Loading...
07-323-007E S aKAaO f�11L RECEPTI ON 0 i i M • • • • • ►' •I • a M5 DETAILS SCALE: 6" = 1' -0" 1/4" CAP TOP ,/t6" CEILING P BOTTOM _ 0 Lil 0 a _ F- L1J 0 Gjry _LLI rr' 0 L'j U �z L.1i > Of ry ry 1 FLOOR SURFACE MOUNTED GUARD AT FULL HEIGHT ELEVATION GENERAL NOTES—- wa ry m_ A._ CONTRACTOR TO RECEIVE VEi4DO - DRAWk1C;'S= FROM SWISSLOG INDICATING ROUTING PLAN. - CONTACT INFO: Damian L. Slaughter Office: 001 - 727 - 895 -6356 Fax: 001 -303- 307 -3790 rt Ty e -mail: damian.slaughter(a)_swissiog -Com" B._ DIMENSIONS SHOWN ARE APPROXIMATE. THE CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO BIDDING AND PRIOR TO START ANY NEW WORK. C.- ADJUST CEILING MOUNTED DEVICES, LIGHT FIXTURES, HVAC SUPPLY AND RETURN, ETC. AS NECESSARY IN FIELD. D._ CONTRACTOR TO PATCH AND REPAIR AS NECESSARY, ALL FINISHES MUST MATCH TO EXISTING. NOTE THIS DRAWING 1 EXISTING WALLS TO REMAIN 2 NEW P -TUBE STATION. TO BE INSTALLED AS PER MANUFACTURER SPECIFICATIONS. DRYWALL PARTITION ABOVE AND BELOW STATION, CONTRACTOR TO PAINT TO MATCH EXISTING, AND INSTALL RUBBER BASE TO MATCH EXISTING. 3 UNDERSIDE OF STRUCTURE. 4 FINISH CEILING. SEE FINISH SCHEDULE. 5 FINISH FLOOR. SEE FINISH SCHEDULE. 6 CONTINUOUS SEALANT EACH SIDE. 7 3%" 20 GA. METAL CHANNEL RUNNER. 8 5/8" GYPSUM BOARD. 9 CONTINUOUS FIRE STOP. 1 d 3 5/8" 20GA METAL STUDS @ 16" O.C. 11 3 1/2" SOUND ATTENUATION BLANKET STC 45 -49 <0> 1X" DEEP HORIZ BRACING CHANNEL AT MID -SPAN OF WALL OR MAX 6' -0" SPACING, CONTRACTOR TO PATCH AND REPAIR CEILING TILES AS NECESSARY. 14 CORNER GUARD. ACROVYN SSM -20 FLOOR TO CEILING. FINISH TO BE SELECTED BY ARCHITECT. 1 #6x1 5/8" BUGLE HD DRYWALL SCREW. 16 % GYPSUM BOARD 1 CONTINUOUS VINYL RETAINER. 18 HIGH IMPACT VINYL ACRYLIC EXTRUSION. 19 STEEL STUD 'q 'V zy uiiLs_ ,.f4e`.,,�`8 NiF ri 10I FLOOR PLAN LEGEND ,.A HATCH DEPICTS AREA OUT OF SCOPE OF WORK F NEW PREFAB WALL -1 EXISTING WALLS <8> NOTE - WORK STATION NUMBER DATA/VOICE WITH GROMMET RECEPTACLE �❑1 WALL TYPE BERMELLO AJAMIL &1 PARTNERS, INC. Architecture Engineering Planning Interior Design Landscape Architecture 2601 South Bayshore Drive 10th Floor Miami, Florida 33133 (305) 859 -2050 Fax (305) 860 -3700 MEP ENGINEER: MEPENGINEER INFORMATION Smith, Seckman, Reid, Inc. cil C) av 11 I-IT =NGII`�T =. 600 West Hillsboro, Suite 300 Deerfield Beach, Florida 33441 Phone(954)421 -1260 Fax(954)421 -1466 �p N h►O A* � ° V REVISIONS: PROJECT NAME: SOUTH MIAMI HOSPITAL P -TUBE STATION NICU- 3RD FLOOR PROJECT ADDRESS: 7400 S.W. 62nd Ave. C.,.. 0, AA:., , T'1. 4A4 111 Al SCALE: DATE: 09 -I5-2006 DRAWN: AZ(FG CHECKED: BII CADD FILE: II :PROJEC°rS DRAWING TITLE: THIRD FLOOR NEW PARTIAL FLOOR PLAN SHEET NO. TiL