09-305-015ME
GENERAL PLUMBING NOTES
FIXTURE
CONNECTION
I-
ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE FLORIDA
II-
ALL AUTOMATIC ELECTRIC WATER HEATERS SHALL MEET THE
WASTE
BUILDING CODE AND WITH ALL APPLICABLE REGULATIONS.
H.W.
STANDARDS OF THE LATEST ENERGY EFFICIENCY CODE.
2-
CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH ALL
12-
ALL HORIZONTAL SANITARY PIPING SHALL SLOPE AT 1/8" PER
1/2"
CONSTRUCTION DOCUMENTS INCLUDING ARCHITECTURAL,
FLOOR DRAIN(EXISTING)
FOOT MINIMUM FOR 3" AND LARGER AND AT 1/4" SLOPE FOR 2
LAVATORY
ELECTRICAL, HVAC, AND STRUCTURAL DISCIPLINES, PRIOR TO
1 1/4"
1/2" PIPES AND SMALLER.
1/2"
BIDDING. THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC,
SK
I SINK
AIR ADMITTANCE VALVE
NOT NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF
13-
ALL PIPES TO DISCHARGE MINIMUM 12" FROM STRUCTURE.
DRINKING FOUNTAIN(NEW)
THE MINOR ITEMS. ADJUSTMENTS IN THE PLUMBING SYSTEM TO
WHIRLPOOL PEDICURE SPA
2'
1/2"
ACCOMMODATE OTHER DISCIPLINES SHOULD BE EXPECTED, AND
14-
ALL OUTDOORS FLOOR CLEAN OUTS SHALL BE TERMINATED UP
MINIMUM SIZE OF ALL
ALL TRAPS SHALL BE
SHALL NOT REPRESENT ADDITIONAL COSTS TO OWNER.
TO GRADE AND SHALL BE MARKED.
3-
CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE, FEES,
15-
PROVIDE WALL CLEANOUTS AT THE BASE OF, EVERY STACK.
PERMITS, AND TAXES OF WHATEVER NATURE SHALL APPLY TO
Ih-
MATERIALS
THIS WORK. HE SHALL ALSO PAY ALL THE INSPECTION FEES
AS MAY REQUIRED BY LAW OR ORDINANCE AND SHALL KEEP
a_
COLD WATER PIPING DOWNSTREAM OF WATER METER SHALL BE
THE OWNER HARMLESS FROM ANY DAMAGE AND EXPENSE
TYPE "L" COOPER BELOW GROUND AND TYPE "M" COOPER
ARISING FROM ANY VIOLATION OF LAWS, RULES OR
ABOVE GROUND.
4-
8URN 9il SHALL COORDINATE EXACT LOCATION OF ALL
b-
COLD WATER PIPES INSIDE OF SLAB SHALL BE TYPE "K" SOFT
PLUMBING SYSTEM PIPING BEFORE STARTING ANY WORK. NOTIFY
COOPER. INSTALL INSIDE POLYETHYLENE CONDUIT. NO JOINS
ARCHITECT /ENGINEER OF ANY DEVIATIONS FROM DESIGN
PERMITTED INSIDE SLAB.
DRAWINGS.
c-
SANITARY WASTE AND VENT, AND STORM LINES INSIDE BUILDING
5-
THE COMPLETED INSTALLATION SHALL BE FULLY GUARANTEED
SHALL BE PVC SCHEDULE 40.
AGAINST DEFECTIVE MATERIALS AND /OR IMPROPER
d-
CONDENSATE DRAIN LINES SHALL BE SCHEDULE 40, PVC PIPE
WORKMANSHIP FOR A MINIMUM OF ONE YEAR FOR MATERIAL
AND FITTINGS.
AND LABOR.
6-
CONTRACTOR SHALL FURNISH THE ENGINEER WITH SHOP
17-
ALL PIPE THAT PASSES UNDER FOOTING OR THROUGH A
DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE FOR APPROVAL.
FOUNDATION WALL SHALL BE PROTECTED BY SLEEVE PIPE
I-
CONTRACTOR SHALL PROVIDE ALL NECESSARY LABOR AND
(TWO PIPES SIZES GREATER) AS PER PLUMBING F.B.C. 305.5
MATERIALS FOR A COMPLETE JOB, EVERYTHING CONNECTED
READY FOR USE.
18-
PLUMBING CONTRACTOR SHALL PROVIDE AIR CONDITIONING
CONDENSATE DRAIN AND TRAP. SEE AIR CONDITIONING PLANS
8-
PLUMBING CONTRACTOR SHALL PRESSURE TEST ALL PIPING
FOR LOCATION OF UNITS AND DRAINS.
AS REOUIRED BY CE. TEST SHALL BE WITNESSED AND
OD
APPROVED BY PROPER AUTHORITIES.
19-
ALL CEILING PENETRATIONS, JOINTS, t CRACKS SHALL BE
CAULKED, GASKETED, WEATHER STRIPPED OR OTHERWISE
9-
CONTRACTOR SHALL KEEP ACCURATE AS -BUILT DRAWINGS ON
SEALED TO AVOID ADDITIONAL CONDITIONED AIR TO GO INTO
THE FIELD AND PROVIDE THEM TO OWNER ONCE JOB IS
ATTIC SPACE.
COMPLETE.
IPA-
FIXTURES SHALL BE AS SELECTED BY OWNER AND SHALL BE
FURNISHED AND INSTALLED BY THIS CONTRACTOR. FIXTURES
SHALL BE COMPLETE WITH DRAINS, TRAPS, SUPPLIES AND ANY
OTHER ACCESSORY REQUIRED. FIXTURES AND FAUCETS SHALL
COMPLY WITH THE F.B.C. WATER SAVING STANDARDS.
WATER HEATER SPECS:
IN COMPLIANCE W/ F.B.C.
SHALL BE "TITAN —SCR2"
MODEL N120 ELECTRONIC
TANKLESS WATER HEATER
OR EQUAL
DIMENSIONS: 7"Wx10 "Hx2 3/4 "D
WEIGHT: 8 POUNDS
ENERGY EFF. : MIN. 97%
NO R.V.D. OR OVER FLOW
REQUIRED AS PER
MANUFACTURER SPECS.
NOTE: INSTALL WATER HEATER
8' ABOVE FINISH FLOOR.
INSTANT UJATEfR
HEATEFR IDETAIL
NTS
WATER PIPING SIZE
O
FIXTURE
CONNECTION
SCHEDULE
SYMBOL
FIXTURE TYPE
®
WASTE
C.W.
H.W.
DESCRIPTION
WC
WATER CLOSET
HOT WATER
3"
1/2"
—
FLOOR DRAIN(EXISTING)
LAV
LAVATORY
TYP.
1 1/4"
1/2"
1/2"
W.S.F.U.
SK
I SINK
AIR ADMITTANCE VALVE
1 1/2"
1/2"
1/2'
DRINKING FOUNTAIN(NEW)
WPS
WHIRLPOOL PEDICURE SPA
2'
1/2"
1/2"
WALL DRAIN
NOTES: -
-
MINIMUM SIZE OF ALL
ALL TRAPS SHALL BE
PLUMBING DRAIN LINE BELOW FLOOR 2 INCHES
CONSISTENT WITH FIXTURE OUTLET
WATER HEATER SPECS:
IN COMPLIANCE W/ F.B.C.
SHALL BE "TITAN —SCR2"
MODEL N120 ELECTRONIC
TANKLESS WATER HEATER
OR EQUAL
DIMENSIONS: 7"Wx10 "Hx2 3/4 "D
WEIGHT: 8 POUNDS
ENERGY EFF. : MIN. 97%
NO R.V.D. OR OVER FLOW
REQUIRED AS PER
MANUFACTURER SPECS.
NOTE: INSTALL WATER HEATER
8' ABOVE FINISH FLOOR.
INSTANT UJATEfR
HEATEFR IDETAIL
NTS
WATER PIPING SIZE
O
1/2- CW - HW
�2
1/2- CW
O3
3/4" CW - 1/2- HW
®
3/4" HW
@
3/4" CW - 3/4' HW
®
1" CW
EACH A.AV S//ALL SE
ACCESSSLE FOR SERY/CE OR
REPAIR AND LOCATED AS PER
fW PL UA/6VNG 917.5
COQ
O ,
LA
LAV
TAA W�K.LESS —
ELECTJ.U/H
(SEE DETAIL)
SYME30L
DESCRIPTION
SANITARY SEWER LINE
----- - - - - --
VENT LINE
I C.O.
CLEAN OUT
® F.C.O.
FLOOR CLEAN OUT
-
COLD WATER
ap
HOT WATER
-D4- S.O.V.
SHUT OFF VALVE
F.D
FLOOR DRAIN(EXISTING)
VTR
VENT THRU ROOF
TYP.
TYPICAL
F.U.
SANITARY FIXTURE -UNIT
W.S.F.U.
WATER - SUPPLY FIXTURE -UNIT
A.A.V.
AIR ADMITTANCE VALVE
SK
SINK(NEW)
DF
DRINKING FOUNTAIN(NEW)
WPS
WHIRLPOOL PEDICURE SPA(NEW)
n
NOTE:
ALL SANITARY LINES SHALL RUN AS FOLLOWS:
2 1/2" O kR SMALLER 0 114" SLOPE PER LPT. ;®
N
3" 0 AND LARGER • 1/8" SLOPE PER LPT.
TOP CABINETS
— CABINET
TYF, LOCATION OF Al2
, VALVE(A.A.V.)
NTS,
m
1/2" HW /CW 3/4" FROM WATER METER
NEXT TT WALL C
AROSS STREET FROM LOCATION
UPS
O
1/2" yHW/CW
NEXT TO WALL
a �ho
r
*A &Mel fiNK-f-FEWAIRM I WWI I il, W_ E;J WAA, Ll
2 "AA.V,
3" VTR
)I[,
BATH
2 "AA.V.
2 "AA.Y.
LAV
t
ell
• 4
tr ,J
0' LL
• W
w ~A
it z ,, -
4� 5 W Q
r 000
ryS -0 0
co
W > LL 0^0
.� . =
3 Q -i co ..
311 14,
ulc J®
2=AA.V. 8 S ::.
SMK ....... :.
... .......
CO
sjo
:.::.
:.....::::
.
1 I$
2'AAV.
LAY
2"
l2FU) M
®,IN
1/4 71=17_071
� � •..° y+t ap try ,r �• ��� Y
w)
LL
.. _.. ''� °+.• r t Tat',.
;L r
.:f
! t .
( a
t
II N
,
I
Z�
iii
a
z Lu
OZ F-�
a o oc cc :c
,4 1. z
=11 co X
a hda
0 ?5 A;
�aJ 0aU6
�WaJ
0M L1. =f
��—aim
UJUs Z� r
Z
rg two
■O
a. r
Revision
I(
I�
:vo
1
ca
o R. G
as
Chodst M.�
o
04/01/09
RroJ 08-40
Sheet'
Z
YO
z�
QO
tz
�o
�2
ap
OO CL
®
Zc
0
VE
*A &Mel fiNK-f-FEWAIRM I WWI I il, W_ E;J WAA, Ll
2 "AA.V,
3" VTR
)I[,
BATH
2 "AA.V.
2 "AA.Y.
LAV
t
ell
• 4
tr ,J
0' LL
• W
w ~A
it z ,, -
4� 5 W Q
r 000
ryS -0 0
co
W > LL 0^0
.� . =
3 Q -i co ..
311 14,
ulc J®
2=AA.V. 8 S ::.
SMK ....... :.
... .......
CO
sjo
:.::.
:.....::::
.
1 I$
2'AAV.
LAY
2"
l2FU) M
®,IN
1/4 71=17_071
� � •..° y+t ap try ,r �• ��� Y
w)
LL
.. _.. ''� °+.• r t Tat',.
;L r
.:f
! t .
( a
t
II N
,
I
Z�
iii
a
z Lu
OZ F-�
a o oc cc :c
,4 1. z
=11 co X
a hda
0 ?5 A;
�aJ 0aU6
�WaJ
0M L1. =f
��—aim
UJUs Z� r
Z
rg two
■O
a. r
Revision
I(
I�
:vo
1
ca
o R. G
as
Chodst M.�
o
04/01/09
RroJ 08-40
Sheet'