R13-122-006TYPE: LOAD CENTER / NEMA 1 MAIN 51,15: 200 A SERVICE: IPH, 3W / S/N PANEL "A" NEUTRAL: 200 A VOLTAGE: 120/240 V, IF, 3W MAIN: M.L.O MOUNTING: FLUSH (EXIST. FOR REFERENCE) AIC: 10,000 AIC TRIP POLE CON TOTAL V.A. WIRE 51ZE DESCRIPTION REMARKS CKT « REMARKS DESCRIPTION WIRE SIZE TOTAL VA. GOND TRIP POLE 60/2 RMX 10,570 6 NEW A.N.U. "1 lm KW + b-1 FAN (NC) (EXIST) 1 2 (EXIST) CU. "1 (N.C.) 6 9,000 RMX 60/2 3 4 50/2 RMX 12,000 6 RANCxE /OVE N (EXIST) 5 6 (EXIST) DRYER 10 5,000 RMX 30/2 1 S 20/1 RMX 1,200 12 REFRIGERATOR 9 10 (EXIST) WATER NEATER 6 5,500 RMX 5O/2 20/1 X 1,500 12 SMALL APPLIANCE5 GFI (NEW) 11 12 20/1 RMX 1,500 12 SMALL APPLIANCES GFI (NEW) 13 14 (EXIST) WASHER 12 1,200 RMX 20/1 20/1 RMX 1,500 12 SMALL APPLIANCES GFI (NEW) 15 16 (EXIST) MICROWAVE /HOOD 12 1,200 RMX 20/1 20/1 RMX O 12 BATH RECEPTACLE GPI (NEW) 11 IS (EXIST) DISHWASHER 12 1,200 RMX 20/1 15/1 RMX O 14 GEN. LIGHTING 4 RECEPT. (EXIST) 19 2 (EX15T) GARBAGE DISPOSAL 12 SOO RMX 20/1 15/1 RMX O 14 GEN. LIGI -ITING 4 RECEPT. (EXIST) 21 22 (EXIST) GEN. LIGHTING 4 RECEPT. 14 Q RMX 15 /I 15/1 RMX O 14 GEN. LIGHTING 4 RECEPT. (EXIST) 23 24 (EXIST) GEN. LIGHTING 4 RECEPT. 14 1 RMX 15/I 15/1 RMX O 14 GEN. LIGHTING 4 RECEPT_ (EXIST) 25 26 (EXIST) GEN. LIGHTING 4 RECEPT. 14 O RMX 15/1 15/1 RMX G 14 GEN. LIGHTING 4 RECEPT. (EXIST) 21 28 (EXIST) GEN. LIGHTING 4 RECEPT. 14 RMX 15/1 15/1 RMX 14 GEN. LIGHTING 4 RECEPT. NEW 29 3 (NEW) GEN. LIGHTING 4 RECEPT. 14 lO RMX 15 /i SPACE 31 32 SPACE SPACE 33 34 SPACE 35 36 31 35 39 4 41 42 11,100 TOTAL TOTAL 14,1300 NC - - - -- -NOT COUNTED LOAD VERIFY MANUFACTURE SPECIFICATIONS SUB TOTAL LOAD: 32,600 (D FLOOR AREA= 2,151 SRw 3 WATTS = 6,453 NEW TOTAL LOAD (WITH ADDITION) 39,053 ELECTRICAL SYMBOL LEGEND O JUNCTION BOX HIGH HATS LIGHTING OO MINI HIGH HATS LIGHTING VP VAPOR PROOF O CEILING MOUNTED FIXTURE KEYLESS FIXTURE O CEILING MOUNTED FIXTURE F/L W /SUPPORT FOR FAN 8 LIGHT 1­0 WALL MOUNTED FIXTURE 0 1'X4' FLUORESCENT FIXTURE CxFI RECEPTACLE GF I SINGLE RECEPTACLE ® 2 POLE OUTLET RECEPTACLE SWITCHABLE DUPLEX RECEPTACLE GARBAGE DISPOSAL ELECTRIC PANEL z EXHAUST FAN WP WEATHER PROOF SWITCH $F FAN SWITCH $3 3WA1' SWITCH TELEPHONE Tv TELEVISION CABLE OUTLET DISCONNECT SWITCH NEW SMOKE /CARBON MONOXIDE DETECTOR SD COMBO (INTERCONNECTED) l\TC)TFq- NC ELECTRICAL LOAD CALCULATIONS (MAIN HOUSE PANEL - EXIST. TO REMAIN) I- SUBTOTAL 39.05 2- FIRST 10.00 KW e 100` 0 100 KW 3- REMAINDER 21305 KW 'a 40% 11.62 KW 4- 1 AIR CONDITIONING "I HEATER AMPS 240 SINGLE PHASE 3 WIRE 32,190 W /240 V = TOTAL LOAD SCOPE OF WORK: SUBTOTAL = 21-(o2 KW 10,5 -10 10.5 -1 <W GRAND TOTAL = 32.19 KW 134 AMPS ALL INTERIOR WIRING, LIGHT FIXTURES, OUTLETS, SWITCHES, BOXES AND ELECTRICAL PANEL TO REMAIN UNLESS OTHERWISE NOTED. NEW ELECTRICAL AS PER PLAN. EXIST. METER AND DISCONNECT BOX ARE EXISTING AT EXISTING STORAGE TO REMAIN. EXISTING PANEL IS SUFFICIENT FOR NEW ELECTRICAL WORK (SEE EXISTING PANEL ABOVE). EXISTING A.H.U. AND C.U. TO BE REMOVED AND REPLACED WITH NEW. 1- PROVIDE ARC -FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL BEDROOM BRANCH CIRCUIT RECEPTACLE OUTLETS. 2 -ALL AREAS SPECIFIED IN 210.52 ALL 125 -VOLT 15 AND 20 AMPERS RECEPTACLES SHALL BE LISTED TAMPER RESISTANT RECEPTACLES, NEC 2008 3 -NEW SMOKE DETECTOR SHALL BE HARDWIRED (110 VOLT TYPE) TO A NON- SWITCHABI_E BEDROOM LIGHTING CIRCUIT, WITH BATTERY BACK -UP. SMOKE DETECTORS TO BE CARBON MONOXIDE DETECTORS. 4 -BOXE6 IN OUTLETS IN CENTER OF: BEDROOMS, FAMILY, GYM AND DEN SHALL BE ABLE TO SUPPORT LAMP HOLDER5 AND FANS AS N.E.0 314.21 a 4 d 5 -ALL EXIST. KITCHEN RECEPTACLES SHALL BE REPLACED WITH NEW 204 G71 OUTLET AS PER N.E.G. ELECTRICAL NOTES 1) CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT FOR COMPLETE ELECTRICAL INSTALLATION IN ACCORDANCE WITH THESE DRAWINGS. 2) COMPLY WITH THE N.E.C. AND STANDARD BUILDING CODE, 3) PROVIDE EMPTY CONDUITS AS REQUIRED FOR TELEPHONE SYSTEM. 4) OBTAIN ALL PERMITS FOR WORK UNDER THIS CONTRACT. 5) PROVIDE TEMPORARY POWER AND LIGHT OUTLETS FOR USE BY OTHER TRADES. (o) PROVIDE ALL REQUIRED CONNECTIONS FOR OTHER TRADES. �) COORDINATE ALL OUTLET LOCATIONS WITH BUILDING ARCHITECTURAL FEATURES. 8) CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. (EI) ALL GABLE SHALL BE COPPER_ 10) ALL MOUNTING HARDWARE SHALL BE BY CONTRACTOR. 11) OUTDOOR UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC. UNDER PAVED AREAS IT SHALL BE ENCASED IN CONCRETE. MINIMUM COVER SHALL BE 24 INCHES. 4RE,4 OF CONSTRUCT ION I ELECTRICAL PLAN SCALE: 1/4" =1' -0" &H ARCHITECT ORESTES LOPEZ -RECTO AR0009350 5895 S.W. 32 STREET MIAMI, FLORIDA 33155 TELEPHONE (" 608-8887 OWNER- W 0 z W 0 ® w Il ®1 w w Q co < �(y) z :E _0 Lu F— z O Co 1J_ lid 2E z N. 1..1� 75 REVLSTONS: 0 5.1$.13 REVISION BY OWNER SEAL;) , ., Z ,k; • ,. �a DATE JANUARY 18, 20B SCALE = AS SHOWN DRAWN WAC. JOB NO. B -2000 E -1 SHEET NO. OF