07-323-007E
S
aKAaO f�11L
RECEPTI ON
0
i
i
M •
• •
• •
►' •I •
a M5 DETAILS
SCALE: 6" = 1' -0"
1/4" CAP TOP ,/t6"
CEILING P BOTTOM
_
0
Lil
0
a
_
F- L1J
0
Gjry
_LLI
rr' 0
L'j U
�z
L.1i >
Of ry ry
1
FLOOR
SURFACE MOUNTED
GUARD AT FULL
HEIGHT ELEVATION
GENERAL NOTES—- wa ry m_
A._ CONTRACTOR TO RECEIVE VEi4DO - DRAWk1C;'S= FROM
SWISSLOG INDICATING ROUTING PLAN. -
CONTACT INFO:
Damian L. Slaughter
Office: 001 - 727 - 895 -6356
Fax: 001 -303- 307 -3790 rt Ty
e -mail: damian.slaughter(a)_swissiog -Com"
B._ DIMENSIONS SHOWN ARE APPROXIMATE. THE
CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND
DIMENSIONS PRIOR TO BIDDING AND PRIOR TO START
ANY NEW WORK.
C.- ADJUST CEILING MOUNTED DEVICES, LIGHT FIXTURES,
HVAC SUPPLY AND RETURN, ETC. AS NECESSARY IN
FIELD.
D._ CONTRACTOR TO PATCH AND REPAIR AS NECESSARY,
ALL FINISHES MUST MATCH TO EXISTING.
NOTE THIS DRAWING
1 EXISTING WALLS TO REMAIN
2 NEW P -TUBE STATION. TO BE INSTALLED AS PER
MANUFACTURER SPECIFICATIONS. DRYWALL PARTITION ABOVE
AND BELOW STATION, CONTRACTOR TO PAINT TO MATCH
EXISTING, AND INSTALL RUBBER BASE TO MATCH EXISTING.
3 UNDERSIDE OF STRUCTURE.
4 FINISH CEILING. SEE FINISH SCHEDULE.
5 FINISH FLOOR. SEE FINISH SCHEDULE.
6 CONTINUOUS SEALANT EACH SIDE.
7 3%" 20 GA. METAL CHANNEL RUNNER.
8 5/8" GYPSUM BOARD.
9 CONTINUOUS FIRE STOP.
1 d 3 5/8" 20GA METAL STUDS @ 16" O.C.
11
3 1/2" SOUND ATTENUATION BLANKET STC 45 -49
<0> 1X" DEEP HORIZ BRACING CHANNEL AT MID -SPAN OF
WALL OR MAX 6' -0" SPACING,
CONTRACTOR TO PATCH AND REPAIR CEILING TILES AS
NECESSARY.
14 CORNER GUARD. ACROVYN SSM -20 FLOOR TO CEILING.
FINISH TO BE SELECTED BY ARCHITECT.
1 #6x1 5/8" BUGLE HD DRYWALL SCREW.
16 % GYPSUM BOARD
1 CONTINUOUS VINYL RETAINER.
18 HIGH IMPACT VINYL ACRYLIC EXTRUSION.
19 STEEL STUD
'q
'V zy uiiLs_
,.f4e`.,,�`8
NiF ri 10I
FLOOR
PLAN LEGEND
,.A
HATCH DEPICTS AREA OUT OF SCOPE OF WORK
F
NEW PREFAB WALL
-1
EXISTING WALLS
<8>
NOTE
-
WORK STATION NUMBER
DATA/VOICE WITH
GROMMET
RECEPTACLE
�❑1
WALL TYPE
BERMELLO AJAMIL &1 PARTNERS, INC.
Architecture Engineering Planning
Interior Design Landscape Architecture
2601 South Bayshore Drive 10th Floor
Miami, Florida 33133
(305) 859 -2050 Fax (305) 860 -3700
MEP ENGINEER:
MEPENGINEER INFORMATION
Smith, Seckman, Reid, Inc.
cil C) av 11 I-IT
=NGII`�T =.
600 West Hillsboro, Suite 300
Deerfield Beach, Florida 33441
Phone(954)421 -1260 Fax(954)421 -1466
�p N h►O
A* �
°
V
REVISIONS:
PROJECT NAME:
SOUTH MIAMI HOSPITAL P -TUBE STATION
NICU- 3RD FLOOR
PROJECT ADDRESS:
7400 S.W. 62nd Ave.
C.,.. 0, AA:., , T'1. 4A4 111 Al
SCALE:
DATE: 09 -I5-2006
DRAWN: AZ(FG
CHECKED: BII
CADD FILE: II :PROJEC°rS
DRAWING TITLE:
THIRD FLOOR
NEW PARTIAL
FLOOR PLAN
SHEET NO.
TiL