14-715-003NOTE: TYPICAL Z BAR
HANG DUCTS ACCORDING AND WIRE DUCT
TO SMACNA STANDARDS HANGING DETAIL
SECURE WIRE
TYPICAL HANGING
STRAP AND SADDLE
HANGING DETAIL
10'7 MAX.
METHODS OF HANGING
DUCTS DETAIL
N.T.S.
SELF FLASPINCz
BASE
INSECT SCREEN
ATTACH DUCTWORK
TO CAP 4 SEAL
IR-100 F CAG°� DE T A OLD
NOT TO SCALE
4" TOILET EXHAUST DUCT
(SHEETMETAL)
VIBRATION HANGER SPRING TYPE
W /NEOPRENE ISOLATOR
3/8- THREADED
RODS -
0
0
O
WHITE
CEILING
NOTES: GRILLE
1.- PROVIDE BACKDRAFT DAMPER W/ BIRDSCREEN
2.- FLASH & SEAL WALL AND ROOF CAP
CABINET CEILING
FAN DETAIL
N.T.S.
FAN SCHEDULE
TYPE/
SERVICE
CFM
TSP
IN WG
MOTOR DATA
SEINES
OR INC
UNIT
WEIGHT
TAG
MODEL NO
WATTS
AMP
VOLTS -PH -HZ
EF -1
SP -8150
EXHAUST
155
1.25
128
1.7
120
2.5
12.4
Z
N�
I.L
�nn
lL
(L
(L
!
PERMIT
SET
GENERAL FAN NOTES:
PROVIDE MOTOR STARTERS. DISDONNECTS AND ALL ASSOCIATED CONTROLS
PROVIDE BACKDRAFT FOR ALL EXHAUST FANS .
FIELD ADJUST OPENINGS WITH STRUCTURE.
PROVIDE BIRDSCREEN ON OUTLETS,
GENERAL NOTES:
1. ALL MECHANICAL SYSTEMS ARE TO BE INSTALLED IN ACCORDANCE WITH ALL
APPLICABLE SECTIONS OF THE NFPA STANDARDS, ANSI STANDARDS, THE LOCAL
BUILDING CODE, NOISE & HEIGHT ORDINANCES, PLANS AND SPECIFICATIONS.
2. ALL MATERIALS SHALL BE NEW AND ALL WORKMANSHIP AND MATERIALS SHALL BE
IN STRICT ACCORDANCE WITH APPLICABLE LOCAL CODES, PRODUCT APPROVAL,
RULES AND ORDINANCES, ANY DAMAGED EQUIPMENT SHALL BE REPLACED OR
RESTORED TO ORIGINAL CONDITION.
3. THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, ACCESS
PANELS, CONTROL SYSTEMS, DEVICES, PERMITS AND SERVICES NECESSARY FOR
FURNISHING AND INSTALLING A COMPLETE OPERABLE MECHANICAL SYSTEM.
4. ALL LOUVERS, GRILLES, PIPING, ETC. SHALL BE PAINTED TO MATCH
SURROUNDING COLOR AND TEXTURES AS REQUIRED BY ARCHITECT. VERIFY COLOR
AND TEXTURE WITH ARCHITECT. PAINT ALL EXPOSED MECHANICAL EQUIPMENT
WITH BENJAMIN MOORE EPDXY ENAMEL 182.
5. ALL CUTTING, PATCHING, STRUCTURAL STEEL, WEATHER PROOFING, PAINTING,
AND WALL OPENINGS SHALL BE BY THE GENERAL CONTRACTOR.
6. ALL OPENINGS IN BUILDING STRUCTURE, FOR DUCTWORK, PIPING, ETC. TO BE
1/2" LARGER (ON ALL SIDES) THEN THE OUTSIDE DIMENSIONS. FILL VOIDS
WITH FIRE RETARDANT SILICONE FOAM (I.E. CHASE -FOAM CTC PR -855 BY CHASE
TECHNOLOGY CORP.).
7. SHOP DRAWINGS: CONTRACTORS SHALL SUBMIT FOR APPROVAL, WITHIN 30 DAYS
AFTER SIGNING CONTRACT, A MINIMUM OF FIVE COPIES OF FULLY DESCRIPTIVE
LITERATURE, INCLUDING BUT NOT LIMITED TO: AIR CONDITIONING UNITS, FANS AND
AIR OUTLETS. NO WORK SHALL PROCEED WITHOUT APPROVAL OF THESE SUBMITTALS.
8. PROVIDE FLEXIBLE DUCT CONNECTORS, RATED AS REQUIRED, TO ALL FANS, A/C
UNITS, OR MECHANICAL EQUIPMENT.
9. PROVIDE MAINTENANCE AND OPERATION MANUAL ON ALL MECHANICAL EQUIPMENT
OR SYSTEMS. PROVIDE 5 SETS OF SUBMITTALS ON ALL HVAC EQUIPMENT.
SUBMITTALS SHALL HAVE A SUMMARY SHEET SHOWING ALL SCHEDULED
INFORMATION.
10. HVAC CONTRACTOR WILL WARRANTY ALL MECHANICAL SYSTEMS, DUCTWORK,
THERMOSTATS, AND ALL OTHER EQUIPMENT,PARTS AND LABOR UNDER THESE
DRAWINGS AND SPECIFICATIONS FOR A PERIOD OF ONE (1) YEAR AFTER C.O. OF
BUILDING. ANY REPAIRS REQUIRING SYSTEM SHUT DOWN WILL BE DONE DURING
NON OPERATIONAL PERIODS. HVAC CONTRACTOR SHALL COORDINATE WITH ALL
OTHER TRADES PRIOR TO BIDDING AND PURCHASING ANY EQUIPMENT.
11. AIR QUALITY SHOULD BE TESTED BEFORE OCCUPANCY AND SHOULD BE INSTRUMENTED
AND MONITORED THEREAFTER, OR AT LEAST AT REGULAR INTERVALS
12. GENERAL CONTRACTOR TO PROVIDE FINAL TEST AND BALANCE PER NEW DESIGN LAYOUT.
MECHANICAL EQUIPMENT NOTES:
1. ALL MECHANICAL EQUIPMENT SHALL BE ARI & U.L. LISTED WHERE APPLICABLE
AND RATED FOR THE REQUIRED SERVICE, PRESSURES, TEMPERATURES, AND SHALL
BE PROVIDED WITH ALL NECESSARY TRANSFORMERS, SEALS, VALVES,
CONNECTIONS, ETC. TO FUNCTION PROPERLY.
2. PROVIDE VIBRATION ISOLATORS ON ALL MECHANICAL EQUIPMENT AS CALLED FOR
IN THE SPECIFICATIONS. IF NOT SPECIFIED, AS RECOMMENDED BY
MANUFACTURER FOR QUIET OPERATION (WITH 99% ISOLATION EFFICIENCY).
3. INDEPENDENT CONTRACTOR SHALL TEST AND BALANCE ALL MECHANICAL EQUIPMENT
AIR DEVICES, EXTRACTORS, DAMPERS, AHU'S & FAN RATES, ETC. TO PROVIDE
THE DESIGN QUANTITIES AS SHOWN ON THE PLANS OR SCHEDULES. PROVIDE T &B
REPORT IN ACCORDANCE WITH THE AIR BALANCE COUNCIL STANDARDS, SIGNED
AND SEALED BY A REGISTERED FLORIDA ENGINEER. PROVIDE FINAL BALANCING
FOR ALL SYSTEMS TO SATISFACTION OF OWNER AND ENGINEER. T &B CONTRACTOR
SHALL VISIT JOB SITE DURING CONSTRUCTION TO ENSURE THAT ALL DUCTS,
DAMPERS, ETC. ARE INSTALLED FOR PROPER AND QUIET AIR DELIVERY.
4. THERMOSTAT LOCATION SHALL BE APPROVED BY OWNER AND ENGINEER BEFORE
INSTALLATION.
5. ALL INSULATION WILL HAVE FIRE /SMOKE RATING LESS THAN 25/50.
6. FILTERS SHALL BE IN PLACE DURING CONSTRUCTION. PROVIDE A NEW SET
PRIOR TO TEST AND BALANCE AND A FINAL SET AT THE END OF ONE YEAR
SERVICE PERIOD.
AIR DISTRIBUTION DUCTWORK NOTES
1. REFER TO ARCHITECTURAL PLANS FOR CEILING TYPE.
2. PROVIDE OFF WHITE FINISH (SUBJECT TO ARCHITECT'S APPROVAL).
3. ALL DUCTWORK WHERE ALLOWED BY LOCAL CODES AND AND CEILING RATING SHALL
BE 1" LOW PRESSURE DUCT, SEAL CLASS "C" AND AS FOLLOWS:
A. S/A & R/A - 1 -1/2" THICK FIBERGLASS DUCT BOARD WITH VAPOR BARRIER (R -6 MIN.)
B. EXHAUST AIR DUCTWORK - GALVANIZED SHEETMETAL
B. OUTSIDE AIR DUCTWORK - INSULATED GALVANIZED SHEETMETAL
4. ALL DUCTWORK AND DIFFUSERS SHALL BE RATED FOR THE USE, PRESSURE AND
TEMPERATURE SPECIFIED AND AS REQUIRED BY THE CEILING SYSTEM RATING.
5. ALL DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH
"SMACNA" STANDARDS AND LOCAL BUILDING CODES.
6. ALL DUCT SIZES ARE CLEAR INSIDE DIMENSIONS.
7. SEAL ALL DUCTS, JOINTS AND SEAMS IN AN APPROVED MANNER AND INSURE
AGAINST LEAKAGE.
8. PROVIDE ACCESS DOORS AS REQUIRED FOR ALL MECHANICAL EQUIPMENT TO
SERVICE AND VISUALLY CHECK ROTATION OF FANS AND MOTORS, POSITION OF
DAMPERS, REPLACE FIRE DAMPER LINKS, ADJUST OR REPLACE CONTROLS, ETC.
9. PROVIDE VANED ELBOWS IN ALL CASES, SPUTTER DAMPERS WHERE INDICATED
ON DRAWINGS AND VOLUME CONTROL DAMPERS IN ALL BRANCH DUCTS OR DIFFUSER
CONNECTIONS.
10. TERMINAL AIR DISTRIBUTION DEVICES SHALL BE AS FOLLOWS:
CEILING DIFFUSER: EQUIV. TO TITUS MODEL TDC -AA
WALL DIFFUSER: EQUIV. TO TITUS MODEL 300 FL
RETURN REGISTER: EQUIV. TO TITUS MODEL 350 FL
Q-0
PARTIAL ROOF LOO
PLAN MECHANIC74L z
SCALE: 3/32" : V - V 70
ROOF AREA KEY NOTES:
I LOCATION OF NEW EXHAUST T114ROUraFF1 ROOF, GEC,
TO FIELD COORDINATE EXACT LOCATION WITH
OmLm
u
SCALE: 114" : 1' -O"
LEGEND
® NEW SUPPLY DIFFUSER
® NEW RETURN AIR GRILLE
F EXHAUST FAN
-� MANUAL VOLUME DAMPER
O PROVIDE PROGRAMABLE T -STAT.
8 REMOTE SMOKE TEST /RESET STATION
�- DUCT TRANSITION
NEW
RE - RELOCATE EXISTING
SD - SMOKE DAMPER
NEW FLEXIBLE DUCT, U.L. CLASS 1 (R -6)
NEW DUCT WITH R =4.2 INSULATION.
FIRE DAMPER
SD DUCT SMOKE DETECTOR
(WITH AUDIBLE AND VISIBLE CAPABILITY)
CONNECT TO EXISTING AT THIS POINT
z
All
-t
GENERAL KEY NOTES:
Oj EXISTING RETURN GRILL TO BE REMOVED FROM
THIS AREA AS REQUIRED.
OEXISTING SUPPLY AND RETURN GRILLS TO REMAIN.
O6' EXHAUST SHEET METAL DUCT UP THRU 31;0
FLOOR TO ROOF. PROVIDED ROOF CAP WITH
INSECT SCREIM
ORELOCATE EXISTING 8UF'PLY GRILL TO NEW
LOCATION AS SHOWN. EXTEND DUCTWORK AS
REQUIRED.
GENERAL NOTE:
CONTRACTOR TO COORDNATE DUCTWORK LAYOUT WITH EXISTING
ELECTRICAL CONDUITS, ETC. REROUTE EXISTNG DUCTWORK AS
REQUIRED. NOTIFY OWNER ARCHITECT AND ENGINEER OF ANY
CONFLICT WITH EXISTING CONDITIONS TO PROVIDE SOLUTIONS.
GUIROLA & ASSOCIATES P.A.
CONSULTING ENGINEERS
P.E. No 57468
David Guirola
Electrical Engineer
1150 NW 72nd AVE, 5-451
MIAMI, FLORIDA 33128
P.H: (305) 5139885
CA 00009112 EMAIL: GUIRO 5QAOL.COM
KEY PLAN
SCALE- N.T.S.
Revisions:
__ A
A
A
0
0
Q M
0
x
N
z
0
VO°
LL3LO
30
41 Nv
o�
a
�6
= E~
- a
m
O
�x
C
4-J
Q Va
-F&J d
Q
S
O (� $
!.L
O
_j
U
I
Vl
_U
ILL
Z
N�
I.L
�nn
lL
(L
(L
!
PERMIT
SET
DRAWN: JIM
CHECKED: D(35N
DATE: 08 -23 -2014
SCALE: AS SHOWN
SEAL
1
Sheet No.
M -1
OF
1
JOB # 2+01416