Loading...
14-17-0228 1 LLJ ci ul LL CL 0 Ix E ICE 8 • r a cc r 0 CL cr a a :r 2 N M iv t r' r BUILDING DEMAND LOADS LOAD DESCRIPTION REMODEL REMOVED LOAD (ASSUMED) VOLTAGE LIGHTING MFR CATALOG * _ VOLTAGE) NOTES RECEPTACLES. EMERGENCY LIGHT FIXTURE EXHAUST # 2X4, 2 LAMP, LAY -IN PRISMATIC WITH (1) 2 LAMP ELECTRONIC INSTANT START BALLAST. 120V/277V (GE) F28T8 /XLSPX41 ECO COOPER SUB-TOTAL: 1 ®Q t LIGHTING FIXTURE SCHEDULE ELECTRICAL SYMBOL 1 . NOTE: 1­115TUHIGAL PEAK DEMAND LOAD INCLUDES 125% OF DEMAND UTILITY PEAK TO EXISTING SERVICE ENTRANCE EQUIPMENT a JUNCTION BOX >G PANEL BOARD — 72" TO TOP OF ENCLOSURE (SEE SCHEDULES FOR MOUNTING TYPE) EXISTING CT CABINET/ METER ---ill GROUND AC GENERAL USE SNAP SWITCH, 20A, 120 -277 VAC - 42" AFF 3 THREE —WAY SWITCH, 20A. 120 -277 VAC — 42" AFF $T THERMAL SWITCH, SQUARE D #2510 —FG —IP EXIT LIGHT FIXTURE EXISTING EXISTING SYMBOL DESCRIPTION VOLTAGE LAMPS MFR CATALOG * _ VOLTAGE) NOTES IDENTIFIER DESCRIPTION_.-q EMERGENCY LIGHT FIXTURE m ELECTRICAL CONDUIT 1�n 2X4, 2 LAMP, LAY -IN PRISMATIC WITH (1) 2 LAMP ELECTRONIC INSTANT START BALLAST. 120V/277V (GE) F28T8 /XLSPX41 ECO COOPER 2GC8-- 232A125- UNV- U -U 1 ®Q - - - - - ELECTRICAL- CONDL47- RUN CONCEAkFrY VIA FLOORS, A. THERMOPLASTIC HOUSING, SINGLE — OR DOUBLE —FACE, UNIVERSAL MOUNT (CEILING, FLAT WALL, OR END MOUNT). WITH OR WITHOUT DIRECTIONAL ARROWS. 4bftM 6V 2 -HEAD EMERGENCY LIGHT 6V INCLUDED EXITRONIX LL50H 0 WALLS, U 2ERGROUR'D (PZAN "VIE1N) w � DUPLEX RECEPTACLE, 20A, 120V - 18" AFF X1 � CEILING OR BACK MOUNT LED EXIT WITH 2 HEAD EMERGENCY LIGHT 120V/277V RED LED EXITROMX VEX- U- BP- WB- WH -EL90 2 COUNTER, 20A, 120V — 6" ABOVE COUNTER LOAD DESCRIPTION DEMAND LOAD (KVA) D. MOUNT ON WALL 4" ABOVE DOOR FRAME, CONFIRM MOUNTING HEIGHT WITH LOCAL JURISDICTION. PROVIDE STEM WHERE REQUIRED, MOUNT SO TOP OF EXIT SIGH IS .BELOW BOTTOM OF LIGHT FIXTURES. COMBINATION MOTOR STARTER &GFCI GROUND FAULT CIRCUIT INTERRUPTING RECEPTACLE, 20A. 120V -- 18 AFF 1 . NOTE: 1­115TUHIGAL PEAK DEMAND LOAD INCLUDES 125% OF DEMAND UTILITY PEAK TO EXISTING SERVICE ENTRANCE EQUIPMENT a JUNCTION BOX >G PANEL BOARD — 72" TO TOP OF ENCLOSURE (SEE SCHEDULES FOR MOUNTING TYPE) EXISTING CT CABINET/ METER ---ill GROUND AC GENERAL USE SNAP SWITCH, 20A, 120 -277 VAC - 42" AFF 3 THREE —WAY SWITCH, 20A. 120 -277 VAC — 42" AFF $T THERMAL SWITCH, SQUARE D #2510 —FG —IP EXIT LIGHT FIXTURE EXISTING EXISTING MAIN DISTRIBUTION PANEL (MDP) NOTES: MAIN DISTRIBUTION PANEL (MDP) EXISTING CONDUIT AND CONDUCTORS TO REMAIN. EMERGENCY LIGHT FIXTURE 1. PROVIDE JUNCTION BOX HIGH OVERHEAD AND FLEXIBLE METAL CONDUIT CONNECTION. 2. EXIT SIGNS; A &IG ISOLATED GROUND RECEPTACLE, 20A. 120V - 18" AFF t 1 BUILDING DEMAND LOAD SUMMARY /L ®Q TAMPER SWITCH AND FLOW SWITCH A. THERMOPLASTIC HOUSING, SINGLE — OR DOUBLE —FACE, UNIVERSAL MOUNT (CEILING, FLAT WALL, OR END MOUNT). WITH OR WITHOUT DIRECTIONAL ARROWS. [:p30/NF NON -FUSED SAFETY SWITCH (AMP. RATING) B. SHADED QUADRANT(S) DENOTE POSITION OF FACES, ARROW SYMBOL ON PLANS DENOTES ORIENTATION OF DIRECTIONAL ARROWS. 0 DUPLEX RECEPTACLE MOUNTED HIGH OR ABOVE U-30/20 FUSED SAFETY SWITCH (SWITCH RATING /FUSE RATING) C. SPECIFIED UNIT IS AVAILABLE IN RED LETTERS ONLY. IF OTHER COLORS ARE REQUIRED BY LOCAL AUTHORITIES, E.C. TO PROVIDE ALTERNATE FIXTURE, COUNTER, 20A, 120V — 6" ABOVE COUNTER LOAD DESCRIPTION DEMAND LOAD (KVA) D. MOUNT ON WALL 4" ABOVE DOOR FRAME, CONFIRM MOUNTING HEIGHT WITH LOCAL JURISDICTION. PROVIDE STEM WHERE REQUIRED, MOUNT SO TOP OF EXIT SIGH IS .BELOW BOTTOM OF LIGHT FIXTURES. COMBINATION MOTOR STARTER � DOUBLE DUPLEX (QUAD) RECEPTACLE, 20A, LOAD FROM ABOVE. 3.4 KVA EXISTING 1 TC.) ETC.) 120V — 18" AFF LOAD FROM ABOVE (AMPS): 9.5 AMPS 'G1' Tc HISTORICAL PEAK DEMAND LOAD (AMPS): 445 AMPS WITHIN GROOMING AREA CIRCUIT BREAKER F�}► SPECIAL PURPOSE RECEPTACLE, RATING AS NOTED TOTAL DEMAND LOAD (AMPS): 455 AMPS �I TELEPHONE OUTLET - 18" AFF (U.O.N.) SERVICE SIZE (AMPS): 1000 AMPS CST CURRENT TRANSFORMER SPARE CAPACITY (AMPS)• 545 AMPS Q DATA OUTLET - 18" AFF (U.O.N.) 1 . NOTE: 1­115TUHIGAL PEAK DEMAND LOAD INCLUDES 125% OF DEMAND UTILITY PEAK TO EXISTING SERVICE ENTRANCE EQUIPMENT a JUNCTION BOX >G PANEL BOARD — 72" TO TOP OF ENCLOSURE (SEE SCHEDULES FOR MOUNTING TYPE) EXISTING CT CABINET/ METER ---ill GROUND AC GENERAL USE SNAP SWITCH, 20A, 120 -277 VAC - 42" AFF 3 THREE —WAY SWITCH, 20A. 120 -277 VAC — 42" AFF $T THERMAL SWITCH, SQUARE D #2510 —FG —IP EXIT LIGHT FIXTURE EXISTING EXISTING ``` `` �.� A r5765 �1r STATE OF l OR I ' SUBMISSION ' �' � � ■ 100% PERMIT SUBMISSION A � III Y F I�t MAIN DISTRIBUTION PANEL (MDP) MAIN DISTRIBUTION PANEL (MDP) EXISTING CONDUIT AND CONDUCTORS TO REMAIN. EMERGENCY LIGHT FIXTURE A B /L ®Q TAMPER SWITCH AND FLOW SWITCH [:p30/NF NON -FUSED SAFETY SWITCH (AMP. RATING) U-30/20 FUSED SAFETY SWITCH (SWITCH RATING /FUSE RATING) COMBINATION MOTOR STARTER UH MECHANICAL EQUIPMENT (MOTOR, HVAC, PLUMBING, EXISTING 1 TC.) ETC.) 'G1' Tc TIME CLOCK INAREA WITHIN GROOMING AREA CIRCUIT BREAKER RECEIVING AREA RECEIVING FUSED SWITCH CST CURRENT TRANSFORMER El PUSH BUTTON BUZZER PARTIAL SINGLE LINE DIAGRAM PARTIAL SINGLE 08 S S SOUND SYSTEM SPEAKER (BY PETCO'S VENDOR) REF.; NO SCALE SECURITY SYSTEM ELECTRICAL GENERAL NOTES ® ® CEILING MOUNTED OCCUPANCY SENSOR CONDUIT 6" STUB —OUT 1. ELECTRICAL WIRING: NEEDED), * EXPOSED: RGS CONDUIT. SLIM CEILING MOUNTED LIGHT SENSOR EXIT FIRE ALARM A. IN GENERAL, BRANCH CIRCUIT WIRING IS NOT SHOWN ON THE PLAN B. ALL EXPOSED CONDUITS SHALL BE RUN PARALLEL TO OR • UNDERGROUND: CONCRETE ENCASED SCHEDULE 40 PVC CONDUIT. ® WATTS TRANSDUCER AUDIO /VISUAL DRAWINGS. NUMERALS ADJACENT TO ITEM SYMBOLS FOR LIGHTING PERPENDICULAR TO BUILDING STRUCTURE. • FINAL CONNECTIONS: LIQUID —TIGHT FLEXIBLE CONDUIT, MAXIMUM 18" FIXTURES, RECEPTACLES, MOTORS, APPLIANCES, ETC. INDICATE THE IN LENGTH. — DEVICE CIRCUIT NUMBER TO WHICH THE ITEM IS TO BE CONNECTED. PROVIDE 5, WIRING METHODS: BRANCH CIRCUIT WIRING FOR ALL ITEMS SHOWN IN ACCORDANCE WITH A. GENERAL: E. INDOORS CLASSIFIED 'DAMP' OR 'WET' LOCATIONS: THESE GENERAL NOTES AND THE ELECTRICAL SPECIFICATIONS. 0 IN FINISHED AREAS, CONCEAL ALL WIRING IN BUILDING WALLS, ALL FEEDERS AND BRANCH CIRCUITS SHALL CONSIST OF PULLED NOTE: SEE SHEET EMS1.1 FOR ENERGY MANAGMENT SYSTEM (EMS) B. LIGHTING BRANCH CIRCUIT WIRING, WHERE SHOWN, IS INTENDED TO FLOORS, AND ABOVE CEILINGS, CONDUITS MAY BE RUN EXPOSED ONLY CONDUCTORS IN RGS CONDUIT, CONNECTIONS TO VIBRATING EQUIPMENT SYMBOLS LEGEND TELEPHONE SHOW SWITCHING ARRANGEMENT OF FIXTURES. WHERE SHOWN SPECIFICALLY ON THE DRAWINGS OR WHERE EXISTING SHALL BE LIQUID TIGHT FLEXIBLE CONDUIT, MAXIMUM 18" IN LENGTH. HANDSET C. LOWER CASE LETTER ADJACENT TO SWITCH SYMBOL AND INSIDE OF CONDITIONS PRECLUDE CONCEALING. LIGHT FIXTURE SYMBOL INDICATES SWITCHING ARRANGEMENT OF * NO WIRING SHALL BE INSTALLED EXPOSED ON THE OUTSIDE SURFACES F. CAST OUTLET BOXES SHALL BE USED IN AREAS WHERE CONDUIT IS SOUND SYSTEM FIXTURES. OF THE BUILDING(S). RUN EXPOSED. PVC COATED CAST OUTLET BOXES SHALL BE USED WITH VOLUME CONTROL p, ALL 1 POLE. 15 AND 20 AMPERE BRANCH CIRCUITS SERVING RECEPTACLES OR LIGHTING SHALL BE 2 WIRE CIRCUITS PROVIDING AN FINAL CONNECTIONS TO MECHANICAL EQUIPMENT, FIXTURES, MOTORS, TRANSFORMERS, INSTRUMENTS, AND CONTROL DEVICES SHALL BE FLEXIBLE PVC COATED CONDUIT. INDIVIDUAL NEUTRAL CONDUCTOR FOR EACH UNGROUND (HOT) CIRCUIT CONDUIT. G. ALL LOW VOLTAGE WIRING SHALL BE RATED FOR ITS SPECIFIC USE, CONDUCTOR. DO NOT SHARE NEUTRAL CONDUCTORS. BRANCH B. BELOW GRADE (UNDERGROUND IN EARTH OR FILL): WIRING IN ANY AREA WHICH MAY BE CONSIDERED A PLENUM BY THE 88" 80" 7SWITCHBANK CIRCUIT WIRING SHALL BE 2 #12, #12G IN 3/4" CONDUIT UNLESS NOTED . SERVICE TRANSFORMER SECONDARY LATERAL AND ALL FEEDERS LOCAL AHJ, SHALL BE PLENUM RATED. ALL EXPOSED WIRING WITH THE OTHERWISE. SHALL CONSIST OF PULLED CONDUCTORS IN CONCRETE ENCASED EXCEPTION OF FIRE ALARM SYSTEM WIRING SHALL BE WHITE. SCHEDULE 40 PVC. CONDUITS. PROVIDE MAGNETIC MARKER TAPE 6" 2, EQUIPMENT GROUNDING; BELOW GRADE. CONCRETE ENCASEMENT SHALL BE 3" MINIMUM ALL 6, ELECTRICAL EQUIPMENT ENCLOSURES SHALL BE PROVIDED AS LISTED HATCH MARKS, IF SHOWN, DO NOT INDICATE GROUND WIRES. GROUND AROUND AND BETWEEN CONDUITS. BELOW UNLESS NOTED OTHERWISE: 42• WIRES SHALL BE PROVIDED AS FOLLOWS: . BRANCH CIRCUITS SHALL CONSIST OF PULLED CONDUCTORS IN DIRECT * INDOORS UNCLASSIFIED AREAS: NEMA 1 A. EQUIPMENT GROUND WIRES SHALL BE PROVIDED IN ALL FEEDERS AND BURIED SCHEDULE 40 PVC CONDUITS. • INDOORS CLASSIFIED 'DAMP': NEMA 1 r'° ALL BRANCH CIRCUITS. . MINIMUM BURIAL DEPTH SHALL BE 24 ". + INDOORS CLASSIFIED 'WET': NEMA 4 I --PANEL FraOa PREP RECEPTACLE, B. ALL FLEXIBLE METAL OR LIQUIDTIGHT CONDUIT CONNECTIONS TO ALL ELBOWS USED WITH PVC CONDUIT SHALL BE RGS. • OUTDOORS: NEMA 3R t DATA JACK OR EQUIPMENT MOTORS, TRANSFORMERS. LIGHTING FIXTURES, ETC. SHALL , REFER TO SITE PLANS FOR ADDITIONAL SITE UNDERGROUNDS WIRING RELIEF KITTEN TELEPHONE JACK CONTAIN EQUIPMENT GROUND WIRES. FLEXIBLE METAL CONDUIT SHALL REQUIREMENTS. 7. TERMINATIONS (LUGS TERMINALS ETC.) ON ALL EQUIPMENT SHALL BE AREA 107 18" NOT BE USED AS AN EQUIPMENT GROUND CONDUCTOR. 'MC' C. INDOORS (UNCLASSIFIED): RATED FOR USE WITH 75C CONDUCTORS. 1 I' CLEANING E t°e C. WHERE TYPE METAL CLAD CABLE IS SPECIFIED, THE CABLE SHALL ` EXPOSED SUBJECT TO DAMAGE: RGS CONDUIT. CLOSET RECEP FLOOR (GREEN) COPPER EQUIPMENT WITH AN INSULATED GREEN BE EQUIPPED WI IN DRY WALLS /ABOVE CEILINGS AND EXPOSED NOT SUBJECT TO 8. CONTINUITY OF EXISTING SYSTEMS AND CIRCUITS TO REMAIN SHALL 'Oa z GROUND WIRE EQUAL IN SIZE TO THE INSULATED CIRCUIT CONDUCTORS. AMA EMT CONDUIT. WHERE PERMITTED CODE, TYPE METAL REMAIN INTACT DURING AND AFTER CONSTRUCTION. ANY INTERRUPTION OF DOG PLAY CORRIU NOTES: D. ISOLATED GROUND WIRE INSULATION SHALL BE COLORED GREEN WITH A O CLAD CABLE MAY BE USED FOR LIGHTING BRANCH CIRCUITS ABOVE C SERVICE OF ANY KIND SHALL BE COORDINATED WITH THE OWNER AREA '' CAT VISIT RI°.� 1. THIS DETAIL IS A TYPICAL COMPOSITE VIEW OF SOME DEVICES LOCATED YELLOW STRIPE TO DIFFERENTIATE IT FROM EQUIPMENT OR SYSTEM SUSPENDED CEILINGS AND IN STUD PARTITIONS FOR WHIPS TO INDIVIDUAL ARCHITECT, AND OTHER TRADES. m ire Ios SMALL AtrlL IN THE COMMON AREAS. SEE PLAN FOR ACTUAL LOCATIONS. GROUND WIRES. DEVICES. MAXIMUM 6' LENGTH. MC CABLE MUST BE INSTALLED NEATLY ` 106 AND ORDERLY, PARALLEL WITH OR PERPENDICULAR TO BUILDING 9• CONTRACTOR SHALL COORDINATE ACTIVITIES WITH LOCAL UTILITIES VISITATION R 2. INSTALL DEVICES ON COMMON VERTICAL CENTERLINE WHERE 3. DISCONNECT SWITCHES SHALL BE HEAVY DUTY TYPE WITH LOCKABLE HANDLE. ONE MANUFACTURER SHALL BE USED THROUGHOUT THE STRUCTURE, TO THE SATISFACTION OF THE PETCO PROJECT MANAGER OR (POWER, TELEPHONE) AND SHALL INCLUDE ALL UTILITY REQUIREMENTS _ �� APPLICABLE PROJECT. ACCEPTABLE MANUFACTURERS ARE SQUARE D. GENERAL CABLE MAY BE SUBJECT TO REMOVAL AND REPLACEMENT AT NO INCLUDING BUT NOT LIMITED TO MATERIALS LABOR AND METERING CONTRACTOR SHALL SECURE, PAY, AND SCHEDULE ALL PANEL 'MDP' ELECTRIC, SIEMENS AND CUTLER HAMMER. ADDITIONAL COST TO PETCO. CIRCUITS MUST BE LABELED .EVERY 10'. . REQUIRED PERMITS, FEES, AND INSPECTIONS. 3. INSTALL DEVICES AT INDICATED HEIGHTS UNLESS OTHERWISE NOTED. • IN CONCRETE WALLS /FLOORS: RGS CONDUIT, .REQUIRED ALL DEVICE LOCATION SHALL MEET OR EXCEED ADA REQUIREMENTS. 4. CONDUIT ROUTING: FINAL CONNECTIONS: FLEXIBLE METAL CONDUIT (LIQUID -TIGHT 10. REFER TO ARCHITECTURAL PLANS AND PROJECT MANUAL FOR TYPICAL DEVICE MOUNTING HEIGHTS 05 A. ALL CONDUITS SHALL BE RUN ABOVE THE SLAB, NO UNDER SLAB FLEXIBLE CONDUIT IN DAMP OR WET AREAS). TRENCHING DETAIL AND SLAB REPAIR. KEY PLAN 01 CONDUITS ARE PERMITTED (TO ALLOW FOR FUTURE FLEXIBILITY OF POWER REF.: NO SCALE RELOCATION AND AVOIDANCE OF CONFLICT WITH FUTURE PLUMBING, IF D. OUTDOORS: REF.: NO SCALE ``` `` �.� A r5765 �1r STATE OF l OR I ' SUBMISSION ' �' � � ■ 100% PERMIT SUBMISSION A � III Y F I�t