Loading...
12-729-014+01-011 exist. slab A Section A - Typical Stairway Run 3/4" = I'- 0" Q 1 v v a� 41 concrete 6 wall 1%2" dia. mtl. handrail bracket style as er's specs.) .7Vi.r),r VI 4 4r1 Vl•I�G l (finish & style as per Owner's specs.) concrete wall i (wings 2" dia. mtl. handrail ovide support blocking for bracket (G.C. to verify exact attachment) RAILING NOTES: 1. Railing system shall withstand a minimum lateral force of 200 lbs. applied in any direction (as per section 1608.2 of the Florida Building Code 2001) or 50 lbs. per ft. along top rail. 2. Submit shop drawings for Architect's approval. Stair Railing Detail (Wall Mounted) N.T.S. -- -'� textur •ete fin Q underside of structural deck (2) 35/8" galy, steelrunner at top 2' -0" x 2' -0" lay in accoustical ceiling tile - Olympia Micro Climaplus Series (white) by u.s.g. corporation (or approved equal) w/ compatible metal grid system (white) - typical Sheetrock Brand gypsum panels, Firecode core - 35/8" 24 ga. steel studs 24" o.c. (panels screw att. joints fin - perimeter caulked) UL Design U419 provide horizontal catts not to exceed 4' -0" o.c. (typical all partitions) 35/8" (25 gage) steel studs a 16" o.c. (typ.) 35/8" (25 gage) steel base track w /1/2 dia. exp. bolts 0 24" o.c. — verify new base finish w/ Owner r— continuous fire caulking each side typical verify new floor finish w/ Owner Typical Drywall Partition 1 1/2" = 1'- 0" (1 hr. fire rated - UL design 0419) Blocking Note= Provide additional reinforcing in wall areas where millwork & cased good components are to be installed Detail M A L V IVr 111 V4\rV VaT 414V1 ceiling tile Olympia Micro Climaplus Series (white) by u.s.g. corporation (or approved equal) w/ compatible metal grid system (white) - typical underside of structural deck (2) 35/8° galet steel runner at top Q /ts ti7lI�iG4! VMItl 411 VIIV gypsum panels, Firecode core - 35/8" 24 ga. steel studs 24" o.c. (panels screw att. Joints fin - perimeter caulked) UL Design U419 Drywall Soffit Detail i 1 1/2" = 1'- 0" 2' -0" x 2' -O" lay in accousticol ceiling tile - Olympia Micro Climaplus Series (white) by u.s.g. corporation (or approved equal) w/ compatible metal grid system (white) - typical Sheetrock Brand gypsum panels, Firecode core - 3%" 24 ga. steel studs 24" o.c. (panels screw att, joints fin - perimeter caulked) UL Design U419 verify tile height in field 12" x 12" ceramic tile grid (color as per I.D.) or other non - absorvent material as per F.B.C. 2007 V2" DensShield Tile Backer Board (gray side facing interior) or approved equal (shall comply w /FBC Section 2509.2 moisture barrier requirements) motor layer on tile backer board continuous fire caulking each side typical 12" x 12" ceramic tile grid (color as per I,D.) or other non - obsorvent material as per F.B.C. 2007 Typical Bathroom Partition 1 1/2" = 1'- 0" (1 hr. fire rated - UL design U419) Blocking Note: Provide additional reinforcing in wall areas where millwork & cased good components are to be installed underside of structural deck 2' -0" x 2' -0" lay in accousticol ceiling tile - Olympia Micro Climaplus Series (white) by u.s.g. corporation (or approved equal) w/ compatible meta grid system (white) - typical IBROCKHOIJSE LROCKHOr.iSE ASSOCIATES PA 4973 S. W. 75th AVENUE NI AMT, FLORIDA 33155 30566623-",3 ■ FAX 6662332 AR 10682 AA 0002456 BRUCE 13ROCKHOUSE ARCHITECTURE ■ INTERIOR DESIGN PROJECT An Interior Renovation to the Medical Offices of: DR. SANDINO OONZALEZ 6150 Sunset Drive South Miami, Florida 33143 SEAL F �w /pia 1` •l SHEET TITLE ARCHITECTURAL SECTIONS & DETAILS SHEET TITLE REFERENCE 12018- partdet.dgn ALL CONCEPTS, DESIGNS, ARRANGEMENTS, DRAWINGS AND SPECIFICATIONS ARE OWNED BY, AND ARE THE PROPERTY OF THIS OFFICE AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON, AND IN CONJUNCTION WITH, THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF: Sheetrock Brand gypsum BROCKHOUSE ASSOCIATES, PA, panels, Firecode core - 35/8" REVISION 24 ga. steel studs 24" o.c. (panels screw ott. joints fin - pp.e imeter Q 8-14 -12 PERMIT REVISIONS caulked) UL Design U419. fi OP ,OkJ I H iAIU .i. 1 (FIRE) Iii 9i,i) fi I, B- 31 -12: ADDITIONAL. PERMIT �,1 y A2 REVISIONS. (FIRE) a V.j WA°i EK I Ali Px' rEN."KNIIN SAT �r� �r continuous fire caulking each side typical 1 Hour Fire Rated Partition 1 1/2"= 1'- 0" (1 hr. fire rated - UL design U419) DESIGNED BY B.A. DRAWN BY B.A. APPROVED BY S.G. DATE 7 -13 -12 SCALE AS NOTED PROJECT NO. 12018 SHEET NO. A.�