Fire Alarm Symbol Legend
PHOTOELECTRIC SMOKE DETECTORS
NOTIFIER * NP - 100
DUCT SMOKE DETECTOR NOTIFIER
DNR- NP10OR WITH SAMPLING TUBES
H� HEAT DETECTOR NOTIFIER NH -100
FACP FIRE ALARM ADDRESSABLE PANEL
FACP NOTIFIER NFW -2 -100 PROVIDED WITH (2)
LINE DIALER, POWER SUPPLIES BATTERIES,
ETC., AS REQIRED. PROVIDE "LCD" REMOTE
ANNUNCIATOR "LCD 801'
.
fire
i
v �
L- I STAIRWAY
i
r -- AD
BATi
;- -ref -to = Fil
; of egress
fire
CORR
BREAKROOM
0 ADA STROBE NOTIFIER * SR
(SEE FLOOR PLANS FOR CANDELA
REQUIREMENTS)
L
Q PULL STATION NOTIFIER * NOT - BG - 12X
Fire Alarm Notes
ADA HORN /STROBE NOTIFIER P2R
SERIES (SEE FLOOR PLANS FOR
CANDELA REQUIREMENTS)
1. FIRE ALARM SYSTEM SHALL BE U.L. LISTED NFPA 72 APPROVED.
8. VISUAL ALARMS PER ANSI A 117.1,4:26, AND A.Da
2. UPON ACTIVATION OF FIRE ALARM SYSTEM BY MANUAL STATION,
9. ACTIVATION OF SMOKE DETECTOR IN ANY ELEVATOR LOBBY OR ASSOCIATED
THE FOLLOWING SHALL TAKE PLACE:
ELEVATOR MACHINE ROOM, OTHER THAN AT THE DESIGNATED LEVEL, SHALL
A ENERGIZE ALARM SIGNALING DEVICES
CAUSE ALL CARS THAT SERVE THAT LOBBY TO RETURN NON -STOP TO THE
B SOUND AUDIBLE ALARMS AND FLASH VISUAL SIGNALS
DESIGNATED LEVEL. THE OPERATION SHALL CONFORM TO THE REQUIREMENTS
C ALERT LOCAL FIRE DEPARTMENT OR PROPRIETARY SYSTEM
OF RULE 211.3a OF ASME /ANSI A17.1 -1987 AS ADOPTED BY CHAPTER
D CAUSE ZONE IN ALARM TO DISPLAY ON THE ANNUNCIATOR
4A °47 OF THE DEPARTMENT OF INSURANCE, STATE FIRE MARSHALL.
3. ALL WIRING AND CONDUIT SIZES SHALL BE IN ACCORDANCE
NO DEVICE OTHER THAN PHASE I SWITCH (RULE 221.30) OR THE DETECTOR
WITH MANUFACTURER'S RECOMMENDATIONS, AND
IN THE ELEVATOR LOBBY OR ASSOCIATED MACHINE ROOM SHALL INITIATE
REQUIREMENTS OF NEC, LOCAL CODES AND NFPA. IN NO CASE.
PHASE I OPERATION.
SHALL THE WIRING BE SMALLER THAN # 16.
IF THE SMOKE DETECTOR AT THE DESIGNATED LEVEL IS ACTIVATED,
4. ALL CONDUCTORS SHALL BE COOPER AND SHALL BE SIZED FOR A
THE CARS SHALL RETURN TO AN ALTERNATE LEVEL APPROVED BY
MAXIMUN LOSS OF IdB. MINIMUM WIRE SIZE SHALL BE AS REQUIRED
ENFORCING AUTHORITY, UNLESS THE PARSE I SWITCH (RULE 221.3a)
BY MANUFACTURER IN NO CASE. SHALL THE WIRING BE SMALLER THAN
IS IN THE ON POSITION,
# 16 F.P.L. CU IN. 3/4 CONDIUT.
5. QUANTITY OF WIRES PER DEVICES SHALL BE AS REQUIRED
10. SMOKE DETECTORS TO BE MOUNTED 3FTMINIMUM FROM ANY A/C DIFUSSER.
BY MANUFACTURER.
6. RISER INTERCONNECTIONS ARE DIAGRAMMATIC ONLY.
11. THESE PLANS ARE A GUIDE FOR THE INSTALLATION OF THE FIRE ALARM SYSTEM
CONTRACTOR IS RESPONSIBLE FOR PROVIDING COMPLETE FIRE ALARM PERMIT
7. SYSTEM TO BE POWER LIMITED.
DRAWINGS SIGNED AND SEALED BY A FLORIDA REGISTERED ENGINEER,
TO THE BUILDING DEPARTMENT FOR PERMIT.
SD
1 1 I
1 t 1
1
j S AHU •3
10' -0"
I.T. ROOM
.� SD
H 175cd
(floor tr
/4" max.
L
L 1.,_
75cd
7L5. RECEPTION AREA
- egress path f
(floor if ions 1/4" max.)
refer to FireSety Plan -
Leve12 for c tinuation
of egres _path_ -_- -..
,-�E
Q;
O
�2
SD
to
O
;
H 1
F
STAIR
LANDING
ADMINISTRATION
ENTA L
IPPLIES
75cd1 H
,t - - - - - - - _,
1
1 ,
1 Q AHU •4
PREP/
STERILE AREA
�--- fire
extinguisher
egress path
•E
I ,
r ,
i '-
i ;
r
� ' N
4 ; c
0
�l; 1
N
C
SD ; 0
I ; o
o
= v
------- --- --- ---- - - - - -- --
' T
�\ OFFICE
i
i
+
10' -0"
SD
OPT.. I --
OPT. -- - =�-_.
YGIENE
--------- - -� - --
`4-all building components within
a 10' -0" distance of egress stairs
shall have a 1 hour minimum fire rating
as per N.F.P.A. 7.22.63 (separtion &
protection of outside)
: Fire Alarm Floor Plan - Level 3
1/4" = 1'-0"
"I Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
Total 3rd Level (under air) Area:
}- Total 3rd Level (Terrace) Area:
�- Number of occupants (under air):
(1 occupant per 100 Sq. Ft.)
Number of occupants (Terrace):
(l occupant per 7 Sq. Ft.)
>' Total 3rd Level Occupant Load:.
L gg, . J
� �U�' %I��"�'(I tr;?S ,t E..,..
rt:3C,iLL711_'E�/ }'LTAc S3i +#XT',27P:.
Am), Tved for btuvclin I'erhr�it o�rlyi
I�
L
2432 Sq. Ft.
190 Sq. Ft.
25
53
L P e o s Building Occupancy: Business / Commercial ( Medical Offices )
Proposed Building Occupancy: Business / Commercial (Medical Offices)
Special Notes:
1. This project scope is a reconstruction as per F.P.C. 43.6
2. This is a Business Occupancy only. These medical offices do not contain
any sub - tenancy.
3. The existing building does not contain a fire sprinkler system.
4. All exterior doors and windows within the 10' -0" of the proposed stairs will
have a minimum 1 hour fire rated wall system assembly and a 45 min.
rating for openings.
5. G.C. shall submit new door and window replacements under separate
permits.
A J�
Bt�OCKHOUSE 1
B:.20CT {!40 —;SE ASSOCIATES PA
4973 S. W. 75th AVENUE
M:(AMI, - 1- 1,0RIDA 33155
S05 665 2333 b FAX 666 2332
AV, RNA�
1. ... •
ARCHITECTURE ■ INTERIOR DESIGN
PROJECT
An Interior Renovation to
the Medical Offices of:
DR. SANDINO
GONZALEZ
6150 Sunset Drive
South Miami, Florida 33143
SEAT,
r+
1 INNOVATIVE
E ENGINEERING
GROUP, INC.
SUDHIR K. GUPTA
P.E. # 29189
5532 N.W. 72 AVE. MIAMI, FLORIDA 33166
305 - 888 -9626
SHEET TITLE
FIRE ALARM
FLOOR PLAN -
LEVEL 3
SHEET TITLE REFERENCE
12018- fire3.d n
J
ALL CONCEPTS, DESIGNS, ARRANGEMENTS, DRAWINGS AND
SPECIFICATIONS ARE OWNED BY AND ARE THE PROPERTY OF
THIS OFFICE AND WERE CREATED, EVOLVED AND DEVELOPED
FOR USE ON, AND IN CONJUNCTION WITH, THE, SPECIFIED
PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS
OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON,
FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER
WITHOUT THE WRITTEN PERMISSION OF:
BROCKHOUSE ASSOCIATES, PA.
REVISION
1 Q8- 14 -12: PERMIT REVISIONS:
(FIRE)
�8- 31 -12, ADDITIONAL PERMIT
2 REVISIONS - (FIRE)
DESIGNED BY
B.A.
DRAWN BY
B.A.
APPROVED BY
S.G.
DATE
7 -13 -12
SCALE
1 /4 " =1 -0"
PROJECT NO.
12018
SHEET N0.
FA.3