
PLUMB.
DRWGS.)
SCHEDULED
FINISH WALL.
SCHEDULED FLOOR
AND BASE.
FINISH WALL OR
BACKSPLASH.
CAULKING
(TYPICAL).
BULLNOSE
EDGE.
— 5/8' PLYWOOD
b FACING WITH
ZPLASTIC LAMINATE
FINISH.
4
w
w
N
CORIAN
BULLNOSE
EDGE.
3/4' PLYWOOD
DECKING AND
SPLASH WITH
PLASTIC LAMINATE
FINISH.
HARDWARE (SEE
SPECS). TYPICAL.
5/8' PLYWOOD
FACING WITH
PLASTIC LAMINATE
FINISH,
LINE BORING WITH
CHROME PIN (TYP.)
AT ADJUSTABLE
SHELVES.
N.T.S.
PARTICLE BOARD.
4' BACKSPLASH. -
3/4' x 1 1/2' SPRUCE
FRAME (TYP.)
3/4' SPRUCE
BLOCKING.
(TYP.)
PLYWOOD t
HARDWOOD
BLOCKING.
1/4' PLYWOOD. —
2 x 4 WOOD
BLOCKING.
SCRIBED BOARD
3/4' PLYWOOD —
TOP
1/4' HARDWOOD
BACKING.
3/4' PLYWOOD —
ENDS.
LINE BORING WITH
CHROME PIN (TYP.)
3/4' PLYWOOD
BOTTOM.
CORIAN BULLNOSE
2' -1' (TYPICAL)
v
N
O
w
w
O
fy
w
Z
w
w
SOFFIT (WHERE
APPLICABLE) SEE
1' INTERIOR ELEVATIONS.
5/8' PLYWOOD FACING
'
WITH PLASTIC
FINISH.
LAMINATE FINISH.
0
APPLICABLE) SEE
w
1'
INTERIOR ELEVATIONS,
O
o
5/8' PLYWOOD
FACING WITH
ENDS.
3/4' ADJUSTABLE
I I
PLYWOOD SHELF
I I Z
WITH PLASTIC
I I
•p w
LAMINATE FINISH.
I I w
-1
HARDWARE (SEE
is 47
SPECS) TYPICAL.
WITH PLASTIC
SACKING..
O
LAMINATE FINISH.
i' -0' w
6
(TYP. U.ON.) z
w
} — FINISH WALL OR
W
tu BACKSPLASH (SEE
N
w INTERIOR ELEV.).
N.T.S.
—FINISH WALL OR
BACKSPLASH.
�-- CAULKING
(TYPICAL).
FINISH STRIP (METAL).
2' -1' (TYP. U.ON.) I,
3/4' PLYWOOD DECKING PLASTIC LAMINATE
AND SPLASH WIT4 PLASTIC BULLNOSE
LAMINATE FINISH. EDGE.
— 5/8' PLYWOOD
FACING WITH
r — — — — — 7
I
1 1
1 SAFE BOX
i
1
L — — J
— _ _ _ —
6
�r
`-- CONCRETE BASE
FOR SAFE. SEE
CDETAIL 9 ON SHT. A -14.
�I 1
DRAWER
17
3/4 EXT. GRADE
PLYWOOD WIN
PLASTIC LAMINATE
ON ALL ETIOSED
SURFACES
'Jg
0 0 00
FINISH.
CD
0
APPLICABLE) SEE
1'
INTERIOR ELEVATIONS,
O
O
5/8' PLYWOOD
FACING WITH
ENDS.
0 0
PLASTIC LAMINATE
j
}
FINISH.
U-1
J
-1
° ~
ONE 3/4' PLYWOOD FACING
w
w
WITH PLASTIC
SACKING..
° ° J
LAMINATE FINISH.
0
0
w
w
w
z
z
w
N
w
3/4' PLYWD.
ull
BOTTOM.
d)
HARDWARE (SEE
�r
`-- CONCRETE BASE
FOR SAFE. SEE
CDETAIL 9 ON SHT. A -14.
�I 1
DRAWER
17
3/4 EXT. GRADE
PLYWOOD WIN
PLASTIC LAMINATE
ON ALL ETIOSED
SURFACES
'Jg
0 0 00
FINISH WALL OR
1' -0' BACKSPLASH (SEE
INTERIOR ELEV.).
YP. U.ON.) p j
UNDER CABINET w O
LIGHT FIXTURE z d
(SEE ELECTRICAL DUJG'S) w w
w-1
CD D w
O
N.T.S.
SS. TRIM
NARDWAI;
SPECS? T
0
3 /TER. GRADE
PLYWOOD PLASTIC
LM COVERED
ALL VISIBLE
SURFACES
N.T.S.
z
HARDWARE
(SEE SPECS).
N.T.S.
N.T.S.
N.T.S.
CABINET GENERAL NOTES
1. WHERE CABINET END ABUTS A WALL, PROVIDE BACKSPLASH,
4' HIGH UNLESS OTHERWISE NOTED ON INTERIOR ELEVATIONS.
2. BACKSPLASH AND COUNTERTOP ARE CONTINUOUS AS SHOWN
ON INTERIOR ELEVATION.
3. PROVIDE CONTINUOUS SEALANT ALONG TOP OF BACKSPLASH
AT WALL.
4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AT FIELD.
COORDINATE ALL EQUIPMENT INSTALLED IN CABINETS, AND
SUBMIT SHOP DRAWINGS TO ARCHITECT FOR APPROVAL PRIOR
TO FABRICATION.
5. REFER TO 1/4' FLOOR PLANS AND INTERIOR ELEVATIONS FOR
MODIFICATIONS.
roo. ARCHITECT/ INTERIOR DESIGNER TO SELECT COLOR OF ALL
CABINET FINISHES.
1. REFER TO SHEETS 45.1 THROUGH -1 45.5
S. ALL INTERIOR CABINET FINISHES TO HAVE PLASTIC LINERS
(TYPICAL, UNLESS OTHERWISE NOTED.)
9. REFER TO INTERIOR ELEVATIONS FOR INDICATION OF
LOCKABLE OR NON - LOCKABLE FEATURES. REFER TO
SPECIFICATIONS FOR MATERIALS, LOCKS AND HARDWARE.
10, NO CABINETS ARE TO BE SUPPORTED OR HUNG FROM ANY
FIRE RATED PARTITION. CABINETS WILL BE HUNG FROM THE
SOFFIT ABOVE OR SUPPORTED BY ADJACENT NON -RATED
PARTITIONS. SEE FLOOR PLANS FOR EXACT LOCATION OF FIRE
RATED PARTITIONS.
11. PROVIDE EASED CORNER EDGES AT ALL CABINET TOPS
ABUTTING A WALL.
12, ALL CABINETS ARE TO BE CONSTRUCTED OF GRADE 'A'
PLYWOOD AND ARE TO BE FASTENED TOGETHER WITH
SCREWS.
13. ALL COUNTERTOPS CONNECTED TO WALLS MUST EITHER BE
SUPPORTED BY A BASE CABINET OR A FULL LENGTH LEG
SUPPORT,
14. MILL WORK MANUFACTURER SHALL INSTALL ONE PLASTIC
GROMMET PER EACH ELECTRICAL RECEPTACLE, TELEPHONE
OUTLET, CRT, OUTLET ECT. SPECIFIED ON THE EQUIPMENT PLANS
AND/ OR ELECTRICAL DRAWINGS. INSTALL WITHIN THE KNEE
SPACE OF ALL CABINETS SHOWN ON EQUIPMENT DRAWINGS.
15. GENERAL CONTRACTOR SHALL COORDINATE ANY NECESSARY
ACCESS REQUIREMENTS IN CABINETRY. ACCESS DOORS AND /OR
ACCESS PANELS SHALL BE INCLUDED AS PART OF THE CABINET
WORK WHEN NECESSARY TO INSTALL AND /OR SERVICE ANY TYPE
OF MECHANICAL, PLUMBING OR ELECTRICAL DEVICE THAT IS
CONCEALED BY THE CABINETRY.
16. STEEL STUDS SUPPORTING HUNG FIXTURE AND CABINETS SHALL
BE DOUBLE OR 20 GAUGE AS PER 2510.5 FBC 2004 A HORIZONTAL
MEMBER FASTENED TO NO LESS THAN 2 STUDS SHALL BE
PROVIDED AT WALL HUNG CABINETS AS PER 2510.5.1.1 F.B.C. 2004
A-
A
0
G
D
M
M b
°ate
O ?2
W
H
MGo
�- cn
N
tia
Hco
ao o
.mmo
cl
.w.a
a�
O
a.8�
O Ito �
ul
W
I-,
0
z
A
z
V)
r.r
W
A
W
z
V
PERMIT SET
DRAWN GAG
C MCKEDs LEN
DATE: 9 -25 -08
SCALE: AS SHOWN
SEAL-
... r
SOFFIT (WHERE
APPLICABLE) SEE
1'
INTERIOR ELEVATIONS,
3/4' PLYWOOD
5/8' PLYWOOD
FACING WITH
ENDS.
0 0
PLASTIC LAMINATE
FINISH.
3/4' PLYWOOD
p
TOP.
° ~
ONE 3/4' PLYWOOD FACING
OD
WITH PLASTIC
SACKING..
° ° J
LAMINATE FINISH.
w
LINE BORING: WITH
�
CHROME PIN (TYP.).
0 0
3/4' PLYWD.
BOTTOM.
o Z
HARDWARE (SEE
o o
SPECS).
FINISH WALL OR
1' -0' BACKSPLASH (SEE
INTERIOR ELEV.).
YP. U.ON.) p j
UNDER CABINET w O
LIGHT FIXTURE z d
(SEE ELECTRICAL DUJG'S) w w
w-1
CD D w
O
N.T.S.
SS. TRIM
NARDWAI;
SPECS? T
0
3 /TER. GRADE
PLYWOOD PLASTIC
LM COVERED
ALL VISIBLE
SURFACES
N.T.S.
z
HARDWARE
(SEE SPECS).
N.T.S.
N.T.S.
N.T.S.
CABINET GENERAL NOTES
1. WHERE CABINET END ABUTS A WALL, PROVIDE BACKSPLASH,
4' HIGH UNLESS OTHERWISE NOTED ON INTERIOR ELEVATIONS.
2. BACKSPLASH AND COUNTERTOP ARE CONTINUOUS AS SHOWN
ON INTERIOR ELEVATION.
3. PROVIDE CONTINUOUS SEALANT ALONG TOP OF BACKSPLASH
AT WALL.
4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AT FIELD.
COORDINATE ALL EQUIPMENT INSTALLED IN CABINETS, AND
SUBMIT SHOP DRAWINGS TO ARCHITECT FOR APPROVAL PRIOR
TO FABRICATION.
5. REFER TO 1/4' FLOOR PLANS AND INTERIOR ELEVATIONS FOR
MODIFICATIONS.
roo. ARCHITECT/ INTERIOR DESIGNER TO SELECT COLOR OF ALL
CABINET FINISHES.
1. REFER TO SHEETS 45.1 THROUGH -1 45.5
S. ALL INTERIOR CABINET FINISHES TO HAVE PLASTIC LINERS
(TYPICAL, UNLESS OTHERWISE NOTED.)
9. REFER TO INTERIOR ELEVATIONS FOR INDICATION OF
LOCKABLE OR NON - LOCKABLE FEATURES. REFER TO
SPECIFICATIONS FOR MATERIALS, LOCKS AND HARDWARE.
10, NO CABINETS ARE TO BE SUPPORTED OR HUNG FROM ANY
FIRE RATED PARTITION. CABINETS WILL BE HUNG FROM THE
SOFFIT ABOVE OR SUPPORTED BY ADJACENT NON -RATED
PARTITIONS. SEE FLOOR PLANS FOR EXACT LOCATION OF FIRE
RATED PARTITIONS.
11. PROVIDE EASED CORNER EDGES AT ALL CABINET TOPS
ABUTTING A WALL.
12, ALL CABINETS ARE TO BE CONSTRUCTED OF GRADE 'A'
PLYWOOD AND ARE TO BE FASTENED TOGETHER WITH
SCREWS.
13. ALL COUNTERTOPS CONNECTED TO WALLS MUST EITHER BE
SUPPORTED BY A BASE CABINET OR A FULL LENGTH LEG
SUPPORT,
14. MILL WORK MANUFACTURER SHALL INSTALL ONE PLASTIC
GROMMET PER EACH ELECTRICAL RECEPTACLE, TELEPHONE
OUTLET, CRT, OUTLET ECT. SPECIFIED ON THE EQUIPMENT PLANS
AND/ OR ELECTRICAL DRAWINGS. INSTALL WITHIN THE KNEE
SPACE OF ALL CABINETS SHOWN ON EQUIPMENT DRAWINGS.
15. GENERAL CONTRACTOR SHALL COORDINATE ANY NECESSARY
ACCESS REQUIREMENTS IN CABINETRY. ACCESS DOORS AND /OR
ACCESS PANELS SHALL BE INCLUDED AS PART OF THE CABINET
WORK WHEN NECESSARY TO INSTALL AND /OR SERVICE ANY TYPE
OF MECHANICAL, PLUMBING OR ELECTRICAL DEVICE THAT IS
CONCEALED BY THE CABINETRY.
16. STEEL STUDS SUPPORTING HUNG FIXTURE AND CABINETS SHALL
BE DOUBLE OR 20 GAUGE AS PER 2510.5 FBC 2004 A HORIZONTAL
MEMBER FASTENED TO NO LESS THAN 2 STUDS SHALL BE
PROVIDED AT WALL HUNG CABINETS AS PER 2510.5.1.1 F.B.C. 2004
A-
A
0
G
D
M
M b
°ate
O ?2
W
H
MGo
�- cn
N
tia
Hco
ao o
.mmo
cl
.w.a
a�
O
a.8�
O Ito �
ul
W
I-,
0
z
A
z
V)
r.r
W
A
W
z
V
PERMIT SET
DRAWN GAG
C MCKEDs LEN
DATE: 9 -25 -08
SCALE: AS SHOWN
SEAL-
... r
..
Sheet No.
A -9
OF
17
JOB * 28003