13-389-001a
3 Uj
i
IPROJECT # - --
SHEET III,
CAO I
I
■ 1
PRINT DATE:
IFeb 13. 2013
PERMIT SET: 02.13.13
DRAWING NAME
Card Access Plan
Dwg 1 of 1
=GEND
EXISTING CARD READER
NEW CARD READER
PROJE
61 Sunset Drive
So Miami, FL
3rr loor
PB05 LPBj CRN)
TREX CR05
ML05 ML
ML04MO (N) l
PB04 PBII CR04
I
I
,f I
I'
I
DOOR HARDWARE SCHEDULE
List of equipment:
Kantech two door controller: 604
Rechargeable Battery: 12 V 7 amp/hr01
Kantech Entera -Pass SP: Sftware02
CR HID card readers:
TREX Motion sensor door release: T- Rex -L02
ES Electric Strike Seco -Larm: SD -995C
ML MAG LOCK LOCKNETICS 390 -DSM MBS 62S
PB PUSH TO EXIT SECURITRON EE82
BUTTON WITH TIMER
SECURITY CONSULTANT
�II
GLANZ
TECHNOLOGIES, INC.
687 NE 124th Street
North Miami, Florida 33161
REQUEST TO EXIT
MOTION DETECTOR
NFPA 101 NOTES
cR NON— SECURE/ 60 in. (1525 Mm) of, the '.secured doors.
PUBLIC SIDE t
(4) The manual. release device specified in
TREx 7.2.1.6.2(3) sh,' Il be ,seedily; Accessible and clearly
0 SECURE SIDE identified by .a sign , th'at reads . Os follows.
SINGLE DOORS WITH ELECTRIC MORTIS LOCK PUSH TO EXIT
PUSH TO EXIT
BUTTON
MOUNTED ON
WALL
7.2.1.6.2 Access — Controlled Egress Doors. When
(5) When operated, the manual release device
permitted in Chapters 11 through 42, doors in
HOMERUN TO EQUIP ROOM FOR
the means of egress shall be permitted to be
OWER SUPPLY
equipped with an approved entrance and egress
lock - Independent of the access Control s stem
P y
access control system, provided that the following
DISCONNECT INTERFACE
criteria are met:
DROPPED
OL CEILING HT.
Unlocked for not less than 30 seconds.
TYPICAL
(1) A sensor shall be provided on the egress
(1)1 -C FROM CONTROLLER
side, arranged to detect an occupant approaching
doors that are arranged .`to unlock in
The direction of egress =upon detection of an
(6) Activation of the building fire — protective
approaching occupant or. loss of power to the
sensor. ;
TIPICAL CEILING HT
(2) Loss of power to 'the.. 'p:art of the access
control system that locks '....The, doors shall
.K WITH REQUEST
automatically unlock the. _doors '..in, the direction
XIT OPTION
Of egress.
�.ged� to unlock in the
(3) The doors shall- b'e arran
1/2-C
direction of egress >From -a- manual release
device Located 40; .in...to. 48 jn. (1015 mm
the doors shall remain unlocked Until the
To 1220mm) 'vertical Iv*1'abo,ve.'.the. floor and within
cR NON— SECURE/ 60 in. (1525 Mm) of, the '.secured doors.
PUBLIC SIDE t
(4) The manual. release device specified in
TREx 7.2.1.6.2(3) sh,' Il be ,seedily; Accessible and clearly
0 SECURE SIDE identified by .a sign , th'at reads . Os follows.
SINGLE DOORS WITH ELECTRIC MORTIS LOCK PUSH TO EXIT
PUSH TO EXIT
BUTTON
MOUNTED ON
WALL
uwnunn
ENGINEER � L/�
SEAL
(5) When operated, the manual release device
PULL TO ENTER
HOMERUN TO EQUIP ROOM FOR
shall result in direct Interruption of power to the
NO 49801 —{
STATE OF
ACCESS CONTROL-SYSTEM, POWER
SUPPLIES AND FIRE ALARM SYSTEM
lock - Independent of the access Control s stem
P y
STATE OF FLORIDA
DISCONNECT INTERFACE
electronics - and the doors shall remain
Unlocked for not less than 30 seconds.
JB
(1)1 -C FROM CONTROLLER
r:
DROPPED
(6) Activation of the building fire — protective
TIPICAL CEILING HT
signaling system, if Provided, shall automatically
unlock the doors In the Direction of egress and
1/2-C
REQUEST TO EXIT
the doors shall remain unlocked Until the
�Ex
MOTION DETECTOR
fire - protective signaling system has been
I-MLI
I ML I
manually
M101
M102
Reset.
PB
(7) The activation of manual fire alarm boxes
that activate the Building fire - protective signaling
FRONT -DOOR
system specified in 7.2.1.6.2(6) Shall not be
required to unlock the doors.
CONTACT
NON- SECURE/
(8) Activation of the building automatic sprinkler
M101
"PUBLIC" SIDE
or fire detection System, if provided, shall
®
M MM102
automatically unlock the doors in the
# ##
Direction of egress and the doors shall remain
The fire — signaling system
unlocked until protective
SECU R E S I DE
has been manually reset.
DOUBLE DOOR WITH MAGLOCK
---------------------------------
r—
MAGNETIC LOCK WITH CARD READER AT PUBLIC OR I
'SCOPE
OF
NON - SECURE SIDE TO TRAVERSE DOOR I
I
I
T -REX REQUEST TO EXIT MOTION DETECTOR ON
SECURE SIDE TO RELEASE MAGNETIC LOCK ON EXIT. I
I
SCOPE OF WORK INCLUDES (5) EXISTING ACCESS j
I
CONTROLLED DOORS TO REMAIN AND INTEGRATE I
PUSH TO EXIT BUTTON TO
LOCK(S) ON EXIT.
RELEASE MAGNETIC
(5) NEW ACCESS CONTROLLED DOORS — SHOWN
uwnunn
ENGINEER � L/�
SEAL
•
\ \ \ \ \ \U \UIIIIIt/lllq /I /p� �
STRq
�=
JAME T. A
NO 49801 —{
STATE OF
PR FESS NAL ENGINEER No.49801
=0 <-, Q'
0 R���.��`�
STATE OF FLORIDA
1'1/14_
A;/AII1111111Uc \.���
02.13.13
date•
CLIENT
ON PLAN — INTO THE EXISTING SYSTEM.
La _
REVISIONS
�r
.r
1
4
f ;x
t"