Loading...
12-729-033PLUMBING LEGEND SYMBOL DESCRIPTION SANITARY WASTE PIPING - COLD WATER PIPING (CW) - -- 1407 HOT WATER PIPING (HW) - - - -- 185'F HOT WATER PIPING (HHW) - - - - - SANITARY VENT PIPING CD - CONDENSATE DRAIN PIPING SD - STORM DRAIN PIPING OSD -- OVERFLOW STORM DRAIN PIPING RWL RAIN WATER LEADER ORWL OVERFLOW RAIN WATER LEADER -��- GATE VALVE �- CHECK VALVE "P" TRAP TLr- --j-■ HB HOSE BIBB (HB) WATER HAMMER ARRESTOR VTR VENT THRU ROOF CO I-- CLEAN OUT FCO FLUSH FLOOR CLEAN OUT W�%TPIXJ FLOOR DRAIN WITH TRAP PRIMER COOG CLEAN OUT ON GRADE FD FLOOR DRAIN V VENT TRAP PRIMER (RESEAL) TO CLOSEST FIXTURE 0 RD ROOF DRAIN 0 ORD OVERFLOW ROOF DRAIN - FOS - FUEL OIL SUPPLY PIPING -FOR - FUEL OIL RETURN PIPING NOTE: SYMBOLS INDICATED MAY NOT BE USED ON DRAWINGS TEST TEE THREADEC CLEANOUT WALL CLEAN OU T (NOT TO SCALE) r UL1479 UL2079 UL FIRE RESISTANCE DIRECTORY: A. FILLS, VOIDS OR CAVITY MATERIALS (XHHW) B. FIRESTOP DEVICES (XHJI) 3 -,- + +� 1. PRE -RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY 2. METALLIC PIPE: A) STEEL PIPE -12" 0 (OR SMALLER) SCH. 10 (OR HEAVIER) STEEL PIPE. B) IRON PIPE -12 "0 (OR SMALLER) CAST OR DUCTILE IRON PIPE. C) COPPER TUBING - 4 "0 (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. D) COPPER PIPE - 40 (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. E) CONDUIT - 4"0 (OR SMALLER) EMT OR 6" 0 (OR SMALLER) STEEL CONDUIT. THE ANNULAR SPACE SHALL BE MIN. 0" TO MAX 1" WITHIN THE FIRESTOP SYSTEM. 3. TREMSTOPIA- MIN'' /z" THICKNESS OF SEALANT APPLIED WITHIN OPENING. MIN 318" CAN'T BEAD OF SEALANT TO BE APPLIED AT AREAS OF POINT CONTACT. 5 F, 4 1. PRE -RATED GYPSUM WALLBOARDISTUD WALL ASSEMBLY 2 2. PLASTIC PIPE - NOM. 4"0 (OR SMALLER) SCH. 40 PVC PIPE FOR USE IN CLOSED OR OPEN PIPING SYSTEMS. SEE TABLE BELOW FOR REQUIRED ANNULAR SPACE. 3. TREMSTOP WS - INTUMESCENT WRAP STRIP, CONTINUOUSLY WRAPPED AROUND OUTER CIRCUMFERENCE OF THE PIPE. SEE TABLE BELOW FOR MIN. WRAPS REQUIRED. PIPE DIAM. ANG. SPACE # OF WRAPS 2 3116 3 3 1/8 4 4 118 6 4. TREMSTOP MCR - PREFABRICATED STEEL COLLAR WRAPPED OVER THE WRAP STRIPS (ITEM 3) AND MECHANICALLY FASTENED TO BOTH SIDES OF WALL ASSEMBLY. TREMSTOP 1A OR TREMSTOP ACRYLIC (OPTIONAL) - MIN %" BEAD OF SEALANT APPLIED AT THE 5. WALLBOARD /DEVICE AND DEVICE/PIPE INTERFACES. NOTE: TREMSTOP D CAN BE USED IN PLACE OF TREMSTOP WS AND TREMSTOP MGR. "TREMCO" MODEL: TREMSTOP IA FOR 1 OR 2 HOUR FIRE RATED PENETRATION FOR SINGLE METALLIC PIPE THRU GYPSUM WALL FIRE STOPPING DETAIL, N.T.S. COVER SECURED WITH SCREWS THREADED C.O. PLUG r- FIN. GRADE 4 X 6" DIA. CONCRETE PAD FLUSH W /FIN. GRADE ACCESS COVER AND FRAME FINISHED WALL SURFACE SLIP JOINT ADJUSTABLE COLLAR THREADED C.O. PLUG FIN. FLOOR -7 "TREMCO" MODEL: TREMSTOP D FOR 2 HOUR FIRE RATED PENETRATION FOR SINGLE PLASTIC PIPE THRU GYPSUM WALL renr OF WALL EXTERIOR TYPE FLOOR WALL TYPICAL CLEANOUT DETAIL N.T.S. "CO" TO BE CAST CONCRETE PAD IN COVER GRADE OR PAVING -� \ r- CLEANOUT WITH COVER LONG SWEEP 1/4 BEND OR IRONCOMB, "Y" AND 1/8 BEND. (USE REDUCING TYPE WHERE REQUIRED.) PLUG. FINISH FLOOR EXTENSION - SAME SIZE AS SEWER UP TO 4" DIA. BUILDING DRAIN OR SEWER MATERIAL '-DIRECTION OF FLOW AND SIZE AS SPECIFIED. EXTERIOR CLEAN OU T INTERIOR FLOOR CLEAN OU T (LIGHT TRAFFIC AREA) DETAIL OF CLEAN OU TS (NOT TO SCALE) PLUMBING SPECIFICATION 1. GENERAL: MATERIAL SHALL BE NEW, UNUSED, BEST OF THEIR RESPECTIVE KINDS AND FREE FROM DEFECTS IN WORKMANSHIP; IN CONFORMANCE WITH THE LATEST PUBLICATIONS IN FORCE AT TIME OF BIDDING. 2. PIPE AND FITTINGS: A. DRAINAGE WASTE AND VENT PIPING INCLUDING: PVC DRAINAGE WASTE AND PIPING (DWV) CONFORMING TO ASTM D -2665, UNDERGROUND NO HHUB CAST IRON CISPI STANDARD 301 ABOVE GROUND AND CAST IRON HUB, PLAIN END ASTM A -74 WITH NEO- PRENE GASKETS UNDERGROUND. INSTALL PLASTIC (PVC) PIPES ONLY WHEN ITS APPROVED BY LOCAL AUTHORITIES AND NOT TO BE USED IN AIR RETURN PLENUM. B. DOMESTIC WATER SUPPLY PIPING: COPPER PIPE TYPE 'L' WITH BRONZE OR WROUGHT COPPER SOLDER JOINT FITTINGS, ASTM.B88 -78. C. NOT USED D. STORM DRAIN PIPING: AS HEREIN BEFORE SPECIFIED FOR SANITARY SOIL, WASTE AND VENT PIPING. 3. JOINTS AND METHODS OF CONNECTION: A. DWV COPPER PIPE: JOINT WITH 95 -5 TIN - ANTIMONY SOLDER, INSTALL PER MANUFACTURER'S RECOMMENDATIONS. B. TYPE 'L' COPPER TUBE: JOIN WITH 95 -5 TIN - ANTIMONY SOLDER, INSTALL PER MANUFACTURER'S RECOMMENDATIONS. C. STEEL PIPE: a. THREADED JOINTS: AFTER CUTTING AND BEFORE THREADING, REAM ALL PIPE AND REMOVE BURRS. MAKE JOINTS WITH JOINT COMPOUND APPLIED TO MALE THREADS ONLY. b. FLANGED JOINTS: STANDARD WEIGHT, 150 P.S.I. STEEL, WITH APPROVED RED RUBBER GASKET OR NEOPRENE RUBBER GASKET, INSTALL AS PER MANUFACTURER'S RECOMMENDATIONS. 4. UNIONS AND FLANGES: A. COPPER PIPE: BRONZE UNIONS FOR 2 INCHES AND SMALLER. FOR 2 -1/2 INCHES AND LARGER USE BRONZE FLANGED CONNECTIONS 150 POUND CLASS. B. DIELECTRIC UNIONS OR FLANGES: UNIONS SHALL MEET DIMENSIONAL REQUIREMENTS AND TENSILE STRENGTH OF PIPE UNIONS IN ACCORDANCE WITH FED. SPEC. WW -U -531 E. UNIONS OR FLANGES SHALL BE SUITABLE FOR REQUIRED OPERATING PRESSURES AND TEMPERATURE CONDITIONS. UNIONS SHALL HAVE METAL CONNECTIONS ON BOTH ENDS. ENDS SHALL BE THREADED OR SOLDERED TO MATCH ADJACENT PIPING. METAL PARTS OF UNION OR FLANGED SHALL BE SEPAREATED TO PREVENT CURRENT FLOW BETWEEN DISSIMILAR METALS. EPCO DIELECTRIC PIPE FITTINGS OR EQUIVALENT. 5. ESCUTCHEONS: CHROME PLATED OR STAINLESS STEEL WITH SET SCREWS FOR HOLDING SECURELY IN PLACE. USE ESCUTCHEONS ON PIPES PASSING THROUGH WALLS, FLOORS AND CEILINGS OF FINISHED AREAS. 6. PIPE INSULATION. A. ALL CONDENSATE LINES SHALL BE INSULATED WITH 3/4" FIRE RETARDANT ARMAFLEX INSULATION WITH A MAXIMUM OF 25/50 FLAME SPREAD AND SMOKE DEVELOPED RESPECTIVELY. B. ALL HOT WATER AND TEMPERED WATER LINES SHALL BE INSULATED WITH 1" FIRE RETARDANT ARMAFLEX INSULATION WITH A MAXIMUM OF 25/50 FLAME SPREAD AND SMOKE DEVELOPED RESPECTIVELY. 7. INSTANT -FLOW WATER HEATERS SHALL BE OF THE CAPACITY AND GAS CHARACTERISTICS INDICATED ON PLANS AS MANUFACTURED BY SPECIFIED. 8. TRAP PRIMER SHALL BE SELF PRIMING TYPE ON COLD WATER SUPPLY LINE AS MANUFACTURED BY PRECISION PLUMBING PRODUCTS, INC. "PRIME -RITE" #PR -500. WHEN TWO OR MORE TRAPS REQUIRE PRIMING, PROVIDE WITH DISTRIBUTION UNIT #DU -2, 3 OR 4 AND SUPPLY TUBE #SS -8 ASSEMBLY. PROVIDE ACCESS PANEL AND INSTALL AS PER MANUFACTURER'S RECOMMENDATION. NUT _lIIS HAN PIPE 0.1 ULATION PIPE NSULATIO ADDLE . V. SHIELD PIPE PIPE W/ INSULATION W /OUT INSULATION PIPE HANGERS- CLEVIS TYPE DETAIL N.T.S. 1 1/4' PLUMBING GENERAL NOTES A. FILED VERIFY ALL EXISTING INFORMATION. 1;0DEALL WORK SHALL BE DONE IN ACCORDANCE WITH FLORIDA PLUMBING SITE INVESTIGATION: EXAMINATION OF CONTRACT DOCUMENTS AND SITE OF WORK; THE BIDDER IS REQUIRED, BEFORE SUBMITTING HIS PROPOSAL, TO VISIT THE SITE OF THE PROPOSED WORK AND FAMILIARIZE HIMSELF /HERSELF WITH THE NATURE AND EXTENT OF THE WORK AND ANY LOCAL CONDITIONS THAT MAY IN ANY MANNER AFFECT THE WORK TO BE DONE AND EQUIPMENT, MATERIALS AND LABOR REQUIRED THEREFORE. SINCE THE WORK INVOLVES EXISTING BUILDINGS, SYSTEM AND FACILITIES, SPECIAL CONSIDERATION SHALL BE GIVEN TO EXAMINATION OF WORKING CONDITIONS, EXISTING FACILITIES AND ALL BUILDING STRUCTURES TO FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. VARIATIONS IN ROUTING AND /OR CONSTRUCTION SHOULD BE ANTICIPATED BY THIS CONTRACTOR AND ARE EXPRESSLY INCLUDED AS PART OF THE WORK WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER. IGNORANCE ON THE PART OF THE CONTRACTOR WILL IN NO WAY RELIEVE HIM OF THE OBLIGATION AND RESPONSIBILITIES ASSUMED UNDER THIS CONTRACT. `AIN11 0L•1:l11 3. CONTRACTOR WILL BE RESPONSIBLE FOR COODINATING HIS DEMOLITION WORK WITH OTHER TRADES, AND TO PROTECT FROM DAMAGE EXISTING SYSTEMS TO REMAIN. 4. CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF EXISTING PIPES BEFORE COMMENCING TO WORK AND MAKE MODIFICATIONS AS REQUIRED WITHOUT ADDITIONAL COST TO THE OWNER. 5. ALL PIPING SHALL BE INSTALLED RECESSED IN BLOCK WALLS, CHASES OR PARTITIONS. 6. EXISTING PIPES SERVING AREAS NOT COVERED BY THIS CONTRACT BUT IN SERVICE AT THIS TIME SHALL NOT BE INTERRUPTED EXCEPT AS A TEMPORARY INTERRUPTION COORDINATED WITH THE OWNER AND LANDLORD. 7. PLUMBING CONTRACTOR SHALL PAY ALL FEES, INSPECTION AND CONNECTION CHARGES REQUIRED, 8. PLUMBING CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND DIMENSIONS AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT. 9. COORDINATE ALL WORK WITH OTHER TRADES. 10. PLUMBING CONTRACTOR SHALL GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE. 11. PROVIDE SHOCK ABSORBERS SIZE, QUANTITY AND LOCATION AS PER P.D.I. STANDARDS. 12. PROVIDE SHUT -OFF VALVE FOR EACH GROUP OF FIXTURE AND EACH FIXTURE SUPPLY. 13. WHEREVER DISSIMILAR METALS ARE TO BE JOINED, A DIELECTRIC FITTING SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES. 14. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE ALL ROUGH -INS WITH THE MANUFACTURER BEFORE MAKING ANY INSTALLATION. 15. POTABLE HOT AND COLD WATER SYSTEMS SHALL BE "LEAD FREE" WITH LEAD CONTENT NOT EXCEEDING 0.2 PERCENT FOR SOLDER AND FLUXES AND 8 PERCENT FOR PIPE FITTINGS, FIXTURES AND TRIM. CONTRACTOR SHALL VERIFY MANUFACTURER'S COMPLIANCE. 16. ALL POTABLE HOT AND COLD WATER SYSTEMS SHALL BE FLUSHED CLEAR, STERILIZED WITH AN APPROVED SOLUTION AND THROUGHLY FLUSHED OF ALL RESIDUAL SOLUTION AFTER FINAL PRESSURE TESTS AND WITH ALL TRIM AND CONNECTIONS INSTALLED. 17, PROVIDE SHUT -OFF AND VACUUM BREAKER TO ALL HOSE BIBBS AND FAUCETS WITH HOSE -END CONNECTIONS. 18. ALL FLOOR DRAINS SHALL HAVE TRAP PRIMERS TO PROTECT THE SEAL OF THE TRAP. 19. PVC PIPING IS NOT ALLOWED IN RETURN AIR PLENUMS, IF RETURN AIR PLENUMS ARE USED, CONTRACTOR SHALL REPLACE ALL EXISTING PVC PIPING WITH CAST IRON OR COPPER PIPING. 20. DRAINAGE SYSTEM DESIGN IS BASED ON 1/8" PER FOOT MINIMUM FALL FOR PIPES 3" OR LARGER AND 1/4" PER FOOT MINIMUM FALL FOR PIPES 2" OR SMALLER, ANY DEVIATIONS SHALL BE APPROVED BY ARCHITECT /ENGINEER. 21. ALL VENT THROUGH ROOF OPENINGS SHALL BE OFFSETED TO A MINIMUM DISTANCE OF 3' -0" FROM PARRAPET WALL OR ROOF EDGE. SEE ARCHITECTURAL DRAWINGS FOR ROOF FLASHING. LEAD FLASHING WILL NOT BE ACCEPTED. 22. DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED WITH PRE - MANUFACTURED SLEEVE IN ACCORDANCE WITH FLORIDA PLUMBING CODE 404.6.4. THERE SHAM BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. CONDENSATE TRAP DETAIL N.T.S. C UNIT BROCKH0(SE� BROCKHOUSE ASSOCIAI ES PA 4 9 Y 3 J. W. / 5 t h A V E N U E MIAMI, FLORIDA 33155 305 666 -2333 ■ FAX 305 666 -2332 AR 10682AA 0002456 BRUCE BROCKHOUSE ARCHITECTURE ■ INTERIOR DESIGN PROJECT An Interior Renovation to the Medical Offices of: DR. SANDING GONZALEZ 6150 Sunset Drive South Miami, Florida 33143 SEAL t INNOVATIVE E ENGINEERING GROUP, INC. SUDHIR K. GUPTA P.E. # 29189 5532 N.W. 72 AVE. MIAMI, FLORIDA 33166 305 - 888 -9626 SHEET TITLE PLUMBING NOTES, LEGENDS AND DETAILS SHEET TITLE REFERENCE 12018- plumbldgn ALL CONCEPTS, DENTS, ARRANWNIS, WOO AND SPECf1GI110NS ARE OWED BY, AND ARE DE MOPERIY OF THIS OFFICE AND MERE CREATED, EVOLVED AND DEVELOPED FOR USE ON, AND N CONJUNCTION WR4, 1W SPEMU PMCT. NONE OF SUCH IDEAS, DESN?4S, ARRM40ENTS W PLANS RIK IE UH IN OR =00 '11) ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE MFIATSOEVER WTHOUT THE WRITTEN PERMISSION OR BRMOUSE ASSOCIATES, PA. REVISION DESIGNED BY B.A. DRAWN BY B.A. APPROVED BY S.G. DATE 7 -12 -12 SCALE 411 = 1 1 -011 PROJECT NO. 12018 SHEET NO. P,5