Loading...
13-122(2)-005DEMOLITION WALL LEGEND. EXISTING BUILDING ELEMENTS TO REMAIN. EXISTING BUILDING ELEMENTS TO BE REMOVED. SCOPE OF WORK INTERIOR DEMOLITION OF AREAS SHOWN IN PLAN, REMOVAL OF ALL EXISTING ELECTRICAL OUTLETS, SWITCHES AND LIGHT FIXTURES IN THE PATH OF CONSTRUCTION, ELECTRICAL CONTRACTOR TO PULL WIRES TO POINT OF ORIGIN. ELECTRICAL CONTRACTOR TO PULL PERMIT. REMOVAL OF EXISTING WINDOWS, DOORS, INTERIOR PARTITIONS AS PER PLAN, PORTION OF EXISTING CBS WALLS AND FINISHES. INSTALL NEW WINDOWS, DOORS, ELECTRICAL, MECHANICAL AND PLUMBING AS PER PLANS. WORKS EXCEED 50% OF EXISTING, DEMOLITION NOTES: 1. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS PRIOR TO COMMENCING WORK. 2. G.C. IS RESPONSIBLE FOR THE STORAGE AND DISPOSAL OF DEBRIS CAUSED BY ANY DEMOLITION REQUIRED BY THIS JOB. 3. G.C. IS RESPONSIBLE FOR PROVIDING BARRICADES TO STOP ANY PEDESTRIAN TRAFFIC AT THE AREA FOR CONSTRUCTION. 4. IN THE EVENT THAT ANY DISCREPANCIES ARE FOUND DURING THE DEMOLITION STAGE, THE G.C. IS RESPONSIBLE FOR NOTIFYING THE ARCHITECT PRIOR TO PROCEEDING WITH THE WORK. 5. ALL ELECTRICAL OUTLETS, FIXTURES AND EQUIPMENT THAT IS REMOVED SHALL HAVE ALL WIRES PULL BACK ALL THE WAY TO THE POINT OF ORIGIN. 6. ALL ABANDONED PLUMBING PIPES BELOW SLAB AND INSIDE WALLS SHALL BE CAPPED OFF. 7. G.C. IS RESPONSIBLE FOR NOTIFYING THE ARCHITECT OF ANY GAS LINES, OR FUEL STORAGE TANKS FOUND IN THE PATH OF CONSTRUCTION PRIOR TO REMOVAL. 8. G.C. SHALL KEEP THE JOB SITE CLEAN AND CLEAR OF ANY DEBRIS THAT MAY OCCUR DUE TO THE SCOPE OF WORK. 9. G.C. IS RESPONSIBLE FOR PATCHING UP ANY AREAS DAMAGED DUE TO THE DEMOLITION OR CONSTRUCTION OF THIS PROJECT. 10. ALL INTERIOR WALLS AND PORTION OF WALLS BEING REMOVED ARE NON LOAD BEARING WALLS. DEMOLITION LEGEND: 1. REMOVE EXISTING C.U. AND REFRIGERATION LINES, PULL ELECTRICAL TO POINT OF ORIGIN 2. REMOVE EXISTING A.H.U. AND REFRIGERATION LINES. PULL ELECTRICAL TO POINT OF ORIGIN 3. EXISTING ROOF ABOVE TO REMAIN. 4. REMOVE EXISTING G.W.B ON EXTERIOR WALL. REMOVE EXISTING DAMAGED FURRING STRIPS AND INSULATION. 5. REMOVE EXISTING O.H. AS SHOWN. 6. REMOVE EXISTING ELECTRICAL OUTLETS ON REMOVED WALL. PULL WIRES TO POINT OF SERVICE, 7. REMOVE EXISTING G.W.B. WALLS AS SHOWN. REMOVE ALL ELECTRICAL OUTLETS, AND SWITCHES IN THE PATH OF CONSTRUCTION; PULL WIRES TO POINT OF ORIGIN. 8. REMOVE EXISTING DOOR AND FRAME. 9. REMOVE EXISTING BATHROOM FINISHES IN FLOOR AND WALLS. 10. REMOVE EXISTING BATHROOM FIXTURES. CAP -OFF EXISTING PLUMBING (WATER AND SEWER) BELOW SLAB /INSIDE WALL AND ABANDON; REMOVE ALL ELECTRICAL OUTLETS, AND SWITCHES IN THE PATH OF CONSTRUCTION; PULL WIRES TO POINT OF ORIGIN. 11. REMOVE EXISTING WINDOWS AS PER PLAN. 12. REMOVE EXISTING CBS WALL AND CONCRETE BEAM ABOVE. GC TO PROVIDE TEMPORARY SHORING FOR EXISTING ROOF, EXISTING CONDITIONS / DEMOLITION FLOOR PLAN SCALE: 1/4" =1' -0" sooth ARCHITECT ORBS LOrrz —RECTO AR000M A" M 32 STRM MIAMI, FLORIDA 33155 TELEPHONE; M 6094W OWNER- W U Z W ❑ H C� W Z Lu(y) � J w ❑ < M Z 2 =a W I- Cy) 0 z LL Z O OQ u� D Q ❑ Z Q CY_ REVISIONS; Ste; DATE JANUARY It 2013 SCALE AS SHOWN DRAWN WAC. JO= NO. 13 -7000 A -1 SHEET NO.e OF