Loading...
14-410-001SCALE: 1/4"=V-011 �� Nil o�C� TYPICAL HANGER DETAIL N T.5 - CONCRETE SLAB / 3/8" ROD COUPLING =1 3/8" POWDER DRIVEN STUD _ —3/8" ALL THREAD ROD HANGER RING &,-ADJUSTABLE PIPE(SIZE VARIES) (SIZES 1" TO 4 ") PIPE SIZE ROD SIZE TYPE F FASTENER MIN. 'C' DIM MAX. 'C' DIM 0 N= 3/8" 13/8" X 117/32" DROP -IN ANCHOR N 1-3 4" 1 74 13/6" 1- 7/8" 1 Y2.. 1516.. 2" 2" 2-3/8' 2 - 3/8" 2Y2" 1-3/16" 2-3/4" 3" 1 - 7/16" 3- Y4" 3 3/2" 14'4'. 3 - 5 /s" 4" 2" 3 -7/8' 6" 1/2" 1 3/4" x 3 3/4" DRP. -IN ANC. 3 %2" 8" MAXIMUM DISTANCE BETWEEN HANGER a 0 SIZE NOMINAL PIPE 3/4" 1" 11/4„ 11/2" 2" 2Y2" 3" 31/2" 4" 5" 6" 8" (INCHES) STEEL PIPE(EXCEPT) N/A 12' -0" 12' -0" 15' -0" 15'-0" 15' -0" 15' -0" 15' -O" 15' -0" 15' -0" 15' -0" 15' -0" THREAD LIGHTWALL STEEL PIPE N/A 12' -0" 12' -0" 12' -0" 12' -0" 12' -0" 12' -0" N/A N/A N/A N/A N/A THREAD LIGHTWALL CPVC PIPE 5'-6"j6'-0'j6'-0-j6'-6" T-0" 8' -0" 9' -0" 10' -0" N/A N/A N/A N/A MIM NOTE: COUPONS TO BE ATTACHED TO ALL NEW MECH TEES. 4 rM • ARMOVERS GREATER THAN uu 24' IN LENGTH SHALL BE SUPPORTED BY A HANGER. FIRE SPRINKLER SYSTEM LEGEND SCHEDULE 1. NEW MECH -TYPE TEE. 2. EXISTING BRANCHLINE. 3. ARMOVER.; 4. 1" DROP. 5. NEW SEMI - RECESSED PENDENT HEAD 6. EXISTING BRASS UPRIGHT HEAD 155 DEG STANDARD RESPONSE TO RELOCATE NEW CONNECTION DETAIL O N NEW TYCO FRB CHRCME PEND OR, 155 F. K =5.6, ORFICE =1/2" TY -3231 O ER EX. UP HEADS TO REMAIN AS IS (TY 3131,155 0 O EP EX. UP HEADS TO BE PLUGGED (TY 3131,155 0 —X-- EX. PIPE TO BE REMOVED EXISTING FIRE SPRINKLER SYSTEM PIPING NEW FIRE SPRINKLER SYSTEM PIPING TOTAL NUMBER OF HEADS =07 SCOPE OF WORK: - EXISTING FULLY PROTECTED TENANT SPACE -ADD OR REPLACE WITH PENDENT FIRE SPRINKLER HEADS AS SHOWN ON PLANS TO ACCOMODATE NEW CEILING LAYOUT. WHERE ADDITION OR MODIFICATION IS MADE TO AN EXISTING SYSTEM AFFECTING MORE THAN TWENTY ( 20 ) SPRINKLERS, THE NEW PORTION SHALL BE ISLOLATED AND TESTED AT NOT LESS THAN 200 PSI ( 13.8 bar ) FOR 2 HOURS. ( AS PER 24.2.1.5 NFPA -13 2007 EDITION ) FIRE SPRINKLER GENERAL NOTES • FIRE SPRINKLER SYSTEM IS DESIGNED BASED PER NFPA #13 2007 EDITION 1" THRU 2" PIPE TO BE XL PIPE 0 2 1/2" AND LARGER PIPE TO BE SCHEDULE 10 OR SUPER FLOW AS PER NFPA #13 • ALL MATERIALS TO BE UL LISTED AND COMPLY WITH NFPA #13 ALL PIPING TO BE HYDROSTATICALLY TESTED AT 200 PSI FOR 2 HOURS • MODIFICATIONS AFFECTING 20 OR FEWER SHALL NOT REQUIRE TESTING IN EXCESS OF SYSTEM WORKING PRESSURE (per NFPA 13 16.2.1.4.) MODIFICATIONS THAT CANNOT BE ISOLATED, SUCH AS RELOCATED DROPS, SHAT NOT REQUIRE TESTING IN EXCESS OF SYSTEM WORKING PRESSURE • ALL PIPING TO BE FLUSHED AS PER NFPA #13 • ALL FIRE SPRINKLER INSTALLATION PER NFPA #13 2007 EDITION • ALL HANGERS TO BE INSTALLED AS PER NFPA #13 2007 EDITION • NO PIPES LESS THAN 1" IN DIAMETER TO BE USED • PIPE BOLLARDS SHALL BE PROVIDED (BY OWNER) IN ORDER TO PROTECT THE FIRE SPRINKLER SYSTEM COMPONENTS FROM POSSIBLE DAMAGE. • FIRE SPRINKLER CONTRACTOR WILL NOT BE RESPONSIBLE FOR THE FOLLOWING: • a) painting of any pipe • b) electrical work of any kind NOTE: TOTAL NUMBER OF HEADS IN THIS SHEET =07 Gt`�O tr-PO SJ�'CV �0_ �t QP N.T.S. I— A NOTE: Use Hanger TYPICAL HANGER NO SCALE 1 -- Pipe (Length - A + 61 2 -- 31W Top Beam Clamp 2 -- 3/8' x 4' All Thread Rod 3 -- Ring I— A NOTE: Use Hanger rdh Angle Iron TYPICAL HANGER NO SCALE 1 -- M91e Iron with 1 Slots 3' From Both Ends (LENGTH = A + 61 2 -- 318 x 4' NI Thread Rod 2 -- 3/8: Top Beam Clamp 4 -- 3/8 Nuts 4 -- 3/8' Fender Washers . A i --]NOTE Use Hanger with krgle Iron TYPICAL HANGER NO SCALE 1 — An)fs Iron with 1 Slob 3' From Both Ends (LENGTH - A + 61 2 — 3/8' x 4' NI Thread Rod 2 — 3/8' Top Beam Clamp 4 — 3/8' Nub 4 — 3/8' Fender Washers FIRE PROTECTION PLAN scale -1/4" Z0 Z = M ^ W J M W M X ap 0CC .� w -J 0 Z W0 a u 0 N= fA i - U N � 0 a J b W �0 N 1u 'sar o a 0 W of O LL om Q w LU REVISIONS J -__j W a 0 � f Lb N Z Z = M ^ W J M W M X 0CC W w -J 0 _ wa � In W0 a u 0 N= LU c� N � 0 a J b W �0 N 1u 'sar o a Q Z J �e A Li w a O o! a Z w -J 0 _ wa � In 0 a 0 Ww o . Z z 0 a J Q) a z 30 W of I—iWr w N � w REVISIONS DESCRIPTION DATE: MARCH 13, 2014 DRAWN BY: D.R. 4 SCALE: 1/4 " =1' -0" j SEAL FP -01 ■ OF 1 <� ti