13-122(2)-021i I i I i i GENERAL PLUMBING NOTES 1. i 7, PROVIDE MEANS "FURNISH AND INSTALL". y i 1 3" - 1 8. DO A COMPLETE JOB, EVERYTHING CONNECTED, READY FOR USE. 314"0 CW--1 /2 " 0 HW r ® 314"0 CW/HW NOTE: ALL VTR SHALL BE OFF" SET A MIN. OF 4' -0" FROM FIRE SEPARATION WALL ALL SANITARY PIPE 2 112 "0 OR SMALLER SHALL RUN © 1/4" SLOPE PER L -FT. 3" AND LARGER @ 118" SLOPE PER L.FT. ALL TUB AND SHOWER SHALL BE ANTISCALDING VALVE O 110', (TYPICAL) t GENERAL PLUMBING NOTES 1. ALL WORK SHALL CONFORM WITH ALL LOCAL, STATE, FEDERAL 7, PROVIDE MEANS "FURNISH AND INSTALL". 112 "0 CW,HIN ORDINANCES AND 2010 FLORIDA BUILDING CODES GOVERNING THE 3" 1/2 "0 C INSTALLATION OF THE PLUMBING SYSTEM. IF WORK AS LAID 8. DO A COMPLETE JOB, EVERYTHING CONNECTED, READY FOR USE. 314"0 CW--1 /2 " 0 HW OUT, INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS ® 314"0 CW/HW WITH LOCAL ORDINANCES, BUILDING CODES AND REGULATIONS, 9. SHOP DRAWINGS: CONTRACTOR SHALL FURNISH THE ENGINEER 3/4 "0 CW THE CONTRACTOR SHALL REPORT IN WRITING TO THE WITH SHOP DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE 314 "0 H WS ARCHITECT /ENGINEER BEFORE SUBMITTING A BID. THE FOR APPROVAL. 1"0 CWS -112 "O HWS ARCHITECT /ENGINEER WILL THEN ISSUE INSTRUCTIONS AS ® 1 "0 CWS HOW TO PROCEED. 10. AT COMPLETION OF JOB THE PLUMBING CONTRACTOR SHALL 1"0 CWS -312 "O HWS DISHWASHER GIVE THE OWNER AN AS -BUILT SET OF REPRODUCIBLE SEPIAS 2. THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT SHOWING THE EXACT LOCATION OF ALL INSTALLATIONS. 2" NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE 112" HOSE 8183 MINOR ITEMS. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE 11. PLUMBING CONTRACTOR SHALL PRESSURE TEST ALL PIPING AS - - STRUCTURAL, ARCHITECTURAL AND SITE CONDITIONS SHALL REQUIRED BY CODE. TEST SHALL BE WITNESSED AND APPROVED 1/2" GOVERN THE EXACT LOCATIONS. CONTRACTOR SHALL FOLLOW BY PROPER AUTHORITIES. 2„ DRAWINGS IN LAYING OUT WORK, CHECK DRAWINGS OF ALL 112" REFRIGERATOR TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED 12. THE PLUMBING CONTRACTOR SHALL WARRANT ALL - - AND MAINTAIN MAXIMUM HEAD ROOM, AND SPACE CONDITIONS WORKMANSHIP AND MATERIALS FOR ONE YEAR FROM THE DATE AT ALL POINTS. WHERE HEAD ROOM, OR SPACE CONDITIONS OF FINAL WORK ACCEPTANCE BY OWNER. ANY BREAKDOWN r • APPEAR INADEQUATE, ARCHITECT/ ENGINEER SHALL BE OCCURRING IN FIRST YEAR SHALL BE REPAIRED AT NO EXPENSE • NOTIFIED BEFORE PROCEEDING WITH INSTALLATION. THIS TO THE OWNER. Z CONTRACTOR SHALL, WITHOUT EXTRA CHARGE, MAKE FIELD • OU• MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT 13. PROVIDE BATHROOM FIXTURES AS SPECIFIED. WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION p OF THE WORK . 14. PROVIDE SHUT -OFF VALVE FOR EACH FIXTURE. 3. EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBMITTING A BID. 15. WHEREVER NOT SIMILAR METALS ARE TO BE JOINED, CONTRACTOR WILL BE REQUIRED TO FURNISH, INSTALL AND /OR A DI- ELECTRIC FITTING SHALL BE PROVIDED TO CONNECT BOTH CONNECT WITH APPROPRIATE SERVICES ALL PLUMBING ITEMS TYPES OF PIPES. Q Z SHOWN ON ANY OF THE ARCHITECTURAL, AIR CONDITIONING, - .J It Q ELECTRICAL AND SPRINKLER DRAWINGS WITHOUT ADDITIONAL 16. PLUMBING CONTRACTOR SHALL PROVIDE AIR CONDITIONING O EXPENSE TO THE OWNER. IF DISCREPANCIES , CONFLICTS CONDENSATE DRAIN AND TRAP. SEE AIR CONDITIONING PUNS Uu•o0 INTERFERENCE OR OMISSIONS OCCUR BETWEEN DRAWINGS, FOR LOCATION OF UNITS AND DRAINS. wwo NOTIFY IN WRITING THE ARCHITECT/ ENGINEER IN AMPLE TIME 17. MATERIALS iv TO PERMIT REVISIONS BEFORE THE BIDS ARE SUBMITTED. a z,,� A. COLD WATER PIPING DOWNSTREAM OF WATER METER SHALL BE 4. INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST TYPE "L" COPPER BELOW GROUND AND TYPE "M" COPPER ABOVE CLASS WORKMANLIKE MANNER. THE OWNER RESERVES THE GROUND. • RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ITEMS WHICH, B. COLD WATER PIPES INSIDE OF SLAB SHALL BE TYPE "K" SOFT r IN HIS OPINION, DO NOT PRESENT A NEAT AND WORKMANLIKE COPPER INSTALL INSIDE POLYETHYLENE CONDUIT. NO JOINTS x APPEARANCE. REMOVAL AND REPLACEMENT IS TO BE DONE PERMITTED INSIDE SLAB. • IMMEDIATELY WHEN DIRECTED BY THE OWNER IN WRITING, AT THE SOLE EXPENSE OF CONTRACTOR. C. SANITARY WASTE AND VENT 4 "0 AND SMALLER SHALL BE P.V.C., cl SCHEDULE 40. 5. START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS D. STORM LINES INSIDE BUILDING SHALL BE P.V.C. SCHEDULE 40 ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO OLR­', SUITABILITY OF THE WORK OF OTHER. TRADES OR OTHER E. IN COASTAL AREAS ALL SANITARY AND STORM PIPING OUTSIDE OF CONTRACTORS TO RECEIVE HIS WORK. THIS CONTRACTOR BUILDING SHALL BE SCHEDULE 40, PVC. SHALL REMOVE AND REPLACE, AT HIS EXPENSE, ALL PLUMBING F, CONDENSATE DRAIN PIPE SHALL BE SCHEDULE 40, PVC PIPE SCALE WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF AND FITTINGS. INTERFERENCE WITH OTHER TRADES. DRATVN • WAC. t, JOj NO.: B- 2000 '" >: •, G. WATER HEATER RELIEF AND DRAIN LINE SHALL BE TYPE "L" COPPER, 6. THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE, MIN 314" DIA. P_ FEES, PERMITS , ASSOCIATION DUES, ROYALTIES AND TAXES OF WHATEVER NATURE SHALL APPLY TO THIS WORK. HE SHALL ALSO FIRE RATED PENETARATION NOTE OF PAID ALL THE INSPECTION FEES AS MAY REQUIRED BY LAW OR ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY WHEN FIRE PENETRATION OF PIPING OCCUR, SHALL BE PROTECTED ' DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF LAWS, BY ASSEMBLY No. W -L -2088, UL APPROVED RULES OR ORDINANCES. NOTE: ALL VTR SHALL BE OFF" SET A MIN. OF 4' -0" FROM FIRE SEPARATION WALL ALL SANITARY PIPE 2 112 "0 OR SMALLER SHALL RUN © 1/4" SLOPE PER L -FT. 3" AND LARGER @ 118" SLOPE PER L.FT. ALL TUB AND SHOWER SHALL BE ANTISCALDING VALVE O 110', (TYPICAL) t ITEM WATER PIPING SIZE WATER O 112 "0 CW,HIN WATER CLOSET 3" 1/2 "0 C - - TUB 314"0 CW--1 /2 " 0 HW 112„ ® 314"0 CW/HW 2" 112" 3/4 "0 CW BIDET © 314 "0 H WS 112„ LAVATORY 1"0 CWS -112 "O HWS 112" ® 1 "0 CWS 1 -112" 112" 1"0 CWS -312 "O HWS HAMMER ARRESTOR — AMTROL, MODEL 500 — INSTALL IN ACC. LOCATION. - CONNECTION SIZE: 112" NPT - HEIGHT: 4-112" — DIAMETER: 3 -318 MAX. PRESSURE: 150 PSI MAX. TEMP: 200' F MAX. SHOCK PRESSURE: 200 PSI FIXTURE CONNECTION SCHEDULE ITEM WASTE do SOIL WATER COLD HOT WATER CLOSET 3" 112" - - TUB 2" 112„ 112„ WHIRLPOOL 2" 112" 112" BIDET 1 -1/4„ 112„ 112„ LAVATORY 1 -1 /4 " 112" 1 /2 " KITCHEN SINK 1 -112" 112" 1/2" DISHWASHER 1 " hose - - 112" CLOTHES WASHER 2" 112" 112" HOSE 8183 - - 112" - - FLOOR DRAINS 2" MIN. 1/2" - SHOWER 2„ 112" 112" REFRIGERATOR - - 112" - - NOTE: PROVIDE ANTI SCALD VALVE © EACH SHOWER AND TUB NOTE: ALL TRAOS SHALL BF CONSISTENT W /FIXTURE OUTLET SIZE. MAXIMUM FLOW RATE AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS PLUMBING FIXTURE OR FIXTURE FITTING MAXIMUM FLOW RATE OR QUANTITY LAVATORY, PRIVATE 1.5 GPM O 80 PSI SHOWER HEAD 1.5 GPM * 80 PSI KITCHEN SINK FAUCET 1.5 GPM 9 60 PSI WATER CLOSET 1.28 GALLON PER FLUSHING CYCLE 000 r s r w w PLUMBING PLAN SCALE: 1/4" =1' -0" 'UGr ARC HITECT. °' '�r•W„ • 0• •r••• ••• ORP= LO".Z -RECTO .;. AR0009M ,coo* MIAMI, nORIDA 33155 TEUEPHONE� C3os) 09-=7 OWNER 000 r s r w w u• � r 4 w % ••• u•U • • r •ee. • G • E f & • • •• • 0 • ••Y. w r Ci • 4 • •• t� • Ju 0 LY i u w •. W • +� r • C, r • W Z •w• • OU• •l. • �M,„. p z u) `.r 0 Q Z lY' - .J It Q U) O •••e Uu•o0 •G�• wwo r iv a z,,� x.•r• • u • • • It r w; w s x w • x SAG, ,� •, cl t, try OLR­', DATE JANUARY It 2013 SCALE AS SHOWN' 4 DRATVN • WAC. t, JOj NO.: B- 2000 '" >: •, i P_ 11-11 SHEET NO. OF 4,r i ARC HITECT. °' '�r•W„ �l ORP= LO".Z -RECTO .;. AR0009M SUS SW. 32 STREET MIAMI, nORIDA 33155 TEUEPHONE� C3os) 09-=7 OWNER w w Zr. W O 0 ran V ! W Z W CO 7� �M,„. p z u) `.r 0 Q Z - .J It Q U) O L0 z,,� TF a. REVISIONS' x SAG, ,� •, cl t, try DATE JANUARY It 2013 SCALE AS SHOWN' 4 DRATVN • WAC. t, JOj NO.: B- 2000 '" >: •, i P_ 11-11 SHEET NO. OF