13-122(2)-018i Above Finished i i Equipment •'• •� i Above Finished 'i Equipment •'• •� X95 Floor PLUMBING NOTES PLUMBING AND MECHANICAL PLANS, ARE PART OF THESE PERMIT PLANS ALL PLUMBING FIXTURES EQUIPMENT SHALL COMPLY W/ FLORIDA BUILDING CODE 2,004 FURNISH ALL LABOR, MATERIALS AND EQUIPMENT REQUIRED FOR THE COMPLETION OF THE SOIL, WASTE, VENT, DOMESTIC WATER HEATERS, PLUMBING FIXTURES AND ALL OTHER SYSTEMS AS INDICATED ON THE DWGS. ALL WORK AND MATERIALS SHALL BE IN STRICT ACCORDANCE WITH ALL LOCAL CODES, RULES AND ORDINANCES HAVING JURISDICTION. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR, IN A FIRST -CLASS WORKMANLIKE MANNER AND MAKE THE COMPLETED SYSTEM FULLY OPERATIVE. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROCESS OF CONSTRUCTION. ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBLIC LIABILITY & PROPERTY DAMAGE FOR THE DURATION OF THE WORK. ALL MATERIALS SHALL BE NEW AND SHALL BEAR UNDERWRITERS' AND UNION LABELS WHERE REQUIRED. UNDERGROUND METAL PIPING SHALL BE PROTECTED WITH A COAT OF BITUMINOUS COMPOUND BEFORE COVERING. "BITUMASTIC" OR EQUAL. ALL UNDERGROUND SOIL AND WASTE PIPING SHALL BE SCHEDULE 40 P.V.C. OR SERVICE WEIGHT CAST IRON WITH MEDIUM WEIGHTS CAST IRON FITTINGS. ALL JOINTS BELOW SLAB TO BE MADE WITH OAKUM AND PURE VIRGIN LEAD. SOIL, WASTE AND VENT PIPING ABOVE SLAB TO BE SAME AS SPECIFIED FOR BELOW SLAB EXCEPT THAT THE CONTRACTOR MAY AT HIS OPTION USE NO- HUM PIPE AND FITTINGS IF ACCEPTABLE BY LOCAL AUTHORITIES. ALL PIPING SHALL BE SUPPORTED IN APPROVED MANNER FROM BUILDING STRUCTURE. HANGERS FOR COPPER PIPING SHALL BE COPPER OR COPPER PLATED. ALL HOSE BIBS SHALL BE FURNISHED W/ BACK FLOW PREVENTERS AND BE MOUNTED 26" ABOVE GRADE. CONDENSATE DRAIN PIPES SHALL BE A MINIMUM OF 3/4" PVC (SCHEDULE 40) WITH TRAPS, INSULATED WITH 1/2" AMAFLEX, AND TERMINATED 6 ABOVE GRADE OUTSIDE OF THE BUILDING. FURNISH AND INSTALL PRESSURE RELIEF VALVE LINE AND TERMINATE AT A LOCATION TO PROVIDE READY, VISUAL INDICATION FLOW. THE HOT WATER LINE SHALL BE FULLY INSULATED WITH 1 INCH AMAFLEX, THROUGH AND BELOW SLAB. COPPER WATER LINES RUNNING UNDER SLAB SHALL BE PROTECTED BY A MIN. 12 INCHES OF EARTH COVER, 1 INCH AMAFLEX (HOT WATER ONLY) AND SLEEVED 12 INCH BELOW SLAB TO 12 INCHES ABOVE SLAB. SHOWER HEAD WATER FLOW MUST BE RESTRICTED TO NO MORE THAN 2.5 GALLONS PER MINUTE. TEST ALL WATER PIPING UNDER A 150# HYDROSTATIC TEST FOR A MINIMUM PERIOD OF 2 HOURS, VERIFY ALL DIMENSIONS WITH STRUCTURE PRIOR TO ANY FABRICATION OR INSTALLATION. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF FIXTURES, PIPING, EQUIPMENT, ETC. PLUMBING CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS & DIMENSIONS AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT. EXTEND SERVICE TO WATER METER. PROVIDE WATER METER AND SHUTOFF VALVE IN VALVE BOX OUTSIDE BLDG. CONSULT ARCHITECT FOR LOCATION. LOCATIONS WHERE PIPES PENETRATE WALLS, FLOORS, AND CEILINGS SHALL BE WATERTIGHT. SANITARY PIPES SHALL BE OF HUBLESS CAST IRON OR PVC (SCHEDULE 40) AS APPROVED BY BUILDING OFFICIAL. CONTRACTOR TO VERIFY AT SITE LOCATION, ALL EXISTING CONDITIONS, ELEVATIONS AND SIZE OF EXISTING MAINS, WATER AND SEWER FOR CONNECTION OF NEW SERVICES BEFORE INSTALLATION OF ANY PIPING. PROTECT ALL FIXTURES AGAINST WATER HAMMER W/ APPROVED AIR CHAMBERS OR SHOCK ABSORBERS. PROVIDE CONTROL VALVES TO ALL MAINS ENTERING THE BUILDING, RISERS, BRANCHES, GROUP OF FIXTURES, AND TO EACH PIECE OF EQUIPMENT. PROVIDE FULLY ACCESSIBLE CLEANOUTS ON SANITARY AND ANY WASTE PIPING AT EVERY CHANGE OF DIRECTION, AND AT BOTTOM OF STACKS. CLEANbUTS LOCATION AND SIZES ON HORIZONTAL LINES SHALL BE ACCORDING TO CODE. VENT LINES TO EXTEND 6" MINIMUM ABOVE ROOF AND FLASH WITH LEAD. PROVIDE AIR CHAMBERS AND SHUT OFF VALVES FOR ALL WATER SUPPLY PIPING AT FIXTURES. PROVIDE VACUUM BREAKER AND SHUT OFF VALVE ON ALL HOSE BIBS. SANITARY PLUMBING PIPING TO HAVE MIN. 1 8" PER FT. PITCH AT ALL HORIZ. RUNS PROVIDE CLEANOUTS AT THE BASE OF WASTE STACKS. ALL TUBS AND SHOWERS TO BE PROVIDED WITH ANTI -SCALD SHOWER VALVES. ANCHORAGE METAL AND WIRE LATH: PNEUMATICALLY FAST NED W� "PNEU- FAST" 16 GA. STAPLE SPEC. #101 -1, TYPE 1 OR BETTER HOT DI PED) SATIN FIN. GALVANIZED COATING, HAVING A TENSILE STRENGTH 0 130M PSI. FASTENERS SHALE BE MIN. 1 1,/2" LONG, SPACED AT 6" O.C. MAX. & SIDE LAPS SHALL BE SECURED & 9' O.C. MAX. EDGY CAL- NOTES THE DWGS. ARE DIAGRAMMATIC & INDICATE THE GENERAL ARRANGEMENT OF THE ELECTRICAL WORK. ANY DISCREPANCIES ON THE DOCUMENTS SHALL BE CALLED TO THE ARCHITECT'S ATTENTION PRIOR TO THE COMMENCEMENT OF WORK. DO NOT SCALE FLECTRICAL DRAWINGS, ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELEC. CODE & ALL CODES, REGULATIONS & RESTRICTIONS HAVING JURISDICTIONS. AS PER FLORIDA BUILDING CODE CONTRACTOR SHALL VERIFY WITH LOCAL ELECTRICAL UTILITY COMPANY THE SHALL LOCATE METER AND PANEL AS REQUIRED. CONTRACTOR SHALL VERIFY ALL CONDUCTORS & BREAKERS W/ EQUIP. MFG. SPECIFICATIONS. ELECTRICAL SYSTEM SHALL BE GROUNDED. PROVIDE PROPER SIZE & TYPE OF PROTECTION DEVICES TO MATCH EQUIPMENT BEING SERVED. LOAD DATA IS BASED ON INFORMATION GIVEN TO ARCHITECT /ENGINEER AT TIME OF DESIGN, VERIFY ALL EQUIP. & PANEL SIZES PRIOR TO ORDERING. ALL MATERIALS SHALL BE NEW AND BEAR U.L. LABELS, WHERE APPLICABLE. ALL WORK SHALL BE DONE BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE AND ACCEPTABLE TO THE ENGINEER /ARCHITECT. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH PROGRESS OF CONSTRUCTION. CONTRACTOR SHALL PROVIDE REQ'D, INSURANCE FOR THE PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. CIRCUITS SHOWN ON PLANS ARE TO DETERMINE LOAD DATA AND PANEL SIZES. THE CONTRACTOR SHALL PROVIDE CIRCUITS AND REQUIRED ROUTING OF CONDUITS TO SUIT JOB CONDITIONS AND BALANCE LOADS. FURNISH AND INSTALL FIXTURES AS CALLED FOR ON PLANS OR AS SELECTED BY OWNER. THE ELECTRICAL CONTRACTOR SHALL COORDINATE THE EXACT LOCATION OF ALL H.V.A.C. EQUIPMENT AND THEIR GIVEN LOAD WITH THE MECHANICAL CONTRACTOR BEFORE ROUGHING -IN FOR PROPER POWER AND WIRING CONTROL LAYOUT & INSTALLATION. DISCREPANCIES BETWEEN THE GIVEN & ACTUAL H.V.A.C. LOADS SHALL BE CORRECTED BEFORE ROUGHING IN. GROUND -FAULT CIRCUIT PROTECTION; ALL 120V SINGLE PHASE, 15 & 20 AMP OUTLETS INSTALLED OUTDOORS, IN BATHROOMS, & GARAGES SHALL HAVE GFI CIRCUIT BREAKERS OR RECEPTACLES. ALL BREAKERS SHALL HAVE 10,000 A.I.C. MINIMUM, U.O.N. INSTALL FACILITIES FOR TEMPORARY CONSTRUCTION POWER AS REQUIRED. ELECTRICAL CONTRACTOR SHALL NOTIFY ENGINEER /ARCHITECT IN WRITING OF ANY CONFLICT AND /OR DISCREPANCIES FOUND WITH WORK AS SHOWN, SPECIFIED OR IMPLIED ON THESE PLANS, PRIOR TO PROCEEDING W/ WORK. CONTRACTOR SHALL VERIFY EXACT LOCATIONS OF FIXTURES AND OUTLETS AT JOB SITE BEFORE ROUGHING. CONTRACTOR MAY SELECT DIFFERENT MANUFACTURER OR FIXTURES WITH EQUAL SPECIFICATIONS. SMOKE DETECTORS SHALL BE HARD WIRED (110 VOLT TYPE) TO NON- SWITCHABLE KITCHEN OR BATHROOM LIGHTING CIRCUIT AND SHALL NOT BE CONNECTED TO THE LOAD SIDE OF A GROUND FAULT CIRCUIT INTERRUPTER. SMOKE DETECTORS SHALL BE PROVIDED W/ VISIBLE "POWER ON INDICATOR" AND A TEST BUTTON WITH BATTERY BACKUP SYSTEM. MULTIPLE DETECTORS MUST BE INTERCONNECTED. COORDINATE RACEWAY INSTALLATION W/ OTHER TRADES. ALL ELECTRICAL SWITCHES SHALL BE 48" A.F.F. UNLESS OTHERWISE NOTED. ALL WALL RECEPTACLES SHALL BE 12" A.F.F. UNLESS OTHERWISE NOTED. SECURITY NOTES ALL LOCKS ON EXTERIOR DOORS SHALL RESIST A FORCE OF 300 # APPLIED IN ANY MOVABLE DIRECTION. ALL EXTERIOR LOCKS SHALL BE SINGLE CYLINDER W/ 1 THROW FOR 1 3/4" SOLID CORE DOOR. ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A KEY OPERATED LOCK OPERABLE FROM EXTERIOR WITH A MINIMUM 6000 POSSIBLE KEY CHANGCS. KEY ON KNOB LOCKS SHALL HAVE AN AUXILIARY DEAD BOLT W/ HARDENED BOLT OR WITH INSERT. EXT. SWING DOORS SHALL BE SOLID CORE NOT LESS THAN 1 3/4" THICK. FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED W/ A VISION SCOPE OR VISION PANEL. HINGES ON OUT SWINGING EXTERIOR DOORS SHALL HAVE NON—EXPOSED SCREWS AND NON — REMOVABLE PINS. SINGLE SWING EXTERIOR DOORS CONNECTING LIVING AREAS WITH GARAGE AREAS SHALL BE SOLID CORE 104" THICK AND SHALL BE SECURED WITH A LATCH AND SINGLE BOLT W1 ONNE INCH MIN. THROW OR A COMBINATION OF DEAD BOLT AND DEAD LATTCH SETS AND AN AUTOMATIC DOOR CLOSER. ALL GLASS IN EXTERIOR DOORS SHALL COMPLY WITH ANSI 279.1 ALL WINDOWS (OPERABLE) SHALL WITHSTAND A FORCE OF 150# IN ANY OPERABLE DIRECTION. SLIDING GLASS DOORS & WINDOWS SHALL BE INSTALLED & CONSTRUCTED SO THAT NO PANEL CAN BE LIFTED FROM THE TRACKS POSITION & SHALL COMPLY W/ THE A.A.M.A 1303 -3 STANDARDS FOR FORCED ENTRY RESISTANCE. SLIDING GLASS DOORS SHALL HAVE DEAD BOLT OR PIN SYSTEM NOT REMOVABLE FROM THE OUTSIDE AT THE JAMB AND SILL. INTERIOR DOORS TO HAVE A CYLINDRICAL TYPE LOCK SETS W/ PRIVACY LOCK BY INSIDE PUSH BUTTON WHICH AUTOMATICALLY OPENS BY TURN OR CLOSING ACCORDING TO FED. SPEC. #160 AND 1511. OVERHEAD DOORS SHALL BE PROVIDED WITH MULTIPLE POINT LOCKS OR BE LOCKED AT MORE THAN ONE POINT WITH HARDENED BOLTS WITH INSERTS ENGAGING AT LEAST TWO OPPOSITE POINTS A MIN. OF 5/8 ". GENERAL_ NOTES ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL CODES, RULES, REGULATIONS AND RESTRICTIONS HAVING JURISDICTION ON THIS PROJECT. AS PER LATEST EDITION OF FLORIDA BUILDING CODE. WORK SHALL INCLUDE ALL ITEMS (BUILDING AND SITE) INDICATED ON THESE DRAWINGS UNLESS OTHERWISE NO ED. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. THE ARCHITECT SHALL BE NOTIFIED OF ANY DEVIATION FROM THE PLANS PRIOR TO CONSTRUCTION. DRAWINGS SHALL NOT BE SCALED; WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. SHOP DRAWINGS SHALL FOR WINDOWS,DOORS,WOOD TRUSSES,STAIRS & RAILINGS BE SUBMITTED TO THE ARCHITECT FOR GENERAL REVIEW AND DESIGN COMPLIANCE. CONTRACTOR SHALL MAINTAIN TEMPORARY ELECTRICAL, WATER AND SANITARY FACILITIES FOR THE DURATION OF CONSTRUCTION. CONTRACTOR SHALE REMOVE ALL CONSTRUCTION DEBRIS FROM THE JOB SITE ON A REGULAR BASIS AND LEAVE THE BUILDING BROOM CLEAN. THE CONTRACTOR SHALL ACQUAINT HIMSELF WITH THE SITE PRIOR TO CONSTRUCTION AND SHALL VERIFY ALL FIELD CONDITIONS PRIOR TO ACTUAL CONSTRUCTION. ANY DEVIATION FROM THE CONSTRUCTION DOCUMENTS DISCOVERED AT THIS TIME SHALL BE REPORTED BY THE CONTRACTOR IMMEDIATELY TO THE ARCHITECT. ALL WORKMANSHIP SHALL BE NEAT, CLEAN, TRUE AND CORRECT. ALL GLASS WITHIN 12" OF ANY DOOR, FIXED GLASS, SLIDING GLASS DOORS AND ALL GLAZING AT TUB AND SHOWER ENCLOSURES SHALL BE TEMPERED SAFETY GLASS. OMISSIONS FROM THE DRAWINGS OR SPECS. OR THE MISDESCRIPTION OF DETAILS OF WORK, WHICH ARE MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS & SPECS., OR WHICH ARE CUSTOMARILY PERFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MISDESCRIBED DETAILS OF WORK, BUT THEY SHALL BE PERFORMED AS IF FULLY AND CORRECTLY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. ALL WOOD AND /OR STEEL COLUMNS SHALL BE 1 HOUR FIRE RATED , WOOD FURRING IN CONTACT WITH MASONRY MUST BE PRESSURE TREATED 2004 F.B.C. DOOM i , DO CLOSET & BATHROOM DOORS SHALL COMPLY W/ SECTIONS 24 -2.4.3 AND 24 -2.4.4 NFPA NFPA 24 -2.4.3 EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM INSIDE THE CLOSET. NFPA 24 -2.4.4 EVERY BATHROOM DOOR LOCK SHALL BE DESIGNED TO PERMIT THE OPENING OF THE LOCKED DOOR FROM THE OUTSIDE IN AN EMERGENCY. BUILDING IDENTIFICATION REQUIRED APPROVED NUMBERS OR ADDRESSES BE PLACED ON ALL NEW AND EXISTING BUILDINGS IN SUCH POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. SAID NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND EACH BUILDING, OR PORTION OF BUILDING, HAVING AN ADDRESS NUMBER, THE OWNER OR PERSON IN CHARGE OF THE BUILDING, OR OF EACH PORTION, SHALL CAUSE SUCH ADDRESS NUMBER TO BE DISPLAYED AT ALL TIMES, IN NUMERALS ON OR ADJACENT TO THE BUILDING OR PORTION SO THAT THE NUMERALS ARE READABLE FROM THE STREET 6R THOROUGHFARE TO WHICH THE NUMBER APPLIES. NUMERALS SHALL BE AT LEAST SIX INCHES IN HEIGHT FOR MULTIFAMILY RESIDENTIAL BUILDINGS..." EIRE G.C. SHALL INSTALL PORTABLE FIRE EXTINGUISHERS DURING THE TIME OF CONSTRUCTION IN COMPLIANCE OF THE FLORIDA FIRE PREVENTION CODE NFPA 1, 2001 EDITION SECTIONS 29 -2.7, 29 -2.8, 29 -2.9 AND 3 -9.6. IF COMBUSTIBLE LIQUIDS WILL BE STORED, HANDLED OR USED ON THE CONSTRUCTION SITE THE G.C. SHALL COMPLY WITH THE FLORIDA FIRE PREVENTION CODE NFPA 1, 2001 EDITION SECTIONS 29- 2.15.1, 29 2.15.2, 29- 2.15.3, 29 2.15.4 AND 29-- 2.15.5. COMPLY WITH FLORIDA FIRE PREVENTION CODE N.F.P.A. 1 29-2.2 2001 EDITION MEMEMA NON-BEARING INTERIOR PARTITIONS ALL INTERIOR NON BEARING PARTITIONS SHALL BE 3 5/8" METAL STUDS GA AT 24" O.C, MAX. SPACING W/ 1/2" MIN. GYPSUM DRYWALL EACH SIDE. A.F.F. Above Finished EQUIP. Equipment •'• •� X95 Floor EXIST. Existing :� ACOUSTIC. Acoustical EXT, •. Exterior ALUM. Aluminum FBD. Fiber Board ANOD. Anodized FBO. Furnished by Oth*rs• Y• BD. Board FD. Floor Drain B.O.B. Bottom of Beam FE. Fire Extinguisher CAB. Cabinet FF &E. Furniture, Fixtures CLG. Ceiling Wr �M❑ & Equipment CLOS. Closet FIN. Finish CLR. Clear FLR. Floor CMU. Concrete Masonry FRP. Fiberglass Reinforced Unit Plastic CNTR. Counter FSE. Food Service Equip. COL. Column F.V. Field Verify CONC. Concrete GA. Gage CONN. Connection GALV. Galvanized CONT. Continuous GC. General Contractor CT, Ceramic Tile GL Glass DBL. Double GYP.BD. Gypsum Board DN. Down INT. Interior DR. Door HC. Handicap Accessible DTL. Detail H. M. Hollow Metal DWG. Drawing HT. Height DWR. Drawer JST. Joist EA. Each LAM. Laminated EL Elevation LAV. Lavatory ELEC. Electrical MANUF. Manufactured ELEV. Elevation EQ. Equal MAX. Maximum RECEPT.. Receptacle MECH. Mechanical REINS. Reinforced MIN, Minimum REQ'D. Required MISC. Miscellaneous RM. Room MLD. Molding R.O. Rough Opening M.O. Masonry Opening R.O.J. Received on Job M.T. Metal Threshold S.C. Solid Core MTD. Mounted S/S Stainless Steel MTL Metal SCHED. Schedule MUL. Mullion SIM. Similar NIC. Not in Contract STD. Standard NTS. Not to Scale STL. Steel O.C. On Center STRUCT. Structural OD. Outside Diameter SUSP. Suspended OPNG. Opening TEMP. Tempered OPT. Optional TYP. Typical PBD. Particle Board VCT. Vinyl Composition PE. Plate Tile PLAM. Plastic Laminate VERT. Vertical PLYWD. Plywood VWC. Vinyl Wall Covering PAL Panel W/ With P.O.S. Point of Sale W/0 Without PR. Pair W.C. Water Closet PREP. Preparation WD. Wood PTD. Painted W.H. Water Heater QT. Quarry Tile WIN. Window RA. Return Air WSCT. Wainscot RAID, Radius WT. Weight RE. Reference WWF. Welded Wire Fabric I I ABBREVIATIONS BATHROOMS PLUMBING FIXTURES SHALL BE INSTALLED AND SPACED IN A MANNER TO PERMIT EASY ACCESS FOR CLEANING AND FOR THE INTENDED USE, AND SHALL BE SET WITH THE MINIMUM CLEARANCES AS SETH FORTH IN F.B.C. 2004 PLUMBING CODE . ALL MIRRORS EXCEEDING 9 SQUARE FEET INSTALLED IN VERTICAL WALLS SHALL BE SUPPORTED ON THE BOTTOM AND SHALL BE SECURELY AFFIXED TO THE WALL IN ACCORDANCE WITH THE MFR. SPECS. TOILET ROOMS SHALL COMPLY WITH F.B.C. 2004 ED. FLOORS SHALL BE OF IMPERVIOUS MATERIAL AS PER F.B.C. 2004 PLUMBING CODE . ALL WATER CLOSETS, LAVATORIES, SHOWERHEADS, AND SINKS SHALL COMPLY WITH PLUMBING CODE OF THE F.B.0 2004 EDITION Y 0F a�`U'i rye r'4,ii�N. uv,.,.S1 ?i¢ It s 1. of South �'A%ami C�ty guild�ng Dept. e 0130 Sunset 33183 South 0JLMt9 ft, 3 YY• • Y ••4 V YV yY � V {Y V V V W U 4 V Y•G OLR ARCHITICT ORES TES LOPEZ -RECTO ARM350 X95 S.W. 32 STREET MIAMI, FLORIDA 33155 TELEMONE: G" Co W7 OWNER? w 0 Z W F_ CD Z W WM J < Wr �M❑ Z 2 =o W F- J �0 v, �� Z O � ° H C C (30 0 Z REVISIONS: SEAL: DATE : JANUARY It 2013 SCALD : AS SHOWN DRAWN : W.A.C. JOB NO.: 13-= D-4 SHEET NO.: OF