08-1048-019IIIIIIIIIIIAII IIIIIIIIIIIAII w M LLJ U W F- 40 7 n ESSENTIAL DEMAND LOAD SUMMARY EXISTING LOAD: 2,831.8 KVA NEW ADDED DEMAND LOAD: 0.36 KVA NEW TOTAL DEMAND LOAD: 2,832.2 KVA OF 4#350, . EACH 0 4:0 60A OBI MAIN CIRCUIT BREAKER DISCONNECT. ..i i Ti7 CONNECT •. PROVIDED BY VARIAN. VARIAN HF CABINET BY 3.51XION SURFACE ELECTRICAL DUCT WITH TWO PARTITIONS FROM i' STAND ON ii- ELECTRICAL DUCT SHALL BE WALKER WALLDUCT (WDIOW350 ` PANEL PROVIDE NEW 3P,70A CIRCUIT BREAKER TO MATCH EXISTING. USE EXISTING 1- SPARE CONDUIT STUB OUT FROM LINAC ROOM AND EXISTING TO MODIFIED. R i UPDATED, i PANEL DIRECTORY. PANEL, 1LE7 OC DEVICE TYPE, Breaker ENCLOSURE, NEMA 1 MAINSCA), 100A CONTINUOUS(A), 100 LOCATION, DEVICE FAMILY+ Holt On MOUNTING, Surface WIRING, 3 -Phase 4 -Were AIC RATING(A), 10000 FED FROM, XFMR 1LE7 SEC VOLTAGE, 208/120 FAULT CURRENT(A) 1737 EXISTING PANEL CKT DESCRIPTION NOTES DEMAND VA OC PHASE OC VA DEMAND NOTES DESCRIPTION CKT AVE AMPS TYPE SIZE P CODE 1 AMPS P 0.00 AMPS P 0100 CODE I 100 3 15 1 NURSE STATION 145.00 RECEPTACLES 360 20 1 A 20 1 600 GENERAL EQUI SPARE FILM VIEWER 2 3 NURSE STATION 100 RECEPTACLES 900 20 1 B 20 1 720 RECEPTACLES 10.89 EXAM ROOM 4 5 EXAM RTU -R -1 LIGHTING 720 20 1 C 20 1 720 RECEPTACLES 6 EXAM ROOM 6 7 CONTROL CONSOLE 22.57 RECEPTACLES 720 20 1 A 20 1 360 RECEPTACLES 15.00 ELEC ROOM 8 9 CONTROL CONSOLE 8 RECEPTACLES 720 20 1 B 20 1 600 LIGHTING 150 LINAC ROOM 10 11 CONTROL CONSOLE 0.00 RECEPTACLES 720 20 1 C 20 1 600 GENERAL EQUI 0.00 FILM VIEWER 12 13 NURSE STATION UC REF 225 GENERAL EQUI 600 20 1 A 20 1 600 GENERAL EQUI 3 FILM VIEWER 14 15 EXAM 0100 LIGHTING 720 20 1 B 20 1 720 RECEPTACLES 0.00 LASER RM 132 16 17 EXAM 3 LIGHTING 720 20 1 C 20 1 720 RECEPTACLES 0 LASER RM 133 18 19 EXAM TOTAL DEMAND 142.08 170.9 ■ B -N 87960.6 317.4 DEMAND 142.08 LIGHTING 720 20 1 A 20 1 360 RECEPTACLES NURSE STATION 20 21 NURSE CALL INTERCOM GENERAL EQUI 750 20 1 B 20 1 720 GENERAL EQUI CCTV CAMERA 22 23 SPARE SPARE 0 20 1 C 20 1 720 GENERAL EQUI CCTV CAMERA 24 25 LINAC CONTROL NOTE 1 RECEPTACLES 360 20 1 A 20 1 600 GENERAL EQUI TELEPHONE 26 27 SPARE SPARE 0 20 1 B 20 1 980 GENERAL EQUI 11C EQUIPMENT 28 29 SPARE SPARE 0 20 1 C 20 1 720 RECEPTACLES LASER RM 122 30 ALL CONNECTED KVA 3P AVE AMPS w PHASE TOTALS VA AMPS BUS TOTALS KVA TOTAL CONNECTED 17.75 49.3 a A -N 5280.0 44.0 CONNECTED 17.75 TOTAL DEMAND 10.80 30.0 ■ B -N 6830.0 56.9 DEMAND 10.80 TOTAL DESIGN 11.15 30.9 ■ C -N 5640.0 47.0 DESIGN 11.15 ALL LOADS EXISTING TO REMAIN UNLESS OTHERWISE NOTED NOTE 11 NEW LOAD - USE EXISTING CIRCUIT BREAKER PANEL, R1NHX OC DEVICE TYPE, Breaker ENCLOSURE, NEMA 1 MAINSCA), MLO CONTINUOUS(A), 800 LOCATION, DEVICE FAMILY, Bolt On MOUNTING, Surface WIRING, 3 -Phase 4 -Wire AIC RATING(A), 25000 FED FROM, PNL 1NHDX VOLTAGE, 480/277 FAULT CURRENT(A) 23161 CUBICLE SECONDARY CONNECTED DEMAND DESIGN DESIGN OC DEVICE EW CONSTRUCTION CONNECT TO EXIST. AT THIS POINT NO DESCRIPTION kVA kVA kVA AVE AMPS TYPE SIZE P NOTES 1 SPARE 0.00 0100 0100 0100 100 3 15 2 RAD X -RAY RM 1109 145.00 72.50 72.50 87.20 100 3 30 3 SPARE 0.00 0100 0100 0100 100 3 45 4 XFMR R 1 LN 1 13.48 9.05 9.05 10.89 80 3 75 5 RTU -R -1 33.24 33.24 33.24 39.98 100 3 6 RiNHI 15.01 15.01 18.76 22.57 125 3 112.5 7 OBI DISC 60.00 15.00 15.00 18.04 70 3 NOTE 1 8 SPACE 0100 0100 0100 0.00 0 3 150 9 SPACE 0100 0.00 0.00 0100 0 3 10 SPACE 0100 0.00 0.00 0100 0 3 225 11 SPACE 0.00 0100 0100 0100 0 3 12 SPACE 0100 0100 0.00 0100 0 3 300 13 SPACE 0.00 0.00 0.00 0.00 0 3 14 SPACE 0.00 0.00 0.00 0100 0 3 500 ALL CONNECTED KVA 3P AVE AMPS a PHASE TOTALS VA AMPS BUS TOTALS KVA TOTAL CONNECTED 263.88 317.4 0 A -N 87960.6 317.4 CONNECTED 263.88 TOTAL DEMAND 142.08 170.9 ■ B -N 87960.6 317.4 DEMAND 142.08 TOTAL DESIGN 142.08 170.9 9 C -N 87960.6 317.4 DESIGN 142.08 ALL LOADS EXISTING TO REMAIN UNLESS OTHERWISE NOTED NOTE is NEW LOAD - PROVIDE NEW BREAKER TO MATCH EXISTING. REFER TO COORDINATION STUDY ON SHEET E4.1 •' A 225KVA SIZE XFMR PRIMARY 3000A. BUS DUCT ry - TO FPL VAULT. - - N�ASB2 3000A - 27Ti 480V � NC 3000A 3PH, 4W C GFP NO : TQQQA T T T 1/1\ 1"T\ C 4 #50OMCM 1 #3G. - 311X. PROVIDE #iOAWG INSULATED GROUNDING CONDUCTOR r-- -1 I L17 BETWEEN THE GROUNDING TERMINAL OF THE PANELS R1 NHX I 800 - ----------------------- - - - - -- 350 I NORMAL NORMAL 7 BRANCH I BRANCH I I � 101911104MA 911 EXISTING CLINAC ....... jj�� 11 1611''I'Ll'i 1111 am DRY TYPE TRANSFORMER SCHEDULE SIZE KVA PRIMARY SECONDARY 480 VOLT 208 VOLT OVERCURRENT 480Y FEEDER 120/208Y FEEDER GROUNDING EW CONSTRUCTION CONNECT TO EXIST. AT THIS POINT AMPS AMPS OVERCURRENT SEE NOTE *1 SEE NOTE *2 SEE NOTE *2 SEE NOTE *3 T9 9 Ii 25 20A, 3P 30A, 3P 3 *12 & 1*12G - 314C. 4010 & 1 *10G - 314C. 1*8 - 3AC T15 15 18 42 30A, 3P 5OA, 3P 3 *10 & 1*IOG - 3/4C. 4 *8 & 1*1OG - 11C. 1 *8 - 3AC T30 30 36 83 6OA, 3P 100A, 3P 3 *6 & 10IOG - 3/4C. 403 & 108G - 1 1140. 1 *8 - 3AC T45 45 54 125 BOA, 3P 150A, 3P 3 *4 & 1 *8G - I'C. 4 *i /0 & 1 *6G - 2'C. 1 *6 - 3/4C T75 75 90 208 150A, 3P 25OA, 3P 3 *1/0 & 1*6G - 11/1C. 40250 KCMIL & 1 04G 1 *2 - 3AC /1C T112 112.5 135 313 200A, 3P 400A, 3P 3 *3/0 & 1 *6G - 2'C. 4 4 C KCMIL & 1 *3G 1 *1 /0 - 314 C. T150 150 181 417 300A, 3P 500A, 3P 3 *350 KCMIL & 1 *4G 8.250 KCMIL & 2 *2G 1 *1 /0 - 3/4C - 3'C. 2-21/1C. T225 225 271 625 400A. 3P 800A, 3P 3 *600 KCMIL & 1 *3G 1/1 8 *600 KCMIL & 2 *i /OG 1 *3/0 - 3/4C - 3 C. 2-4'C. T300 300 361 833 600A, 3P IOOOA, 3P 6 *350 KCMIL & 2 *1G 12 *400 KCMIL & 3 *2 /OG 1 *3/0 - 3/4C 2 -3'C. 3 -3'C. [500 500 602 1389 900A, 3P 1600A, 3P 9 *350 KCMIL & 3 *2 /OG 16 *600 KCMIL & 4 *4 /OG 1 *350KCMIL -1'C. 3 -31C. 4 -41C. TRANSFORMER NOTES: 1. SECONDARY OVERCURRENT PROTECTION SHALL BE LOCATED WiTHIN TEN (10) FEET OF THE TRANSFORMER SECONDARY TERMINALS EITHER IN A PANELBOARD (MAIN BREAKER) OR A INDIVIDUALLY MOUNTED CIRCUIT BREAKER. 2. ALL CONDUCTOR SIZES ARE BASED ON N.E.C. TABLE 310 -16 FOR COPPER CONDUCTORS. 3. TRANSFORMER BONDING JUMPER AND GROUNDING ELECTRODE CONDUCTOR (COPPER CONDUCTORS). BOND THE NEUTRAL OF THE TRANSFORMER SECONDARY TO THE TRANSFORMER CASE, WITH BONDING JUMPER. GROUND THE CASE OF THE TRANSFORMER WITH THE GROUNDING ELECTRODE CONDUCTOR TO THE NEAREST AVAILABLE EFFECTIVELY GROUNDED STRUCTURAL METAL MEMBER OF THE STRUCTUREQR THE NEAREST AVAILABLE EFFECTIVELY GROUNDED METAL WATER PIPE OR OTHER ELECTRODES AS S ECIFIED IN N.E.C. SECTIONS 250 -50 AND 250 -52 WHERE THE PRECEDING ELECTRODES ARE NOT AVAILABLE. 4.600 KCMIL CONDUCTORS SHALL BE COORDINATED WITH PROPER TERMINATION LUGS OR PROVIDED WITH MAC ADAPTERS AS REQUIRED TO COORDINATE WITH STANDARD BREAKER LUG SIZES. 1 2 3 4 4 M NORMAL DEMAND LOAD SUMMARY NMSB2 EXISTING LOAD: 1790.0 KVA NEW ADDED DEMAND LOAD: 15.0 KVA NEW TOTAL DEMAND LOAD: 1805.0 KVA 4#6,1#6G. IN 11C. 0 2° FLEXIBLE METAL CONDUIT NEW CONSTRUCTION LEGEND WJAI-Ml DESCRIPTION TO BE REMOVED EXISTING TO REMAIN EW CONSTRUCTION CONNECT TO EXIST. AT THIS POINT 5 6 BERMELLO AJAMIL & PARTNERS, INC. Architecture Engineering Planning Interior Design Landscape Architecture 2601 South Bayshore Drive 10th Floor Miami, Florida 33133 (305) 859 -2050 Fax (305) 860 -3700 7 SOUTH MIAMI HOSPITAL 6200 SW 73 STREET, MIAMI, FLORIDA 3314: MEP ENGINEER: Smith SS11 Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421 -1466 www.ssr- inc.com Firm. Certification - EB- 0000857 Alfred Esquivel PE - 45863 j Bruce W. Peek PE - 35901 Donald Netinho PE - 48454 Erik S. Walter PE - 63929 John E. Moulder PE -33200 Michael .L steward PE - 65701 Usman A.Tariq PE - 664M SSR JOB # 0732091.0 PROJECT SOUTH MIAMI HOSPITAL LINEAR . . O. OBI UPGRADE PROJECT ADDRESS: • 11 SW 73 STREET Florida 33143-4989 COMM. NO. SCALE: AS SHOWN DATE: 12 -20 -2007 DRAWN: CHECKED: A CADD FILE: DRAWING TITLE: ELECTRICAL RISER DIAGRAM SHEET NO. E3.1