14-715-004REGULATORY REQUIREMENTS
A. FLORIDA BUILDING CODE 2010
PLUMBING — GENERAL NOTES:
1 • ALL EXISTING WORK NOT SHOWN ON THESE DRAWINGS
(UNLESS NOTED OTHERWISE) SHALL REMAIN AS IS.
2. THE CONTRACTOR SHALL KEEP A SET OF MARKED UP DRAWINGS
AS THE JOB PROGRESSES. NO MAJOR CHANGE SHALL BE MADE
TO PLUMBING DESIGN /ENGINEERING UNLESS IT HAS BEEN
COORDINATED DRAWN, AND SUBMITTED FOR APPROVAL TO
THE ARCHITECT.
3. CONTRACTOR SHALL COORDINATE WITH ALL
DISCIPLINES INVOLVED SO AS TO AVOID ANY PIPE
ROUTING PROBLEMS.
WARRANTY /GUARANTEE
THE CONTRACTOR SHALL WARRANTY /GUARANTEE AND MAINTAIN
A THE STABILITY OF WORK AND MATERIALS AND KEEP SAME IN
PERFECT REPAIR AND CONDITION OF THE PERIOD OF ONE YEAR.
DEFECTS OF ANY KIND DUE TO THE FAULTY WORK OR MATERIALS
B APPEARING DURING THE ABOVE MENTIONED PERIOD MUST BE
IMMEDIATELY MADE GOOD BY THE CONTRACTOR AT HIS OWN
EXPENSE TO THE ENTIRE SATISFACTION OF THE OWNER AND
ENGINEER. SUCH RECONSTRUCTION AND REPAIRS SHALL
INCLUDE DAMAGE TO THE FINISH OR FURNISHING OF THE
BUILDING RESULTING FROM THE ORIGINAL DEFECT OR REPAIR
THERETO.
PLUMBING SPECIFICATIONS
PLUMBING MATERIALS
PLUMBING BUILDING CODE AND ADA REQUIREMENTS.
PLUMBING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH SOUTH FLORIDA
PLUMBING BUILDING CODE AND ADA REQUIREMENTS.
WASTE AND VENT TO BE PVC SCHEDULE 40 ABOVE GROUND AND
PVC SCHEDULE 80 BELOW GRADE.
WATER: DOMESTIC COLD, HOT WATER PIPING SHALL BE TYPE "L" HARD
DRAWN COPPER WITH WROUGHT FITTINGS, WITH 95/5 LEAD FREE SOLDERED
JOINTS. TYPE "K" COPPER BELOW FLOOR SLAB. INSULATE HOT WATER
AND HOT WATER RECIRCULATION PIPING USING 1" THICK FIBERGLASS
INSULATION HAVING A FLAME SPREAD RATING OF 25 OR LESS AND A SMOKE
DEVELOPMENT OF 50 OR LESS IN ACCORDANCE WITH ASTM E -84, NPFA 225
AND UL 723. FOAMGLASS INSULATION SHALL BE USED WHERE PIPING
PENETRATES RATED WALLS.
TEST WATER AND WASTE PIPING AS PER LOCAL CODES.
PLUMBING FIXTURES: KOHLER, AMERICAN STANDARD, ELDER.
PLUMBING TRIM: CHICAGO, SPEAKMAN
STAINLESS STEEL SINK: ELKAY OR JUST
PLUMBING FIXTURES
PROVIDE PLUMBING FIXTURES, TRIM AND RELATED ITEMS SUCH AS
SUPPLIES, TRAPS, DRAINS, CLEANOUTS, WATER CLOSET SEATS AND
COVERS, FIXTURE SUPPORTS AND OTHER ACCESSORY ITEMS. COORDINATE
FIXTURE REQUIREMENTS BY REVIEWING ARCHITECTURAL AND EQUIPMENT
DRAWINGS. INSTALL FIXTURES IN ACCORDANCE WITH CONTRACT DRAWINGS
MATERIALS VALVES
1. BALL VALVES — 2" AND LESS:
A. DOMESTIC WATER: FIGURE T585 -70 OR S- 585 -70, 2— PIECE,
FULL PORT. 600 PSI, WOG, TFE SEATS.
B. PROVIDE BALL VALVES WITH LOCKING HANDLES.
C. PROVIDE EXTENDED LEVER FOR INSULATED SERVICE.
z �
EXAM
ROOM
SINK 101
OFFICE EXAM
ROOM
100
CL.
cL.
RECEPTION
AREA < CL.
EXAM EXAM
ROOM ROOM
l \\
SCALE: 1/4" = 1' -Oil
NEW WORK KEY NOTES
1 NEW SINK TO BE LOCATED IN THIS AREA, CONNECT NEW DOMESTIC
AND SANITARY PIPING TO EXISTING SANITARY AND DOMESTIC IN SAME
AREA FROM ADJACENT SINK.
OEXISTING SINK TO REMAIN.
NEW CONSTRUCTION LEGEND
SYMBOL
DESCRIPTION
SYMBOL
EXISTING TO REMAIN
— —
NEW COLD WATER
NEW CONSTRUCTION
NATURAL GAS LINE
�--�
CONNECT TO EXIST. AT THIS POINT
PLUMBING LEGEND
SYMBOL
DESCRIPTION
SYMBOL
DESCRIPTION
— —
NEW COLD WATER
—GAS—
NATURAL GAS LINE
— —
NEW HOT WATER
]
CAP ON LINE
C.W
UNDERGROUND
SANITARY WASTE PIPING
0
PIPE TURNED UP
V
VENT PIPING
0
PIPE TURNED DOWN
AA �B
TYPICAL SHOCKARRESTOR
NEW UNDERGROUND SEAMLESS
COPPER DOMESTIC COLD WATER
T
BALL VALVE
�—
NEW UNDERGROUND SEAMLESS
COPPER DOMESTIC HOT WATER
PLUMBING FIXTURE SCHEDULE
• A
FIXTURE
FITTING
DATE:
05 -23 -2014
SCALE:
AS SHOWN
IL
SYMBOL
•��� O/�
tD� �a
MOUNTED
C.W
H.W.
WASTE
REMARKS
�(L
MANUFACTURER
MODEL
TYPE
SIZE
MANUFACTURER
TYPE
SUPPLY
TRAP
FAUCET
CARRIER
SINK
JUST
S.S. SINK
JSL- 15X15 —A —GR
SINGLE COMP.
(S.S.) 18 GAUGE
12')(12")(9'
McGUIRE
GRID DRAIN
H -2165
#8912
CHICAGO FAUCET
X895 -317CP
NA
_
1/2
1/2'
1 1/2'
EMERGENCY EYE WASH
SELF— RIMMING
X151
1 1/2'P —TRAP
WRISTBLADE HANDLE
NEVIN LABS MODEL# 630
- Z
GUIROLA 8: ASSOCIATES P.A.
CONSULTING ENGINEERS
P.E. No 57468
David Guirola
41 Electrical Engineer
1150 NW 72nd AVE, S -451
MIAMI, FLORIDA 33126
IN P.H: (305) 513 -9665
CA 00009112 EMAIL: GUIRO 5@AOL.COM
KE 1' � PL AN ' Z
SCALE: N.T.S.
OF
Revisions:
Z\
16
0
Z�
en Ln
0 mi / ~"
M
Q
M
0
x o
Vl
z
►� 0
V
N
0
xz F
�+ : Ln
o�
,a
F O
Va
CF
C�
Q �
a
O c,d
DRAWN:
• A
CHECKED:
DC$N
DATE:
05 -23 -2014
SCALE:
AS SHOWN
IL
-
I--
•��� O/�
tD� �a
Z
w
JUL
�(L
A
PERMIT
SET
DRAWN:
• A
CHECKED:
DC$N
DATE:
05 -23 -2014
SCALE:
AS SHOWN
Sheet NO.
P -1
OF
1
JOB # 201416
c F .
• to
0 0. ;
• w
•
•
-
I--
•��� O/�
tD� �a
Z
Sheet NO.
P -1
OF
1
JOB # 201416