12-729-014+01-011
exist. slab
A
Section A - Typical Stairway Run
3/4" = I'- 0"
Q
1
v
v
a�
41 concrete
6 wall
1%2" dia. mtl.
handrail
bracket
style as
er's specs.)
.7Vi.r),r VI 4 4r1 Vl•I�G l
(finish & style as
per Owner's specs.)
concrete wall
i
(wings
2" dia. mtl.
handrail
ovide support blocking for bracket
(G.C. to verify exact attachment)
RAILING NOTES:
1. Railing system shall withstand a minimum lateral force of 200 lbs.
applied in any direction (as per section 1608.2 of the Florida Building
Code 2001) or 50 lbs. per ft. along top rail.
2. Submit shop drawings for Architect's approval.
Stair Railing Detail (Wall Mounted)
N.T.S.
-- -'� textur
•ete fin
Q
underside of
structural deck
(2) 35/8" galy,
steelrunner at top
2' -0" x 2' -0" lay in accoustical
ceiling tile - Olympia Micro Climaplus
Series (white) by u.s.g. corporation
(or approved equal) w/ compatible
metal grid system (white) - typical
Sheetrock Brand gypsum
panels, Firecode core - 35/8"
24 ga. steel studs 24" o.c. (panels
screw att. joints fin - perimeter
caulked) UL Design U419
provide horizontal catts not
to exceed 4' -0" o.c. (typical
all partitions)
35/8" (25 gage) steel studs
a 16" o.c. (typ.)
35/8" (25 gage) steel
base track w /1/2 dia.
exp. bolts 0 24" o.c.
— verify new base
finish w/ Owner
r— continuous fire
caulking each
side typical
verify new floor
finish w/ Owner
Typical Drywall Partition
1 1/2" = 1'- 0" (1 hr. fire rated - UL design 0419)
Blocking Note=
Provide additional reinforcing in wall areas where millwork &
cased good components are to be installed
Detail
M A L V IVr 111 V4\rV VaT 414V1
ceiling tile Olympia Micro Climaplus
Series (white) by u.s.g. corporation
(or approved equal) w/ compatible
metal grid system (white) - typical
underside of structural
deck
(2) 35/8° galet
steel runner at top
Q
/ts ti7lI�iG4! VMItl 411 VIIV gypsum
panels, Firecode core - 35/8"
24 ga. steel studs 24" o.c. (panels
screw att. Joints fin - perimeter
caulked) UL Design U419
Drywall Soffit Detail i
1 1/2" = 1'- 0"
2' -0" x 2' -O" lay in accousticol
ceiling tile - Olympia Micro Climaplus
Series (white) by u.s.g. corporation
(or approved equal) w/ compatible
metal grid system (white) - typical
Sheetrock Brand gypsum
panels, Firecode core - 3%"
24 ga. steel studs 24" o.c. (panels
screw att, joints fin - perimeter
caulked) UL Design U419
verify tile height
in field
12" x 12" ceramic tile grid
(color as per I.D.) or
other non - absorvent
material as per F.B.C. 2007
V2" DensShield Tile Backer
Board (gray side facing interior)
or approved equal (shall comply
w /FBC Section 2509.2 moisture
barrier requirements)
motor layer on tile backer board
continuous fire
caulking each
side typical
12" x 12" ceramic tile grid (color as
per I,D.) or other non - obsorvent
material as per F.B.C. 2007
Typical Bathroom Partition
1 1/2" = 1'- 0" (1 hr. fire rated - UL design U419)
Blocking Note:
Provide additional reinforcing in wall areas where millwork &
cased good components are to be installed
underside of structural
deck
2' -0" x 2' -0" lay in accousticol
ceiling tile - Olympia Micro Climaplus
Series (white) by u.s.g. corporation
(or approved equal) w/ compatible
meta grid system (white) - typical
IBROCKHOIJSE
LROCKHOr.iSE ASSOCIATES PA
4973 S. W. 75th AVENUE
NI AMT, FLORIDA 33155
30566623-",3 ■ FAX 6662332
AR 10682 AA 0002456
BRUCE 13ROCKHOUSE
ARCHITECTURE ■ INTERIOR DESIGN
PROJECT
An Interior Renovation to
the Medical Offices of:
DR. SANDINO
OONZALEZ
6150 Sunset Drive
South Miami, Florida 33143
SEAL
F
�w /pia 1` •l
SHEET TITLE
ARCHITECTURAL
SECTIONS & DETAILS
SHEET TITLE REFERENCE
12018- partdet.dgn
ALL CONCEPTS, DESIGNS, ARRANGEMENTS, DRAWINGS AND
SPECIFICATIONS ARE OWNED BY, AND ARE THE PROPERTY OF
THIS OFFICE AND WERE CREATED, EVOLVED AND DEVELOPED
FOR USE ON, AND IN CONJUNCTION WITH, THE SPECIFIED
PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS
OR PLANS SHALL BE USED BY OR DISCLOSED TO ANY PERSON,
FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER
WITHOUT THE WRITTEN PERMISSION OF:
Sheetrock Brand gypsum BROCKHOUSE ASSOCIATES, PA,
panels, Firecode core - 35/8" REVISION
24 ga. steel studs 24" o.c. (panels
screw ott. joints fin - pp.e imeter Q 8-14 -12 PERMIT REVISIONS
caulked) UL Design U419. fi OP ,OkJ I H iAIU .i. 1 (FIRE)
Iii 9i,i) fi I, B- 31 -12: ADDITIONAL. PERMIT
�,1 y
A2 REVISIONS. (FIRE)
a V.j
WA°i EK I Ali Px' rEN."KNIIN
SAT �r� �r
continuous fire
caulking each
side typical
1 Hour Fire Rated Partition
1 1/2"= 1'- 0" (1 hr. fire rated - UL design U419)
DESIGNED BY
B.A.
DRAWN BY
B.A.
APPROVED BY
S.G.
DATE
7 -13 -12
SCALE
AS NOTED
PROJECT NO.
12018
SHEET NO.
A.�