Loading...
10-76R-002GRAPHIC SCALE -10' 0' 5' 10' 20' (3) EXISTING VENT RISERS TO REM0 AND TO BE RE -USE[ W D z W c N VJ 'a Iw O ol IM 'O I ZI I SW 72nd STREET (SUNSET DRIVE) 150.38' EAST �1J_LJ_L L� EXISTING MW TO REMAIN (TYP.) ~= EXISTING CONCRETE PAVEMENT) TO REMAIN - EXISTING�ASPHALT PAWEK�ENT Td' REMAIN, I I _ i I ' 1� _ l I 175.12' LOT 11 -J EXISTING CANOPY TO REMAIN ,,-------4(4) EXISTING DISPENSER ISLANC EXISTING DOUBLE WALL PRODUCT PIPING I EXIST i (4) EXISTING MULTI - PRODUCT DISPE co I r r W IF co M O O cn •••i •1i Y • •i••• wu• • i • r• • Y • Y r see ♦ • t f • Y r • SCOPE OF WORK r ir• • • • • • • i i • • . i . i • INSTALL (1) NEW CONTAINMENT SOLUTIONS FIBERGLASS 12,000 GALLON DOUBLEWALL ' : r : : (SEE DETAILS ON SHEET G -2) " ' ••• •• • :• ••• INSTALL (1) NEW CONTAINMENT SOLUTIONS FIBERGLASS FDEP APPROVED OR EQUAL 12,000 j A1ICON COMPARTMENTED DOUBLEWALL FUEL STORAGE TANK 7,000 do 5,000 GALLON SPLIT (SEE DETAILS ON SHEET G -3) i i • t. J INSTALL (3) NEW 42" DIA. STP SUMPS WITH LIQUID SENSORS UNDER 39" DIA. COMPOSITE MANFTOLE• CbM�. " i "' i r •" r • (SEE DETAILS ON SHEET G -2 THRU G -4) INSTALL (3) NEW RED JACKET 3/4 h.p. SUBMERGED TURBINE PUMPS WITH CONTROL BOXES AND ELECTRONIC PRESSURE LINE LEAK DETECTORS (SEE DETAILS ON SHEET G -2 THRU G -4). O INSTALL (3) NEW 4 "0 SCH. 40 GALV RISER W/ OVERSPILL PREVENTION VALVE, FILL ADAPTER & OPW #1 15 GAL. SPILL CONTAINER BUCKET. (SEE DETAIL ON SHEETS G -2 THRU G -4) INSTALL 4 "0 SCHED. 40 GALV. STAGE 1 VAPOR RECOVERY RISER WITH EXTRACTOR AND BALL FLOAT VENT VALVE (SEE DETAILS ON SHEET G -2). C INSTALL 3) NEW MAGNETOSTRICTIVE TANK GAUGE PROBES IN 4 "0 SCHED. 40 GALV. RISERS (SEE DETAIL ON SHEETS G -2 THRU G -4). INSTALL (2) NEW INTERSTITIAL SENSORS IN 4 "0 SCHED. 40 GALV. RISERS (SEE DETAIL ON SHEETS G -2 THRU G -4). 9 BACK FILL EXCAVATED AREAS WITH CLEAN, WELL - COMPACTED, APPROVED BACK FILL MATERIAL. Q 10 PLACE AND FINISH NEW a" CONCRETE AT TANK SLAB WITH 6X6X1.4 W.W.M. do #5 REBAR AT EACH MANWAY SEE DETAIL ON SHEET G--4) �11 INSTALL (a) NEW 2 MONITORING WELLS. (SEE DETAIL ON SHEET G -4).� 12 STARTUP ALL SYSTEMS, PURGE ALL PRODUCT LINES, AND CALIBRATE ALL DISPENSERS. NOTES: 1. ALL NEW COMPONENTS AND MATERIALS MUST BE F.D.E.P. APPROVED. 2. CONTRACTOR TO ENSURE WARNING SIGNS ARE PROPERLY DISPLAYED IN ACCORDANCE WITH 9.2.54 NFPA 30A 2000 ED. AND THAT SIGNS CONTAIN THE FOLLOWING OR EQUIVALENT WORDING: WARNING IT IS UNLAWFUL AND DANGEROUS TO DISPENSE GASOLINE INTO UNAPPROVED CONTAINERS. NO SMOKING. STOP MOTOR. NO FILLING OF PORTABLE CONTAINERS IN OR ON A MOTOR VEHICLE. PLACE CONTAINER ON THE GROUND BEFORE FILLING. DISCHARGE YOUR STATIC ELECTRICITY BEFORE FUELING BY TOUCHING A METAL SURFACE AWAY FROM THE NOZZLE. DO NOT RE -ENTER YOUR VEHICLE WHILE GASOLINE IS PUMPING. IF A FIRE STARTS, DO NOT REMOVE NOZZLE BACK AWAY IMMEDIATELY. DO NOT ALLOW INDIVIDUALS UNDER LICENSE AGE TO USE THE PUMP. 3, ALL WORK TO COMPLY WITH THE FOLLOWING CODES: -- FLORIDA BUILDING CODE, 2004 ED, - NFPA -1, 2003 ED. - NFPA 30, 2000 ED. - NFPA 30A, 2000 ED. - NFPA 70, N.E.C., 2002 ED. - FLORIDA FIRE PREVENTION CODE, 2004 ED. MONITORING WELL LEGEND = NEW 2" MONITORING WELL NEW COMPLIANCE WELLS TO BE LOCATED TO A MIN. OF 25' FROM ANY BEND IN THE PIPING AND 10' FROM DISPENSER SUMP NO STAGE II VAPOR RECOVERY SYSTEM TO BE INSTALLED AT PROPOSED FUEL SYSTEM c tTy ov: S DAP A.Nt� BU! ,TRUCTU AL FGT�Q qI CD z a. a 0 z F- Q C/) z W z © a 00 W � c) C/) W W O ❑ W W cn w W rr � � W O F- Z Q CV �— O 04 I RIO O Er(-,) (6WIn'4 tXC�/rcrm, William S. Evans, Jr. President /Owner 960 East 10th Ct., Hialeah, FL 33013 Phone 305 -687 -7760 Fix 305 - 687 -8272 CBCO -57480 • PCCC0 46044 • CMCO- -42536 !I AL EB$�> ,. 3F7,0 W cn W cn c W U— 7Gm-% - 0 0 l l w J Q U U) O O ti N T_ W H