12-729-022HVAC General Notes: 1, THE WORK TO BE DONE UNDER THIS HEADING INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS, EQUIPMENT, PERMITS, FEES, INSPECTIONS, TESTS, INSURANCE, ETC. REQUIRED FOR THE COMPLETION OF THE HVAC SYSTEM SHOWN ON DRAWINGS AND /OR LISTED BELOW. 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE FLORIDA BUILDING CODE AND ALL LOCAL CODES. 3. CONTRACTORS SHALL VERIFY SPACE CONDITIONS AND DIMENSIONS AND SHALL COORDINATE WORK WITH ALL OTHER TRADES AT THE JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF DUCTWORK AND EQUIPMENT. 4. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION AND IN STRICT COMPLIANCE WITH ALL APPLICABLE CODES AND STANDARDS. 5. ALL AIR CONDITIONING SUPPLY AND RETURN DUCTWORK SHALL BE CONSTRUCTED OF 1 -1/2" THICK (R-6) RIGID FIBERGLASS WITH ANTIMICROBIAL COATING. DUCTWORK SHALL BE FABRICATED IN ACCORDANCE WITH MANUF'S. INSTRUCTIONS AND BULLETINS. USE R -4.2 IN CONDITIONED SPACE. 6. ALL OUTSIDE AIR AND EXHAUST DUCTWORK SHALL BE CONSTRUCTED OF ZINC COATED GALVANIZED SHEET METAL CONSTRUCTED IN ACCORDANCE WITH THE LATEST A.S.H.R.A.E. GUIDE AND S.M.A.C.N.A. RECOMMENDATIONS. 7. ALL DUCT SIZES SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. 8. FIRE DAMPERS SHALL BE INSTALLED WHERE INDICATED FOR ALL DUCTS PENETRATING FIRE BARRIERS. DAMPERS SHALL BE CONSTRUCTED AND INSTALLED TO CONFORM TO REQUIREMENTS OF N.F.P.A. 90 -A AND U.L. 555. FIRE DAMPERS SHALL BE 10OX FREE AREA WITH BLADE OUT OF AIR STREAM AND U.L. LISTED ACCESS PANELS SHALL BE PROVIDED FOR REPLACEMENT OF FUSIBLE LINKS. 9. FIRE DAMPERS IN FIRE RATED CEILINGS SHALL BE RADIANT CEILING DAMPERS INSTALLED IN ACCORDANCE WITH U.L., N.F.P.A. AND ALL LOCAL CODE REQUIREMENTS. PROVIDE FIRE DAMPERS IN ALL DUCT PENETRATIONS OF FIRE RATED CEILINGS. GRILLES SHALL BE STEEL. 10. PROVIDE ACCESS PANELS IN WALLS AND CEILINGS FOR ALL DAMPERS, CONTROL DEVICES, ETC. ACCESS PANELS SHALL BE MILCOR FLUSH TYPE. 11. ALL REFRIGERANT PIPING SHALL BE TYPE 'L' COPPER, TOGETHER WITH WROUGHT COPPER, SOLDER FITTINGS. JOINTS SHALL BE MADE WITH SILVER SOLDER OR 'SILFOSS'. 12. PIPE INSULATION: CONDENSATE PIPING SHALL BE INSULATED WITH Y4" FIRE RATED FLEXIBLE FOAM INSULATION, FINISHED, WHERE EXPOSED, WITH 2 COATS OF ACRYLIC LACQUER IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. REPAIR DAMAGED INSULATION ON EXISTING PIPING. 13. FLAME AND SMOKE RATING. ALL INSULATION PRODUCTS USED INSIDE THE BUILDING SHALL HAVE A MAXIMUM FLAME SPREAD RATING OF 25 AND A MAXIMUM SMOKE GENERATION OF 50 IN ACCORDANCE WITH TESTS OUTLINED IN N.F.P.A. 255. 14. VERIFY ALL VOLTAGES WITH ELECTRICAL CONTRACTOR BEFORE ORDERING ANY EQUIPMENT. 15. SUBMIT SHOP DRAWINGS OF ALL MATERIALS AND EQUIPMENT FOR APPROVAL PRIOR TO ORDERING OR FABRICATION, INCLUDING 1/4 " DUCT LAYOUT. 16. ALL EQUIPMENT AND MATERIALS SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR. metal roue quodront to be outside ii provide insulati where n upply :)Ion view) air flow Flexible Duct Connection Detail N.T.S. HVAC LEGEND 17. VIBRATION ISOLATION: ALL EQUIPMENT AS PER MANUFACTURER'S RECOMMENDATION OR AS SCHEDULED ON DRAWINGS. AHU Air Handler Unit 18. AIR DISTRIBUTION AND FANS SHALL BE AS SCHEDULED ON THE CU Condensing Unit DRAWINGS OR APPROVED EQUALS. 19. ALL OUTSIDE EQUIPMENT SHALL BE SECURED TO WITHSTAND EF Exhaust Fan MAXIMUM WINDS AS PER FLORIDA AND LOCAL CODES. o New Programmable Thermostat 20. ALL FAN DRIVES SHALL BE ADJUSTED TO DELIVER THE SPECIFIED OA CFM AGAINST THE ACTUAL STATIC PRESSURE OF THE INSTALLATION. S 21. PROVIDE SMOKE DETECTOR IN SUPPLY AIR DUCTS OF A/C UNITS ABOVE 2000 CFM TO AUTOMATICALLY SHUT -OFF FAN MOTOR PER NFPA -90A THRU A SIGNAL FROM FIRE ALARM PANEL. 22. THERMOSTAT SHALL BE LOW VOLTAGE HEAT COOL WITH FAN AND SELECTOR SWITCHES ON SUBBASE, MOUNT ON WALL WHERE SHOWN ON PLANS AS PER HANDICAP CODE REQUIREMENTS. PROVIDE KEY LOCK PLASTIC GUARDS. 23. TESTING* A. PRESSURE TEST ALL REFRIGERANT HIGH SIDE PIPING TO 275 PSIG. HOLD FOR 24 HOURS. LOW SIDE TO BE TESTED AT 150 PSIG. HOLD FOR 24 HOURS. AFTER TESTING EVACUATE SYSTEM TO 28 INCHES OF MERCURY GAUGE PRESSURE WITH VACUUM PUMP. HOLD FOR 24 HOURS WITH PUMP OFF. BREAK VACUUM WITH OPERATING REFRIGERANT. B. BALANCE AIR SYSTEM TO DELIVER QUANTITIES AT EACH OUTLET WITHIN 51 USING A.A.B.C. PROCEDURES AND TESTS. SUBMIT AIR BALANCE TEST RESULTS FOR APPROVAL PRIOR TO FINAL INSPECTION AND ACCEPTANCE. INSTALL BALANCING VOLUME DAMPERS AT EACH BRANCH DUCT TAKE -OFF FOR THIS PURPOSE. 24. SECONDARY DRAIN PAN FOR HORIZONTAL HANDLING UNITS SHALL BE MINIMUM 2 INCH DEEP. IN ADDITION TO SECONDARY DRAIN PAN, INSTALL FLOAT SWITCH IN THE PAN TO SHUT -OFF THE SYSTEM, SHOULD THE SECONDARY DRAIN PAN BE PLUGGED. 25. CONTRACTOR SHALL COORDINATE LOCATION OF ALL GRILLES WITH THE EQUIPMENT LAYOUT, AND LIGHTS. 26. ALL EQUIPMENT SHALL BE INSTALLED MAINTAINING RECOMMENDED CLEARANCES FOR AIR FLOW AND SERVICE. COORDINATE LOCATION WITH STRUCTURAL FRAMING. 27. FLEXIBLE DUCTWORK SHALL BE ROUND DUCTWORK REINFORCED WITH A WIRE HELIX AND INSTALLED WITH 11 /z" THICKALB DENSITY (R -6) FIBERGLASS COVERED WITH A VAPOR BARRIER OF ALUMINUM METALIZED POLYESTER FILM LAMINATED TO GLASS MESH. CONNECTION TO DUCT MAINS SHALL BE MADE WITH FITTINGS PROVIDED WITH TWIST RINGS, BUTTERFLY DAMPERS, QUADRANT OPERATORS, EXTRACTOR AND INSULATION GUARD. DUCTWORK SHALL BE CLASS I, U.L. 181, 'WIREMOLD' TYPE WK OR APPROVED EQUAL. USE R -4.2 IN CONDITIONED SPACE. 28. PROVIDE TURNING VANES IN ELBOWS GREATER THAN 45 DEGREES. 29. ALL METAL DUCTWORK VISIBLE THRU GRILLES SHALL BE PAINTED FLAT BLACK (2 COATS). 30. CONTRACTOR SHALL VISIT THE JOBSITE PRIOR TO BID AND BECOME FAMILIAR WITH THE EXISTING CONDITIONS. ANY CLARIFICATION REQUIRED SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION. NO EXTRAS SHALL BE ALLOWED FOR FAILURE TO DO SO. 31. EXISTING DUCTWORK NOT INDICATED TO BE REUSED SHALL BE REMOVED AND DISPOSED OF AS PER ARCHITECT'S INSTRUCTIONS. sound insul( hou adjustable mounting flonge removable aluminum ceiling grille AIR FLOW AIR FLOW exhaust duct (round or rectangular) ugol fon inside 9 Typ. Ceiling Type Exhaust Fan Detail N.T.S. EXHAUST FANS, EF -1 thru EF -5 'NUTONE' model QTXE -80 or equivalent, 80 CFM, 115V, 0.5 Bones. provide backdraft damper and speed controller. Outside Air Thermostat Sensor in Return Air Duct -� MV Manual Volume Damper -1 MOD Motorized Damper Normally Closed SMOKE DAMPER(S) (open when AHU is 'ON') --- - - - - -- 0 Duct Mounted Smoke Detector FIRE RATED ROOF /FLOOR CEILING ASSEMBLY (compatible with the fire alarm system) '--" °-"""' Existing Equipment to Remain SMOKE CONTROL New Equipment or Ductwork PATTERN CONTROLLER New Flexible Ductwork HVAC Design Requirements Yes No DUCT SMOKE DETECTORS • (as FIRE DAMPER(S) • SMOKE DAMPER(S) • FIRE RATED ENCLOSURE • FIRE RATED ROOF /FLOOR CEILING ASSEMBLY • FIRE STOPPING • SMOKE CONTROL • PATTERN CONTROLLER 14 Outside Air Calculation (as per Florida Mechanical Code) Accessories Area Served Area S.F. PERFORATED O.A. CFM Required 'Titus' PCS - AA O.A. CFM provided 2nd Level 1246 PATTERN CONTROLLER 14 persons x 5 cfm /pers. - SUPPLY AIR 145 CFM 'Titus' PCS - AA CEILING DIFF. Q.06 cfm /SF x 1246 SF 24" X 12" FACE North 'C' - 145 CFM CEILING GRILLE - " "" 'Titus' PAS - 24" X 24" 2nd Level 1485 CEILING GRILLE 14 persons x 5 cfm /pers. - 'E' 200 CFM South 'Titus' ML-37 0.06 cfm /SF x 1485 SF 2 SLOTS 'F' RETURN AIR CEILING LINEAR LINED PLENUM 'Titus' MLR-37 2 SLOTS -160 CFM DRAINABLE BLADES 3rd Level 'G' INTAKE 14 persons x 5 cfm /pers. (see Note 2 below) 1198 0.06 cfm /SF x 1198 SF 145 CFM North - 142 CFM 3rd Level 12 persons x 5 cfm /pers. 998 0.06 cfm /SF x 998 SF 180 CFM South - - 120 CFM Air Distribution Schedule Symbol Name Type Accessories Manufacturer & Model No. PERFORATED ADJUSTABLE 'Titus' PCS - AA 'A' SUPPLY AIR CEILING DIFF. PATTERN CONTROLLER 24" X 24" FACE SUPPLY AIR PERFORATED ADJUSTABLE 'Titus' PCS - AA CEILING DIFF. PATTERN CONTROLLER 24" X 12" FACE PERFORATED 'C' RETURN AIR CEILING GRILLE - " "" 'Titus' PAS - 24" X 24" 'D' INTAKE CEILING GRILLE - - -- 'Titus' 3 FL 'E' SUPPLY AIR CEILING LINEAR LINED PLENUM 'Titus' ML-37 2 SLOTS 'F' RETURN AIR CEILING LINEAR LINED PLENUM 'Titus' MLR-37 2 SLOTS DRAINABLE BLADES GREENHECK EHH -601D 'G' INTAKE WALL LOUVER ALUMINUM BIRD SCREEN (see Note 2 below) NOTES: 1. - Coordinate Color Finish with Interior Designer 2. - Miami -Dade N.O.A. # 10- 0921 -10 fiberglass plenum (R -6 min.) C ceiling flexible duct connection at top or the side of the plenum -opposed blade domper provide 1� /Z" insulation with vapor barrier on oil metal surfaces (R -6 min.) supply diffuser Typical Diffuser Installation Detail N.T.S. 0 corrosion resistant insect screen (only for toilet exhaust) Baked enamel over cold rolled steel or aluminum (Verify color with Architect) 3o Aluminum flashing ® Ductwork (refer to plans) ORound wall gasket (rectangular gasket for rectangular ductwork) Wall Cap Detail N.T.S. Contractor shall provide weatherproof sealant all around penetrations for a weathertight installation BROCKHOUSE BROCKI-IOUSE ASSOCIATES PA m ! 4:973 S. A'. 75th AVENUE .MIAMI, - FI-ORL DA 33155 395 666 2333 ■ FAX 666 2332 AR 10652 AA 0002456 BRUCE BROC:KILOUSE ARCMTECTURE ■ INTERIOR DESIGN PROJECT An Interior Renovation to the Medical Offices of: DR. SANDINO GONZALEZ 6150 Sunset Drive South Miami, Florida 33143 SEAL a A r, Ej INN OVATIVE ENGINEERING GROUP, INC. SUDHIR K. GUPTA P.E. # 29189 5532 N.W. 72 AVE. MIAMI, FLORIDA 33166 305 -888 -9626 SHEET TITLE HVAC SCHEDULES & DETAILS SHEET TITLE REFERENCE 12018- hvacdet.dgn ALL CONCEPTS, DESIGNS, ARRANGEMENTS, DRAWINGS AND SPECIFICATIONS ARE OWNED BY, AND ARE THE PROPERTY OF THIS OFFICE AND WERE CREATED,EVOLVED AND DEVELOPED FOR USE ON, AND IN CONJUNCTION WITH, THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED 10 ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF: EIROCKHOUSE ASSOCIATES, PA. REVISION DESIGNED BY B.A. DRAWN BY B.A. APPROVED BY S.G. DATE 7 -13 -12 SCALE AS NOTED PROJECT No. 12018 SHEET NO, M.3