R13-122-002
DOOR SCHEDULE DOOR 1,828 5Q- FT. FRAME 84 5Q. FT. REMARKS NO. W �4 T MAT. TYPE GLASS MAT. DET. 1 O 6' -0" 7' -0" 1 3/8" ALUM / GLASS. FRENCH IMPACT METAL WOOD WEATHER STRIP, TEMP_ GL., LEVER HARDWARE IMPACT RESISTANT W/ MATCHINCz SIDE -LITE5 O2 2' -6" 6' -8" 1 3/0" WD. RAISED PNL WD, MARBLE SADDLE AT BATHROOMS 13/8" WD BI -PASS WD, 2 DOOR/ 2 TRACK BI -PASS DOOR 13/8" WD. BI -PASS WD. 2 DOOR/ 1 TRACK SURFACE MOUNTED * DENOTES DESIGNATED EMERGENCY MEANS OF SCAPE WHEN SHUTTERS HAVE BEEN INSTALLED. NO SHUTTERS THIS DOOR. DOOR MUST BE IMPACT RESISTANT. ** G.C. TO PROVIDE 1" UNDER CUT CLERANCE AT ALL INTERIOR DOORS. NOTES: 1. CONTRACTOR SHALL COORDINATE ALL MASONRY OPENINGS PRIOR TO BLOCK WALL & TIE BEAM ERECTION.. 2. ALL WINDOWS SHALL COMPLY W/ ENERGY CALCULATIONS. 3. ALL FIXED GLASS SHALL BE TEMPERED GLASS. 4. GC SHALL SUBMITT ALL SHOP DRAWINGS FOR CITY OF MIAMI REVIEW AND APPROVAL PRIOR TO FABRICATION AND INSTALLATION. ARCHITECT'S /ENGINEER REVIEW APPROVAL REQUIRED PRIOR TO SUBMITTAL. CLASS II SAFETY GLASS SRFQUIREMENTS: (WITHSTAND 400 LB / L.F IMPACT TEST.) 1, GLASS PANELS ADJACENT TO DOORS MUST BE INDICATED TO BE OF CATEGORY II SAFETY GLAZING - F.B.C. 2405.2.1(3) & (4). 2. GLASS IN SHOWER ENCLOSURES MUST BE OF CATEGORY IISAFETY GLAZING F.B.0 2405.2.1 (1) & 2411.3.1.3.2. 3. GLASS IN WINDOWS ADJACENT TO TUBS AND SHOWER COMPARTMENTS MUST BE CATEGORY II SAFETY GLAZING F.B.C. 2411.6.2. 4 GLAZING IN AN INDIVIDUAL FIXED OR OPRABLE PANEL ADJACENT TO DOORS WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24" RADIUS OF THE DOOR IN A CLOSE POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60" ABOVE THE FLOOR OR WALKING SURFACE MUST BE OF CATEGORY II SAFETY GLAZING F.B.C. 2405.2.1(3). WALL LEGEND: INDICATES EXISTING BUILDING ELEMENT TO REMAIN, INDICATES NEW 8 "x8 "x16" MASONRY UNITS R -4.2 INSULATION IN CAVITY. INDICATES NEW 3 -5/8" METAL STUDS PARTITION 24" O.C. WITH 11/2" DRYWALL FINISH EACH SIDE. INDICATES EXISTING 8 "x8 "x16" MASONRY UNITS W/ NEW 1/2" G.W.B AND R -4.2 INSULATION IN CAVITY (INSIDE FACE). AREA TABULATIONS EXISTING A/C SPACE: 1,828 5Q- FT. EXISTING COVERED ENTRY: 84 5Q. FT. EXISTING GARAGE SPACE: 323 5Q. FT. TOTAL: 2,235 50. FT, PROPOSED NEW A/C SPACE ADDITION 328 5Q. FT. GRAND TOTAL 2,563 SQ. FT, GENERAL NOTES: I. BATHTUB AND SHOWER FLOORS AND WALLS ABOVE 5ATHTU55 WITH INSTALLED SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FT ABOVE FLOOR. SECTION R3012 OF F.B.G. 2001. 2. IN AN OUTSIDE WINDOW OR DOOR OPERABLE FROM THE INSIDE, THE MODE OF OPERATION SHALL NOT REQUIRE THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE OR EFFORT. SUCH CLEAR OPENING SHALL BE NOT LESS THAN 20" IN WIDTH, AND 24" IN HEIGHT, 5.7 50. FT. IN AREA THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44" ABOVE THE FINISHED FLOOR AND NO PART OF THE OPERATING MECHANISM SHALL BE PLACED HIGHER THAN 54" ABOVE FINISHED FLOOR. 3-41--l- HABITABLE ROOMS, BATHROOMS AND OTHER LOCATIONS OF THE HOUSE, SHALL COMPLY WITH LIGHT, VENTILATION AND HEATING REQUIREMENTS DESCRIBED ON SECTION IR303 OF F.B.G. 2007. 4. ALL GLAZING ELEMENTS INSIDE AND/OR OUTSIDE OF CONSTRUCTION HAVE TO BE DETERMINATED AND INSTALLED AS PER SECTION 8308 OF F.B.C. 200-1- 5. REFER TO FOUNDATION PLAN FOR CONCRETE. FILLED BLOCK CELL LOCATION FOR SIZE AND REINFORCING. 6. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMICIDES, INCLUDING SOIL APPLIED PESTICIDES, BAITING SYSTEMS, AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED FOR USE A5 PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPT. BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: THE BLDG, HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUB- TERRANEAN TERMITES. TREATMENT 15 IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FL. DPT. OF AGRICULTURE AND CONSUMER SERVICES." (SECTION R320 F.B.C. 2007.) 7. BASEMENTS WITH HABITABLE SPACE AND EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPEN,45LE EMERGENCY ESCAPE AND RESCUE OPENING. AREAS AND OTHER REQUIREMENTS SHALL COMPLY WITH SECTION IR310 OF F.B.G. 2007. 8. STAIRWAYS, RAMPS, EXTERIOR BALCONIES, HALLWAYS AND DOOR SHALL COMPLY WITH MEANS OF EGRESS SECTION (8311) OF F.B.C. 2001. 9. INSULATION MATERIAL WITHIN ROOF - CEILING ASSEMBLIES SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED 25 WITH AN ACCOMPANYING SMOKE - DEVELOPED INDEX NOT TO EXCEED 450. F.B.G. 2007 8316.1 FLOOR PLAN LEGEND: ® G.W,B. SOFFIT ,45V. MATCH EXIST. CLG. NEW A.N.U. (SEE MECHANICAL PLAN) © NEW C.U. (SEE MECHANICAL PLAN) DO NEW CONCRETE 5TEP5. 0 36" HGT. VANITY TEMP. GL. SHOWER ENCLOSURE O BUILT -IN STORAGE 0 16 "X16" G.W.B. TILED NICHE r d n PROPOSED FLOOR PLAN ,a a SCALE: 1/4" =1 ° -0" I rel ARCHITECT ORFSM LOPEZ -RECIO AR0009350 5895 S,W. 32 STREET MIAMI, FLORIDA 33155 TELEPHONE; (" 608 -8887 OWNER- w C) z W i— V J z W cj� wcy' w, ® e( �m � z =� ~� Cy) ® uj z LL z ®� O LO 0 Q z Q REVISIONS: Q rp.11;.13 REVISION B1' OWNER ° a m DATE JANUARY 18, 2013 SCALE AS SHOWN DRAWN WAC. JOB NO. B -2000 A-2 SHEET NO. OF