Loading...
08-1048-00410.1TCD SCAL CORRIDOR Mal •- r • r PHYSICIST LOCKER LOCKER OFFICE TREATMENT RM. RM. PLANNING DARK ROOM VESTIBULE CORRIDOR CONTROLAREA I II 1 1 1 1 1 1 1 1 1 1 q q 1 g 1 1 A A N q 11 II A I N N I M A I 1 1 N g I N 1 1 N I g 1 II JI 1 1 1 1 1 1 1 1 1 1 1 1 1 g 1 1 1 A N N II 11 1 1 g N 1 1 1 1 1 1 1 N I N 1 1 1 / A A 11 :11:1111118 1 1 1 1 g q 1 1 1 1 q/ N N II 1 1 A l l A A I I A 1 N 111 I�L1Jl.L1Jl..L1JLLJI JLLJ11 L91�9�1 Tr II H II N II II ------- ll ---------- --- 5'-3® KAU FRONT VIEW 1 � O !Q - I 1 N 1 t 1 1 t 11 I N N 1 1 1 1 II 1 1 N I I I 1 II 01011 LIFT a�DC� 3 4ig SIMULATOR GENERAL NOTES A. ALL ITEMS NOT MARKED TO BE DEMOLISHED ARE EXISTING TO REMAIN. CONTRACTOR RESPONSIBLE FOR PRESERVING THE EXISTING CONDITIONS OF THESE ITEMS, SEE GENERAL DEMOLITION NOTES @ INDEX SHEET A001 B. THE CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO ANY WORK. NOTIFY ARCHITECT IN WRITING FOR CLARIFICATION. C. THE CONTRACTOR SHALL COORDINATE WITH OWNER REPRESENTATIVE TEMPORARY STORAGE OF ANY TYPE OF EQUIPMENT, FURNITURE, ETC., TO BE RELOCATED PRIOR TO ANY WORK. D. REFER TO MEP DRAWINGS FOR MECHANICAL, ELECTRICAL AND PLUMBING DEMOLITION, REPLACEMENTS, RELOCATIONS ANDI ADDITIONS. E. PATCH ALL HOLES IN EXISTING CONCRETE FLOOR WHERE MECHANICAL, ELECTRICAL OR OTHER PENETRATIONS HAVE BEEN DEMOLISHED, FIRE RATING MUST BE MAINTAINED. HOLES IN CONCRETE TO BE FILLED WITH CONCRETE. V PATCH, REPAIR AND LEVEL FLOOR TO RECEIVE NEW FLOOR FINISH. REFER TO FINISH SCHEDULE. G. EQUIPMENT SHOWN ON THIS PLAN IS FOR LOCATION ONLY — COORDINATE WITH OWNER FOR FINAL LOCATION. UNDERSIDE OF EXIST. STRUCTURE UNDERSIDE OF EXIST. STRUCTURE OL05E OPEN DUCT5 100 MIL POLY. — SEAL 4 DUCT TAPE CLOSE CEILING SPACE 100 MIL POLY. 5E.AL. ALL JOINTS PENETRATION 4 PERIMETER WITH DUCT TAPE ELEV. BOTTOM OF CLNG. {FIELD VERIFY DIM.} UNDERSIDE OF EXIST. FINISH CEILING Jq -q ♦ ♦ f- - � - J , i►','�' \ TEMPORARY PARTITION DEMOLITION NOTES M 1 EXISTING FIXED FURNITURE TO BE PARTIALLY REMOVED, REFER TO DRAWING 2/A101 FOR SPECIFICS, 2 FOR REMOVAL OR RELOCATION OF ANY MECHANICAL & ELECTRICAL WIRING /EQUIP, REFER TO ENGINEER DRAWINGS. EXISTING SHELVES/DIVIDERS TO BE REMOVED WITHOUT DAMAGING ADJACENT FURNITURE. EXISTING FIXED FURNITURE TO BE REMOVED AND RELOCATED ACCORDING TO DRAWING 31A101. 0 ��� EXISTING MEDICAL EQUIPMENT TO BE REMOVED AND RETURNED TO OWNER. (6 } ENCLOSE PERIMETER DURING CONSTRUCTION WITH VISQUEEN aEXISTING EMERGENCY OUTLET AND PUSH PLATE TO BE RELOCATED I 41a BERMELLO AJAMIL I& PARTNERS, INC. Architecture Engineering Planning _ - - - Interior Design Landscape Architecture 2601 South Bayshore Drive 10th Floor Miami, Florida 33133 (305) 859 -2050 Fax (305) 860 -3700 LEGEND =OFWORK SOUTH MIAMI HOSPITAL 6200 SW 73 STREET, MIAMI, FLORIDA 33143 MEP ENGINEER: 6N*jSR Smith, Seckman, Reid, Inc. CtJNSUL.'TING ENGINEER 600 West Hillsboro, Suite 300 Deerfield Beach, Florida 33441 Phone(954)421 -1260 Fax(954)421 -1466 4� F� I r. a. e PROJECT NAME: SOUTH MIAMI HOSPITAL LINEAR ACCELERATOR OBI UPGRADE PROJECT ADDRESS: 6200 SW 73 STREET Miami, Florida 33143 -4989 COMM. NO. 40045.100 SCALE: AS SHOWN DATE: 12 -20 -2007 DRAWN: CHECKED: CADD FILE: H:Institutioml DRAWING TITLE: FIRST FLOOR DEMOLITION PLAN SHEET NO. . ul WALL OR DOOR ASSEMBLY TO REMAIN [- __- -- _____; WALL /ITEM TO BE DEMOLISHED 1 REFERRED TO DEMOLITION NOTE ACTION TO BE APPLIED X NOTE ON THIS DRAWING z� DOOR NUMBER �-� WALL TYPE GYPSUM WALLBOARD SOUTH MIAMI HOSPITAL 6200 SW 73 STREET, MIAMI, FLORIDA 33143 MEP ENGINEER: 6N*jSR Smith, Seckman, Reid, Inc. CtJNSUL.'TING ENGINEER 600 West Hillsboro, Suite 300 Deerfield Beach, Florida 33441 Phone(954)421 -1260 Fax(954)421 -1466 4� F� I r. a. e PROJECT NAME: SOUTH MIAMI HOSPITAL LINEAR ACCELERATOR OBI UPGRADE PROJECT ADDRESS: 6200 SW 73 STREET Miami, Florida 33143 -4989 COMM. NO. 40045.100 SCALE: AS SHOWN DATE: 12 -20 -2007 DRAWN: CHECKED: CADD FILE: H:Institutioml DRAWING TITLE: FIRST FLOOR DEMOLITION PLAN SHEET NO. . ul