08-1048-018A C n W W F- 0 11 16 DEVICES TO REMAIN TO NEW WORK PLAN DEVICES. ENLARGED CONTROL AREA - DEMOLITION - ELECTRICAL_ i 1L16 -36 12 iii *0'3" ENLARGED CONTROL AREA - NEW- WORK------ ELECTRICAJ 111111111 1 M I -I 1 KEYED NOTES: 0 48OV, 3- PHASE, 60A OBI MAIN CIRCUIT BREAKER DISCONNECT. PROVIDE GE #OB16OA48OV. ENSURE 42' CLEARANCE IS MAINTAINED IN FRONT OF PANEL PER NEC ART 110.26. 0 INTER CONNECT PANEL - PROVIDED BY VARIAN. 0 HF CABINET BY VARIAN 0 3.51X10' SURFACE ELECTRICAL DUCT WITH TWO PARTITIONS FROM IDP ON WALL TO CLINAC STAND ON FLOOR. ELECTRICAL DUCT SHALL BE WALKER WALLDUCT FOR HEALTHCARE. (WD10W350 SERIES). 0 PROVIDE 2 -4' CONDUIT FOR LOW VOLTAGE. TERMINATE ONE END TO WIRING ACCESS BEHIND CONTROL COUNTER AND THE OTHER END INTO THE SURFACE ELECTRICAL DUCT TO THE REAR OF THE CLINAC STAND. 0 EXISTING 1' SPARE CONDUIT TO BE USED FOR NEW 480V OBI FEEDER. 0 EXISTING SWITCHES AND DOOR PUSH BUTTON TO BE RELOCATED TO ACCOMODATE WORK TO WALL - REFER TO NEW WORK PLAN FOR NEW LOCATIONS. 0 NEW 'OBI IN USE' WARNING LIGHT. HEALTHCARE LIGHTING SYSTEMS #HSG301- XIU -R. PROVIDE RELAY AND CONNECT TO OBIPER VARIAN VENDOR DRAWINGS. CONNECT TO ADJACENT WARNING LIGHT'S 120V SOURCE. 0 CONNECT TO EXISTING SHUNT TRIP PUSHBUTTONS IN ROOM WITH 2 #12 IN1 /2C. �o REPLACE EXISTING RECEPTACLES WITH GFI TYPE. >i REMOVE EXISTING RECEPTACLE. REUSE EXISTING CIRCUIT FOR NEW DUPLEX RECEPTACLES IN NEW CASEWORK. REFER TO NEW WORK PLAN ON THIS SHEET. t2 RECONNECT TO EXISTING CIRCUIT PREVIOUSLY FEEDING DEMOLISHED RECEPTACLE. I I ti 4 3 SHOWN FOR REFERENCE ONLY - TYPICAL PARTIAL FLOOR PLAN - NEW WORK - ELECTRICAL_ 111111111 1 a I 4 5 5 CONSTRUCTION LEGEND DESCRIPTION rN,EW EXISTING TO BE REMOVED EXISTING TO REMAIN NEW CONSTRUCTION CONNECT TO EXIST. AT THIS POINT BERMELLO AJAMIL & PARTNERS, INC. Architecture Engineering Planning Interior Design Landscape Architecture 2601 South Bayshore Drive 10th Floor Miami, Florida 33133 (305) 859 -2050 Fax (305) 860 -3700 M SOUTH MIAMI HOSPITAL 6200 SW 73 STREET, MIAMI, FLORIDA. 33143 - r Smith Ss?t Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421 -1466 vvww.ssr- inc.com Firm Certification - E13- 0000857 Alfred Esquivel PE - 45863 Bruce W. Peek PE - 35901 Donald Netinho PE - 48454 Erik S. Walter PE -63929 John E. Moulder PE - 33200 Michael A. Steward PE - 65701 Usman A.Tariq PE - 66485 SSR JOB # 0732091,0 °a ». s v , 0NARKS N&I PROJECT SOUTH MLAA4I HOSPITAL LINEAR ACCELERATOR OBI UPGRADE ..O ADD 6200 SW 73 STREET Miami, Florida ..•. COMM. NO. SCALE: AS SHOWN DATE: 12 -20 -2007 DRAWN: CHECKED: A CADD FILE: DRAWING TITLE: PARTIAL FLOOR PLAN - NEW WORK ELECTRICAL SHEET NO. E2.1