14-715-003NOTE: TYPICAL Z BAR HANG DUCTS ACCORDING AND WIRE DUCT TO SMACNA STANDARDS HANGING DETAIL SECURE WIRE TYPICAL HANGING STRAP AND SADDLE HANGING DETAIL 10'7 MAX. METHODS OF HANGING DUCTS DETAIL N.T.S. SELF FLASPINCz BASE INSECT SCREEN ATTACH DUCTWORK TO CAP 4 SEAL IR-100 F CAG°� DE T A OLD NOT TO SCALE 4" TOILET EXHAUST DUCT (SHEETMETAL) VIBRATION HANGER SPRING TYPE W /NEOPRENE ISOLATOR 3/8- THREADED RODS - 0 0 O WHITE CEILING NOTES: GRILLE 1.- PROVIDE BACKDRAFT DAMPER W/ BIRDSCREEN 2.- FLASH & SEAL WALL AND ROOF CAP CABINET CEILING FAN DETAIL N.T.S. FAN SCHEDULE TYPE/ SERVICE CFM TSP IN WG MOTOR DATA SEINES OR INC UNIT WEIGHT TAG MODEL NO WATTS AMP VOLTS -PH -HZ EF -1 SP -8150 EXHAUST 155 1.25 128 1.7 120 2.5 12.4 Z N� I.L �nn lL (L (L ! PERMIT SET GENERAL FAN NOTES: PROVIDE MOTOR STARTERS. DISDONNECTS AND ALL ASSOCIATED CONTROLS PROVIDE BACKDRAFT FOR ALL EXHAUST FANS . FIELD ADJUST OPENINGS WITH STRUCTURE. PROVIDE BIRDSCREEN ON OUTLETS, GENERAL NOTES: 1. ALL MECHANICAL SYSTEMS ARE TO BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE SECTIONS OF THE NFPA STANDARDS, ANSI STANDARDS, THE LOCAL BUILDING CODE, NOISE & HEIGHT ORDINANCES, PLANS AND SPECIFICATIONS. 2. ALL MATERIALS SHALL BE NEW AND ALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDANCE WITH APPLICABLE LOCAL CODES, PRODUCT APPROVAL, RULES AND ORDINANCES, ANY DAMAGED EQUIPMENT SHALL BE REPLACED OR RESTORED TO ORIGINAL CONDITION. 3. THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, ACCESS PANELS, CONTROL SYSTEMS, DEVICES, PERMITS AND SERVICES NECESSARY FOR FURNISHING AND INSTALLING A COMPLETE OPERABLE MECHANICAL SYSTEM. 4. ALL LOUVERS, GRILLES, PIPING, ETC. SHALL BE PAINTED TO MATCH SURROUNDING COLOR AND TEXTURES AS REQUIRED BY ARCHITECT. VERIFY COLOR AND TEXTURE WITH ARCHITECT. PAINT ALL EXPOSED MECHANICAL EQUIPMENT WITH BENJAMIN MOORE EPDXY ENAMEL 182. 5. ALL CUTTING, PATCHING, STRUCTURAL STEEL, WEATHER PROOFING, PAINTING, AND WALL OPENINGS SHALL BE BY THE GENERAL CONTRACTOR. 6. ALL OPENINGS IN BUILDING STRUCTURE, FOR DUCTWORK, PIPING, ETC. TO BE 1/2" LARGER (ON ALL SIDES) THEN THE OUTSIDE DIMENSIONS. FILL VOIDS WITH FIRE RETARDANT SILICONE FOAM (I.E. CHASE -FOAM CTC PR -855 BY CHASE TECHNOLOGY CORP.). 7. SHOP DRAWINGS: CONTRACTORS SHALL SUBMIT FOR APPROVAL, WITHIN 30 DAYS AFTER SIGNING CONTRACT, A MINIMUM OF FIVE COPIES OF FULLY DESCRIPTIVE LITERATURE, INCLUDING BUT NOT LIMITED TO: AIR CONDITIONING UNITS, FANS AND AIR OUTLETS. NO WORK SHALL PROCEED WITHOUT APPROVAL OF THESE SUBMITTALS. 8. PROVIDE FLEXIBLE DUCT CONNECTORS, RATED AS REQUIRED, TO ALL FANS, A/C UNITS, OR MECHANICAL EQUIPMENT. 9. PROVIDE MAINTENANCE AND OPERATION MANUAL ON ALL MECHANICAL EQUIPMENT OR SYSTEMS. PROVIDE 5 SETS OF SUBMITTALS ON ALL HVAC EQUIPMENT. SUBMITTALS SHALL HAVE A SUMMARY SHEET SHOWING ALL SCHEDULED INFORMATION. 10. HVAC CONTRACTOR WILL WARRANTY ALL MECHANICAL SYSTEMS, DUCTWORK, THERMOSTATS, AND ALL OTHER EQUIPMENT,PARTS AND LABOR UNDER THESE DRAWINGS AND SPECIFICATIONS FOR A PERIOD OF ONE (1) YEAR AFTER C.O. OF BUILDING. ANY REPAIRS REQUIRING SYSTEM SHUT DOWN WILL BE DONE DURING NON OPERATIONAL PERIODS. HVAC CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES PRIOR TO BIDDING AND PURCHASING ANY EQUIPMENT. 11. AIR QUALITY SHOULD BE TESTED BEFORE OCCUPANCY AND SHOULD BE INSTRUMENTED AND MONITORED THEREAFTER, OR AT LEAST AT REGULAR INTERVALS 12. GENERAL CONTRACTOR TO PROVIDE FINAL TEST AND BALANCE PER NEW DESIGN LAYOUT. MECHANICAL EQUIPMENT NOTES: 1. ALL MECHANICAL EQUIPMENT SHALL BE ARI & U.L. LISTED WHERE APPLICABLE AND RATED FOR THE REQUIRED SERVICE, PRESSURES, TEMPERATURES, AND SHALL BE PROVIDED WITH ALL NECESSARY TRANSFORMERS, SEALS, VALVES, CONNECTIONS, ETC. TO FUNCTION PROPERLY. 2. PROVIDE VIBRATION ISOLATORS ON ALL MECHANICAL EQUIPMENT AS CALLED FOR IN THE SPECIFICATIONS. IF NOT SPECIFIED, AS RECOMMENDED BY MANUFACTURER FOR QUIET OPERATION (WITH 99% ISOLATION EFFICIENCY). 3. INDEPENDENT CONTRACTOR SHALL TEST AND BALANCE ALL MECHANICAL EQUIPMENT AIR DEVICES, EXTRACTORS, DAMPERS, AHU'S & FAN RATES, ETC. TO PROVIDE THE DESIGN QUANTITIES AS SHOWN ON THE PLANS OR SCHEDULES. PROVIDE T &B REPORT IN ACCORDANCE WITH THE AIR BALANCE COUNCIL STANDARDS, SIGNED AND SEALED BY A REGISTERED FLORIDA ENGINEER. PROVIDE FINAL BALANCING FOR ALL SYSTEMS TO SATISFACTION OF OWNER AND ENGINEER. T &B CONTRACTOR SHALL VISIT JOB SITE DURING CONSTRUCTION TO ENSURE THAT ALL DUCTS, DAMPERS, ETC. ARE INSTALLED FOR PROPER AND QUIET AIR DELIVERY. 4. THERMOSTAT LOCATION SHALL BE APPROVED BY OWNER AND ENGINEER BEFORE INSTALLATION. 5. ALL INSULATION WILL HAVE FIRE /SMOKE RATING LESS THAN 25/50. 6. FILTERS SHALL BE IN PLACE DURING CONSTRUCTION. PROVIDE A NEW SET PRIOR TO TEST AND BALANCE AND A FINAL SET AT THE END OF ONE YEAR SERVICE PERIOD. AIR DISTRIBUTION DUCTWORK NOTES 1. REFER TO ARCHITECTURAL PLANS FOR CEILING TYPE. 2. PROVIDE OFF WHITE FINISH (SUBJECT TO ARCHITECT'S APPROVAL). 3. ALL DUCTWORK WHERE ALLOWED BY LOCAL CODES AND AND CEILING RATING SHALL BE 1" LOW PRESSURE DUCT, SEAL CLASS "C" AND AS FOLLOWS: A. S/A & R/A - 1 -1/2" THICK FIBERGLASS DUCT BOARD WITH VAPOR BARRIER (R -6 MIN.) B. EXHAUST AIR DUCTWORK - GALVANIZED SHEETMETAL B. OUTSIDE AIR DUCTWORK - INSULATED GALVANIZED SHEETMETAL 4. ALL DUCTWORK AND DIFFUSERS SHALL BE RATED FOR THE USE, PRESSURE AND TEMPERATURE SPECIFIED AND AS REQUIRED BY THE CEILING SYSTEM RATING. 5. ALL DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH "SMACNA" STANDARDS AND LOCAL BUILDING CODES. 6. ALL DUCT SIZES ARE CLEAR INSIDE DIMENSIONS. 7. SEAL ALL DUCTS, JOINTS AND SEAMS IN AN APPROVED MANNER AND INSURE AGAINST LEAKAGE. 8. PROVIDE ACCESS DOORS AS REQUIRED FOR ALL MECHANICAL EQUIPMENT TO SERVICE AND VISUALLY CHECK ROTATION OF FANS AND MOTORS, POSITION OF DAMPERS, REPLACE FIRE DAMPER LINKS, ADJUST OR REPLACE CONTROLS, ETC. 9. PROVIDE VANED ELBOWS IN ALL CASES, SPUTTER DAMPERS WHERE INDICATED ON DRAWINGS AND VOLUME CONTROL DAMPERS IN ALL BRANCH DUCTS OR DIFFUSER CONNECTIONS. 10. TERMINAL AIR DISTRIBUTION DEVICES SHALL BE AS FOLLOWS: CEILING DIFFUSER: EQUIV. TO TITUS MODEL TDC -AA WALL DIFFUSER: EQUIV. TO TITUS MODEL 300 FL RETURN REGISTER: EQUIV. TO TITUS MODEL 350 FL Q-0 PARTIAL ROOF LOO PLAN MECHANIC74L z SCALE: 3/32" : V - V 70 ROOF AREA KEY NOTES: I LOCATION OF NEW EXHAUST T114ROUraFF1 ROOF, GEC, TO FIELD COORDINATE EXACT LOCATION WITH OmLm u SCALE: 114" : 1' -O" LEGEND ® NEW SUPPLY DIFFUSER ® NEW RETURN AIR GRILLE F EXHAUST FAN -� MANUAL VOLUME DAMPER O PROVIDE PROGRAMABLE T -STAT. 8 REMOTE SMOKE TEST /RESET STATION �- DUCT TRANSITION NEW RE - RELOCATE EXISTING SD - SMOKE DAMPER NEW FLEXIBLE DUCT, U.L. CLASS 1 (R -6) NEW DUCT WITH R =4.2 INSULATION. FIRE DAMPER SD DUCT SMOKE DETECTOR (WITH AUDIBLE AND VISIBLE CAPABILITY) CONNECT TO EXISTING AT THIS POINT z All -t GENERAL KEY NOTES: Oj EXISTING RETURN GRILL TO BE REMOVED FROM THIS AREA AS REQUIRED. OEXISTING SUPPLY AND RETURN GRILLS TO REMAIN. O6' EXHAUST SHEET METAL DUCT UP THRU 31;0 FLOOR TO ROOF. PROVIDED ROOF CAP WITH INSECT SCREIM ORELOCATE EXISTING 8UF'PLY GRILL TO NEW LOCATION AS SHOWN. EXTEND DUCTWORK AS REQUIRED. GENERAL NOTE: CONTRACTOR TO COORDNATE DUCTWORK LAYOUT WITH EXISTING ELECTRICAL CONDUITS, ETC. REROUTE EXISTNG DUCTWORK AS REQUIRED. NOTIFY OWNER ARCHITECT AND ENGINEER OF ANY CONFLICT WITH EXISTING CONDITIONS TO PROVIDE SOLUTIONS. GUIROLA & ASSOCIATES P.A. CONSULTING ENGINEERS P.E. No 57468 David Guirola Electrical Engineer 1150 NW 72nd AVE, 5-451 MIAMI, FLORIDA 33128 P.H: (305) 5139885 CA 00009112 EMAIL: GUIRO 5QAOL.COM KEY PLAN SCALE- N.T.S. Revisions: __ A A A 0 0 Q M 0 x N z 0 VO° LL3LO 30 41 Nv o� a �6 = E~ - a m O �x C 4-J Q Va -F&J d Q S O (� $ !.L O _j U I Vl _U ILL Z N� I.L �nn lL (L (L ! PERMIT SET DRAWN: JIM CHECKED: D(35N DATE: 08 -23 -2014 SCALE: AS SHOWN SEAL 1 Sheet No. M -1 OF 1 JOB # 2+01416