INTRODUCTION
C. ACCESSIBILITY
i
KEYNOTE SYMBOL
1)
APPLICATION — THESE DOCUMENTS REFLECT THE DESIGN PROFESSIONALS; INTERPRETATION OF
A.
PURPOSE
ITEM
THE APPLICABLE ADA REQUIREMENTS AND OTHER KNOWN FEDERAL, STATE AND LOCAL LAWS,
1)
THIS SHEET PROVIDES SOME BACKGROUND INFORMATION ON WHAT INFLUENCED THE DESIGN
DETAIL IDENTIFIER
RULES, CODES, ORDINANCES AND REGULATIONS AS THEY APPLY TO THIS PROJECT.
SHOWN ON THESE DOCUMENTS.
2)
EXISTING CONDITIONS — ALL NEW WORK SHALL BE IN ACCORDANCE WITH THE AMERICANS WITH
DRAWING # P2.1 (DWG DETAIL IS LOCATED
2)
ALTHOUGH SOME INFORMATION CONTAINED HEREIN APPLIES TO A SPECIFIC TRADE, IT MAY
DISABILITIES ACT OR THE APPLICABLE BARRIER FREE CODE, WHICHEVER IS MORE STRINGENT.
4 P2
SECTION IDENTIFIER
PROVIDE SOME INSIGHT TO OTHER TRADES.
D. ANIMAL WELFARE
B.
DISTRIBUTION
1)
ENVIRONMENT — SOME AREAS OF THE BUILDING HAVE SPECIFIC PROVISIONS FOR TEMPERATURE
DRAWING # P2.1 (DWG DETAIL IS LOCATED
1)
THE PME SHEET SHOULD BE DUPLICATED AND ISSUED TO THE PLUMBING, HVAC AND
AND /OR LIGHTING CONTROL.
01
P2.1
ELEVATION IDENTIFIER
ELECTRICAL SUBCONTRACTORS ALONG WITH THEIR RESPECTIVE SPECIFIC TRADE DRAWINGS.
2)
SCHEDULE — THERE ARE NO OVERNIGHT STAYS FOR ANIMALS OTHER THAN THOSE FOR
ELEVATION # 01
2)
SOME PETCO VENDORS MAY ALSO BENEFIT FROM THIS INFORMATION.
DRAWING # P2.1 (DWG DETAIL IS LOCATED
PURCHASE, SUCH AS FISH, SMALL ANIMALS (SUCH AS HAMSTERS & GERBILS) AND REPTILES.
AFF
SPECIAL EMPHASIS, CONCERNS, AND LIMITATIONS
DOCUMENTS
AFG
A.
CONSTRUCTION
A. DRAWING ORGANIZATION AND PRESENTATION:
BELOW FINISHED GRADE
1)
CIRCUITING — THE BUILDING CIRCUITING AND WIRING INCLUDES SOME SUBTLE YET IMPORTANT
1)
DRAWING LIST - REFER TO ARCHITECTURAL DRAWINGS FOR DRAWING LIST.
CEILING
CONTR
FEATURES. DO NOT DEVIATE FROM THE WIRING SHOWN WITHOUT SPECIFIC PERMISSION FROM
2)
HOW NOTES ARE USED
DOWN
DWG(S)
THE PETCO PROJECT MANAGER.
A) GENERAL NOTES — ONE OR MORE IN LIST FORM WHICH ARE NOT INDICATED SPECIFICALLY
ELECTRIC CONTRACTOR
2)
MOUNTING — NO EQUIPMENT SHALL BE MOUNTED DIRECTLY TO THE UNDERSIDE OF THE ROOF.
ON A PLAN, SECTION, ELEVATION OR DETAIL.
EQUIPMENT
3)
EQUIPMENT — LONG LEAD ITEMS MUST BE ORDERED PROMPTLY TO ENSURE TIMELY DELIVERIES.
B) NOTES FOR THIS DRAWING — GENERAL NOTES LOCATED ONLY ON THE DRAWING THAT
ELECTRIC WATER COOLER
B.
COMMUNICATION
EXISTING
APPLIES. '
FLA
FULL LOAD AMPS
1)
NOTIFICATION - THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY UPON DISCOVERY OF A
FLOW SWITCH
C) KEY NOTES — USED IN LIEU OF STANDARD NOTES WHERE THEY IMPROVE READABILITY,
GC
GENERAL CONTRACTOR
PROBLEM OR CONFLICT THE CONTRACTOR SHALL PROMPTLY IDENTIFY ONE OR MORE
GYPSUM WALL BOARD
KEY NOTES ARE GATHERED TOGETHER AND LISTED COLLECTIVELY ON THE DRAWINGS ON
HP
HORSEPOWER
PROPOSED SOLUTIONS BUT SHALL NOT PROCEED UNTIL SO AUTHORIZED.
MECHANICAL CONTRACTOR
WHICH THEY ARE LOCATED.
MCA
MINIMUM CIRCUIT AMPS
2)
COORDINATION — COORDINATE THE LOCATIONS AND ORIENTATIONS OF ALL EQUIPMENT WITH
3)
MISCELLANEOUS
MH
MOUNTING HEIGHT
OTHER TRADES.
MOTOR OPERATED DAMPER
A) TERMS — THE TERMS 'SHEET', 'DRAWING' AND 'PLAN' ARE USED INTERCHANGEABLY. THE
NIC
C.
LIMITATIONS
1
PENETRATIONS —ROOF AND WALL PENETRATIONS SHALL BE LIMITED TO AREAS IDENTIFIED ON
NOT TO SCALE
TERM "PROVIDE' MEANS "FURNISH AND INSTALL ',
OG
ON CENTER
PC
PLUMBING CONTRACTOR
B} SCALE — PRINTING OF THE PLANS IS OFTEN REDUCED, SO A GRAPHIC SCALE IS PROVIDED
PSI
POUNDS PER SQUARE INCH
THE DRAWINGS. NO DEVIATIONS SHALL BE MADE WITHOUT WRITTEN CONSENT OF THE
POLYVINYL CHLORIDE
ON EACH SHEET. DO NOT SCALE ANY DRAWINGS.
RPM
REVOLUTIONS PER MINUTE
2)
ARCHITECT:
LOCATIONS — EQUIPMENT SHALL BE LOCATED WITHIN A REASONABLE DISTANCE OF THE
DUCT SMOKE DETECTOR
C) ADDENDA & REVISIONS — SOME ADDENDA AND REVISIONS ARE IDENTIFIED ON THE
SO. FT.
SQUARE FEET
LOCATIONS SHOWN.
TYPICAL
DRAWINGS USING A NUMBER IN A TRIANGLE. THE NUMBER IN THE TRIANGLE LINKS TO
3)
INTERRUPTIONS — IF APPLICABLE, COORDINATE ALL DISCONNECTIONS AND INTERRUPTIONS OF
THE REVISION BLOCK IN THE TITLE BLOCK SECTION. SOMETIMES THE MOST RECENT
PLUMBING, HVAC, FIRE SUPPRESSION, ELECTRIC AND FIRE ALARM SYSTEMS WITH THE BUILDING
CHANGE IS CLOUDED TO PROVIDE INCREASED CLARITY.
B. SPECIFICATIONS
OWNER. A SCHEDULE OF INTERRUPTIONS AND SHUTDOWNS SHALL BE SUBMITTED TO THE
1)
TECHNICAL SPECIFICATIONS AND RESPONSIBILITIES ARE INCLUDED IN THE PROJECT MANUAL.
OWNER AND APPROVAL RECEIVED TWO WEEKS PRIOR TO ANY ANTICIPATED INTERRUPTION.
PROVIDE BUILDING —WIDE FIRE WATCH DURING ANY FIRE ALARM SERVICE INTERRUPTION.
G. COORDINATION
REACTIVATE FIRE ALARM SYSTEM AT THE END OF EACH .WORKING DAY.
1)
STORE FIXTURES, FURNISHINGS, AND EQUIPMENT SHALL BE INSTALLED AND LOCATED IN
D.
CONTRACTORS' RESPONSIBILITIES
1)
PERMITS - EACH SUBCONTRACTOR SHALL SECURE AND PAY FOR ALL REQUIRED PERMITS AND
ACCORDANCE ITH A TOR FIXTURE LAYOUT PLAN PROVIDED AT THE M F DELIVERIES T
E STORE TS E L U L 0 DED E E 0 DEL VE ES 0
SHALL ARRANGE ALL REQUIRED INSPECTIONS FOR WORK UNDER HIS TRADE.
THE JOB SITE OF STORE FIXTURES AND FURNISHINGS. FINAL LOCATIONS MAY .VARY FROM AS
S
2)
EXISTING CONDITIONS - EACH SUBCONTRACTOR SHALL FAMILIARIZE HIMSELF WITH EXISTING
SHOWN ON THE FLOOR PLANS IN THIS SET OF DRAWINGS.
CONDITIONS TO ADEQUATELY AND ACCURATELY BID. BUY AND CONSTRUCT THIS PROJECT.
GENERAL
NOTES
SOME EXISTING CONDITIONS ARE HIDDEN CONDITIONS. WHEN ENCOUNTERING SUCH CONDITIONS
DURING CONSTRUCTION WHICH REQUIRE DEVIATION FROM THE DOCUMENTS, THE CONTRACTOR
A. ALL
TRADES
SHALL SUBMIT A REQUEST FOR INFORMATION (RFI) FORM, WHICH CAN BE FOUND IN THE
1)
RESPONSIBILITIES & COORDINATION
PROJECT MANUAL. THIS FORM SHALL BE ACCOMPANIED BY ONE OR MORE PROPOSED
A) REFER TO PROJECT MANUAL FOR RESPONSIBILITIES REGARDING LOCAL PERMITTING AND
SOLUTIONS. THE INTENT IS TO DEFINE A SCOPE OF WORK FOR THE SUCCESSFUL CONTRACTOR
UTILITY COMPANY REQUIREMENTS, FEES AND INSPECTIONS.
TO EVALUATE AND REPORT ON THE EXISTING CONDITIONS SO THAT ANY ADJUSTMENTS TO THE
B) SEE ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION &
PROPOSED SYSTEM CAN BE REVIEWED, APPROVED AND RESOLVED PREFERABLY PRIOR TO
DETAILS REGARDING ROOF CURBS AND PENETRATIONS, INCLUDING INSULATING, FLASHING,
COMMENCEMENT OF WORK AND CERTAINLY BEFORE THE COMPLETION OF THE CONTRACT.
COUNTERFLASHING & SEALING, AND COORDINATE WITH THE ROOFING SUBCONTRACTOR.
3)
COORDINATION — EACH CONTRACTOR /SUBCONTRACTOR SHALL COORDINATE HIS WORK WITH ALL
G} ALL EQUIPMENT SHALL BE FURNISHED WITH SHOP DRAWINGS, GUIDELINES,
OTHER CONTRACTORS AND FIELD CONDITIONS. COORDINATE ALL ROOF PENETRATIONS WITH
.INSTALLATION
MAINTENANCE MANUALS, .SCHEDULES, TAGS, AND LETTER OF GUARANTEE IN A BINDER
ROOFING SUBCONTRACTOR, MAINTAINING .ROOF WARRANTY IF APPLICABLE.
(THREE -RING) WITH TABS. ALL EQUIPMENT SHALL BE INSTALLED IN CONFORMANCE WITH
4)
OWNER — SUPPLIED ITEMS (OSI) - ALL CONTRACTORS /SUBCONTRACTORS SHALL VERIFY
REQUIREMENTS BEFORE PROCEEDING WITH THE WORK.
THESE DOCUMENTS AND THE EQUIPMENT MANUFACTURER'S RECOMMENDATIONS.
5)
SIGNS — FINAL SIGN LOCATIONS AND CONNECTIONS SHALL BE COORDINATED WITH THE SIGN
D) EACH CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING OF ANY
CONTRACTOR.
WALLS, ROOF, OR FLOOR DURING CONSTRUCTION REQUIRED BY HIS TRADE. OPENINGS
6)
FIXTURE PLAN — VERIFY LATEST FIXTURE PLAN PRIOR TO INSTALLATION OF LIGHTING, DEVICES,
WHERE PIPING, DUCTS, CONDUITS, ETC. PASS THROUGH WALLS, FLOORS, OR CEILINGS
ETC., WHICH DEPEND ON EXACT LOCATIONS OF STORE FIXTURES.
SHALL BE CLOSED OFF AND SEALED.
7)
SUBSTANTIAL COMPLETION — MAKE FINAL CONNECTIONS AND PERFORM STARTUP OF EQUIPMENT
E) ALL FIELD CONDITIONS AND DIMENSIONS SHOWN ON THE DRAWINGS SHALL BE VERIFIED
FOR COMPLETE-AND OPERATIONAL BUILDING UPON COMPLETION. REFER TO ARCHITECTURAL
PRIOR TO SUBMITTING BIDS & PRIOR TO COMMENCEMENT OF WORK (INCLUDING UNIT
PLANS FOR RESPONSIBILITIES MATRIX.
ORIENTATION). NO ALLOWANCE WILL BE MADE FOR NOT COMPLYING WITH THIS
E.
STANDARDIZATION
REQUIREMENT.
1)
PROTOTYPE — THIS PROJECT IS NOT ONE OF A KIND. IT IS APPLYING SOME CHARACTERISTICS
F) MAKE FINAL CONNECTIONS TO OWNER'S EQUIPMENT.
OF A PROTOTYPE DESIGN TO THE SITE IN ORDER TO MAINTAIN STANDARDIZATION. ALSO, SOME
G) VERIFY THE EXACT LOCATION OF DIFFUSERS, LIGHTS, DEVICES, ETC., PRIOR TO
DESIGN DECISIONS WERE BASED ON THE OWNER'S PAST EXPERIENCE. THEREFORE IN SOME
INSTALLATION. PETCO RESERVES THE RIGHT TO MAKE MINOR ADJUSTMENTS TO THE
WAYS THIS PROJECT REQUIRES STRICTER ADHERENCE TO THE DOCUMENTS THAN NORMAL
LOCATIONS AS SHOWN ON THE DRAWINGS PRIOR TO INSTALLATION WITHOUT ADDITIONAL
PROJECTS.
COMPENSATION TO THE CONTRACTOR.
2)
PRODUCT STANDARDIZATION INCLUDES:
2)
CONSTRUCTION
A) SECURITY SYSTEM
A) PROPER FIRE PROTECTION MEASURES, SATISFACTORY TO THE LOCAL FIRE DEPARTMENT
B) POINT —OF —SALE (POS) SYSTEM
SHALL BE TAKEN WHEN WELDING OR CUTTING WITH TORCHES OR ELECTRIC ARC.
C) WORK ROOM SINK
B) REMOVE ALL MATERIAL MADE OBSOLETE BY THIS WORK. ALL REMOVED EQUIPMENT,
D) FIRE ALARM SYSTEM
MATERIALS AND DEBRIS SHALL BE LEGALLY DISPOSED OF OFF OF SITE IN ACCORDANCE
E) HVAC ROOFTOP UNITS
WITH ALL LOCAL, STATE AND FEDERAL CODES, RULES AND REGULATIONS.
C) THERE SHALL BE NO RIGID CONTACT BETWEEN CONDUIT, PIPES, CEILING WIRES. AND
F) WASHER /DRYER
DUCTWORK.
G) SOUND SYSTEM
D) STRUCTURAL SUPPORT AND FASTENING FOR ALL MECHANICAL AND ELECTRICAL AMENITIES
H) TELEPHONE SYSTEM
FOR BIRD ROOM (DUCTWORK, SPRINKLER PIPING, CONDUIT, ETC.) SHALL BE FROM
I) LIGHTING FIXTURES AND LAMPS
STRUCTURE ABOVE, NOT FROM BIRD ROOM STRUCTURE ITSELF.
J) INTEGRATED POWER &CONTROL ASSEMBLY
3)
DOCU MENTATION
K} PLUMBING FIXTURES
A) DUCTWORK AND PIPING LAYOUTS ARE SCHEMATIC DIAGRAMS AND ARE INTENDED TO SHOW
3)
FUNCTIONAL STANDARDIZATION INCLUDES:
GENERAL ARRANGEMENT, SIZE AND CAPACITY AND DO NOT INDICATE WHICH DUCT OR PIPE
A) AUTOMATIC INDIVIDUAL CONTROL OF HVAC UNITS
IS ABOVE OR BELOW THE OTHER. ALL OFFSETS ARE NOT NECESSARILY SHOWN.
B) AUTOMATIC GROUP CONTROL OF INTERIOR LIGHTING
CONTRACTOR SHALL ARRANGE AND COORDINATE THE WORK, FURNISH NECESSARY OFFSETS
C) AUTOMATIC GROUP CONTROL OF OUTDOOR LIGHTING
AND FITTINGS TO AVOID CONFLICT WITH OTHER MECHANICAL AND ELECTRICAL SERVICES
D) AUTOMATIC GROUP CONTROL OF CERTAIN POWER
AND STRUCTURAL AND ARCHITECTURAL ELEMENTS WITHOUT ADDITIONAL COST TO THE
F.
SPECIAL PURCHASING OR CONTRACTS
OWNER.
1)
GENERAL
B) IF AREAS OF CONFLICT ARE ENCOUNTERED, THE ARCHITECT SHALL BE NOTIFIED AND
REFER TO ARCHITECTURAL DRAWINGS FOR ITEMS NOT NECESSARILY FURNISHED BY
CONTRACTOR'S RECOMMENDATIONS SHALL BE SUBMITTED TO THE ARCHITECT FOR
CONTRACTORS BUT HAVE RELATED RESPONSIBILITIES. THESE ITEMS MUST BE INTEGRATED INTO
APPROVAL BEFORE WORK HAS BEGUN.
THE BUILDING CONSTRUCTION SCHEDULE (ORDERING, SHIPPING, INSTALLING) AS IF THEY WERE
PROVIDED IN TOTAL BY THE CONTRACTOR. REFER TO PROJECT MANUAL FOR PETCO VENDORS'
NAMES, CONTACTS, AND PHONE NUMBERS.
2)
CONTRACTOR PROVIDED / CONTRACTOR INSTALLED
THE FOLLOWING ITEMS ARE FURNISHED BY THE CONTRACTOR THROUGH A NATIONAL ACCOUNT
AGREEMENT BETWEEN PETCO AND THE VENDOR AND INSTALLED BY THE CONTRACTOR:
A) HVAC ROOFTOP UNITS
B) LIGHTING FIXTURES
C) INTEGRATED POWER & CONTROL ASSEMBLY AND LOOSE ELECTRICAL PANELS & CONTROLS.
CODE,
AGENCY, & REFERENCE STANDARDS INFORMATION
A.
GENERAL
1)
ENTIRE INSTALLATION SHALL COMPLY WITH ALL LOCAL AND STATE CODES AND OTHER
AUTHORITIES HAVING JURISDICTION.
2)
THE INSTALLATION SHALL BE IN ACCORDANCE WITH ALL SEISMIC REQUIREMENTS.
3)
WHERE PERMITTED BY CODE, PLASTIC WASTE & VENT PIPING CONFORMING TO IAPMO AND ASTM
MAY BE USED WHEN CONCEALED BELOW FLOOR SLABS OR IN WALLS & PARTITIONS. SUPPORT
PIPING IN ACCORDANCE WITH THE PIPE SUPPORT SCHEDULE OR PER LOCAL REQUIREMENTS,
WHICHEVER IS MORE STRINGENT. NO PLASTIC PIPE MAY BE INSTALLED IN AREAS CONSIDERED
TO BE A PLENUM. PROVIDE PROPER TRANSITION FITTINGS BETWEEN PIPES OF DIFFERING
MATERIAL.
B.
APPLICABLE CODES AND REFERENCES:
1)
ALL STATE AND LOCAL CODES AND ORDINANCES, APPLICABLE EDITION.
2)
NFPA 13 — STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS.
3)
NFPA 54 — NATIONAL FUEL GAS CODE
4)
NFPA 70 — NATIONAL ELECTRICAL CODE
5)
NFPA 90A — AIR CONDITIONING AND VENTILATING SYSTEMS
6)
ASHRAE HANDBOOKS — AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR CONDITIONING
ENGINEERS
7)
SMACNA HANDBOOK FOR DUCT CONSTRUCTION
INTERIOR M®DtFICATIONS ONLY
(ANY iXT[RIOR MODIFICATION MAY REQUIRE
A HOARD APPEARANCE)
MEP Engineer of Record
Randall A. Nelson, P. E.
14817 95th Street
Lenexa, Kansas ••
• _ 913 322 5150
tv
s
�- �vCEIYS�, 0
* No. 65765
STATE OF
ORI�Q�'
p tc •
DISTRIBUTIOR DATE: DISTRmuno k
98% SUBMISSION 12 -0413
100% PERMIT SUBMISSION 12 -11 -13
MAINAM111 Of If • . • My
IDENTIFIER
DESCRP1, SON
i
KEYNOTE SYMBOL
KEYN, WITH :ADER
2 3
MULTIPLE KEYNOTES APPLYING TO THE SAME
ITEM
01
P2,1
DETAIL IDENTIFIER
DETAIL # 01
DRAWING # P2.1 (DWG DETAIL IS LOCATED
ON)
4 P2
SECTION IDENTIFIER
SECTION # 01
DRAWING # P2.1 (DWG DETAIL IS LOCATED
ON)
01
P2.1
ELEVATION IDENTIFIER
ELEVATION # 01
DRAWING # P2.1 (DWG DETAIL IS LOCATED
ON)
AFF
ABOVE FINISHED FLOOR
AFG
ABOVE FINISHED GRADE
BFG
BELOW FINISHED GRADE
BLDG
BUILDING
CLG
CEILING
CONTR
CONTRACTOR
DN
DOWN
DWG(S)
DRAWING(S)
EC
ELECTRIC CONTRACTOR
EM
EMERGENCY
EQUIP
EQUIPMENT
ETR
EXISTING TO REMAIN
EWC
ELECTRIC WATER COOLER
EX
EXISTING
FLA
FULL LOAD AMPS
FS
FLOW SWITCH
GC
GENERAL CONTRACTOR
GWB
GYPSUM WALL BOARD
HP
HORSEPOWER
MC
MECHANICAL CONTRACTOR
MCA
MINIMUM CIRCUIT AMPS
MFR
MANUFACTURER
MH
MOUNTING HEIGHT
MOD
MOTOR OPERATED DAMPER
NIC
NOT IN CONTRACT
NTS
NOT TO SCALE
OG
ON CENTER
PC
PLUMBING CONTRACTOR
PSI
POUNDS PER SQUARE INCH
PVC
POLYVINYL CHLORIDE
RPM
REVOLUTIONS PER MINUTE
SDD
DUCT SMOKE DETECTOR
SO. FT.
SQUARE FEET
TYP
TYPICAL
'a • �IE :1L r - : •
iIcy* -^
:7�t4Q�3•3Tlfiil "�
`I