Loading...
R13-122-007EXHAUST ROOF CAP DETAIL n.t.s. (typical) roof tile , de w/p cap low profile -for dryer equipped with backdraft damper (not bird screen) -for bathroom provide bird screen I)IK'g 04" sheet metal duct gauge 26 from fan. UNIT MUST BE INSTALLED TO WITHSTAND 150 MPH HURRICANE FORCE WINDS & PROVIDE 1"X118" STRAP TIE -DOWN TO UNIT \v/ SUCTION LINE W/ 112 ARMAFLEX INSULATION & VAPOR BARRIER NOTE: UNITS SHALL BE CLEAR BY 3" MIN. FROM DRIP LINE. CU MOUNTING DETAIL PROVIDE A MIN, OF 4" SPACE WHERE MECHANICAL - COMPONENTS TO ASSURE ADECUATE ACCESS FOR CONSTRUCTION & CLEANING. COIL/HEAT FAN SECTION SECTION FILTER ACCESS N. T. S. ~OAHU SHALL BE MECHANICALLY ATTACHED TO THE SUPPLY AiR PLENUM DUCT ;EILING WALLS i— REF. LINES PROVIDE CAP OFF WITH 114" PERFORATED FOR VENT �12 ' MIN. DRAIN PAN W /WET DETECTOR TO CONTROL OVERFLOW BY SHUTTING DOWN THE UNIT WHEN ACTIVATED. PREFAB MTL. FRAME F. F. A/C CLOSET INSTALLATION N. T. S. GENERAL H. V.A.C. NOTES 1. The contractor shall furnish all labor, material and equipment for a complete H.V.A.C. system in accordance with these drawings. The Florida Building Code 2004 and the latest edition of the following publications: ((a ANS B9.1 Mechanical Refrigeration (b) NFPA Pamphlets 90A & 91 c) SMACNA (d) ASHRAE 2. All air conditioning ductwork shall be 1 112 " standard duty foil reinforced fiberglass (R -6) manufactured logo printed on the vapor barrier. 3. All exhaust ductwork shall be code gage galvanized sheet metal. 4. Duct size shown are net free area inside. 5. All air devices (diffusers, registers and grilles) shall be all aluminum construction, with exposed surface chemically treated to receive paint to match color or AIRGUIDE or approved equal. 6- Provide opposed blade dampers at all diffusers and registers. 7. Thermostats shall be combination cooling /heating with system Cool /Auto /Heat /Off and Fan On /Auto selector switches. 8. Refrigerant pipingg shall be copper type "L" with 3/4" ormoflex. Insulation shall be provided for suction lines. 9. Provide new filters for fan coil before starting. These filters must also be replaced prior to final acceptance by owner. LEG EN D FASTENED INSIDE C.U. TO SLAB W/ 4 -114 "0 x 1 -112" DUCT TO MATCH NECK SIZE TYP. POWDERED ACTUATED PINS AS PER MANUFACTURER MAINTAIN 1' -0" CLEAR FROM SPEC'S RETURN AIR GRILL roft WALL Q) THERMOSTAT 30" Less than 29" wide aft L�J EXHAUST FAN CONDENSING OUTSIDE AIR INTAKE S.R. SIDE REGISTER UNIT CEILING DIFFUSER CCs POWER & CONTROL N.P. HEAT PUMP UNIT J.C.N. LOCATION Rru o ° M'INo„ AIR HANDLER UNIT 4" THVNE CRETE BASE CONDENSING UNIT EF EXHAUST FAN CFM CUBIC FEET PER MINUTE � LIQUID LINE W/ 0 I NSULA TION UNIT MUST BE INSTALLED TO WITHSTAND 150 MPH HURRICANE FORCE WINDS & PROVIDE 1"X118" STRAP TIE -DOWN TO UNIT \v/ SUCTION LINE W/ 112 ARMAFLEX INSULATION & VAPOR BARRIER NOTE: UNITS SHALL BE CLEAR BY 3" MIN. FROM DRIP LINE. CU MOUNTING DETAIL PROVIDE A MIN, OF 4" SPACE WHERE MECHANICAL - COMPONENTS TO ASSURE ADECUATE ACCESS FOR CONSTRUCTION & CLEANING. COIL/HEAT FAN SECTION SECTION FILTER ACCESS N. T. S. ~OAHU SHALL BE MECHANICALLY ATTACHED TO THE SUPPLY AiR PLENUM DUCT ;EILING WALLS i— REF. LINES PROVIDE CAP OFF WITH 114" PERFORATED FOR VENT �12 ' MIN. DRAIN PAN W /WET DETECTOR TO CONTROL OVERFLOW BY SHUTTING DOWN THE UNIT WHEN ACTIVATED. PREFAB MTL. FRAME F. F. A/C CLOSET INSTALLATION N. T. S. GENERAL H. V.A.C. NOTES 1. The contractor shall furnish all labor, material and equipment for a complete H.V.A.C. system in accordance with these drawings. The Florida Building Code 2004 and the latest edition of the following publications: ((a ANS B9.1 Mechanical Refrigeration (b) NFPA Pamphlets 90A & 91 c) SMACNA (d) ASHRAE 2. All air conditioning ductwork shall be 1 112 " standard duty foil reinforced fiberglass (R -6) manufactured logo printed on the vapor barrier. 3. All exhaust ductwork shall be code gage galvanized sheet metal. 4. Duct size shown are net free area inside. 5. All air devices (diffusers, registers and grilles) shall be all aluminum construction, with exposed surface chemically treated to receive paint to match color or AIRGUIDE or approved equal. 6- Provide opposed blade dampers at all diffusers and registers. 7. Thermostats shall be combination cooling /heating with system Cool /Auto /Heat /Off and Fan On /Auto selector switches. 8. Refrigerant pipingg shall be copper type "L" with 3/4" ormoflex. Insulation shall be provided for suction lines. 9. Provide new filters for fan coil before starting. These filters must also be replaced prior to final acceptance by owner. LEG EN D Maximum Hanger spacing 24X24 CD -(SEE SCHEDULE) AIR FLOW DIRECTION ( ARROWS DENOTE DUCT TO MATCH NECK SIZE TYP. 1 WAY, 2 WAY, ETC., SEE PLANS CEILING GRILLE SEE SIZE SCHEDULE RETURN OR EXHAUST, SEE PLANS. DUCT TO MATCH NECK SIZE TYP. 6" RETURN AIR GRILL roft VOLUME DAMPER Q) THERMOSTAT DD DUCT MOUNTED SMOKE DETECTOR SEE F.A. RISER FOR SPECS. SCOPE OF WORK: INSTALL NEW CU AND AHU AS SHOWN. EXISTING DUCTWORK OF EXISTING HOME TO REMAIN. NEW DUCTWORK AS SHOWN ONLY. STANDARD 3" WIDE NANGER6 Hanget extension to be the sum OF the distances between the hanging wires and the duct size, ID (Smacna) Duct size, Inches Maximum Hanger spacing 40: Wide or grater AIR FLOW DIRECTION ( ARROWS DENOTE �- 1 WAY, 2 WAY, ETC., SEE PLANS ��� RETURN OR EXHAUST, SEE PLANS. deep 6" Width between 28" roft 4 4a' and greater WALL MOUNTED SIDE REGISTER. than 16" deep 30" Less than 29" wide aft L�J EXHAUST FAN OA.l. OUTSIDE AIR INTAKE S.R. SIDE REGISTER CD CEILING DIFFUSER CCs CEILING GRILL N.P. HEAT PUMP UNIT J.C.N. UNLESS OTHERWISE NOTED. Rru ROOF TOP UNIT ANU AIR HANDLER UNIT CU CONDENSING UNIT EF EXHAUST FAN CFM CUBIC FEET PER MINUTE SCOPE OF WORK: INSTALL NEW CU AND AHU AS SHOWN. EXISTING DUCTWORK OF EXISTING HOME TO REMAIN. NEW DUCTWORK AS SHOWN ONLY. STANDARD 3" WIDE NANGER6 Hanget extension to be the sum OF the distances between the hanging wires and the duct size, ID (Smacna) Duct size, Inches Maximum Hanger spacing 40: Wide or grater 4 ft Less tha 4a" wide Eft and less than 48" Cxauge deep 6" Width between 28" roft 4 4a' and greater 22 than 16" deep 30" Less than 29" wide aft and 16" depth or less 5UG. CHANNEL SECTION If Total Minimum Minimum Extension is Channel Channel not greater than- Cxauge Profile 6" 24 3" X 1.5" Ia" 22 3" X 2" 30" la 3" X 2" USE OF 2" WIPE 22 gauge 2'x 15" hangers may be substituted For 3" hangers for ducts with widths not over 40" and depths not over 24" provided that not more than one joint occurs between hangers and the maximum hanger spacing Oft. Exception: When duct perimeter is 80" or less and does not require reinforcement two joints are permitted between hangers EX HAU STAN SPECS EF -1 SHALL BE "NUTONE" MODEL #696 50 CFM AIR DELIVERY ©114" SP, 115 VOLTS, 60 Hz, 0.9 AMP. CEILING MOUNTED W/B.D.D. BUILT —IN. HVAC DESIGN REQUIRE: YES NO DUCT SMOKE DETECTOR ALL AIR HANDLERS W /FLOAT SWITCHES MODEL SS1 X FIRE DAMPER(S) REF. UNIT X SMOKE DAMPERS 5EN51BL X FIRE RATE ENCLOSURE VOLTS X FIRE RATED ROOF /FLOOR CEILING ASSEMBLY gt4 X FIRE STOPPING 5UG. X SMOKE CONTROL 1600 X DUCTWORK FLEXIBLE R- FACTOR 6.0 ALL AIR HANDLERS W /FLOAT SWITCHES MODEL SS1 AREA OF GONSTRUGTION NEW CU -I F------- - - - --I EXISTING NEW NEW �AMIEY �MASTER BEDROOMI a NEW I I � � CG 10X 10 1W BATH 200 CFM NEW REF. LINES (OH) 0 C60 BCFM 1 W L�J - - - -- -.--- J L - -� - -J NEW 16X 16 RAG 6 »� CEILING - O ii iI _ = 10 EXISTING -9 iI W. C• II EF- r� o o KITCHEN CG 8X8 1W 2 6 L -1 D 60 CFM iI EX II T. \/ - AT ° T_ NEW 161'\116 RAG �1 O CEILING 0J E - - - - - -- — NE HU -1 I A/ 6')0 - I RE IF— HANGEf;R5 ANA 6Ui=i=0fRT6 NOTE: LIMIT FLEXIBLE DUCTS TO THE FLEXIBLE CONNECTORS TO 14 FEET MAXIMUM LENGHT. FLEXIBLE DUCTS MUST BE PROVIDED WITH METAL LINER. MECHANICAL PLAN SCALE: 1/4" =1' -0" FAN - -COIL DE51CsNATION GFM MBTUH ENTERINGr F ELECTRIC AL DATA MANUFAC, REF. UNIT OBS TOTAL 5EN51BL 11.15 D15 VOLTS PHA5E5 HTNCs KW gt4 FU5ES LIG2. 5UG. CONE) AHU -1 1600 46.0 3125 67 a0 240 1 9.6 42 ro0 RHEEM RHLLHM4a21JA 3/0 7/a 1 CCNDENSINCi UNIT IDESICaNATION MBTUH TEMP. ENT. CONDENSER ELECTRICAL DATA MANUFAC. UNIT OB5 OR SEER AREA SERVED VOLTS PHASES WIRE AM FS FUSE5 CU -1 46.0 95 240 1 21 50 RHEEM 14AJM49AOI 16.0 SHOWN mu ARCHITECT ORESTES LOPEZ -RECTO AR0009350 5895 &W. 32 STREET MIAMI, FLORIDA 33155 TELEPHONE: (305) 608 -8887 OWNER: W U Z W 0 0 w z W wC'' .._I W ❑ �cy) O Z =< W J 0)O Q �� Z O ry L I--- Q Z Q L.� REVISIONS: 0 - 1>7 -13 ROV15ION BY O,UNI =R k DATE JANUARY a 2013 SCALE - AS SHOWN DRAWN WAC. JOB NO. 13 -2000 M -1 SHEET NO. OF