10-76R-004ANCHOR STRAPS i 12" 0 BOLT DOWN MANHOLE LID OVER INTERSTITIAL SENSOR FDEP APPROVED OR EQUALS, r _ � � 1 ❑A STAGE 1 VAPOR RECOVERY RISER WITH PLUG AND MANHOLE, FEDP- APPROVED EQUAL DOUBLE WALL SPILL CONTAINMENT BUCKET WITH DRAIN VALVE (TYP.) OVER FILL RISER 5000 GALLON PLU DOUBLE WALL SPILL CONTAINMENT BUCKET WITH DRAIN VALVE (TYP.) OVER FILL RISER - -FEDP- APPROVED EQUAL 1 STAGE 71 VAPOR RECOVERY RISER WITH PLUG AND MANHOLE, FEDP- APPROVED EQUA� ~� OLYDDiVIV MANHOLE LID OVER VEEDER -ROOT MAG -1 TANK GAUGE PROBE FDEP APPROVED OR EQUAL 42" DIAMETER FIBERGLASS STP SUMP �- FDEP APPROVED OR EQUAL A��G ,t TO P NSER I� � III,I I UI -37' -0 1/2" PLAN VIEW SCALE: 3/8 " =1' -0" C DOUBLE WALL SPILL CONTAINMENT BUCKET WITH DRAIN VALVE (TYP.) OVER FILL RISER FEDP- APPROVED EQUAL 1 STAGE 1 VAPOR RECOVERY RISER WITH PLUG AND MANHOLE, j - FEDP - APPROVED EQUAL 12" BOLT DOWN MANHOLE LID OVER VEEDER -ROOT MAG -1 TANK GAUGE PROBE FDEP APPROVED OR EQUAL 42" DIAMETER FIBERGLASS STP SUMP F EP APPROVED OR EQUAL I I I � / I 7,000 GALLON SUPER TO DISPENSER 39" DIA COMPOSITE MANHOLE COVER FDEP APPROVED OR EQUAL (TYP. OF 2 PLCS) LEAK DETECTOR FDEP APPROVED OR EQUAL (TYP. OF 2 PLCS) 1 1/2" H.P. SUBMERSIBLE PUMP FDEP APPROVED OR EQUAL (TYP. OF 2 PLCS) FEDP - APPROVED EQUAL 12" BOLT DOWN MANHOLE LID OVER VEEDER -ROOT MAG -1 TANK GAUGE PROBE CONCRETE TO BE CROWNED 1 1/2" 12 0 BOLT DOWN MANHOLE LID FDEP APPROVED OR EQUAL AT ALL SLAB PENETRATIONS (TYP.) OVER 1NTERSTITIAL SENSOR FDEP APPROVED OR EQUAL WEATHER PROOF J -BOX PER NFPA SPEC. (TYP.) 2' -0" EXISTING PAVEMENT MIN. .� GALV. RISER WRAPPED WITH 4" A� 10 MIL 3M TAPE ,:� BACKFILL SHALL CONSIST OF CLEAN SAND, sRO. PEA GRAVEL OR #a CRUSHED STONE � a" CONCRETE TANK SLAB REINFORCED 1 Q WITH 6X6X1.4 W.W.M. do #5 RFBAR AT EACH MW� 1 2' -0„ �-- MIN. EXISTING PAVEMENT �• _ w SHEET PILE BY GC g IF REQUIRED � Q „ 'ALV. RISER WRAPPED WITH 4 2" DOUBLEWALL FIBERGLASS 2 FULL PORT BALL VALVE 10 MIL 3M TAPE -PRODUCT PIPING (TYP. OF 2 P CS) (TYP. OF 2 PLCS) NEW EXTRACTOR -� f DEP APPROVED OR EQUAL _T BALL FLOAT VENT VALVESET TO 95% OF � TANK CAPACITY FDEP - APPROVED OR EQU COLLAR r i D4 D4 D i SUMP SENSOR PRODUCT LEVEL PRODUCT �EVEL ` � I , I ;II I I EXISTIING DOUBLE WALL VENT PIPING C EXCAVATION LINED V DER- OI I MAG -1 Q r �� TA GAUL PROB TYPj OF 2 PLCS W/ FILTER FABRIC SUBMERSIBLE :o ! ; NEW DROP TUBE (' TURBINE PUMP WITH i SET TOV95%.LOFPT� KCCAPACITYC I � i � � J/ X. A J I i ANCHOR STRAPS t FDEP APPROVED b R EQUAL I J. (TYP. OF 2 PAC) I /� ro i' o (� o �•u \ III I � � \ - -- — — — - - - - -- EXCAVA TI ON TO BE SLOPED BENC H ED OR SHEET PILED IN ACCORDANCE WITH OSHA 29 CFR 1926 -950(P) , i METHOD OF COMPLIANCE TO BE DETERMINED BY CONTRACTOR MIN 12" BED OF CLEAN SAND, PEA GRAVEL OR #M CRUSHED STONE UNDER TANK 37' -0 1/2" TANK SECTION SCALE: 3/8"=V-0" 0" i CONCRETE DEADMAN ANCHOR 14 "H x 18"W x LENGTH OF TANK PLUS 3 FEET (TYP 2 PER TANK) CONTAINMENT SOLUTIONS FDEP APPROVED OR EQUAL 12,000 GALLON DOUBLE WALL MULTICOMPARTMENTED UNDERGROUND STORAGE TANK 5,000 DIESEL & 71000 SUPER I _ D � Z LIJ " • u Y • r r • • y 0 4 • • •r•i• } • • • V i • • i • Y • • i • Y • .... • ..... ... .•.. z • O • i • • •iir • u•••• • • • z ir• • •ir• • O � f7_ w U W D c.) F- w 0 LL) 5 w Of W o O Z ., 13T OF � � SOUTH r,�Ia�t 1 El ,JILDING DEPT. i,TRUCTURAL SECTION .,'PROVED BY:, . _ �.r.......„.w RIO 0 rte' 16raw'j ctxo.�r� William S. Evans, Jr. President /Owner .960 East 10th Ct., Hialeah, FL 33013 Phone 305 -6$7 -7760 Fix 305 - 667 -1272 CMCO- 57430 •PCCCO- 46044•CMCO -42536 Z M O M M Q D O LL VJ ♦^ Q � z � W 0 w \ D � Z LIJ " Z0 ME C-1 ME O L7 ■ L7 C C�J ty !• i • tl -3 •��� A BBEI, P -E.# 22'2 00 li J U U) ti 04 T_ W r ■