GENERAL NOTES
I.- CONTRACTOR IS BEING PROVIDED WITH COMPLETE SETS OF
DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING
SUBCONTRACTORS WITH COMPLETE SETS OF DRAWINGS. INTENT
IS FOR ALL SYSTEMS AND EQUIPMENT TO BE PROVIDED WITH
UTILITY CONNECTIONS AS REQUIRED FOR OPERATION.
EXAMPLE - IF A SINK IS SHOWN IN THE ARCHITECTURAL PLANS,
THE PLUMBING PLANS DO NOT SHOW A WATER OR DRAWINGS
CONNECTION THE ENGINEER WILL PROVIDE THE DESIGN DETAILS
IN ACCORDANCE WITH THE DESIGN CRITERIA FOR THE REST OF
THE INSTALLATIONS. CONTRACTOR IS RESPONSIBLE FOR PRO-
VIDING THE CONNECTION AT NO ADDITIONAL COST TO THE OW-
NER.
2- CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE DURING
THE BIDDING PERIOD AND VERIFY THAT THE CONDITIONS ARE
AS DESCRIBED IN THE DOCUMENTS. DISCREPANCIES ARE TO
BE NOTED IN WRITING, AND NOTIFY ARCHITECT / ENGINEERS.
CONTRACTOR ACCEPTS CONDITIONS AS THEY ARE ON THE SITE,
AND MUST PROVIDE SYSTEMS AND WORK AS DESCRIBED IN THE
CONTRACT DOCUMENTS AT NO ADDITIONAL COST TO THE OWNER.
3.- DIMENSIONS PROVIDED ARE NOMINAL, NOT ACTUAL. THEY TAKE
AS A BASIS EXISTING WALLS. IF DISCREPANCIES ARE FOUND,
NOTIFY ARCHITECT IMMEDIATELY FOR COORDINATION. IF CON-
TRACTOR PROCEEDS, 14E DOES SO AT HIS OWN RISK AND IS
RESPONSIBLE FOR ALL EXPENSES INCURRED, IF AT THE DISC12E
TION OF THE OWNER OR THE ARCHITECT, TI-E WORK HAS TO BE
RE -DONE
4.- SHUTDOWN OF UTILITIES, IF A SHUTDOWN OR ANY TYPE OF INTER-
FERENCE WITH EXISTING SYSTEMS IS ANTICIPATED, THE CONT12AC
TOR MUST NOTIFY THE OWNER, 72 HOURS IN ADVANCEAND OBTA-
IN APPROVAL IN WRITING PRIOR TO PROCEEDING.
5.- CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS AND
USE ALL APPROPRIATE CONSTRUCTION METHODS / TECHNIQUES
TO PROTECT EXISTING UTILITIES AND OTHER PROPERTY NOT
NOTED FOR REMOVAL CONTRACTOR SHALL BE RESPONSIBLE
FOR ANY DAMAGES INCURRED DURING CONSTRUCTION AND
SHALL REPAIR ANY DAMAGES AT NO EXPENSE TO THE OWNER.
6- IF THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND THE
SPECIFICATIONS, THE CONTRACTOR IS TO OBTAIN CLARIFICATION
DURING THE BIDDING PERIOD. IF THE DISCREPANCY COMES UP
DU121NG THE CONSTRUCTION, IT IS ASSUMED THE CONTRACTOR BID
THE MOST EXPENSIVE WAY AND WILL DO THE WORK AS PER THE
DIRECTION OF THE OWNER /ARCHITECT AT NO ADDITIONAL COST
TO THE OWNER.
7.- ABBREVIATIONS THROUGHOUT THE PLANS ARE THOSE IN COM-
MON USE, ARCHITECT WILL DEFINE INTENT OF ANY IN QUESTION.
8.- THE CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY
BARRIERS, LIGHTING, COVERINGS, FIRE PREVENTION AND OTHER
EQUIPMENT TO PROTECT THE SAFETY OF ALL PERSONS AMID THE
PROPERTY THROUGHOUT THE ENTIRE PERIOD OF THE CONSTRUC -
TION CONTRACT.
9.- THE CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL
OPENINGS FOR MECHANICAL, R ECTRICAL AND PLUMBING EQUIPMENT
WITH SUBCONTRACTORS. AS WELL AS SHOP DRAWINGS AS APPROVED
BY ARCHITECT, BEFORE PROCEEDING WITH THE WORK.
10- ALL ITEMS USED IN CONSTRUCTION. BUT NOT SPECIFICALLY MENTIONED
1 -REIN, SHALL CONFORM TO ALL LOCAL CODES AND STATE ORDINANCES
AS TO APPLICATION AND USE
11- PROVIDE ELECTRIC INSULATION BETWEEN ALL DISSIMILAR METAL
AND ALSO BETWEEN CEMENT AND METAL
12- THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL
PERMITS TO COMPLETE T 1 E PROJECT.
13.- CONTRACTOR TO REVIEW ALL EXISTING BUILDING SYSTEMS AS TO THIS R
COMPLIANCE WITH ALL LOCAL AGENCY REQUIREMENTS AND BRING ANY
NONCONFORMING ITEMS TO ARCHITECTS AMID ENGINEER'S ATTENTION.
14- GENERAL CONTRACTOR IS TO PROTECT EXISTING ADJACENT AREAS TO
WHERE WORK IS TO BE PERFORMED. ANY EXISTING MILLWORK,
EQUIPMENT DAMAGED DUE TO WORK PERFORMED SHALL BE REPAIRE DI
REPLACED TO MATCH EXISTING (TYPICAL UNLESS OTHERWISE NOTED).
15- DRAWINGS ARE SCHEMATIC SHOWING RELATIVE LOCATIONS AND
CONNECTIONS AND SHALL NOT BE SCALED AT ANY TIME.
16- ALL WOOD BLOCKING WITHIN BUILDING STRUCTURE, SHALL BE FIRE
RETARDANT TREATED AS PER SPECIFICATIONS.
17.- GENERAL CONTRACTOR SHALL INSPECT ALL EXISTING RATED WALLS /
PARTITIONS WITHIN SCOPE OF WORK AREA. CONTRACTOR SHALL UPGRADE
EXISTING PARTITIONS AS REQUIRED TO MAINTAIN THE INTEGRITY
OF THE DESIGNATED RATING.
18.- ELEVATION AMID LEVELSs
A. ALL NUMERICAL ELEVATIONS ARE TO TOP OF CONCRETE SLAB.
UNLESS NOTED OTHERWISE
19.- ALL INTERIOR GYPSUM WALL BOARD IS 5/8' TYPE X G.W.B. ON METAL
STUDS OR FURRING CHANNELS UN-ESS NOTED OTHERWISE, SIZES AS
DIMENSIONED ON FLOOR PLANS. SEE NOTES 9 FOR LOCATION OF
WATER RESISTANT G.W.B.
20.- PROVIDE WATER RESISTANT TYPE X G.W.B. IN ALL TOILETS.
AND JANITORS CLOSETS.
21- BEFORE PATCHING ANY FIRE - RATED C.M.U. PARTITION. FILL ANY
EXPOSED CELLS SOLID WITH GROUT.
22.- PROVIDE FINISH WALL UNDER AND BEHIND ALL EQUIPMENT AND CASEWORK
23: LOCATION AND SIZE OF CEILING AND WALL ACCESS PANELS SHALL BE
DETERMINED BY THE POSITION OF VALVES AND OTHER MECHANICAL AND
ELECTRICAL ITEMS WHICH REQUIRE ACCESS. THE CONTRACTOR SHALL AND
COORDINATE WIT14 ALL TRADES, APPROVE ALL FINAL LOCATIONS OF ACCESSTPANELS PRI IOR O
INSTALLATION.
24- THERE SHALL BE NO BACK - TO BACK ELECTRICAL TELEPHONE
OR OTHER OUTLETS.
25- ALL VERTICAL PIPING AND COLUMI1 S, EXPOSED IN ROOMS SHALL BE
FURRED WITH METAL STUDS AND DRY WALL AND FINISHED TO MATCH
ADJACENT WALLS, UNLESS NOTED OTHERWISE, EXCEPTION&
A. ELECTRIC CLOSETS C. MECHANICAL ROOMS
B. TELEPHONE CLOSETS D. STAIRS
26.- WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL AND PLUMBING ITEMS
PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO
STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORTS. ALL
PENETRATIONS TI -ROUGH RATED WALLS SHALL BE SEALED TO PROVIDE
FIRE, SMOKE AND / OR ACOUSTICAL ISOLATION OF SPACES WITH
APPROPRIATE FIRE S.T.0 MATERIAL
27- SEE INTE21012 E;.EVATIONS FOR FINISHES AND FINISH DETAILS FOR INTERIOR
SPACES. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR
ACOUSTICAL TILE FINISH.
28- SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATION OF
CEILING MOUNTED MECHANICAL, ELECTRICAL FIXTURES.
29.- STAGGE 12 JOINTS VERTICALLY AND HORIZONTALLY IN ALL G.W.B. PARTITION
EA. SIDE OF PARTITION, JOINTS STAGGERED MINIMUM 7 -07.
UNLESS OTHERWISE NOTED.
30. CONTRACTOR SHALL CONFIRM THAT ALL EXISTING EXPOSED
STEEL COMPLIES WITH N.F.P.A FIRE PROTECTION REQUIRE-
MENTS. CONTRACTOR SHALL PROVIDE ALL NECESSARY INSJLA-
TION/FIRE PROTECTIVE COATINGS.
31. CONTRACTOR TO SUBMIT ALL SHOP DRAWINGS TO ARCHITECT AND
THE BUILDING DEPA12TWENT FOR APPROVAL. (ELEVATOR, TRUSSES,
WINDOWS, ETC)
32 CONTRACTOR REQUIRE' ` PULL 'RATE DEMOLITION PERMIT.
BAPTIST HEALTH BREAST CENTER - SURGICAL PRACTICE
SOUTH MIAMI HOSPITAL
MEDICAL ARTS BUILDING
6200 S.W. 73 STREET SOUTH MIAMI, FLORIDA 33143
TEL: (786) 662 =4175 Fax: (786) 668 -5156
- INTERIOR REMODELING ONLY -
SEPTEMBER 25, 2008
19 EB0000924
LOUIS J. AGUIRRE do ASSOCIATES P.A.
CONSULTING ENGINEERS
2600 DOUGLAS RD. SUITE 605
CORAL GABLES, FLORIDA 33134
TELEPHONE: (305) 444 -1679
FAX: (305) 448 -1405
E -MAIL ADDRESS: GRALMAIL®LJAAPA.COM
C ITY MAP
ABBREVIATIONS
EEiol
WOE cr n SO-
,4i�GHIT�GiURA�. ��381�'iEYIATIONB: U!E?l�tNCrt -�?t� " !t+�CsS= � � , ;
�111tl�ll rd
m � YI�R�� - nYd.t� �l�il�}�iY,.IfT.l7
-
� �■
JANITORS SINK
L
JOINT
>�
=2
WIIM
+ .. ::yt,•f
row
I1� .�
� "`�•� �
W.
O DIAMETER
�}.
LAVATORY
LW
POUNDS
A
LBS/HR
POUNDS PER HOUR
LO
LINEAR DIFFUSER
A/C
AIR CONDITIONING
LP
LOW POINT
ACI
AMERICAN CONCRETE INSTITUTE
LT
LIGHT
ACP
ASBESTOS CEMENT PIPE
TM
ACSC
ASPHALTIC CONCRETE SURFACE COURSE
mall
ACU
AIR CONDITIONING UNIT
MATL
MATERIAL
ACT
Aff
MAX
MAXIMUM
�
AREA DRAIN
MC
-in
AOJ
ADJUSTABLE
MECH
MECHANICAL
A/E
ARCHITECT/ENGNEER
MEMB
MEMBRANE
AF
ACCESS FLOORING
MFR
MANUFACTURER
AFF
ABOVE FINISHED FLOOR
MIN
MINIMUM
AGGR
AGGREGATE
MISC
MISCELANEOUS
AHU
AIR HANDLING UNIT
MO
MASONRY OPING
ETI
ALT
ALTERNATE
MTO
MOUNTED
AL
ALUMINUM
MTL
METAL
ANN
ANNUNCIATOR
MUL
MULLION
ANSI
AMERICAN NATIONAL STANDARDS INSTITUTE
MOLT
MULTIPLE
ANT
ANTENNA
AP
ACCESS PANEL
i
APL
ACCESS PLENUM
APROX
APPROXIMATE
ARCH
ARCHITECTURAL
N
NORTH
ASB
ASBESTOS
NEC
NATIONAL ELECTRIC CODE
ASPH
ASPHALT
NIC
NOT IN CONTRACT
ASTM
AMERICAN SOCIETY OF TESTING t MATERIALS
RO M
N
NUMBER
NOMINAL
o
NPL,
7
BAT
BATTERY
NTS
NOT TO SCALE
BO
BOARD
Q
BITUM
BITUMINOUS
BLDG
BUILDNG
BLKG
BLOCKING
OA
OVERALL
BM
BEAM
OBS
OBSCURE
BOT
_
BOTTOM r« ?�• i^ fl
oC
OD
ON CENTER
OUTSIDE DIAMETER DIM)
���
OFS
OVERFLOW SCUPPER
OPPOSITE
CAB
CABINET �
CB
CATCH BASIN
CEM
CEMENT
CER
GFM
CERAMIC'
CUBIC FEET PER MINUTE
j
PC
PRECAST CONCRETE
CG
CORNER GUARD ¢ �+
��. `"
PJ
PIPE JOINT
CHP
«1
CRICKET HIGH POINT j
`.. I'F
PL
PLASTIC
CI
CAST IRON Ir
P LAM
PLASTIC LAMINATE
CIC
CAST IRON COVER -•
PLAS
PLASTER
CIP
CAST IRON PIPE
PLYUID
PLYWOOD
CJ
CONTROL JOINT
I'.
PANT
CLG
CEILNG
PT
PONT OR PATIENT
CLGD
CEILING DIFFUSER
PTD
PAPER TOWEL DISPENCER
CLKG
CAULKING
PTN
PARTITION
CLO
CLOSET
PTR
PAPER TOWEL RECEPTACLE
0 0 0 0
architect s
FLORIDA LICENSE #M0002689
7400 N.W. 7th Street Suite 101 Miami, Florida. 33126
Tek (305)265-7177 Fax: (305)262 -8435
UDS & NAYA. AJ.A FI. AR0008063
PROJECT NUMBER: 28003
PERMIT SET
INDEX OF
LIFE SAFETY
LS -1 FIRST FLOOR LIFE SAFETY PLAN
LS -2 THIRD FLOOR LIFE SAFETY PLAN
INTERIOR DESIGN
ARCHITECTURAL
SP -1 SITE PLAN.
DRAWINGS
A -1 DEMOLITION PLAN, LEGEND AND NOTES.
A -2 FIRST FLOOR PLAN.
A -3 THIRD FLOOR PLAN.
A -4 FIRST EQUIPMENT PLAN.
A -5 THIRD EQUIPMENT PLAN.
A -6 FIRST REFLECTED CEILING PLAN.
A -7 THIRD REFLECTED CEILING PLAN.
A -8 INTERIOR ELEVATIONS.
A -9 CABINET DETAILS AND NOTES..
A -10 FINISH SCHEDULE AND TYPICAL RESTROOM NOTES AND DETAILS.
A -11 DOOR SCHEDULE, NOTES AND DETAILS.
A -12 PARTITION TYPES, NOTES AND DETAILS.
A -13 CEILING DETAILS.
A -14 MISCELLANEOUS DETAILS.
A -15 PENETRATION AND FIRE RATING DETAILS.
A -16 PENETRATION AND FIRE RATING DETAILS.
A -17 PENETRATION AND FIRE RATING DETAILS.
MECHANICAL
MO.00 SYMBOLS LEGEND AND GENERAL NOTES HVAC.
M3.00 FIRST FLOOR PLAN -HVAC.
M3.01 THIRD FLOOR PLAN -HVAC.
M6.00 SCHEDULES HVAC.
M7.00 DETAILS HVAC.
PLUMBING
PO.00 GENERAL NOTES AND DETAILS.
P3.00 FIRST FLOOR PLAN - PLUMBING.
P3.01 THIRD FLOOR PLAN - PLUMBING.
P5.00 ISOMETRIC DIAGRAM - PLUMBING.
P7.00 DEtAILS - PLUMBING.
FIRE PROTECTION
FPO.00 GENERAL NOTES AND DETAILS.
FP3.00 FIRST FLOOR PLAN FIRE PROTECTION.
F73.00 THIRD FLOOR PLAN FIRE PROTECTION.
ELECTRICAL
EO.00 GENERAL NOTES AND LEGEND- ELECTRICAL.
EO.01 GENERAL NOTES AND DEMOLITION NOTES- ELECTRICAL.
E3.00 FIRST FLOOR DEMOLITION PLAN - LIGHTING- ELECTRICAL.
E3.01 FIRST FLOOR DEMOLITION PLAN - POWER- ELECTRICAL.
E3.02 DEMOLITION THIRD FLOOR PLAN - LIGHTING- ELECTRICAL.
E3.03 DEMOLITION THIRD FLOOR PLAN - POWER- ELECTRICAL.
E3.04 FIRST FLOOR PLAN- LIGHTING- ELECTRICAL.
E3.05 FIRST FLOOR PLAN - POWER- ELECTRICAL.
E3.06 FIRST FLOOR PLAN - SYSTEMS - ELECTRICAL.
E3.07 THIRD FLOOR PLAN - LIGHTING- ELECTRICAL.
E3.08 THIRD FLOOR PLAN - POWER- ELECTRICAL.
E3.09 THIRD FLOOR PLAN - SYSTEMS - ELECTRICAL.
E5.00 RISER DIAGRAM - ELECTRICAL.
E5.01 RISER DIAGRAM - ELECTRICAL.
E6.00 PANEI.BOARD SCHEDULES - ELECTRICAL.
BUILDING INFORMATION
ORIGINAL BUILDING DESCRIPTION
BUILDING
JURISDICTION : SOUTH MIAMI, MIAMI DADE COUNTY
PRIMARY USE CLASS : BUSINESS
NUMBER OF STORIES : 6 FLOOR EXISTING BUILDING
NEW PROJECT DESCRIPTION
PROJECT AREA: 1ST FLOOR -2,803 SQ.FT.
3RD FLOOR -1,356 SQ.FT.
TOTAL: 4,159 SQ.FT.
INTERIOR ALTERATION: : LEVEL H
SPRINKLED : FULLY SPRINKLERED
APPLICABLE CODES
FLORIDA BUILDING CODE 2004 EDITION
FLORIDA FIRE PREVENTION CODE 2004 EDITION
0
0
AL
A
REVISIONS
N
APPROVED BY:
I
HB HOSE BIB DATE:
HC HANDICAPPED
WOWD HARDWOOD
HOWE HARDWARE
WIT HEIGHT
HM HOLLOW METAL
HORIZ HORIZONTAL
14P HIGH PONT
HR HOUR
NTR HEATER
HVAC HEATING, VENTILATION, AND AIR CONDITIONING
HYD HYDRANT
I
ID INSIDE DIAMETER l DIAM
IN INCHES
NT INTERIOR
J
JAN
ABBREVIATIONS
JB
,4i�GHIT�GiURA�. ��381�'iEYIATIONB: U!E?l�tNCrt -�?t� " !t+�CsS= � � , ;
t AND
JUNCTION
L
JANITORS SINK
L
JOINT
WWF
AAT
WIIM
L
LENGTH
C CENTERING
LAM
LAMINATE
O DIAMETER
LAV
LAVATORY
• POUND OR NUMBER
LW
POUNDS
A
LBS/HR
POUNDS PER HOUR
LO
LINEAR DIFFUSER
A/C
AIR CONDITIONING
LP
LOW POINT
ACI
AMERICAN CONCRETE INSTITUTE
LT
LIGHT
ACP
ASBESTOS CEMENT PIPE
M
ACSC
ASPHALTIC CONCRETE SURFACE COURSE
ACU
AIR CONDITIONING UNIT
MATL
MATERIAL
ACT
ACOUSTICAL CEILING TILE
MAX
MAXIMUM
AD
AREA DRAIN
MC
MEDICINE CABINET
AOJ
ADJUSTABLE
MECH
MECHANICAL
A/E
ARCHITECT/ENGNEER
MEMB
MEMBRANE
AF
ACCESS FLOORING
MFR
MANUFACTURER
AFF
ABOVE FINISHED FLOOR
MIN
MINIMUM
AGGR
AGGREGATE
MISC
MISCELANEOUS
AHU
AIR HANDLING UNIT
MO
MASONRY OPING
ETI
ALT
ALTERNATE
MTO
MOUNTED
AL
ALUMINUM
MTL
METAL
ANN
ANNUNCIATOR
MUL
MULLION
ANSI
AMERICAN NATIONAL STANDARDS INSTITUTE
MOLT
MULTIPLE
ANT
ANTENNA
AP
ACCESS PANEL
N
APL
ACCESS PLENUM
APROX
APPROXIMATE
ARCH
ARCHITECTURAL
N
NORTH
ASB
ASBESTOS
NEC
NATIONAL ELECTRIC CODE
ASPH
ASPHALT
NIC
NOT IN CONTRACT
ASTM
AMERICAN SOCIETY OF TESTING t MATERIALS
RO M
N
NUMBER
NOMINAL
o
NPL,
NAME PLATE
BAT
BATTERY
NTS
NOT TO SCALE
BO
BOARD
Q
BITUM
BITUMINOUS
BLDG
BUILDNG
BLKG
BLOCKING
OA
OVERALL
BM
BEAM
OBS
OBSCURE
BOT
_
BOTTOM r« ?�• i^ fl
oC
OD
ON CENTER
OUTSIDE DIAMETER DIM)
���
OFS
OVERFLOW SCUPPER
OPPOSITE
CAB
CABINET �
CB
CATCH BASIN
CEM
CEMENT
CER
GFM
CERAMIC'
CUBIC FEET PER MINUTE
j
PC
PRECAST CONCRETE
CG
CORNER GUARD ¢ �+
��. `"
PJ
PIPE JOINT
CHP
«1
CRICKET HIGH POINT j
`.. I'F
PL
PLASTIC
CI
CAST IRON Ir
P LAM
PLASTIC LAMINATE
CIC
CAST IRON COVER -•
PLAS
PLASTER
CIP
CAST IRON PIPE
PLYUID
PLYWOOD
CJ
CONTROL JOINT
PNT
PANT
CLG
CEILNG
PT
PONT OR PATIENT
CLGD
CEILING DIFFUSER
PTD
PAPER TOWEL DISPENCER
CLKG
CAULKING
PTN
PARTITION
CLO
CLOSET
PTR
PAPER TOWEL RECEPTACLE
CLP
CRICKET LOW POINT
CLR
CLOSER
CMP
CORRUGATED METAL PIPE
Q
Cm
CONCRETE MASONRY UNIT
T
CNTR
COUNTER
Q
QUARTILE
CO
CLEAN OUT
COL
COLUMN
COMM
COMMUNICATION
CONC
CONCRETE
R
CONK
CONNECTION
CONSTS
CONSTRUCTION
R
REAR
CONT
CONTINUOUS
RA
RETURN AIR
CPT
CARPET TILE
PAD
RADIUS
CT
CERAMIC TILE
RIB
REINFORCED BEAM
GTR
CENTER
RCPT
RECEPTION
CTSK
COUNTERSUNK
E
r%
RD
REIT.F
REINFORCED
REQ
REQUIRED
DBL
DOUBLE
RESL
RESILIENT
DEG
DEGREE
RGTR
REGISTER
DEPT
DEPARTMENT
RM
ROOM
DESiG
DESIGNATION
RO
ROUGH OPENING
DET
DETAIL
RWL
RAN WATER LEADER
OF
DRINKING FOUNTAIN
DG
DOOR GRILLE
DIA
DIAMETER
a
DIAL
DIAGRAM
DIM
DMENSION
S
STUCCO
DIOR
DISPENSER
SC
SCREED CONCRETE
ON
DO
DOWN
DOOR OPENING
SCHED
SCHEDULE
OSP
DRY STANDPIPE
SEC
SECOND
DS
DOWN SPOUT
SD
SMOKE DETECTOR
DUGS
DRAWINGS
SECT
SECTION
OUR
DRAWER
SF
SUPPLY FAN
SG
SPANDREL GLASS
SGR
SYNTHETIC GRADE
s14R
SHOWER
SHEET
EA
EACH
SIG
SIG
SIGNAL
EC
EPDXY COATING
S
SIMILAR
WHO
ELECTRIC HAND DRYER
K
SK
S NK
EL
ELEVATION
SM
SHE14E ET METAL.
EJ
EXPANSION JOINT
SINK
SMOKE
ELEC
ELECTRICAL
OND
SOUND
ELEV
ELEVATOR
SPEC
SPECIFICATION
EMER
EMERGENCY
SPKR
SPEAKERS
ENCL
ENCLOSURE
SQ
SQUARE
ENGR
ENGINEER
SQFT
SQUARE FEET
EFNL
ELECTRICAL PANEL
SST
STAINLESS STEEL
EQ
EQUAL
ST
STREET
EQPT
EQUIPMENT
OTC
SOUND TRANSMISSION COEFFICIENT
EST
ESTIMATE
STD
STANDARD
ET
EXPANSION TANK
ST-0
STORM DRAIN
EWC
ELECTRIC WATER COOLER
STL
STEEL
EXH
EXHAUST
STRL
STRUCTURAL
EXST
EXISTING
SUSP
SUSPENDED
EXT
EXTERIOR
SYM
SYMMETRICAL
SYS
SYSTE M
F
T
FA
FIRE ALARM
FABL
FIRE ALARM BELL
T
TOILET
FD
FLOOR DRAIN
TB
TIE BEAM
FG
FIBERGLASS
TC
TIE COLUMN
FCO
FLOOR CLEANOUT
TEL
TELEPHONE
FD
FIRE DAMPER
TEMP
TEMPERATURE
FDC
FIRE DEPARTMENT CONNECTOR
T4G
TONGUE AND GROVE
FDR
FIRE DOOR
THK
THICK
PON
FOUNDATIONS
TOC
TOP OF CURB
FOV
FIRE DEPARTMENT VALVE
TOPP
TOP OF PARAPET
FEC
FIRE EXTINGUISHER CARNET
TOS
TOP OF SLAB
FEX
FIRE EXTINGUISHER
TP
TOP OF PAVEMENT
FF
FINISH FLOOR
TRD
TREAD
FH
FIRE HYDRANT
TS
TUBULAR STEEL
FIN
FINISH
TSTAT
THERMOSTAT
FL
FLOOR
TV
TELEVISION
FM
FACTORY MANUAL
TW
TOP OF WALL
FLASH
FLASHING
TYP
TYPICAL
FLG
FLANGE
FLOUR
FLUORESCENT
U
FOG
FACE OF CONCRETE
FOP
FACE OF FINISH
LIO
UNDERCUT "•
FOM
FACE OF MASONRY
UL
UNDERWRITER'S LABORATORIES
FOS
FACE OF STUD
UNF
UNFINISHED
FPRF
FIREPROOF
LION
UNLESS OTHERWISE NOTED
FFM
FEET PER MINUTE
UOS
UNLESS OTHER SPECIFIED
FRD
FRENCH DRAIN
UR
URINAL
FS
FULL SIZE
UTIL
UTILITY
FT
FOOT OR FEET
v
FTG
FOOTING
FT -LB
FOOT POUNDS
PURR
PURRING
VB
VINYL BASE
PUT
FUTURE
VCT
VINYL COMPOSITION TILE
VERT
VERTICAL
4
VEST
VESTIBULE
VF
VERIFY IN FIELD
VOL
VOLUME
GA
GAUGE
VT
VAPOR TIGHT
GAL
GALLON
VTR
VENT THRU ROOF
GALV
GALVANIZED
�
CITY OF SOUTH
GENERATOR MIAMf_
BUILDING
GL
C44D
GLASS
GROUND DEPT,
WR
WIRE
GLB
GLASS BLOCK
W
wIT�H OW
STRUCTURECN
R1CD
GRADE
WC
WATER CLOSET
GWB
GYPSUM WALL BOARD
WCO
WALL GLEANOUT
GYP
GYPSUM / I
WO
WOOD
N
APPROVED BY:
I
HB HOSE BIB DATE:
HC HANDICAPPED
WOWD HARDWOOD
HOWE HARDWARE
WIT HEIGHT
HM HOLLOW METAL
HORIZ HORIZONTAL
14P HIGH PONT
HR HOUR
NTR HEATER
HVAC HEATING, VENTILATION, AND AIR CONDITIONING
HYD HYDRANT
I
ID INSIDE DIAMETER l DIAM
IN INCHES
NT INTERIOR
J
JAN
JANITOR
JB
JUNCTION BOX
JCT
JUNCTION
JSK
JANITORS SINK
JT
JOINT
KO KNOCK OUT
WF
WALL FABRIC
W/O
WITHOUT
WP
WATER PROOF
WSCT
WANSCOT
WT
WEIGHT
WWF
WELDED WIRE FABRIC
WIIM
WELDED WIRE MESH
i