Loading...
14-492R-001-ACPWR PROVIDED FROM POUR PANEL F) i Iw PROJECT INFORMATION PROJECT INFORMATION: NAME OF PROJECT: PETCO OF S. MIAMI ADDRESS: 6200 S. DIXIE HWY S. MIAMI, FL 33143 PROPOSED USE: RETAIL P -25/26 TENANT (OWNER IN FEE) P -19120 P-40 PETCO ANIMAL SUPPLIES STORES, INC. MR REHCO ROAD CLAY EARLEY PROJECT MANAGER 407 - 895 -459 SAN DIEGO, CA 92121 TAMMY HALLORAN COODINATOR 858- 657 -203 FIRE ALARM VENDOR 7575'9'G 75H 75�_c 75O_G 75NI'0EOL - -_ -- REAR SALES EXIT VECTOR SECURITY LICENSE:EF20000395 Y 13555 WELLINGTON CENTER CIRCLE i SUPPLY RER PULL SUITE 123 U O 0.015 GAINESVILLE, VA 20155 0.040 0.040 FIRE ALARM DESIGNER D-7033 ANNUN 0.080 MICHAEL J. MAHONEY NICET IV # 94791 407 -475 -1110 VECTOR SECURITY EXT 1103 2500 MAITLAND CENTER PARKWAY RTU -2 2 MAITLAND, FL 32751 0.000550 0.001100 FIRE ALARM MONITORED BY: 0.001100 5 VECTOR SECURITY UL # S2535 888 - 832 -8671 3400 MCKNIGHT EAST DRIVE U 1 PITTSBURGH, PA 0000500 0.000500 FIRE ALARM INSTALLER: 0.000560 9 TBD 0.000550 0.004950 ' a ❑ 0 0 - NAG CIRCUIT /1 -.. CIRCUIT . /2 _ -. ❑ '� '•�W 0 ■Power ■Trouble Alarm ■Silenced O !♦Supervisory ■Gnd Flt 0 0 0 � FPD-7024 0 w 0 2�10ab. ❑ 7 ❑ $ 9 ❑ r.n ❑ Silence 0 0 © 0 _._ 0 0 0 '. _J 10 O� 0 C1CT00 ,. ax x a a r EXISTING PANEL 1=0 °rte Al FRUNI ENIRY NOTES 1. A MICROPROCESSOR -BASED MULTIPLEX FIRE ALARM SYSTEM WITH INTELLIGENT, ADDRESSABLE INITIATION DEVICES WALL BE REQUIRED. THE RISER DIAGRAM IS BASED AROUND A MULTIPLEX ADDRESSABLE SYSTEM. THE FIRE ALARM SYSTEM SHALL BE MONITORED BY AN LISTED CENTRAL STATION MONITORING SERVICE INTERFACE EQUIPMENT WILL BE FULLY UL LISTED AND FM APPROVED FOR THIS PURPOSE. 2. THE FIRE ALARM/DIGITAL ALARM COMMUNICATOR TRANSMITTER (FACP) SHALL BE POWER LIMITED. AND DERIVE ITS PRIMARY POWER (120VAC, 56 VA) FROM A 20 AMP CONTINUOUSLY ENERGIZED CIRCUIT IDENTIFIED FIRE ALARM CIRCUIT (LOCKOUT DEVICE SHALL BE PROVIDED ON BREAKER AND MARKED IN RED) AND THE SYSTEM SHALL BE EQUIPPED WITH A 24 HOUR STANDBY BATTERY. (SEE CALCULATIONS SHEET FA -3) J. THE SYSTEM SHALL COMMUNICATE WITH THE LISTED CENTRAL STATION VIA A DUAL LINE DIGITAL ALARM COMMUNICATOR TRANSMITTER (DACT). (REF NFPA 72 2007) A. THE DIGITAL ALARM COMMUNICATOR TRANSMITTER SHALL BE CONNECTED TO TWO (2) LOOP START TELEPHONE LINES. B. THE DACT WILL CONSTANTLY MONITOR EACH PHONE LINE AND WILL AUTOMATICALLY TRANSMIT A TROUBLE SIGNAL TO THE LISTED CENTRAL STATION, INDICATING WHICH, IF ANY, TELEPHONE LINE FAILED, VIA THE OTHER PHONE LINE AND SOUND A LOCAL TROUBLE" WARNING ON SITE - C. THE DACT USES THE PRIMARY PHONE LINE TO CALL THE PRIMARY PHONE NUMBER AT THE LISTED CENTRAL STATION. IF THE DACT IS UNABLE TO REACH THE PRIMARY NUMBER IN 10 TOTAL ALLOWED ATTEMPTS BETWEEN THE TWO DACT LINES, IT WILL AUTOMATICALLY DIAL THE SECONDARY PHONE NUMBER. D. THE DACT IS PROGRAMMED TO AUTOMATICALLY INITIATE AND COMPLETE A TEST SIGNAL TRANSMISSION TO THE LISTED CENTRAL STATION AT LEAST ONCE EVERY 24 HOURS. EACH ZONE SHALL THEN BE TRANSMITTED TO THE LISTED CENTRAL STATION. E THE AUTOMATIC TEST WALL ALTERNATE BETWEEN THE PRIMARY AND SECONDARY LINES (NFPA 2007) 4. THE SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO MANUFACTURER'S INSTRUCTIONS. 5 ALL POWER LIMITED WIRING SHALL BE INSTALLED PER NEC ARTICLE 760.5 6, THE SYSTEM SHALL UTILIZE U.L /NEC -760 APPROVED POWER LIMITLED FIRE CABLE AND /OR THHN /THWN 7. SIGNALING LINE CIRCUITS SHALL BE CLASS B, STYLE 4 MINIMUM. INITIATING DEVICE CIRCUITS SHALL BE CLASS B. STYLE B MINIMUM. NOTIFICATION APPLIANCE CIRCUITS SHALL BE CLASS B. STYLE Y MINIMUM. 8. ALL FIRE ALARM CABLING SHALL BE ROUTED THROUGH CONDUIT FROM DEVICES TO BOTTOM OF THE BAR JOIST. AT THAT POINT CABLING SHALL BE RUN EXPOSED ALONG THE CEILING IF ACCEPTABLE BY THE AHJ. 9. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LINE VOLTAGE (120 V. MAX.) IN SEPARATE CONDUIT. SHALL BE INSTALLED PER NEC UNLESS OTHERWISE NOTED BY LOCAL AUTHORITIES. 10. ALL EXPOSED CABLE BELOW THE BOTTOM OF THE BAR JOIST, OTHER ROOF STRUCTURE OR OTHER LOCATIONS WHERE THE CABLE MAY BECOME EXPOSED AND /OR DAMAGED, MUST BE INSTALLED WITHIN A STEEL CONDUIT. ALL SPLICES SHALL BE TERMINATED IN A BOX MARKED AS SPLICE POINT. 11. ALL CONDUIT, BOXES (UNLESS OTHERWISE INDICATED), FITTINGS, COUPLINGS, CONNECTORS, STRAPS, SUPPORTS, PULL-LINES, BUSHINGS, ETC. SHALL BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR, ALL WORK SHALL MEET OR EXCEED THE REQUIREMENTS OF NFPA 70. 12. ALL CONDUIT AND BACK BOX SIZES SHALL BE COORDINATED WITH THE FIRE ALARM CONTRACTOR. 13. ALL CONDUIT SHALL BE STUBBED UP TO BOTTOM OF BAR JOIST, 14: NO HORIZONTAL RUNS ON WALLS WILL BE ALLOWED BELOW THE BAR JOIST. 15. LOOSE WIRE SHALL BE INSTALLED AND SECURED TO THE UPPER LEVEL OF THE BAR JOIST AND SHALL RUN EITHER PARALLEL OR AT 90' TO THE JOIST. NO DIAGONAL WIRING WILL BE ALLOWED 16. THE INSTALLATION CONTRACTOR SHALL COORDINATE ALL LOCATIONS WITH THE LATEST FIXTURE PLANS PRIOR TO INSTALLATION. 17. FACP SHALL BE INSTALLED 60' ABOVE THE FINISHED FLOOR TO THE TOP OF THE BOX. 18. SMOKE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72 AND THE MANUFACTURER'S RECOMMENDATION FOR THE AREA OF INTENT. 19. MANUAL PULL STATIONS SHALL BE INSTALLED 48' ABOVE THE FINISHED FLOOR TO THE CENTER OF THE BOX. 20. REMOTE ANNUNCIATORS SHALL BE INSTALLED 54' ABOVE THE FINISHED FLOOR THE THE CENTER OF THE BOX 21. SUPERVISION: A. WIRING SHALL NOT BE LOOPED THROUGH DEVICES. WIRE MUST BE CUT FOR IN AND OUT CONNECTIONS, B. POINT, COMMON ANNUNCIATION AND T- TAPPING IS PROHIBITED. C. ALL WIRING TO THE INITIATING, NOTIFICATION DEVICES AND ANNUNCIATOR PANELS SHALL BE SUPERVISED. 22. SYSTEM OPERATION- A. ACTIVATION OF ANY FLOW SWATCH, SMOKE DETECTOR OR MANUAL PULL STATION. 1 -THE APPROPRIATE ZONE INDICATOR AT THE REMOTE( ANNUNCIATOR: a. WHAT TYPE OF DEVICE WAS ACTIVATED. b. FROM WHICH AREA THE ALARM WAS GENERATED. 2. ANCILLARY (HORN /STROBE) TO SOUND /FLASH. 3. THE APPROPRIATE ZONE ALARM SIGNALSHALL BE TRANSMITTED T O THE LISTED CENTRAL STATION FOR APPROPRIATE ACTION. B. ACTIVATION OF ANY OS &Y, PIV TAMPER SWITCH SHALL CAUSE: 1. THE APPROPRIATE ZONE INDICATOR AT THE REMOTE ANNUNCIATOR. a WHAT TYPE OF DEVICE WAS ACTIVATED. b- FROM WHICH AREA THE ALARM WAS GENERATED. 2. THE APPROPRIATE ZONE SUPERVISORY SIGNAL SHALL BE TRANSMITTED TO THE LISTED CENTRAL STATION FOR APPROPRIATE ACTION. 23. ALL NOTIFICATION APPLIANCES SHALL BE SYNCHRONIZED PER NFPA 72. 24. AUDIBLE EVACUATION SIGNAL SHALL BE TEMPORAL 3 PER NFPA 72. 25. STROBES ARE TO REMAIN FLASHING ON SYSTEM SILENCE. NFPA 72 2007 4.4.3.7.2 26. CIRCUIT BREAKER AND PANEL NUMBER AS WELL AS CENTRAL STATION ACCOUNT NUMBER ARE TO BE NOTED INSIDE OF FACP. 27. 24 HOUR EMERGENCY SERVICE TELEPHONE NUMBER FOR THE FIRE ALRM CONTRACTOR IS TO BE CONSPICUOUSLY POSTED ON THE FACP. ALARM CONTRACTOR MUST BE AVAILABLE FOR 24 HOUR SERVICE ON THIS SYSTEM. 28. FIRE ALARM INSTALLING CONTRACTOR TO COMPLETELY PRE -TEST SYSTEM PRIOR TO TEST WITH FIRE DEPARTMENT. 29- SYSTEM OPERATION, TESTING, TURN OVER WARRANTY, COMPLIANCE, AND AFTER MARKET SERVICE SHALL BE PROVIDED BY THE FIRE ALARM CONTRACTOR. 30. VECTOR SECURITY SHALL NOT BE RESPONSIBLE FOR UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THE MUST BE IN WRITING AND MUST BE APPROVED BY VECTOR SECURITY. 31. ALARM SIGNAL DEACTIVATION MEANS IS ACTUATED, BOTH AUDIBLE AND VISIBLE NOTIFICATION APPLIANCE SHALL BE SIMULTANEOUSLY DEACTIVATED - 32. THE SPRINKLER SYSTEM IS NOT SHARED WITH THE REST OF THE BUILDING. ]IS MONITORED BY H H GREGG FACPS EXISTING DEVCES NEW P -10 P -15 P -14 P -41 o P -47/48 P -29/30 P -31132 P -27128 P -17/18 P -21/22 P -11 M M P MR MR MR MR NR RECEIVING ❑ ❑ I � I � I I MAIN EXIT EXIT PULL 1 _❑� ❑ ( lJ 4J J I 4J I l�1 I PULL R RTU -10 RTU -7 RTU -8 RTU -6 RTU1 RTU -3 •Ic +�l �"' N 1H 41il �._ t vJ . • ua -.auu � I - r. rF r� � 1�1 !�I ^ P..! cx''' ;•^+' CTS V'�: ia- SYSTEM RISER N.T.S. FA -2 ° ❑ ° � R U rm PlAn _ El K am rim o 7F= ❑_p 1 1nmt o e EXISTING DEVICES ❑ ❑ _ ®. O M m Q ff S m NOTIFICATION APPLIANCE 2 CIRCUIT 4 - 0 'Cr']EO ° 115 ,0115 D75 e75 NOTIFICATION APPLIANCE 2 CIRCUIT 3 _ .�11. LAP.m 0 4r .O c . .� C 115 115 115 115 BOSCH RNAC -8A -4C NOTIFICATION APPLIANCE 1 CIRCUIT 2 Al C �O EOL2 P -12 P -13 P -25/26 P -23124 P -19120 P-40 P P MR MR MR P MAIN EXIT PULL FRONT RIGHT EXIT ❑ I T IFMW 7575'9'G 75H 75�_c 75O_G 75NI'0EOL - -_ -- REAR SALES EXIT __1 PULL Y SUPPLY i SUPPLY RER PULL 1 U O 0.015 W U 0.040 0.040 1 D-7033 ANNUN 0.080 0080 UAW 0.100 BOSCH D -7050 ry RTU -5 RTU4 RTU -2 2 NOTIFICATION APPLIANCE 1 CIRCUIT 1 Ec O O QED C EOL1 75 c 75 75 75 NEW NAC PANEL 0 CODE SUMMARY • SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION AND TESTING OF FIRE ALARM NOTIFICATION /INITIATE DEVICES IN A NEW ADDITION TO AN EXISTING PETCO RETAIL STORE_ THE SYSTEM SHALL BE MONITORED BY AN APPROVED LISTED CENTRAL STATION. • APPLICABLE BUILDING CODES BUILDING FIRE ELECTRICAL NFPA 72 MECHANICAL STATE OTHER 2010 FBC NOTIFICATION APPLIANCE 2 CIRCUIT 2 SF PP 2 -z -1 I 2 -z -2 �2 -2 -3 C OEOL 6 2009 FFC - - - -- 75 _ 75 75 ,. - -- 2008 NEC NOTIFICATION APPLIANCE 2 CULT 1 2007 EDITION I - - - -CIR 2 1 11 (2 1 2 1 2 1 3� 2 1 0 2 1 5 2 0 6 - -_ j - & 20' 2 911 5 97 c -- 7575'9'G 75H 75�_c 75O_G 75NI'0EOL - -_ -- 0 CODE SUMMARY • SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION AND TESTING OF FIRE ALARM NOTIFICATION /INITIATE DEVICES IN A NEW ADDITION TO AN EXISTING PETCO RETAIL STORE_ THE SYSTEM SHALL BE MONITORED BY AN APPROVED LISTED CENTRAL STATION. • APPLICABLE BUILDING CODES BUILDING FIRE ELECTRICAL NFPA 72 MECHANICAL STATE OTHER 2010 FBC w cs o SF PP V) ~ w n w 2009 FFC n in O 2008 NEC 2007 EDITION T__ SF PP 2010 FMC 20' 2 911 SF PP 97 8' • OCCUPANCY CLASSIFICATION MERCANTILE GROUP M • CONSTRUCTION TYPE it i i NOTE: THIS BUILDING IS DESIGNED TO BE FULLY SPRINKLED, I • GENERAL OCCUPANCY RETAIL STOCK GROOMING TOTAL INTERIOR TOTAL (SQ.FT.) 18,324 I^-. LL 6 SF PP J < o 611 n in O 20 1,086 T__ SF PP 4 20' 2 911 SF PP 97 8' STANDBY I • EAcH TOTAL Fire Alarm Control Panel ALARM « __1 tWtIN FAi 0.145 .� W 0275 O 1 U O 0.015 W U 0.040 0.040 1 D-7033 ANNUN 0.080 0080 UAW 0.100 BOSCH D -7050 ry 0.240 U ., ...0.415 2 67044 single input Rmdule 0.000550 0.001100 � 0.001100 5 H4.0U45 Addressable pull station 0.000550 0.002750 0.000550 U 1 67050 Snuke Detector/ Base 0000500 0.000500 22,3211 0.000560 9 712 0.000550 0.004950 0.000550 EXISTING PANEL BATTERY CALCULATIONS NEW BOSCN RNA( Project: _PETCO DateO61D9f14 t ` t7 y;, g;,. � it NEW NAC PANEL BATTERY CALCULATIONS 2 SYSTEM BATTERY CALCULATIONS N.T.S. FA-0 - EXISTWG ALTRONIX 1402ULADANAC PGWERSUPPLY Project:PETO .,.. .,,,u4.�, Date: 06/09214 511,111, Alln, Standby 2 16 SYS SEN PC2R (FLING 1`10 N STROBE 75cd ';0.094 4 36 „YS SEN SCR CEILING DEPOSE -,5,d -:4.158,; 0090; 10632 __... iu Unused - -._ =09^9. ,...LY'9 .0.040, .p.04p- -_._. 10 Unused 'D000 °x000. 0.000, -0.000: *0000, °;0.400 Standby AJ­ standby Alarm- Current Ciine.l _Cu-.t: Tolars : b.41X1 , _LL984 •1 19 SYS BEN PC2R CEILING HORN 51RDBE 115cd ;.q 490' 0229' • 0 000 "0.229? 1 39SYS3ENSCRCEILINGSTROBEll5cd x.0000, 0.210- !0010 Unused ;0000 ,0,000. 0010 Unused '',0000, ,0.004" 0.404. 0.000: 4.400 Totals. -4.000 0.439 Standby Am. Standby Alm. C.,,a.t Current Current 2 19 SYS SEN PC2R CEILING HORN STROBE 115ed '00^0 t0Op0' 2 39 SYS SEN SCR CEILING STROBE 115.0 .4,040 ' 0.210. 0.000 0.420.: 10 Unused :0090.. .4.004_ 0.000 - o,40o. 74 Uuused '; 9944 0.404. ' O,v44 4.wQ. 14.040 0.900, Circuit 4 Standby AVarm standby Alarm C.'­t CLivent Current current Totals. ., O.OW 4.975.' 2 19 SY5 SEN PC2R CEILING HORN STROBE 115cd 5:.0 q0p' -:0.224 0 000 X4.458„ 2 39 SYS SEN SCR CEILING STROBE 115cd '.0000, 0.214, 0.040, LO-4320, 2 36 SYS SEN SCR CEIUNC STROBE 75cd ,4 C4Q 0_154: ' 0.900 10 Unused "', 0 404. :4.01117: x0 -00 ' 90 Totals: '';:0904.- "1.194. EXISTING NAC PANEL BATTERY IAL U LATIO N -S P) It, . ^�n o FIFE .A.LARi4 SYST`EM'fO B'g [NSTAUE,D IN ACCORDANCE WITH NFPA 72; 70; 101 r4*LL BE A aN FRAL ST91 "044 P, ICE. A :-g'fl'rC;r E 0R PLACARD SHAU DE PO `f L-0 AT RNAL 1NSF"'rU'T1011I, AS PER NFPA 72 UUUU UUU U V UVUVU VJU U V U U tJ U V V W U V U U U U U U U V U U U V V U yvuVV U V U U U V U d V U U V UUU U U V U V V U W J V V H V U U V V U U U U V V U U V U V V VUU U V VUU UUU UUrt '� V U V U U U VVVU V V U U U V U U V UJ V u UVVVU U UVUUV V uuV u VVUV u l ,F INDEX OF DRAWINGS • FA -0 TITLE SHEET, GENERAL NOTES, CODE INFORMATION, FIRE ALARM RISER DIAGRAM & SYSTEM CALCULATIONS s FA -1 FIRE ALARM SYSTEM PLAN SYMBOL LEGEND �- - V =SE-:OUR DESCRIPTION MODEL NUMBER DESCRIPTION BOSCH 7024 LDRAWING PROJECT: PETCO 6200 S ONE HWY S. MIAMI FL = FIRE ALARM KEYPAD /ANNUNCIATOR Address: City 'tale �UANITry STANDBY I • EAcH TOTAL Fire Alarm Control Panel ALARM « __1 tWtIN FAi 0.145 0 -145` 0275 0275 1 67039 N1,11. DC Z -EX 0.015 0.015 0.040 0.040 1 D-7033 ANNUN 0.080 0080 UAW 0.100 BOSCH D -7050 _ -- 0.240 ., ...0.415 2 67044 single input Rmdule 0.000550 0.001100 0.000550 0.001100 5 H4.0U45 Addressable pull station 0.000550 0.002750 0.000550 0.002750 1 67050 Snuke Detector/ Base 0000500 0.000500 0.000560 0.000560 9 0-7053 nputiOutput nodule 0.000550 0.004950 0.000550 0004350 1 Circud #1 FRONT RIGHT SALES EXIT PULL STATION - 0.009300 0.150 0.150 1 Circud #2 X OTHERS 0.150 0.150 SPRINKLER TAMPER Total stand by current 0.q24 X Stand by hours Stand by anVhours _ 0 300 ' 16 Total Atarm Current X alaun Bnrmiea(5)i60 AlantiTatal arrWhours - 0.72, r ,'.4083 , - 006 RTU 1 DUCT DETECTOR X 18 Total Amp /hours X Derating factor of 20% Minimum Battery Size 1.2 EXISTING PANEL BATTERY CALCULATIONS NEW BOSCN RNA( Project: _PETCO DateO61D9f14 t ` t7 y;, g;,. � it NEW NAC PANEL BATTERY CALCULATIONS 2 SYSTEM BATTERY CALCULATIONS N.T.S. FA-0 - EXISTWG ALTRONIX 1402ULADANAC PGWERSUPPLY Project:PETO .,.. .,,,u4.�, Date: 06/09214 511,111, Alln, Standby 2 16 SYS SEN PC2R (FLING 1`10 N STROBE 75cd ';0.094 4 36 „YS SEN SCR CEILING DEPOSE -,5,d -:4.158,; 0090; 10632 __... iu Unused - -._ =09^9. ,...LY'9 .0.040, .p.04p- -_._. 10 Unused 'D000 °x000. 0.000, -0.000: *0000, °;0.400 Standby AJ­ standby Alarm- Current Ciine.l _Cu-.t: Tolars : b.41X1 , _LL984 •1 19 SYS BEN PC2R CEILING HORN 51RDBE 115cd ;.q 490' 0229' • 0 000 "0.229? 1 39SYS3ENSCRCEILINGSTROBEll5cd x.0000, 0.210- !0010 Unused ;0000 ,0,000. 0010 Unused '',0000, ,0.004" 0.404. 0.000: 4.400 Totals. -4.000 0.439 Standby Am. Standby Alm. C.,,a.t Current Current 2 19 SYS SEN PC2R CEILING HORN STROBE 115ed '00^0 t0Op0' 2 39 SYS SEN SCR CEILING STROBE 115.0 .4,040 ' 0.210. 0.000 0.420.: 10 Unused :0090.. .4.004_ 0.000 - o,40o. 74 Uuused '; 9944 0.404. ' O,v44 4.wQ. 14.040 0.900, Circuit 4 Standby AVarm standby Alarm C.'­t CLivent Current current Totals. ., O.OW 4.975.' 2 19 SY5 SEN PC2R CEILING HORN STROBE 115cd 5:.0 q0p' -:0.224 0 000 X4.458„ 2 39 SYS SEN SCR CEILING STROBE 115cd '.0000, 0.214, 0.040, LO-4320, 2 36 SYS SEN SCR CEIUNC STROBE 75cd ,4 C4Q 0_154: ' 0.900 10 Unused "', 0 404. :4.01117: x0 -00 ' 90 Totals: '';:0904.- "1.194. EXISTING NAC PANEL BATTERY IAL U LATIO N -S P) It, . ^�n o FIFE .A.LARi4 SYST`EM'fO B'g [NSTAUE,D IN ACCORDANCE WITH NFPA 72; 70; 101 r4*LL BE A aN FRAL ST91 "044 P, ICE. A :-g'fl'rC;r E 0R PLACARD SHAU DE PO `f L-0 AT RNAL 1NSF"'rU'T1011I, AS PER NFPA 72 UUUU UUU U V UVUVU VJU U V U U tJ U V V W U V U U U U U U U V U U U V V U yvuVV U V U U U V U d V U U V UUU U U V U V V U W J V V H V U U V V U U U U V V U U V U V V VUU U V VUU UUU UUrt '� V U V U U U VVVU V V U U U V U U V UJ V u UVVVU U UVUUV V uuV u VVUV u l ,F INDEX OF DRAWINGS • FA -0 TITLE SHEET, GENERAL NOTES, CODE INFORMATION, FIRE ALARM RISER DIAGRAM & SYSTEM CALCULATIONS s FA -1 FIRE ALARM SYSTEM PLAN SYMBOL LEGEND SYMBOL DESCRIPTION MODEL NUMBER DESCRIPTION FIRE ALARM CONTROL PANEL LDRAWING (MOUNT 0 60" AFF) BOSCH FPD -7024 = FIRE ALARM KEYPAD /ANNUNCIATOR BOSCH riiR -7033 Izl Q rl (MOUNT 0 54- AFF) SLC CIRCUIT (12V) 16/4 FPL FIRE CABLE ADDRESSABLE INPUT MODULE BOSCH D -7044 ANNUN CIRCUIT {24) ADDRESSABLE INPUT /OUTPUT MODULE BOSCH D -7053 O : NOTIFICATION APPLIANCE CIRCUIT PANEL ALTRONIX GTA�) NOTIFICATION APPLIANCE CIRCUIT PANEL ROACH RNAC -6A -aC I� ADDRESSABLE MANUAL ALARM MANUAL LJ PULL STATION (MOUNT ® 48- AFF) BOSCH FMM -7045 i✓ ADDRESSABLE SMOKE DETECTOR BOSCH D -7050 1✓ (CEILING MOUNTED) c HORN WITH STROBE (CEILING SYSTEM SENSOR MOUNTED) PCR2 O STROBE ONLY (CEILING MOUNTED) SYSTEM SENSOR SCR FACP SMOKE DETECTOR �( REMOTE TEST SWITCH INSTALLED BY SYSTEM SENSOR RTS151 K 11 FITS OTHERS 2 SMOKE DETECTOR IN DUCT INSTALLED BY OTHERS SYSTEM SENSOR D4120 S FLOW DETECTOR /SWITCH INSTALLED BY 13 FRONT RIGHT SALES EXIT PULL STATION - OTHERS TAMPER DETECTOR /SWITCH INSTALLED BY SPRINKLER FLOW X OTHERS -VAM END OF LINE RESISTOR SPRINKLER TAMPER WIRE LEGEND SYMBOL COLOR USAGE DESCRIPTION TROUBLE LDRAWING 12/2 FPL FIRE CABLE OB . = NAC CIRCUIT (24V) 14/2 FPL FIRE CABLE Izl Q rl :2 SLC CIRCUIT (12V) 16/4 FPL FIRE CABLE - -- ANNUN CIRCUIT {24) 18/6 FPLP FIRE C A BLE 4 O : DUCT DETECTOR PWR 14/2 FPL FIRE CABLE 5 1A 1Ell °I DI ElFIGIHIIIIIKILIMI NJ01?1 I- INDIVIDUAL HVAC SHUTDOWN 4 SYSTEM MATRIX N.T_S. FA -0 l �11 PT. # POINT TO BE ANNUNCIATED AS w FIRE ALARM SUPERRVISGirf ALARM TROUBLE 1 _ p •, ...- 13130000013000000008 2 _ Izl Q rl :2 Ln in 3 - -- 000000000 (V 4 O : masons (D Vl 5 6 13 EM1313INi1301 8 SON 6, 9 10 FACP SMOKE DETECTOR X 11 MAIN ENTRY PULL STATION X 12 MAIN ENTRY PULL STATION �.« sommu0nommuNssons� 13 FRONT RIGHT SALES EXIT PULL STATION - X 14 SPRINKLER FLOW X 15 SPRINKLER TAMPER X 16 17 RTU 1 DUCT DETECTOR X 1A 1Ell °I DI ElFIGIHIIIIIKILIMI NJ01?1 I- INDIVIDUAL HVAC SHUTDOWN 4 SYSTEM MATRIX N.T_S. FA -0 l �11 PT. # POINT TO BE ANNUNCIATED AS w FIRE ALARM SUPERRVISGirf ALARM TROUBLE 1 _ M �C LLJ n 2 _ Izl Q rl :2 Ln in 3 - -- CD C7 vt (V 4 O : (D Vl 5 6 7 8 9 10 FACP SMOKE DETECTOR X 11 MAIN ENTRY PULL STATION X 12 MAIN ENTRY PULL STATION X 13 FRONT RIGHT SALES EXIT PULL STATION - X 14 SPRINKLER FLOW X 15 SPRINKLER TAMPER X 16 17 RTU 1 DUCT DETECTOR X 18 RTU 1 RELAY X 19 RTU 2 DUCT DETECTOR X 20 RTU 2 RELAY X 21 RTU 3 DUCT DETECTOR X 22 RTU 3 RELAY X 23 RTU 4 DUCT DETECTOR X 24 RTU 4 RELAY X 25 RTU 5 DUCT DETECTOR X 26 RTU 5 RELAY X 27 RTU 6 DUCT DETECTOR X 28 RTU 6 RELAY X 29 RTU 7 DUCT DETECTOR X 30 RTU 7 RELAY X 31 RTU 8 DUCT DETECTOR X 32 RTU 8 RELAY X 33 34 - 35 RELAY END OF LINE SUPERVISION X 36 37 - - 38 - 39 - - -- 40 REAR SALES ID-MT PULL STATION X 41 RECEIVING EXIT PULL STATION X 42 - - 43 - 44 46 .' 47 R-TU 10 DUCT DETECTOR I II X 48 ,. RTU 10 RELAY ,11� X 49 V1 I a° 50 - a ALL FIRE ALARM WIRING MUST ANNUNCIATE A TROUBLE ABM DURING ` OPEN AND GROUND FAULT CONDITIONS. ADDITIONALLY ALL OUTPUT CIRCUITS (HORNS /STROBE) ARE REQUIRED TO ANNUNCIATE A TROUBLE ALARM DURING A WIRE TO WIRE SHORT CONDITION. THE FIRE ALARM SYSTEM WILL BE TESTED BY THE OWNER'S REPRESENTATIVES TO THE CRITERIA OF TABLES 6 -5 AND 6 -7 OF THE 2002 NFPA 72. 3 SYSTEM ANNUNCIATION N.T.S. FA -0 4 PREVISIONS DATE AHJ_CHANGES 6 -4 -14 v� ww F_ p w U ©m Z Q � 0- LLJ � ° U � `n U) - O !_- U) Q�QU {n0= =Z Q ZU) mow �- -LL1 CDQ0 m U n00Cn < 1- 3 = �6Z[ Cn © `r (n � T :D (n =)wI - L- UZ CD z ©�0 cn0 LLJU�U QI- O UOD < F° n 0r C) cif = =)0X0It LLJ �= 0 LL. L,rIU0LY- N 51 w i..t M �=l U U M �C LLJ n Ln C� Izl Q rl :2 Ln in r- r- CD to CD C7 vt (V Cn 1r-t s}" O : (D Vl 0 N 51 w � 10 LLJ n V) 5;� J E LL :2 JU(A O : (D Vl LL. SUBMITTALS BY: VECTOR SECURITY, INC. 25010 MAITLAND CTR PKWY SUITE 105 MAITLAND, FL 32751 407 -475 -1110 407 -475 -1115 fax DRAWN BY: JDM REVIEWED BY: MJM WEIR fvf 4791 i4�4eruaoo "qq O Vim.• } °� 0 e y _ OF 4 � . 65 E: 775 9 AT01" SHEET FA-0 -I 1 OF 2 SHEETS