08-1177-001South M Hospita iami 1 Affiliate of Baptist Health Systems of South GENERAL NOTES I.- CONTRACTOR IS BEING PROVIDED WITH COMPLETE SETS OF DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUBCONTRACTORS WITH COMPLETE SETS OF DRAWINGS. INTENT IS FOR ALL SYSTEMS AND EQUIPMENT TO BE PROVIDED WITH UTILITY CONNECTIONS AS REQUIRED FOR OPERATION. EXAMPLE - IF A SINK IS SHOWN IN THE ARCHITECTURAL PLANS, THE PLUMBING PLANS DO NOT SHOW A WATER OR DRAWINGS CONNECTION THE ENGINEER WILL PROVIDE THE DESIGN DETAILS IN ACCORDANCE WITH THE DESIGN CRITERIA FOR THE REST OF THE INSTALLATIONS. CONTRACTOR IS RESPONSIBLE FOR PRO- VIDING THE CONNECTION AT NO ADDITIONAL COST TO THE OW- NER. 2- CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE DURING THE BIDDING PERIOD AND VERIFY THAT THE CONDITIONS ARE AS DESCRIBED IN THE DOCUMENTS. DISCREPANCIES ARE TO BE NOTED IN WRITING, AND NOTIFY ARCHITECT / ENGINEERS. CONTRACTOR ACCEPTS CONDITIONS AS THEY ARE ON THE SITE, AND MUST PROVIDE SYSTEMS AND WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS AT NO ADDITIONAL COST TO THE OWNER. 3.- DIMENSIONS PROVIDED ARE NOMINAL, NOT ACTUAL. THEY TAKE AS A BASIS EXISTING WALLS. IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT IMMEDIATELY FOR COORDINATION. IF CON- TRACTOR PROCEEDS, 14E DOES SO AT HIS OWN RISK AND IS RESPONSIBLE FOR ALL EXPENSES INCURRED, IF AT THE DISC12E TION OF THE OWNER OR THE ARCHITECT, TI-E WORK HAS TO BE RE -DONE 4.- SHUTDOWN OF UTILITIES, IF A SHUTDOWN OR ANY TYPE OF INTER- FERENCE WITH EXISTING SYSTEMS IS ANTICIPATED, THE CONT12AC TOR MUST NOTIFY THE OWNER, 72 HOURS IN ADVANCEAND OBTA- IN APPROVAL IN WRITING PRIOR TO PROCEEDING. 5.- CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS AND USE ALL APPROPRIATE CONSTRUCTION METHODS / TECHNIQUES TO PROTECT EXISTING UTILITIES AND OTHER PROPERTY NOT NOTED FOR REMOVAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGES INCURRED DURING CONSTRUCTION AND SHALL REPAIR ANY DAMAGES AT NO EXPENSE TO THE OWNER. 6- IF THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, THE CONTRACTOR IS TO OBTAIN CLARIFICATION DURING THE BIDDING PERIOD. IF THE DISCREPANCY COMES UP DU121NG THE CONSTRUCTION, IT IS ASSUMED THE CONTRACTOR BID THE MOST EXPENSIVE WAY AND WILL DO THE WORK AS PER THE DIRECTION OF THE OWNER /ARCHITECT AT NO ADDITIONAL COST TO THE OWNER. 7.- ABBREVIATIONS THROUGHOUT THE PLANS ARE THOSE IN COM- MON USE, ARCHITECT WILL DEFINE INTENT OF ANY IN QUESTION. 8.- THE CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY BARRIERS, LIGHTING, COVERINGS, FIRE PREVENTION AND OTHER EQUIPMENT TO PROTECT THE SAFETY OF ALL PERSONS AMID THE PROPERTY THROUGHOUT THE ENTIRE PERIOD OF THE CONSTRUC - TION CONTRACT. 9.- THE CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL, R ECTRICAL AND PLUMBING EQUIPMENT WITH SUBCONTRACTORS. AS WELL AS SHOP DRAWINGS AS APPROVED BY ARCHITECT, BEFORE PROCEEDING WITH THE WORK. 10- ALL ITEMS USED IN CONSTRUCTION. BUT NOT SPECIFICALLY MENTIONED 1 -REIN, SHALL CONFORM TO ALL LOCAL CODES AND STATE ORDINANCES AS TO APPLICATION AND USE 11- PROVIDE ELECTRIC INSULATION BETWEEN ALL DISSIMILAR METAL AND ALSO BETWEEN CEMENT AND METAL 12- THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS TO COMPLETE T 1 E PROJECT. 13.- CONTRACTOR TO REVIEW ALL EXISTING BUILDING SYSTEMS AS TO THIS R COMPLIANCE WITH ALL LOCAL AGENCY REQUIREMENTS AND BRING ANY NONCONFORMING ITEMS TO ARCHITECTS AMID ENGINEER'S ATTENTION. 14- GENERAL CONTRACTOR IS TO PROTECT EXISTING ADJACENT AREAS TO WHERE WORK IS TO BE PERFORMED. ANY EXISTING MILLWORK, EQUIPMENT DAMAGED DUE TO WORK PERFORMED SHALL BE REPAIRE DI REPLACED TO MATCH EXISTING (TYPICAL UNLESS OTHERWISE NOTED). 15- DRAWINGS ARE SCHEMATIC SHOWING RELATIVE LOCATIONS AND CONNECTIONS AND SHALL NOT BE SCALED AT ANY TIME. 16- ALL WOOD BLOCKING WITHIN BUILDING STRUCTURE, SHALL BE FIRE RETARDANT TREATED AS PER SPECIFICATIONS. 17.- GENERAL CONTRACTOR SHALL INSPECT ALL EXISTING RATED WALLS / PARTITIONS WITHIN SCOPE OF WORK AREA. CONTRACTOR SHALL UPGRADE EXISTING PARTITIONS AS REQUIRED TO MAINTAIN THE INTEGRITY OF THE DESIGNATED RATING. 18.- ELEVATION AMID LEVELSs A. ALL NUMERICAL ELEVATIONS ARE TO TOP OF CONCRETE SLAB. UNLESS NOTED OTHERWISE 19.- ALL INTERIOR GYPSUM WALL BOARD IS 5/8' TYPE X G.W.B. ON METAL STUDS OR FURRING CHANNELS UN-ESS NOTED OTHERWISE, SIZES AS DIMENSIONED ON FLOOR PLANS. SEE NOTES 9 FOR LOCATION OF WATER RESISTANT G.W.B. 20.- PROVIDE WATER RESISTANT TYPE X G.W.B. IN ALL TOILETS. AND JANITORS CLOSETS. 21- BEFORE PATCHING ANY FIRE - RATED C.M.U. PARTITION. FILL ANY EXPOSED CELLS SOLID WITH GROUT. 22.- PROVIDE FINISH WALL UNDER AND BEHIND ALL EQUIPMENT AND CASEWORK 23: LOCATION AND SIZE OF CEILING AND WALL ACCESS PANELS SHALL BE DETERMINED BY THE POSITION OF VALVES AND OTHER MECHANICAL AND ELECTRICAL ITEMS WHICH REQUIRE ACCESS. THE CONTRACTOR SHALL AND COORDINATE WIT14 ALL TRADES, APPROVE ALL FINAL LOCATIONS OF ACCESSTPANELS PRI IOR O INSTALLATION. 24- THERE SHALL BE NO BACK - TO BACK ELECTRICAL TELEPHONE OR OTHER OUTLETS. 25- ALL VERTICAL PIPING AND COLUMI1 S, EXPOSED IN ROOMS SHALL BE FURRED WITH METAL STUDS AND DRY WALL AND FINISHED TO MATCH ADJACENT WALLS, UNLESS NOTED OTHERWISE, EXCEPTION& A. ELECTRIC CLOSETS C. MECHANICAL ROOMS B. TELEPHONE CLOSETS D. STAIRS 26.- WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORTS. ALL PENETRATIONS TI -ROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE AND / OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE S.T.0 MATERIAL 27- SEE INTE21012 E;.EVATIONS FOR FINISHES AND FINISH DETAILS FOR INTERIOR SPACES. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR ACOUSTICAL TILE FINISH. 28- SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATION OF CEILING MOUNTED MECHANICAL, ELECTRICAL FIXTURES. 29.- STAGGE 12 JOINTS VERTICALLY AND HORIZONTALLY IN ALL G.W.B. PARTITION EA. SIDE OF PARTITION, JOINTS STAGGERED MINIMUM 7 -07. UNLESS OTHERWISE NOTED. 30. CONTRACTOR SHALL CONFIRM THAT ALL EXISTING EXPOSED STEEL COMPLIES WITH N.F.P.A FIRE PROTECTION REQUIRE- MENTS. CONTRACTOR SHALL PROVIDE ALL NECESSARY INSJLA- TION/FIRE PROTECTIVE COATINGS. 31. CONTRACTOR TO SUBMIT ALL SHOP DRAWINGS TO ARCHITECT AND THE BUILDING DEPA12TWENT FOR APPROVAL. (ELEVATOR, TRUSSES, WINDOWS, ETC) 32 CONTRACTOR REQUIRE' ` PULL 'RATE DEMOLITION PERMIT. BAPTIST HEALTH BREAST CENTER - SURGICAL PRACTICE SOUTH MIAMI HOSPITAL MEDICAL ARTS BUILDING 6200 S.W. 73 STREET SOUTH MIAMI, FLORIDA 33143 TEL: (786) 662 =4175 Fax: (786) 668 -5156 - INTERIOR REMODELING ONLY - SEPTEMBER 25, 2008 19 EB0000924 LOUIS J. AGUIRRE do ASSOCIATES P.A. CONSULTING ENGINEERS 2600 DOUGLAS RD. SUITE 605 CORAL GABLES, FLORIDA 33134 TELEPHONE: (305) 444 -1679 FAX: (305) 448 -1405 E -MAIL ADDRESS: GRALMAIL®LJAAPA.COM C ITY MAP ABBREVIATIONS EEiol WOE cr n SO- ,4i�GHIT�GiURA�. ��381�'iEYIATIONB: U!E?l�tNCrt -�?t� " !t+�CsS= � � , ; �111tl�ll rd m � YI�R�� - nYd.t� �l�il�}�iY,.IfT.l7 - � �■ JANITORS SINK L JOINT >� =2 WIIM + .. ::yt,•f row I1� .� � "`�•� � W. O DIAMETER �}. LAVATORY LW POUNDS A LBS/HR POUNDS PER HOUR LO LINEAR DIFFUSER A/C AIR CONDITIONING LP LOW POINT ACI AMERICAN CONCRETE INSTITUTE LT LIGHT ACP ASBESTOS CEMENT PIPE TM ACSC ASPHALTIC CONCRETE SURFACE COURSE mall ACU AIR CONDITIONING UNIT MATL MATERIAL ACT Aff MAX MAXIMUM � AREA DRAIN MC -in AOJ ADJUSTABLE MECH MECHANICAL A/E ARCHITECT/ENGNEER MEMB MEMBRANE AF ACCESS FLOORING MFR MANUFACTURER AFF ABOVE FINISHED FLOOR MIN MINIMUM AGGR AGGREGATE MISC MISCELANEOUS AHU AIR HANDLING UNIT MO MASONRY OPING ETI ALT ALTERNATE MTO MOUNTED AL ALUMINUM MTL METAL ANN ANNUNCIATOR MUL MULLION ANSI AMERICAN NATIONAL STANDARDS INSTITUTE MOLT MULTIPLE ANT ANTENNA AP ACCESS PANEL i APL ACCESS PLENUM APROX APPROXIMATE ARCH ARCHITECTURAL N NORTH ASB ASBESTOS NEC NATIONAL ELECTRIC CODE ASPH ASPHALT NIC NOT IN CONTRACT ASTM AMERICAN SOCIETY OF TESTING t MATERIALS RO M N NUMBER NOMINAL o NPL, 7 BAT BATTERY NTS NOT TO SCALE BO BOARD Q BITUM BITUMINOUS BLDG BUILDNG BLKG BLOCKING OA OVERALL BM BEAM OBS OBSCURE BOT _ BOTTOM r« ?�• i^ fl oC OD ON CENTER OUTSIDE DIAMETER DIM) ��� OFS OVERFLOW SCUPPER OPPOSITE CAB CABINET � CB CATCH BASIN CEM CEMENT CER GFM CERAMIC' CUBIC FEET PER MINUTE j PC PRECAST CONCRETE CG CORNER GUARD ¢ �+ ��. `" PJ PIPE JOINT CHP «1 CRICKET HIGH POINT j `.. I'F PL PLASTIC CI CAST IRON Ir P LAM PLASTIC LAMINATE CIC CAST IRON COVER -• PLAS PLASTER CIP CAST IRON PIPE PLYUID PLYWOOD CJ CONTROL JOINT I'. PANT CLG CEILNG PT PONT OR PATIENT CLGD CEILING DIFFUSER PTD PAPER TOWEL DISPENCER CLKG CAULKING PTN PARTITION CLO CLOSET PTR PAPER TOWEL RECEPTACLE 0 0 0 0 architect s FLORIDA LICENSE #M0002689 7400 N.W. 7th Street Suite 101 Miami, Florida. 33126 Tek (305)265-7177 Fax: (305)262 -8435 UDS & NAYA. AJ.A FI. AR0008063 PROJECT NUMBER: 28003 PERMIT SET INDEX OF LIFE SAFETY LS -1 FIRST FLOOR LIFE SAFETY PLAN LS -2 THIRD FLOOR LIFE SAFETY PLAN INTERIOR DESIGN ARCHITECTURAL SP -1 SITE PLAN. DRAWINGS A -1 DEMOLITION PLAN, LEGEND AND NOTES. A -2 FIRST FLOOR PLAN. A -3 THIRD FLOOR PLAN. A -4 FIRST EQUIPMENT PLAN. A -5 THIRD EQUIPMENT PLAN. A -6 FIRST REFLECTED CEILING PLAN. A -7 THIRD REFLECTED CEILING PLAN. A -8 INTERIOR ELEVATIONS. A -9 CABINET DETAILS AND NOTES.. A -10 FINISH SCHEDULE AND TYPICAL RESTROOM NOTES AND DETAILS. A -11 DOOR SCHEDULE, NOTES AND DETAILS. A -12 PARTITION TYPES, NOTES AND DETAILS. A -13 CEILING DETAILS. A -14 MISCELLANEOUS DETAILS. A -15 PENETRATION AND FIRE RATING DETAILS. A -16 PENETRATION AND FIRE RATING DETAILS. A -17 PENETRATION AND FIRE RATING DETAILS. MECHANICAL MO.00 SYMBOLS LEGEND AND GENERAL NOTES HVAC. M3.00 FIRST FLOOR PLAN -HVAC. M3.01 THIRD FLOOR PLAN -HVAC. M6.00 SCHEDULES HVAC. M7.00 DETAILS HVAC. PLUMBING PO.00 GENERAL NOTES AND DETAILS. P3.00 FIRST FLOOR PLAN - PLUMBING. P3.01 THIRD FLOOR PLAN - PLUMBING. P5.00 ISOMETRIC DIAGRAM - PLUMBING. P7.00 DEtAILS - PLUMBING. FIRE PROTECTION FPO.00 GENERAL NOTES AND DETAILS. FP3.00 FIRST FLOOR PLAN FIRE PROTECTION. F73.00 THIRD FLOOR PLAN FIRE PROTECTION. ELECTRICAL EO.00 GENERAL NOTES AND LEGEND- ELECTRICAL. EO.01 GENERAL NOTES AND DEMOLITION NOTES- ELECTRICAL. E3.00 FIRST FLOOR DEMOLITION PLAN - LIGHTING- ELECTRICAL. E3.01 FIRST FLOOR DEMOLITION PLAN - POWER- ELECTRICAL. E3.02 DEMOLITION THIRD FLOOR PLAN - LIGHTING- ELECTRICAL. E3.03 DEMOLITION THIRD FLOOR PLAN - POWER- ELECTRICAL. E3.04 FIRST FLOOR PLAN- LIGHTING- ELECTRICAL. E3.05 FIRST FLOOR PLAN - POWER- ELECTRICAL. E3.06 FIRST FLOOR PLAN - SYSTEMS - ELECTRICAL. E3.07 THIRD FLOOR PLAN - LIGHTING- ELECTRICAL. E3.08 THIRD FLOOR PLAN - POWER- ELECTRICAL. E3.09 THIRD FLOOR PLAN - SYSTEMS - ELECTRICAL. E5.00 RISER DIAGRAM - ELECTRICAL. E5.01 RISER DIAGRAM - ELECTRICAL. E6.00 PANEI.BOARD SCHEDULES - ELECTRICAL. BUILDING INFORMATION ORIGINAL BUILDING DESCRIPTION BUILDING JURISDICTION : SOUTH MIAMI, MIAMI DADE COUNTY PRIMARY USE CLASS : BUSINESS NUMBER OF STORIES : 6 FLOOR EXISTING BUILDING NEW PROJECT DESCRIPTION PROJECT AREA: 1ST FLOOR -2,803 SQ.FT. 3RD FLOOR -1,356 SQ.FT. TOTAL: 4,159 SQ.FT. INTERIOR ALTERATION: : LEVEL H SPRINKLED : FULLY SPRINKLERED APPLICABLE CODES FLORIDA BUILDING CODE 2004 EDITION FLORIDA FIRE PREVENTION CODE 2004 EDITION 0 0 AL A REVISIONS N APPROVED BY: I HB HOSE BIB DATE: HC HANDICAPPED WOWD HARDWOOD HOWE HARDWARE WIT HEIGHT HM HOLLOW METAL HORIZ HORIZONTAL 14P HIGH PONT HR HOUR NTR HEATER HVAC HEATING, VENTILATION, AND AIR CONDITIONING HYD HYDRANT I ID INSIDE DIAMETER l DIAM IN INCHES NT INTERIOR J JAN ABBREVIATIONS JB ,4i�GHIT�GiURA�. ��381�'iEYIATIONB: U!E?l�tNCrt -�?t� " !t+�CsS= � � , ; t AND JUNCTION L JANITORS SINK L JOINT WWF AAT WIIM L LENGTH C CENTERING LAM LAMINATE O DIAMETER LAV LAVATORY • POUND OR NUMBER LW POUNDS A LBS/HR POUNDS PER HOUR LO LINEAR DIFFUSER A/C AIR CONDITIONING LP LOW POINT ACI AMERICAN CONCRETE INSTITUTE LT LIGHT ACP ASBESTOS CEMENT PIPE M ACSC ASPHALTIC CONCRETE SURFACE COURSE ACU AIR CONDITIONING UNIT MATL MATERIAL ACT ACOUSTICAL CEILING TILE MAX MAXIMUM AD AREA DRAIN MC MEDICINE CABINET AOJ ADJUSTABLE MECH MECHANICAL A/E ARCHITECT/ENGNEER MEMB MEMBRANE AF ACCESS FLOORING MFR MANUFACTURER AFF ABOVE FINISHED FLOOR MIN MINIMUM AGGR AGGREGATE MISC MISCELANEOUS AHU AIR HANDLING UNIT MO MASONRY OPING ETI ALT ALTERNATE MTO MOUNTED AL ALUMINUM MTL METAL ANN ANNUNCIATOR MUL MULLION ANSI AMERICAN NATIONAL STANDARDS INSTITUTE MOLT MULTIPLE ANT ANTENNA AP ACCESS PANEL N APL ACCESS PLENUM APROX APPROXIMATE ARCH ARCHITECTURAL N NORTH ASB ASBESTOS NEC NATIONAL ELECTRIC CODE ASPH ASPHALT NIC NOT IN CONTRACT ASTM AMERICAN SOCIETY OF TESTING t MATERIALS RO M N NUMBER NOMINAL o NPL, NAME PLATE BAT BATTERY NTS NOT TO SCALE BO BOARD Q BITUM BITUMINOUS BLDG BUILDNG BLKG BLOCKING OA OVERALL BM BEAM OBS OBSCURE BOT _ BOTTOM r« ?�• i^ fl oC OD ON CENTER OUTSIDE DIAMETER DIM) ��� OFS OVERFLOW SCUPPER OPPOSITE CAB CABINET � CB CATCH BASIN CEM CEMENT CER GFM CERAMIC' CUBIC FEET PER MINUTE j PC PRECAST CONCRETE CG CORNER GUARD ¢ �+ ��. `" PJ PIPE JOINT CHP «1 CRICKET HIGH POINT j `.. I'F PL PLASTIC CI CAST IRON Ir P LAM PLASTIC LAMINATE CIC CAST IRON COVER -• PLAS PLASTER CIP CAST IRON PIPE PLYUID PLYWOOD CJ CONTROL JOINT PNT PANT CLG CEILNG PT PONT OR PATIENT CLGD CEILING DIFFUSER PTD PAPER TOWEL DISPENCER CLKG CAULKING PTN PARTITION CLO CLOSET PTR PAPER TOWEL RECEPTACLE CLP CRICKET LOW POINT CLR CLOSER CMP CORRUGATED METAL PIPE Q Cm CONCRETE MASONRY UNIT T CNTR COUNTER Q QUARTILE CO CLEAN OUT COL COLUMN COMM COMMUNICATION CONC CONCRETE R CONK CONNECTION CONSTS CONSTRUCTION R REAR CONT CONTINUOUS RA RETURN AIR CPT CARPET TILE PAD RADIUS CT CERAMIC TILE RIB REINFORCED BEAM GTR CENTER RCPT RECEPTION CTSK COUNTERSUNK E r% RD REIT.F REINFORCED REQ REQUIRED DBL DOUBLE RESL RESILIENT DEG DEGREE RGTR REGISTER DEPT DEPARTMENT RM ROOM DESiG DESIGNATION RO ROUGH OPENING DET DETAIL RWL RAN WATER LEADER OF DRINKING FOUNTAIN DG DOOR GRILLE DIA DIAMETER a DIAL DIAGRAM DIM DMENSION S STUCCO DIOR DISPENSER SC SCREED CONCRETE ON DO DOWN DOOR OPENING SCHED SCHEDULE OSP DRY STANDPIPE SEC SECOND DS DOWN SPOUT SD SMOKE DETECTOR DUGS DRAWINGS SECT SECTION OUR DRAWER SF SUPPLY FAN SG SPANDREL GLASS SGR SYNTHETIC GRADE s14R SHOWER SHEET EA EACH SIG SIG SIGNAL EC EPDXY COATING S SIMILAR WHO ELECTRIC HAND DRYER K SK S NK EL ELEVATION SM SHE14E ET METAL. EJ EXPANSION JOINT SINK SMOKE ELEC ELECTRICAL OND SOUND ELEV ELEVATOR SPEC SPECIFICATION EMER EMERGENCY SPKR SPEAKERS ENCL ENCLOSURE SQ SQUARE ENGR ENGINEER SQFT SQUARE FEET EFNL ELECTRICAL PANEL SST STAINLESS STEEL EQ EQUAL ST STREET EQPT EQUIPMENT OTC SOUND TRANSMISSION COEFFICIENT EST ESTIMATE STD STANDARD ET EXPANSION TANK ST-0 STORM DRAIN EWC ELECTRIC WATER COOLER STL STEEL EXH EXHAUST STRL STRUCTURAL EXST EXISTING SUSP SUSPENDED EXT EXTERIOR SYM SYMMETRICAL SYS SYSTE M F T FA FIRE ALARM FABL FIRE ALARM BELL T TOILET FD FLOOR DRAIN TB TIE BEAM FG FIBERGLASS TC TIE COLUMN FCO FLOOR CLEANOUT TEL TELEPHONE FD FIRE DAMPER TEMP TEMPERATURE FDC FIRE DEPARTMENT CONNECTOR T4G TONGUE AND GROVE FDR FIRE DOOR THK THICK PON FOUNDATIONS TOC TOP OF CURB FOV FIRE DEPARTMENT VALVE TOPP TOP OF PARAPET FEC FIRE EXTINGUISHER CARNET TOS TOP OF SLAB FEX FIRE EXTINGUISHER TP TOP OF PAVEMENT FF FINISH FLOOR TRD TREAD FH FIRE HYDRANT TS TUBULAR STEEL FIN FINISH TSTAT THERMOSTAT FL FLOOR TV TELEVISION FM FACTORY MANUAL TW TOP OF WALL FLASH FLASHING TYP TYPICAL FLG FLANGE FLOUR FLUORESCENT U FOG FACE OF CONCRETE FOP FACE OF FINISH LIO UNDERCUT "• FOM FACE OF MASONRY UL UNDERWRITER'S LABORATORIES FOS FACE OF STUD UNF UNFINISHED FPRF FIREPROOF LION UNLESS OTHERWISE NOTED FFM FEET PER MINUTE UOS UNLESS OTHER SPECIFIED FRD FRENCH DRAIN UR URINAL FS FULL SIZE UTIL UTILITY FT FOOT OR FEET v FTG FOOTING FT -LB FOOT POUNDS PURR PURRING VB VINYL BASE PUT FUTURE VCT VINYL COMPOSITION TILE VERT VERTICAL 4 VEST VESTIBULE VF VERIFY IN FIELD VOL VOLUME GA GAUGE VT VAPOR TIGHT GAL GALLON VTR VENT THRU ROOF GALV GALVANIZED � CITY OF SOUTH GENERATOR MIAMf_ BUILDING GL C44D GLASS GROUND DEPT, WR WIRE GLB GLASS BLOCK W wIT�H OW STRUCTURECN R1CD GRADE WC WATER CLOSET GWB GYPSUM WALL BOARD WCO WALL GLEANOUT GYP GYPSUM / I WO WOOD N APPROVED BY: I HB HOSE BIB DATE: HC HANDICAPPED WOWD HARDWOOD HOWE HARDWARE WIT HEIGHT HM HOLLOW METAL HORIZ HORIZONTAL 14P HIGH PONT HR HOUR NTR HEATER HVAC HEATING, VENTILATION, AND AIR CONDITIONING HYD HYDRANT I ID INSIDE DIAMETER l DIAM IN INCHES NT INTERIOR J JAN JANITOR JB JUNCTION BOX JCT JUNCTION JSK JANITORS SINK JT JOINT KO KNOCK OUT WF WALL FABRIC W/O WITHOUT WP WATER PROOF WSCT WANSCOT WT WEIGHT WWF WELDED WIRE FABRIC WIIM WELDED WIRE MESH i ' 41�