08-1048-0160 A 10 C A W F_ 0 1 LEGEND SYMBOL DESCRIPTION MOUNTING HEIGHT LIGHTING �K? LIMOUNTINGHT GRRE - 'X` DENOTES FIXTURE TYPE - ABOVE FINISHED CEILING AFF TaPEADETERM NES AFG Q CRITICAL OR EQUIPMENT BRANCH LIGHT - `X` DENOTES BREAKER X e FIXTURE TYPE - TYPE DETERMINES MOUNTINGRE cd MEG SAFETY BRANCH LIGHT CIRCUIT � - ERMINES MOUNTING CLG CEILING MOUNTED DEVICE DISC NORMAL BRANCH LIGHT FIXTURE - 'X' DENOTES FIXTURE TYPE DIV EX ® TYPE DETERMINES MOUNTING F FRAME F/A CRITICAL OR EQUIPMENT BRANCH LIGHT FIXTURE - 'X' DENOTES FBO ®X® FLA FIXTURE TYPE - TYPE DETERMINES MOUNTING FU ®X® LIFE SAFETY BRANCH LIGHT FIXTURE - `X' DENOTES GROUND HP FIXTURE TYPE - TYPE DETERMINES MOUNTING K ej EXIT LIGHT, PROVIDE DIRECTIONAL ARROWS AS INDICATED MAIN CIRCUIT BREAKER MLO ON PLANS NEC NATIONAL ELECTRIC CODE a+ EXIT LIGHT, PROVIDE DIRECTIONAL ARROWS AS INDICATED OC OVER CURRENT OCP ON PLANS P SWITCHES S SINGLE POLE SWITCH - IVORY TOGGLE 3' -10' AFF TO CL SPECIAL MOUNTING HEIGHT TV SINGLE POLE SWITCH - RED TOGGLE AFF' 108 CL S3 THREE WAY SWITCH - IVORY TOGGLE 3' -10' AFF TO CL S4 FOUR WAY SWITCH - IVORY TOGGLE 31-10' AFF TO CL SD DIMMER SWITCH 3` -10® AFF TO CL SP SINGLE POLE SWITCH WITH PILOT LIGHT 3' -i0' AFF TO CL ST MOTOR RATED SWITCH WITH THERMAL OVERLOAD WEATHERPROOF DEVICE, NEMA 313 XFMR TRANSFORMER PUSH BUTTON SWITCH (MUSHROOM BUTTON) AFF P A TO CL POWER - RECEPTACLES 120V. DUPLEX RECEPTACLE - IVORY (REFER TO RECEPTACLE 1' -6' ABBREVIATIONS FOR EXCEPTIONS) AFF TO CL. 120V. DUPLEX RECEPTACLE - IVORY - SPECIAL MOUNTING HEIGHT AS NOTED OR (REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) SEE SPECS 120V. QUADPLEX RECEPTACLE - IVORY (REFER TO RECEPTACLE 1' -6' ABBREVIATIONS FOR EXCEPTIONS) AFF TO CL. 120V. QUADPLEX RECEPTACLE - IVORY - SPECIAL MOUNTING HEIGHT AS NOTED OR (REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) SEE SPECS /}- 120V. GFI RECEPTACLE (SPECIAL MOUNTING HEIGHT) AS NOTED OR SEE SPECS t- 120V. GFI RECEPTACLE AFF TO CL. ® WIREMOLD - LENGTH AS REQUIRED - EMERGENCY POWER ABOVE COUNTER ® WIREMOLD - LENGTH AS REQUIRED - NORMAL POWER ABOVE COUNTER TELEPHONE /DATA/TV .� TELEPHONE OUTLET WITH PLATE AFFV-6 CL. ,W WALL TELEPHONE OUTLET WITH PLATE AS NOTED OR SEE SPECS ,-- TELEPHONE OUTLET WITH PLATE (SPECIAL MOUNTING HEIGHT) AS NOTED OR SEE SPECS q COMBINATION DATA /TELEPHONE OUTLET WITH PLATE V -6' AFF TO CL. COMBINATION DATA /TELEPHONE OUTLET WITH PLATE AS NOTED OR (SPECIAL MOUNTING HEIGHT) SEE SPECS ® TV OUTLET FOR WALL OR CEILING AS NOTED OR SEE SPECS PAGING /INTERCOM PS HOSPITAL PAGING SPEAKER CEILING QM MONITOR DESK MOUNTED Iw INTERCOM WALL MODEL IF INTERCOM WALL MODEL (FLUSH MOUNTED) DS DOOR SWITCH MOUNTED IN DOOR JAMB ® DOOR RELEASE PUSH BUTTON NON - FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING /POLES) FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING /POLES) MOTOR CONNECTION Q JUNCTION BOX PANELBOARD - FLUSH MOUNTED PANELBOARD - SURFACE MOUNTED CONCEALED CONDUIT CONDUIT CONCEALED IN FLOOR OR BELOW GRADE HOMERUN TO PANELBOARD - NUMBER OF PHASE CONDUCTORS IN MINIMUM 314 CONDUIT UNLESS NOTED OTHERWISE NOTES: 1. ONE NEUTRAL CONDUCTOR, ALTHOUGH NOT INDICATED, SHALL BE INCLUDED - IN EACH RACEWAY UNLESS OTHERWISE NOTED. 2. ONE INSULATED GREEN GROUNDING CONDUCTOR, ALTHOUGH NOT INDICATED, SHALL BE INCLUDED IN EACH RACEWAY UNLESS OTHERWISE NOTED. 3. HOMERUNS TO PANELBOARDS SHALL HAVE A MAXIMUM OF THREE (3) PHASE CONDUCTORS (ONE PER PHASE)PLUS NEUTRAL AND GROUND CONDUCTORS IN EACH CONDUIT. 4. ALL CONDUCTORS SHALL BE #12 AWG UNLESS OTHERWISE NOTED. E F ABBREVIATIONS SYMBOL DESCRIPTION ABC ABOVE COUNTER ACLG ABOVE FINISHED CEILING AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE BKR BREAKER CB CIRCUIT BREAKER cd CANDELA CKT CIRCUIT CL CENTER LINE CLG CEILING MOUNTED DEVICE DISC DISCONNECT DIV DIVISION EX EXISTING F FRAME F/A FIRE ALARM FBO FURNISHED BY OTHERS FLA FULL LOAD AMPS FU FUSE G GROUND HP HORSE POWER K KILO MCB MAIN CIRCUIT BREAKER MLO MAIN LUGS ONLY NEC NATIONAL ELECTRIC CODE NIC NOT IN CONTRACT OC OVER CURRENT OCP OVER CURRENT PROTECTION P POLE PH PHASE SMH SPECIAL MOUNTING HEIGHT TV TELEVISION TYP TYPICAL UH UNIT HEATER UG UNDER GROUND ELECTRICAL UON UNLESS OTHERWISE NOTED V VOLT(S) VA VOLT - AMPS) W WATT(S), WIRE, WALL TELEPHONE OUTLET WP WEATHERPROOF DEVICE, NEMA 313 XFMR TRANSFORMER 4 A. REFER TO VENDOR DRAWINGS FOR ELECTRICAL REQUIREMENTS FOR ONBOARD IMAGING (OBI) EQUIPMENT INSTALLATION. PROVIDE ALL CIRCUIT BREAKERS, SWITCHES, PUSHBUTTONS, WIRE WAYS, LOAD CENTERS, ELECTRICAL DUCTS, CONDUIT, WIRING, BACK BOXES, ELECTRICAL DEVICES, AND GROUNDING AS REQUIRED BY THE VENDOR. COORDINATE ALL WORK WITH VENDOR. PROVIDE ALL FINAL TERMINATIONS AS DIRECTED BY VENDOR. PERFORM ALL WORK IN ACCORDANCE WITH NEC AND NFPA 99. B. CONTRACTOR TO OBTAIN A LISTING FROM THE MANUFACTURER OF ALL INTERCONNECTING CABLES IDENTIFYING THE USE, TYPE OF CABLE, AND CLASS OF THE SYSTEM (I.E., POWER, COMMUNICATION, CLASS 1, CLASS 2, ETC.) FOR FIELD VERIFICATION ON THE SEPARATION OF THE DIFFERENT WIRING SYSTEMS. C. CONTRACTOR IS RESPONSIBLE FOR ALL REQUIREMENTS AND DETAILS IN THE VENDOR DRAWINGS. D. ALL EQUIPMENT MUST BE BONDED TO THE RACEWAY SYSTEM. WHERE FLEXIBILITY IS REQUIRED, FLEXIBLE METAL CONDUIT SHALL BE USED AS PERMITTED BY THE NEC. WHERE THE DEGREE OF FLEXIBILITY DOES NOT ALLOW THE USE OF FLEXIBLE METAL CONDUIT, A MULTISTRANDED INSULATED COPPER CONDUCTOR MAY BE UTILIZEDTO PROVIDE RACEWAY CONTINUITY FROM THE BEGINNING TO THE END. E. CONTRACTOR SHALL COORDINATE WITH VENDOR AND PURCHASE ELECTRICAL DUCT WITH SHEET METAL DIVIDERS TO PROVIDE SEPARATION FOR THE FOLLOWING CABLE TYPES: (1) 24 VOLT (2) 300 VOLTS AND LESS (3) 301 -600 VOLTS (4) HIGH TENSION X -RAY CABLES (5) VIDEO CABLES F. ALL SECTIONS OF RACEWAY AND CONDUIT SHALL BE GROUNDED WITH AN INDEPENDENT #6 AWG GREEN WIRE THAT IS TO BE ATTACHED USING SOLDERLESS LUGS. ALL CEILING MOUNTED STRUCTURAL SUPPORT MEMBERS AND CEILING PLATES SHALL ALSO BE GROUNDED. ALL GROUNDING CONNECTIONS, TERMINALS, ETC. SHALL BE INSTALLED IN A MANNER TO PROVIDE ACCESSIBILITY FOR INSPECTION, MAINTENANCE, REPAIRS, ETC. REFER TO VENDOR DRAWINGS FOR ADDITIONAL GROUNDING REQUIREMENTS. G. COORDINATE WITH ARCHITECT AND VENDOR, THE EXACT LOCATIONS OF ALL ELECTRICAL EQUIPMENT FOR THE SPECIAL PROCEDURES ROOM, EQUIPMENT ROOM AND CONTROL ROOM. COORDINATE ALL MOUNTING HEIGHTS PRIOR TO INSTALLATION. H. TEST THE EFFECTIVENESS OF THE GROUNDING SYSTEM BY VOLTAGE AND IMPEDANCE MEASUREMENTS AS REQUIRED BY NFPA 99, SECTION 4.3.3. RECORD THE RESULTS AND MAKE THEM AVAILABLE TO THE AUTHORITY HAVING JURISDICTION AT THE TIME OF FINAL INSPECTION BY THESE AUTHORITIES. METER USED SHOULD HAVE BEEN CALIBRATED WITHIN THE LAST 12 MONTHS AND THIS METER SHALL BE AVAILABLE AT TIME OF FINAL AHCA INSPECTION. I. CONTRACTOR SHALL OBTAIN VENDOR INSTALLATION DRAWING PRIOR TO THE START OF ANY WORK. PROVIDE SURGE PROTECTION FOR ALL LOW VOLTAGE AND POWER CONNECTIONS TO ALL ELECTRONIC EQUIPMENT IN CRITICAL CARE AREAS AND LIFE SAFETY SYSTEMS AND EQUIPMENT SUCH AS FIRE ALARM, NURSE CALL AND OTHER CRITICAL SYSTEMS. PROTECTION SHALL BE IN ACCORDANCE WITH APPROPRIATE IEEE STANDARDS FOR THE TYPE OF EQUIPMENT PROTECTED. 3 4 5 0151 ... 111''i... IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REMOVE EXISTING EQUIPMENT AS REQUIRED TO ACCOMPLISH THE NEW WORK AS SHOWN OR REASONABLY IMPLIED-.--- THE ­ CONTRACTOR CONTRACTOR SHALL REFER TO THE NEW ARCHI TECTURAL, PLUMBI NG, FI RE P ; a CTI ONP MECHANI CAL AND ELECTRI CAL WORK SHOWN ON THE OTHER DRAWI NGS OF THI S. -SET TQ_ _ DETERMINE THE EXTENT OF DEMOLITION REQUIRED. WHEN REMOVING ELECTRICAL EQUIPMENT AND SYSTEMS, ALL PRECAUTIONS SHALL BE TAKEN TO PREVENT STRUCTURAL DAMAGE TO THE BUILDING. THE CONTRACTOR SHALL COORDINATE INSTALLATION OF ANY STRUCTURAL SUPPORTS REQUIRED, TEMPORARY OR PERMANENT. THE CONTRACTOR SHALL EXERCISE CARE SO THAT ONLY THAT CONSTRUCTION INDICATED OR REASONABLY IMPLIED TO BE REMOVED SHALL BE DEMOLISHED. THE EXISTING CONSTRUCTION TO REMAIN SHALL BE LEFT INTACT AND UNDAMAGED. THE CONTRACTOR SHALL PROTECT ALL ADJACENT SURFACES AND MATERIALS AS REQUIRED TO PREVENT DAMAGE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL DEMOLITION AND CONSTRUCTION DEBRIS GENERATED FROM WORK ON ALL FLOORS. TAKING CARE TO PREVENT EXCESSIVE LOADING OF FLOOR ASSEMBLIES. THE CONTRACTOR SHALL MAINTAIN CONTINUITY OF CIRCUITS WHERE EXISTING EQUIPMENT IS TO BE REMOVED AND DOWN STREAM DEVICES MAY BE EFFECTED. THE CONTRACTOR SHALL COORDINATE ALL POWER INTERRUPTIONS WITH OWNER. SEE SPECIFICATIONS. WHEN EXISTING ELEMENTS OF ELECTRICAL EQUIPMENT AND SYSTEMS ARE REMOVED, ALL REMAI NI NG OPENI NGS I N THE SLAB AND WALLS SHALL BE FI LLED I N BY THE CONTRACTOR. REMOVE ALL MISCELLANEOUS FIXTURES AND EQUIPMENT RETAINING ITEMS TO BE IDENTIFIED FOR SALVAGE AND STORAGE AT THE DIRECTION OF THE OWNER. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS DURING DEMOLITION AND CONSTRUCTION TO MAINTAIN THE INTEGRITY AND OPERATION OF EXISTING LIFE SAFETY AND EMERGENCY EGRESS EQUIPMENT. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS DURING DEMOLITION AND CONSTRUCTION TO MAINTAIN ACCESS TO ALL MEANS OF EGRESS CORRIDORS, DOORWAYS AND STAIRS. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS DURING DEMOLITION AND CONSTRUCTION TO PERMIT EFFECTED AREAS TO CONTINUE TO FUNCTION TO THE GREATEST EXTENT POSSIBLE. THIS EFFORT SHALL INCLUDE SCHEDULED COORDINATION WITH OWNER OF ELECTRICAL SHUTDOWNS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL FLUORESCENT AND HID TYPE LAMPS AND PROPER DISPOSAL OF SAID LAMPS AND SHALL PROVIDE VERIFICATION OF LAMP DISPOSAL TO THE OWNER UPON REQUEST. REMOVE ALL LIGHTING FIXTURES, RECEPTACLES AND DEVICES IN THE AREA OF DEMOLITION AND PULL ALL CIRCUITS BACK TO NEXT ACTIVE DEVICE OR SOURCE OF POWER PROVIDE PANEL SCHEDULES, TO THE ENGINEER, INDICATING THE CIRCUITS MADE SPARE BY DEMOLITION AND THE EXISTING CIRCUITS THAT REMAIN ACTIVE. IT SHALL BE THE RESPONSIBILITY OF THE CONSTRUCTION MANAGER (CM), GENERAL CONTRACTOR (GC), AND THE SUB- CONTRACTORS (SC) TO STUDY ALL THE DRAWINGS AND DETAILS SO THAT THE INSTALLATION OF ALL NEW WORK CAN BE FULLY COORDINATED. THE CM, GC, AND SC SHALL VISIT THE SITE, INCLUDING DOING AN ABOVE CEILING INSPECTION, DURING BIDDING TO SATISFY HIM /HER SELF THAT ALL PROVISIONS HAVE BEEN MADE FOR ALL ASPECTS OF THIS PROJECT. IF DISCREPANCIES EXIST BETWEEN DRAWINGS AND /OR SITE CONDITIONS, THE CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR IN WRITING PRIOR TO BID DUE DATE. FAILURE TO DO SO WILL NOT BE ALLOWED ON A BASIS FOR ADDITIONAL COMPENSATION TO CORRECT A DIFFICULTY OF DIFFERENCE FROM CONDITIONS INFERRED OR INDICATED ON THE DRAWINGS. F1 ELECTRICAL DRAWING INDEX NO. SHEET TITLE EO.1 LEGEND, ABBREVIATIONS & DRAWING INDEX SYSTEMS RESPONSIBILTY SCHEDULE SYSTEM PARTIAL FLOOR PLAN - NEW WORK - ELECTRICAL INTERIOR CABLE INTERIOR CABLE E4.1 EXTENT OF E5.1 EQUIPMENT EQUIPMENT FURNISHED BY: INSTALLED BY: CONDUIT: FURNISHED BY: INSTALLED BY: NOTES: TELEPHONE /DATA VENDOR VENDOR 0 VENDOR VENDOR NOTES: EC= ELECTRICAL CONTRACTOR VENDOR = OWNER /OWNER'S VENDOR ALL OPEN WIRING ABOVE CEILING SHALL BE PLENUM RATED O TO ABOVE ACCESSIBLE CEILING SPACE IN CORRIDOR, TERMINATE WITH PLASTIC BUSHING. iD VENDOR CONTRACTED DIRECTLY BY OWNER. F1 ELECTRICAL DRAWING INDEX NO. SHEET TITLE EO.1 LEGEND, ABBREVIATIONS & DRAWING INDEX E1.1 PARTIAL FLOOR PLAN - LOCATION REFERENCE PLAN E2.1 PARTIAL FLOOR PLAN - NEW WORK - ELECTRICAL E3.1 ELECTRICAL RISER DIAGRAM E4.1 ELECTRICAL STUDIES E5.1 ELECTRICAL SPECIFICATIONS no E BERMELLO AJAMIL & PARTNERS, INC. Architecture Engineering Planning Interior Design Landscape Architecture 2601 South Bayshore Drive 10th Floor Miami, Florida 33133 (305) 859 -2050 Fax (305) 860 -3700 SOUTH MIAMI HOSPITAL 6200 SW 73 STREET, MIAMI, FLORIDA 33143 MEP ENGINEER: Smith SR Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421 -1466 www.ssr- inc.com Firm Certification - EB- 0000857 Alfred Esquivel PE - 45863 Bruce W. Peek PE - 35901 Donald Netinho PE - 48454 Erik S. Walter PE -63929 John E. Moulder PE - 33200 Michael A. Steward PE - 65701 Usman A.Tariq PE - 66485 SSR JOB # 0732091.0 PROJECT SOUTH • ACCELERATOR LINEAR ORI UPGRADE PROJECT ,rr. 6200 SW 73 STREET Florida KEY PLAN COMM. • O, DATE: 00 DRAWN: CHECKED: Arr DRAWING ABBREVIATIONS DRAWING SHEET • 1 .. C,- Fllilt d u PROJECT SOUTH • ACCELERATOR LINEAR ORI UPGRADE PROJECT ,rr. 6200 SW 73 STREET Florida KEY PLAN COMM. • O, DATE: 00 DRAWN: CHECKED: Arr DRAWING ABBREVIATIONS DRAWING SHEET • 1