07-323-011LEGEND SYMBOL DESCRIPTION MOUNTING HEIGHT LIGHTING n X�O GHT - TYPE DETERMINES IMOUNT NGURE - 'X' DENOTES FIXTURE TYPE ABOVE FINISHED FLOOR e EQUIPMENT RE - 'X` DENOTES FIXTU E TYPE T PE DETERMINES MOUNTING 80' AFF TO BOTTOM OF LENS O SAFETY BRANCH LIGHT TE FIXTURE - 'X' DENOTES FIXTURE TYPE - TYPE DE MINES MOUNTING 3' -10' AFF TO CL EX ® NORMAL BRANCH LIGHT FIXTURE - 'X' DENOTES FIXTURE TYPE TYPE DETERMINES MOUNTING Ell ME= CIRCUIT CRITICAL OR EQUIPMENT BRANCH LIGHT FIXTURE - 'X' DENOTES FIXTURE TYPE - TYPE DETERMINES MOUNTING FIRE SMOKE DAMPER ®X® LIFE SAFETY BRANCH LIGHT FIXTURE - 'X' DENOTES FIXTURE TYPE - TYPE DETERMINES MOUNTING FIRE ALARM SMOKE DETECTOR CEILING OH EXIT LIGHT, PROVIDE DIRECTIONAL ARROWS AS INDICATED ON PLANS EX SWITCHES S SINGLE POLE SWITCH - IVORY TOGGLE 3' -10' AFF TO CL DUCT SMOKE DETECTOR - RETURN DUCT FBO SINGLE POLE SWITCH - RED TOGGLE 3' -10' AFF TO CL S2 DOUBLE POLE SWITCH - CENTER OFF 3' -10' AFF TO CL S3 THREE WAY SWITCH - IVORY TOGGLE 3' -10' AFF TO CL S4 FOUR WAY SWITCH - IVORY TOGGLE 3' -10" AFF TO CL SD DIMMER SWITCH 31-10' AFF TO CL ST MOTOR RATED SWITCH WITH THERMAL OVERLOAD FIRE ALARM TRANSPONDER CABINET EPO FIRE ALARM RELAY POWER - RECECPTACLES TELEPHONE /DATA 120V. DUPLEX RECEPTACLE - IVORY (REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) V -6' AFF TO CL 41-61 AFF TO CL 120V. DUPLEX RECEPTACLE - IVORY - SPECIAL MOUNTING HEIGHT (REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) AS NOTED OR SEE SPECS V -6' AFF TO CL 120V. QUADPLEX RECEPTACLE - IVORY (REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) V -6' AFF TO CL AS NOTED SEE SPECS. 120V. QUADPLEX RECEPTACLE - IVORY - SPECIAL MOUNTING HEIGHT (REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) AS NOTED OR SEE SPECS 0- SPECIAL RECEPTACLE (TYPE AS NOTED) AS NOTED OR SEE SPECS I}- 120V. GFI RECEPTACLE (SPECIAL MOUNTING HEIGHT) AS NOTED OR SEE SPECS Q- 120V. GFI RECEPTACLE I' -6' AFF TO CL ® WIREMOLD 4000 SERIES INDICATED - EMERGENCY POWER Q JUNCTION BOX NURSE CALL CAPPED CONDUIT EMERGENCY PULL CORD STATION (PULL CORD TO EXTEND WITHIN 2' A.F.F.) �E EMERGENCY PUSH BUTTON STATION f�+ sP SINGLE PATIENT STATION CEKh RK RECEPTACLE PLUG KIT FOR INTERFACE CONNECTION OF NURSE CALL TO SIDE -COM VFD Ce CODE BLUE STATION Q STAFF STATION = d DUTY STATION ® DOME LIGHT CEILING Q INTERSECTION ZONE LIGHT CEILING NM NURSE CALL MASTER STATION FN CT NURSE CALL CONTROLLER Q MONITOR DESK MOUNTED IW INTERCOM WALL MODEL ID INTERCOM DESK MODEL IF INTERCOM WALL MODEL (FLUSH MOUNTED) SOUND SYSTEM Ps CEILING PAGING SPEAKER CEILING MTD. Ps WALL PAGING SPEAKER WALL MTD. 88' AFF ❑v VOLUME CONTROL 461AFF LEGEND SYMBOL DESCRIPTION MOUNTING HEIGHT FIRE ALARM ,F FIREFIGHTER'S TELEPHONE JACK ABOVE FINISHED FLOOR AFG FIRE ALARM VISUAL STATION - LIGHT ONLY 80' AFF TO BOTTOM OF LENS Q FIRE ALARM MANUAL PULL STATION 3' -10' AFF TO CL F� FIRE ALARM AUDIBLE /VISUAL DEVICE 80' AFF TO BOTTOM OF LENS Ell FIRE ALARM HORN CIRCUIT FFS-51 FIRE SMOKE DAMPER CLG Q FIRE ALARM SMOKE DETECTOR CEILING OH HEAT DETECTOR EX ®S DUCT SMOKE DETECTOR - SUPPLY DUCT FRAME FOR DUCT SMOKE DETECTOR - RETURN DUCT FBO RI SMOKE DETECTOR REMOTE INDICATOR FULL LOAD AMPS FS-A-11 SMOKE DETECTOR ALARM REMOTE INDICATOR /TEST SWITCH FU Q SPRINKLER SYSTEM VALVE STATUS SWITCH GROUND Fs SPRINKLER SYSTEM FLOW SWITCH FACP FIRE ALARM CONTROL PANEL FATC FIRE ALARM TRANSPONDER CABINET ® FIRE ALARM RELAY TELEPHONE /DATA *W WALL TELEPHONE OUTLET WITH PLATE 41-61 AFF TO CL fQ COMBINATION DATA /TELEPHONE OUTLET WITH PLATE V -6' AFF TO CL �. COMBINATION DATA /TELEPHONE OUTLET WITH PLATE (SPECIAL MOUNTING HEIGHT) AS NOTED SEE SPECS. Q DATA OUTLET WITH PLATE 1' -6' AFF TO CL TELEPHONE OUTLET WITH PLATE 1 AFF TO CL CABLE /MAN SYSTEM ® MATV OUTLET FOR WALL MOUNTED TV (ANTENNA, & REMOTE CONTROL SEE MANUFACTURERS DETAIL) CO%I:D. WITH ARCHITECTURAL MISCELLANEUOS CONDUIT CONCEALED CONDUIT BELOW GRADE - ON SITE CAPPED CONDUIT NON- FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING /POLES) f�+ FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING /POLES) CEKh COMBINATION MOTOR STARTER VFD VARIABLE FREQUENCY DRIVE - COORD. WITH DIV. 15. MOTOR CONNECTION. 'X' INDICATES HORSEPOWER - REFER TO MOTOR BRANCH CIRCUIT SCHEDULES FOR WIRING REQUIREMENTS. = PANELBOARD - FLUSH MOUNTED PANELBOARD - SURFACE MOUNTED MGAP MED GAS ALARM PANEL NOTES: 1. HOMERUN TO PANELBOARD - NUMBER OF PHASE CONDUCTORS IN MINIMUM 314 CONDUIT UNLESS NOTED OTHERWISE. ONE INSULATED GREEN GROUNDING CONDUCTOR, ALTHOUGH NOT INDICATED, SHALL BE INCLUDED IN EACH RACEWAY UNLESS OTHERWISE NOTED. 2. ONE NEUTRAL CONDUCTOR, ALTHOUGH NOT INDICATED, SHALL BE INCLUDED IN EACH RACEWAY UNLESS OTHERWISE NOTED. 3. HOMERUNS TO PANELBOARDS SHALL HAVE A MAXIMUM OF THREE (3) PHASE CONDUCTORS (ONE PER PHASE) PLUS NEUTRAL AND GROUND CONDUCTORS IN EACH CONDUIT. 4-ALL CONDUCTORS SHALL BE #12 AWG UNLESS OTHERWISE NOTED. ABBREVIATIONS ABC ABOVE COUNTER AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE BKR BREAKER C RED- EMERGENCY POWER CB CIRCUIT BREAKER cd CANDELA CKT CIRCUIT CL CENTER LINE CLG CEILING DISC DISCONNECT DIV DIVISION EX EXISTING F FRAME F/A FIRE ALARM FBO FURNISHED BY OTHERS FLA FULL LOAD AMPS FPL FLORIDA POWER & LIGHT FU FUSE G GROUND HP HORSE POWER ABBREVIATIONS K KILO MCB MAIN CIRCUIT BREAKER MLO MAIN LUGS ONLY NEC NATIONAL ELECTRIC CODE NIC NOT IN CONTRACT OC OVER CURRENT OCP OVER CURRENT PROTECTION P POLE PH PHASE REF REFRIGERATOR SMH SPECIAL MOUNTING HEIGHT TV TELEVISION TYP TYPICAL UG UNDER GROUND ELECTRICAL LION UNLESS OTHERWISE NOTED V VOLT(S) VA VOLT - AMPS) W WATT(S), WIRE, WALL TELEPHONE OUTLET & PLATE (SEE SPECS) WCR WITHSTAND /CLOSE -ON RATING WP WEATHERPROOF DEVICE, NEMA 3R XFMR TRANSFORMER BERMELLO AJAMIL & PARTNERS, INC. Architecture Engineering Planning Interior Design Landscape Architecture 2601 South Bayshore Drive 10th Floor Miami, Florida33133 (305) 859 -2050 Fax (305) 860 -3700 MEP ENGINEER: MEP ENGINEER INFORMATION Smith SS11 Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421 -1466 www.ssr - inc.com Firm Certification - EB- 0000857 Alfred Eequivel PE - 45863 Bruce W. Peek PE - 35901 Donald Netinho PE-48454. John E. Moulder PE - 33200 Nelson B. Long PE - 52294 SSR JOB # 0632053.0 'f i�10 45 � rf f R� true. nm8�� REVISIONS: PROJECT NAME: SOUTH MIAMI HOSPITAL P -TUBE STATION NIGU - 53RD FLOOR PROJECT ADDRESS: 7400 S.W. 62nd Ave. South Miami, Florida 33143 COMM. NO. SCALE: DATE: 11 -08-06 DRAWN: HS CHECKED: AE CADD FILE: DRAWING TITLE: DRAWING INDEX, LEGEND, AND SCHEDULES SHEET NO. E -0.1 . ELECTRICAL INDEX SHEET N0. SHEET TITLE E -0.1 DRAWING INDEX, LEGEND, AND SCHEDULES E -2.1 NICU THIRD FLOOR PARTIAL FLOOR PLAN - NEW WORK - POWER E -3.1 PARTIAL ELECTRICAL DISTRIBUTION DIAGRAMS E -4.1 ELECTRICAL SPECIFICATIONS BERMELLO AJAMIL & PARTNERS, INC. Architecture Engineering Planning Interior Design Landscape Architecture 2601 South Bayshore Drive 10th Floor Miami, Florida33133 (305) 859 -2050 Fax (305) 860 -3700 MEP ENGINEER: MEP ENGINEER INFORMATION Smith SS11 Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421 -1466 www.ssr - inc.com Firm Certification - EB- 0000857 Alfred Eequivel PE - 45863 Bruce W. Peek PE - 35901 Donald Netinho PE-48454. John E. Moulder PE - 33200 Nelson B. Long PE - 52294 SSR JOB # 0632053.0 'f i�10 45 � rf f R� true. nm8�� REVISIONS: PROJECT NAME: SOUTH MIAMI HOSPITAL P -TUBE STATION NIGU - 53RD FLOOR PROJECT ADDRESS: 7400 S.W. 62nd Ave. South Miami, Florida 33143 COMM. NO. SCALE: DATE: 11 -08-06 DRAWN: HS CHECKED: AE CADD FILE: DRAWING TITLE: DRAWING INDEX, LEGEND, AND SCHEDULES SHEET NO. E -0.1 .