Loading...
10-451-002CONSTRUCTION DOCUMENT DOTES 1, THESE PRINTS ARE AN INSTRUMENT OF SERVICE ONLY. ALL IDEAS, DESIGN AND ARRANGEMENTS INDICATED ARE THE PROPERTY OF ARCHITECT OF RECORD 2. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. ` 3. CONTRACTOR SHALL VISIT THE JOB SITE, VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS OF THE PROJECT. ARCHITECT OF RECORD MUST BE NOTIFIED BY THE CONTRACTOR OF ANY CONDITIONS NOT SHOWN ON THESE DRAWINGS. 4. CONTRACTOR SHALL PROMPTLY NOTIFY ARCHITECT OF RECORD IN WRITING OF THE EXISTENCE OF ANY OBSERVED VARIATIONS BETWEEN THE CONTRACT/ GONSTRUGTION DOCUMENTS AND /OR ORDINANCES OF REGULATORY AGENCIES. ERRORS, AMBIGUITIES AND /OR OMISSIONS, RETURN TO ARCHITECT OF RECORD FOR CORRECTION BEFORE ANY PART OF THE WORK IS STARTED. 5, CONTRACTOR SHALL SUPPLY DETAILS OF WINDOWS, DOORS AND GARAGE DOORS GENERAL CONSTRUCTION NOTES 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS ON JOB PRIOR TO BEGINNING CONSTRUCTION. 2. ALL DETAILS, SECTIONS AND NOTES SHOWN ON THESE DRAWINGS ARE INTENDED TO BE TYPICAL 4 SHALL APPLY TO 51MILAR SITUATIONS ELSEWHERE UNLESS OTHERWISE SHOWN. 3. PRELIMINARY TRU55 ENGINEERING MUST BE 51,15MITTED TO ARCHITECT FOR APPROVAL PRIOR TO POURING ANY SLAB OR FOOTINGS. 4. ALL PRODUCTS 4 MATERIALS SHALL BE APPLIED OR INSTALLED ACCORDING TO MANUFACTURER'5 SPECS. 5, ALL CONCRETE WORK SHALL COMPLY WITH LATEST EDITION OF THE ACI BLDG CODE (ACI 318 -99), AND (ACI 301 -99)_ ALL CONCRETE MASONRY WORK SHALL BE IN ACCORDANCE WITH (ACI 530 -99) 6, ALL CONCRETE SHALL CONFIRM TO A5TM C94 -94 AND SHALL HAVE 3000 PSI FOR SLABS ON GRADE 4 3000 P51 FOR BEAMS, COLUMNS, 4 CELLS AT 28 DAYS. 1, FOUNDATIONS WERE DESIGNED FORA SOIL BEARING CAPACITY OF 2500 P5F TH15 CONDITION MUST BE CERTIFIED TO BE 50 BY A 501L TESTING LABORATORY WITH THE RESULTS SUBMITTED TO ENGINEER ON RECORD FOR APPROVAL PRIOR TO ANY FOOTING OR FOUNDATION SYSTEM INSTALLATION. 8. ALL FILL SHALL BE COMP. TO A MIN. OF 95% DENSITY 4 TERMITE TREATED FOR A D15TANCE OF A 5' -0" FROM PERM, OF ALL FTGS, OR 5LA5 EDGES. 9, FLOOR SLAB SHALL BE 4' THICK, POURED CONCRETE SLAB W/ 6x(o1W14XW14 /W.WJ`i. ON 0.004 VISQUEEN PLASTIC OR EQUEL VAPOR BARRIER, ON WELL TAMPED, TERMITE TREATED SAND FILL (VIBRO- COMPACTED). AS PER FBG 320.1 OR AS NOTED ON PLANS 10. WELDED WIRE FABRIC SHALL COMPLY W/ ASTM A 185, UNLESS OTHERWISE SPECIFIED PLACE FABRIC 2" CLEAR FROM TOP OF THE SLAB IN 5LA15 ON GRADE. 11, ALL REINFORCING STEEL SHALL BE GRADE 60. OR A5 NOTED ON PLAN 12, CONCRETE COVER FOR REINFORCING STEEL SHALL MEET LATEST ACI SPECIFICATION. ALL REINFORCING STEEL 5HALL BE MANUFACTURED FROM NIGH STRENGTH BILLET STEEL CONFORMING; TO A5TM A 185. LAP ALL BARS MIN. 48 BAR DIAMETERS UNLESS OTHERWISE NOTED ON DRAWING5. LAP ALL WWF A MIN. OF b'. UNLESS OTHERWISE NOTED, 13. PROVIDE ONE 15 X 4'0" BENT BAR FOR EA. HORIZONTAL BAR SCHEDULED AT THE OUTSIDE FACE OF CORNERS OF CONC. WALLS, BEAMS, 4 CONTINUOUS WALL FOOTING, ALL HOOKS SHOWN IN REINFORCEMENT SHALL BE AC1 RECOMMENDED HOOKS UNLESS OTHERWISE NOTED. 14. ALL STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE W/ THE LATEST 415C CODE. STRUCTURAL STEEL SHALL CONFORM TO A5TM SPECIFICATION A 36. ALL STEEL TUBING SHALL CONFORM TO A5TM SPECIFICATION A 500 GRADE 5(Fy =4(o K51). ALL STEEL TO HAVE SHOP 4 FIELD WELDING PERFORMED BY WELDERS QUALIFIED AS DESCRIBED IN AMERICAN WELDING SOCIETY'5 STANDARD QUALIFICATION PROCEDURE (A5WD1.1). ALL STEEL WELDING RODS SHALL BE E10XX ELECTRODES. 15. ALL MASONRY UNITS SHALL BE ASTM C 90 -90 GRADE NI OR NII W/ MIN. COMPRESSIVE OF 1500 STRENGTH P51 ON NET AREA OF INDIVIDUAL UNITS, ALL CMU SHALL BE LAID IN A FULL BED OF MORTAR IN RUNNING BOND U.ON. 16, ALL MORTAR SHALL BE TYPE IN ACCORDANCE W/ A5TM SPECIFICATION C270 -92 W/ A MIN, COMPRESSIVE STRENGTH OF 1800 PSI AT 28 DAYS (2500 w/ TYPE M). 17, GROUT SHALL BE A HIGH SLUMP MIX IN ACCORDANCE W/ A5TM SPECIFICATION 0476 HAVING A MIN. COMPRESSIVE STRENGTH OF 3000 PSI. IS. USE HORIZONTAL JOINT REINFORCEMENT AT EVERY COURSE w/ *8 LADDER TYPE FOR REINFORCED MASONRY 4 TRUS5 TYPE FOR ALL OTHERS. 19, ALL CONCRETE MASONRY BEARING AND SHEAR WALLS SHALL BE CONSTRUCTED IN ACCORDANCE W/ THE "SPECIFICATION FOR THE DE51GN 4 CONSTRUCTION OF LOAD BEARING CONCRETE MASONRY" PUBLISHED BY NAT'L CONCRETE MASONRY ASSOCIATION, 20. STRUCTURAL TIMBER TO BE DOUGLAS FIR OR 5YP *2 (MIN) STRESS GRADE LUMBER OR APPROVED EQUAL. THE MINIMUM ALLOWANCE PROPERTIES ARE Fb= 1,400 P51 Fv= 90 PSI, E= 1,400,000 P51, 4 PRESSURE TREATED FOR EXTERIOR USE. 21. ALL WOOD IN CONTACT WITH MASONRY OR CONG, 5HALL BE PRESSURE TREATED. 22. ALL TIMBER 4 TIMBER CONSTRUCTION SHALL COMPLY W/ SPECIFICATIONS 4 CODES SPECIFIED BY THE FOLLOWING: AMERICAN INSTITUTE OF TIMBER CONSTRUCTION, TIMBER CONSTRUCTION MANUAL,*- NAT'L FOREST PRODUCTS ASSOC., NAT'L DESIGN SPECIFICATION FOR WOOD CONSTRUCTION± AMERICAN PLYWOOD A550C., PLYWOOD DESIGN SPECIFICATION* AMERICAN WOOD PRESERVERS A550C. 5TANDARD5 NAT'L LUMBER MANUFACTURERS ASSOC., NAT'L DESIGN SPECIFICATION FOR STRESS GRADE LUMBER 4 ITS FASTENINGS. 23, ALL TIMBER CONNECTIONS ARE TO BE MADE USING PREFABRICATED CONNECTORS. TOE NAILING WILL NOT BE PERMITTED. SUBMIT MANUFACTURER'S DATE FOR APPROVAL. 24, WOOD BEARINGS PARTITION 2X4 OR 2X6 Q MAX. SPACING 16' O.G. WITH BRACING 4'- 0' O.C. V. lk� u 25. ALL WOOD BEARING WALLS ENDING AT AN EXTERIOR WALL SHALL BE ATT CHED TO THE EXTERIOR WALL w/ A P.T. STARTER "2 -BY' SHOT INTO THE 4 -5AR COL. w/ 3' PINS 0Y O.C, 26. ALL WOOD BEARING WALLS SHALL TERMINATE WITH (3) NAILED 2x 5TUD5. 21. PARTITION WALLS TO BE METAL STUDS AT 24' O.G. 26. ALL GUY GREY BOXES IN FIRE RATED WALLS TO BE MADE OF STEEL OR FRAMED ON REAR SIDE AND COVERED WITH 5/8' TYPE 'X' GYP. BOARD. 29. FIRE STOPS TO BE PROVIDED IN ALL FURRED SPACES 0 V -0' O.G. 30. TIE BEAMS ARE TO BE CONTINUOUS AS PER CODE, AND MIN. Vx12', EXTENDING MIN, V OVER SUPPORT ENDS (12" AT GARAGE OPENINGS). OR AS NOTED ON PLANS 31. THE TIE BEAM SCHEDULE DEPTHS ARE MINIMUM AND MAY BE INCREASED (S" MAXIMUM) TO FIT BLOCK WORK. , 32. TIE BEAM, PLATE, SOFFIT 4CEILING HEIGHTS ARE TAKEN FROM FINISHED FLOOR SLAB 33. FIRST BLOCK CAVITY AT EACH SIDE OF OPENINGS SHALL BE FILLED W/ CONCRETE UNLESS SHOWN OTHERWISE. 34, ALL WINDOWS (GLASS BLOCK, FIXED GLA55 4 OPERABLE UNITS) AND DOO 5 4 THEIR ASSEMBLIES SHALL MEET THE REQUIREMENTS SET FORTH CODE (E) OR BE PROVEN TO BE ACCEPTABLE BY SEPARATE ENGINEERING. 35. SILL AND BASE PLATES TO BE ATTACHED TO CONCRETE WITH 1/2' ANCHOR BOLTS WITH MIN, 7' EMBEDMENT U.N.O, 36. ALL FIXED GLASS THICKNESS TO BE BY SEPARATE ENGINEERING, 31, ALL EGRESS WINDOWS NOTED 'E " SHALL MEET THE FOLLOWING REQUIREMENTS: CLEAR OPENING OF NOT LESS THAN 20" IN WIDTH, 24' IN HT,, 4 5.1 SOFT. IN AREA. THE BOTTOM OF THE OPENING SHALL BE NOT MORE THAN 44' A.FF. 'EGRESS" WINDOWS SHALL CONFORM TO CODE. 38, SLIDING GLA55 DOORS 4 FRENCH DOORS SHALL HAVE TEMPERED 6LA55. ALL WINDOWS AND SLIDING DOORS TO HAVE INSECT SCREENS. 39. FIRE 5TOP5 REQUIRED AROUND: TOP, BOTTOM 4 SLIDING; DOOR POCKE S. 40. ALL EXTERIOR TYPE SWING DOORS TO HAVE A METAL THRESHOLD. 41. ALL DETAILS, PRODUCT APPROVALS 4 NOTES SHOWING SHUTTER CONNECTIONS 4 ASSEMBLIES SHALL BE PROVIDE -D BY THE BUILDER/CLIENT. SHUTTERS ARE MANDATORY UNLESS SEPARATE ENGINEERING, PROVIDED BY THE SAME PARTY, ACCOMPANIES PLAN WITH PROOF OF OTHER METHODS DEEMED TO COMPLY WITH F.B.C. 42. SCREEN ENCLOSURE5 TO BE UNDER SEPARATE PERMIT WHERE 5GREEN ENCLOSURE 15 TO BE ATTACHED TO FASCIA, IT MUST BE ATTACHED TO THE TRU55E5 BY 5OUTHEA5TERN METALS REGULAR 206A. ANCHORS, W/ (4) 8d NAILS INTO THE TOP OF THE FASCIA, AND (4) ad NAILS INTO THE SIDE OF THE RAFTER (ONE ANCHOR PER RAFTER), TO RESIST 1000 lbs, UPLIFT AS PER CODE. 43. BATHROOM 4 TOILET ROOM FLOORS 4 BASE TO BE OF IMPERVIOUS MATERIALS. 44. ALL GLA55 IN BATHROOMS TO BE TEMP BELOW 60' AFF. 45. ALL SHOWER ENCLOSURE GLASS TO BE CAT II SAFETY GLAZING PER CODE, 46. ALL WINDOW FRAMES TO BE SET IN CAULK BEDS. 41. SCREEN SPRINKLER, POOL, AND A/C EQUIPMENT FROM VIEW. 48. ELEVATIONS ARE TAKEN FROM LOWEST LIVING AREA FIN.FLOOR 5LA5 WHICH SHALL BE 0' -0'. 49. PENETRATIONS OF RATED WALLS AND FLOORS SHALL BE SEALED W/ A MATERIAL CAPABLE OF PREVENTING THE PA55AGE OF FLAME5 AND HOT GA55E5 WHEN SUBJECTED TO THE REQUIREMENT5 OF THE TEST STANDARD SPECIFIC FOR FIRE STOPS, 50, ALL WATER CLOSETS, LAVATORIES, SHOWER HEADS, URINALS AND SUCH SHALL COMPLY W/ CODE. 51. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CODE. 52. THE' SUPPORTING' STRUCTURE HAS BEEN DESIGNED FOR THE`FORCES SHOWN ON THE APPROVED MANUFACTURER'S DRAWINGS FOR GARAGE DOORS. 53, ALL WD. HDR'5 IN BEARING WALLS TO BE DONE BY RATIONAL ANALYSIS. ti SYMBOLS &ABBREVIATIONS ARCHITECTURAL _ 0 WINDOW NUMBER NORTH ARROW j�� ( ) DOOR NUMBER I BUILDINCz SECTION �J A- REFERENCE DRAWING NUMBER j WALL SECTION OR ELEVATION A- REFERENCE DRAWING NUMBER 1 DETAIL Q- REFERENCE DRAWING NUMBER ROOM /SPACE NUMBER EQUIPMENT NUMBER PLUMBING ZN LOUD SPEAKER --- -- WATER CL05ET HOT WATER • © ELECTRICAL DOOR T p RELEASE COLD WATER 2' X ,4' FLUORESCENT SOIL LINE FIXTURE F FIRE ALARM BELL ( BIDET L_ D DRAIN LINE _/ -- - - -- -- VENT 2' X �' MUSIC FLUORESCENT GAS LINE URINAL r FIXTURE W/ EMER. BATTERY PACK. � TEL. SWITCHBOARD �B HOSE 01515 rxx FLUORESCENT O LAVATORY O z FIXTURE CLOCK GO CLEAN OUT BATHTUB 2 - 40W FLUORESCENT SOUND SYSTEM FD FLOOR DRAIN STRIP FIXTURE I -40W ® SHOWER FLUORESCENT -� MICROPHONE STRIP FIXTURE EWH WATER HEATER TELEPHONE PANEL CITY QF S0LJ 1�1-i ,y ,J�`:�I ! � DEFT. ELECTRICAL PANEL BUILDING �''�`-. . wCT10N BUILDING SEC"i ,,.., -. APPROVED BY, DATE: ABBREVIATIONS MECHANICAL A.F.F. ABOVE FINISH FLOOR PART. PARTITION WALL FINISH (CONT'D) A.G. AIR CONDITIONINdl, '1, '40L. PLATE ALUM. ALUMINUM RECPT. RECEPTACLE MTL. METAL BLDG. BUILDING REFL. REFLECTED MA. MARBLE BLK'G. BLOCKING REFRG, REFRIGERATOR CEILING DIFFUSER WALL REGISTER 5". PRA55 REINF, REINFORCE WINDOW TREATMENT RETURN OR SUPPLY )BR. BRONZE SECT. SECTION 1 CLG. CEILING SHT. SHEET PL PLASTIC (7-: CENTERLINE F.5-C. FLORIDA LAMINATE CEILING DIFFUSER, CONC. CONCRETE BUILDING 5 BLINDS W/ BAFFLE CONT. CONTINUOUS CODE VB VERTICAL t THEMOSTAT w DED DEDICATED BLINDS 5'_0� AFF D.F. DRINKING FOUNTAIN STL. STEEL D DRAPERY EF ELEC, ELECTRIC TEL. TELEPHONE 5 SHADES RETURN AIR i © EXHAUST FAN ELEV. ELEVATION TEMP, TEMPERED ACT ACOUSTICAL EX15T'G. EXISTING TYP, TYPICAL CLG. TILE EE F.E. FIRE EXTINGUISHER VERT. VERTICAL E5 EXPOSED F.F. FIN15H FLOOR WSCT. WAINSCOT SPLINE FAN/LIGHT COMBINATION G.C. GENERAL CONTRACTOR WD. WOOD CS CONCEALED LINEAR DIFFUSER GLS. GzLASS SPLINE HOL, HOLLOW FLOORING MP METAL PIN ® FIRE DAMPER HORIZ. HORIZONTAL SP SPRAYED t INT. INTERIOR AT ASHPALT TILE PH PLASTER JT. JOINT VT VINYL TILE HUNG FIRE SPRINKLER LAV. LAVATORY VCT VINYL COMpOS, EC EXISTING LT. LIGHT VCT TILE CEILING: MAX. MAXIMUM G CARPET MIN, MINIMUM CT CERAMIC TILE MTL. METAL QT QUARRY TILE WALL FINISH N,I.G. NOT IN CONTRACT T TILE N.T,S, NOT TO SCALE M MARBLE WC WALLCOVERINCx E O,C. ON CENTER CK CORK TILE P PAINT /STAIN j I OP'G. OPENINra WD WOOD WD WOOD I EX EXISTING MI MIRROR ELECTRICAL E.M.M. � WALL SCONCE r 120V DUPLEX RECEPTACLE 1' - ra' AFF DATE FIXTURE acAL AS NOTED JOB. ND, WALL MTD. U • • u QUADROPLEX RECEPTACLE Y 1-( }- YYY INCANDESCENT FIXTURE S SWITCHED RECEPTACLk Y CEILING MTD, INCANDESCENT G SIMPLEX RECEPTACLE a FIXTURE SPECIAL PURPOSE RECESSED INCANDESCENT RECEPTACLE RECEPTACLE 1 DOWN LIGHT O FLOOR MTD. RECEPTACLE WALL WASH SPECIAL PURPOSE FLOOR RECEPTACLE FLOOD LIGHT RECESSED TELEPHONE OUTLET • • INCANDESCENT WALL WASH DEDICATED TELEPHONE OUTLET Y • FLOOD LIGHT WALL MTD. W TELEPHONE OUTLET EMERC ENCY CONDUIT TO E50X FOR FUTURE EXIT LIGHT W/ BATTERY • •!• feel, PACK FLOOR MTD. TELEPHONE OUTLET Q EXIT LIGHT ! SWITCH SINGLE POLE �J [V] W/ 5TRO5E ��r SWITCH - TYPE EXIT LIGHT T - I 1,2 3 INDICATED BY "$ i AND ARROW I�r - DIMMER SWITCH I D MULTIGANCs SWITCH PLATE BELL JUNCTION BOX BUZZER r-1-G. OR FLOOR JUNCTION BOX IN WALL 0+ FIRE CONTROL 5Y5TEM FAN OUTLET .CODE ALARM ARCHITECTURAL _ 0 WINDOW NUMBER NORTH ARROW j�� ( ) DOOR NUMBER I BUILDINCz SECTION �J A- REFERENCE DRAWING NUMBER j WALL SECTION OR ELEVATION A- REFERENCE DRAWING NUMBER 1 DETAIL Q- REFERENCE DRAWING NUMBER ROOM /SPACE NUMBER EQUIPMENT NUMBER PLUMBING ZN LOUD SPEAKER --- -- WATER CL05ET HOT WATER • © ELECTRICAL DOOR T p RELEASE COLD WATER 2' X ,4' FLUORESCENT SOIL LINE FIXTURE F FIRE ALARM BELL ( BIDET L_ D DRAIN LINE _/ -- - - -- -- VENT 2' X �' MUSIC FLUORESCENT GAS LINE URINAL r FIXTURE W/ EMER. BATTERY PACK. � TEL. SWITCHBOARD �B HOSE 01515 rxx FLUORESCENT O LAVATORY O z FIXTURE CLOCK GO CLEAN OUT BATHTUB 2 - 40W FLUORESCENT SOUND SYSTEM FD FLOOR DRAIN STRIP FIXTURE I -40W ® SHOWER FLUORESCENT -� MICROPHONE STRIP FIXTURE EWH WATER HEATER TELEPHONE PANEL CITY QF S0LJ 1�1-i ,y ,J�`:�I ! � DEFT. ELECTRICAL PANEL BUILDING �''�`-. . wCT10N BUILDING SEC"i ,,.., -. APPROVED BY, DATE: ABBREVIATIONS MECHANICAL A.F.F. ABOVE FINISH FLOOR PART. PARTITION WALL FINISH (CONT'D) A.G. AIR CONDITIONINdl, '1, '40L. PLATE ALUM. ALUMINUM RECPT. RECEPTACLE MTL. METAL BLDG. BUILDING REFL. REFLECTED MA. MARBLE BLK'G. BLOCKING REFRG, REFRIGERATOR CEILING DIFFUSER WALL REGISTER 5". PRA55 REINF, REINFORCE WINDOW TREATMENT RETURN OR SUPPLY )BR. BRONZE SECT. SECTION 1 CLG. CEILING SHT. SHEET PL PLASTIC (7-: CENTERLINE F.5-C. FLORIDA LAMINATE CEILING DIFFUSER, CONC. CONCRETE BUILDING 5 BLINDS W/ BAFFLE CONT. CONTINUOUS CODE VB VERTICAL t THEMOSTAT w DED DEDICATED BLINDS 5'_0� AFF D.F. DRINKING FOUNTAIN STL. STEEL D DRAPERY EF ELEC, ELECTRIC TEL. TELEPHONE 5 SHADES RETURN AIR i © EXHAUST FAN ELEV. ELEVATION TEMP, TEMPERED ACT ACOUSTICAL EX15T'G. EXISTING TYP, TYPICAL CLG. TILE EE F.E. FIRE EXTINGUISHER VERT. VERTICAL E5 EXPOSED F.F. FIN15H FLOOR WSCT. WAINSCOT SPLINE FAN/LIGHT COMBINATION G.C. GENERAL CONTRACTOR WD. WOOD CS CONCEALED LINEAR DIFFUSER GLS. GzLASS SPLINE HOL, HOLLOW FLOORING MP METAL PIN ® FIRE DAMPER HORIZ. HORIZONTAL SP SPRAYED t INT. INTERIOR AT ASHPALT TILE PH PLASTER JT. JOINT VT VINYL TILE HUNG FIRE SPRINKLER LAV. LAVATORY VCT VINYL COMpOS, EC EXISTING LT. LIGHT VCT TILE CEILING: MAX. MAXIMUM G CARPET MIN, MINIMUM CT CERAMIC TILE MTL. METAL QT QUARRY TILE WALL FINISH N,I.G. NOT IN CONTRACT T TILE N.T,S, NOT TO SCALE M MARBLE WC WALLCOVERINCx E O,C. ON CENTER CK CORK TILE P PAINT /STAIN j I OP'G. OPENINra WD WOOD WD WOOD I EX EXISTING MI MIRROR I t:. � 1 E.M.M. G:HECKF D r W.H.F. DATE t acAL AS NOTED JOB. ND, 10 -0011 U • • u Y a Y Y •• •• • ! Y • • G a W REV I 1 • ••Y • 00 c • • • • • • • Y • • • • •!• feel, .r ••• r • • ! t� A • • • i • i i ARCHITECTURAL _ 0 WINDOW NUMBER NORTH ARROW j�� ( ) DOOR NUMBER I BUILDINCz SECTION �J A- REFERENCE DRAWING NUMBER j WALL SECTION OR ELEVATION A- REFERENCE DRAWING NUMBER 1 DETAIL Q- REFERENCE DRAWING NUMBER ROOM /SPACE NUMBER EQUIPMENT NUMBER PLUMBING ZN LOUD SPEAKER --- -- WATER CL05ET HOT WATER • © ELECTRICAL DOOR T p RELEASE COLD WATER 2' X ,4' FLUORESCENT SOIL LINE FIXTURE F FIRE ALARM BELL ( BIDET L_ D DRAIN LINE _/ -- - - -- -- VENT 2' X �' MUSIC FLUORESCENT GAS LINE URINAL r FIXTURE W/ EMER. BATTERY PACK. � TEL. SWITCHBOARD �B HOSE 01515 rxx FLUORESCENT O LAVATORY O z FIXTURE CLOCK GO CLEAN OUT BATHTUB 2 - 40W FLUORESCENT SOUND SYSTEM FD FLOOR DRAIN STRIP FIXTURE I -40W ® SHOWER FLUORESCENT -� MICROPHONE STRIP FIXTURE EWH WATER HEATER TELEPHONE PANEL CITY QF S0LJ 1�1-i ,y ,J�`:�I ! � DEFT. ELECTRICAL PANEL BUILDING �''�`-. . wCT10N BUILDING SEC"i ,,.., -. APPROVED BY, DATE: ABBREVIATIONS MECHANICAL A.F.F. ABOVE FINISH FLOOR PART. PARTITION WALL FINISH (CONT'D) A.G. AIR CONDITIONINdl, '1, '40L. PLATE ALUM. ALUMINUM RECPT. RECEPTACLE MTL. METAL BLDG. BUILDING REFL. REFLECTED MA. MARBLE BLK'G. BLOCKING REFRG, REFRIGERATOR CEILING DIFFUSER WALL REGISTER 5". PRA55 REINF, REINFORCE WINDOW TREATMENT RETURN OR SUPPLY )BR. BRONZE SECT. SECTION 1 CLG. CEILING SHT. SHEET PL PLASTIC (7-: CENTERLINE F.5-C. FLORIDA LAMINATE CEILING DIFFUSER, CONC. CONCRETE BUILDING 5 BLINDS W/ BAFFLE CONT. CONTINUOUS CODE VB VERTICAL t THEMOSTAT w DED DEDICATED BLINDS 5'_0� AFF D.F. DRINKING FOUNTAIN STL. STEEL D DRAPERY EF ELEC, ELECTRIC TEL. TELEPHONE 5 SHADES RETURN AIR i © EXHAUST FAN ELEV. ELEVATION TEMP, TEMPERED ACT ACOUSTICAL EX15T'G. EXISTING TYP, TYPICAL CLG. TILE EE F.E. FIRE EXTINGUISHER VERT. VERTICAL E5 EXPOSED F.F. FIN15H FLOOR WSCT. WAINSCOT SPLINE FAN/LIGHT COMBINATION G.C. GENERAL CONTRACTOR WD. WOOD CS CONCEALED LINEAR DIFFUSER GLS. GzLASS SPLINE HOL, HOLLOW FLOORING MP METAL PIN ® FIRE DAMPER HORIZ. HORIZONTAL SP SPRAYED t INT. INTERIOR AT ASHPALT TILE PH PLASTER JT. JOINT VT VINYL TILE HUNG FIRE SPRINKLER LAV. LAVATORY VCT VINYL COMpOS, EC EXISTING LT. LIGHT VCT TILE CEILING: MAX. MAXIMUM G CARPET MIN, MINIMUM CT CERAMIC TILE MTL. METAL QT QUARRY TILE WALL FINISH N,I.G. NOT IN CONTRACT T TILE N.T,S, NOT TO SCALE M MARBLE WC WALLCOVERINCx E O,C. ON CENTER CK CORK TILE P PAINT /STAIN j I OP'G. OPENINra WD WOOD WD WOOD I EX EXISTING MI MIRROR DRAWN I t:. � 1 E.M.M. G:HECKF D r W.H.F. DATE t acAL AS NOTED DRAWN E.M.M. G:HECKF D W.H.F. DATE 2 -16 -10 acAL AS NOTED JOB. ND, 10 -0011 SHEET C3N =: I C1= SHEETS 4 Ili l i