Loading...
09-305-014GENERAL PLUMBING NOTES I- ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE AND WITH ALL APPLICABLE REGULATIONS. 2- CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH ALL CONSTRUCTION DOCUMENTS INCLUDING ARCHITECTURAL, ELECTRICAL, HVAC, AND STRUCTURAL DISCIPLINES, PRIOR TO BIDDING. THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE MINOR ITEMS. ADJUSTMENTS IN THE PLUMBING SYSTEM TO ACCOMMODATE OTHER DISCIPLINES SHOULD BE EXPECTED, AND SHALL NOT REPRESENT ADDITIONAL COSTS TO OWNER. 3- CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE, FEES, PERMITS, AND TAXES OF WHATEVER NATURE SHALL APPLY TO THIS WORK. HE SHALL ALSO PAY ALL THE INSPECTION FEES AS MAY REQUIRED BY LAW OR ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF LAWS, RULES OR Q pp 4- G�IV R&IFOR SHALL COORDINATE EXACT LOCATION OF ALL PLUMBING SYSTEM PIPING BEFORE STARTING ANY WORK. NOTIFY ARCHITECT /ENGINEER OF ANY DEVIATIONS FROM DESIGN DRAWINGS. 5- THE COMPLETED INSTALLATION SHALL BE FULLY GUARANTEED AGAINST DEFECTIVE MATERIALS AND /OR IMPROPER WORKMANSHIP FOR A MINIMUM OF ONE YEAR FOR MATERIAL AND LABOR. 6- CONTRACTOR SHALL FURNISH THE ENGINEER WITH SHOP DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE FOR APPROVAL. 1- CONTRACTOR SHALL PROVIDE ALL NECESSARY LABOR AND MATERIALS FOR A COMPLETE JOB, EVERYTHING CONNECTED READY FOR USE. 8- PLUMBING CONTRACTOR SHALL PRESSURE TEST ALL PIPINCs AS REQUIRED BY CODE. TEST SHALL BE WITNESSED AND APPROVED BY PROPER AUTHORITIES. S- CONTRACTOR SHALL KEEP ACCURATE AS -BUILT DRAWINGS ON THE FIELD AND PROVIDE THEM TO OWNER ONCE JOB IS COMPLETE. 10- FIXTURES SHALL BE AS SELECTED BY OWNER AND SHALL BE FURNISHED AND INSTALLED BY THIS CONTRACTOR. FIXTURES SHALL BE COMPLETE WITH DRAINS, TRAPS, SUPPLIES AND ANY OTHER ACCESSORY REQUIRED. FIXTURES AND FAUCETS SHALL COMPLY WITH THE F.B.C. WATER SAVING STANDARDS. 11- ALL AUTOMATIC ELECTRIC WATER HEATERS SHALL MEET THE STANDARDS OF THE LATEST ENERGY EFFICIENCY CODE. 12- ALL HORIZONTAL SANITARY PIPING SHALL SLOPE AT 1/8" PER FOOT MINIMUM FOR 3" AND LARGER AND AT 1/4" SLOPE FOR 2 1/2" PIPES AND SMALLER. 13- ALL PIPES TO DISCHARGE MINIMUM 12" FROM STRUCTURE. 14- ALL OUTDOORS FLOOR CLEAN OUTS SHALL BE TERMINATED UP TO GRADE AND SHALL BE MARKED. 15- PROVIDE WALL CLEANOUTS AT THE BASE OF EVERY STACK. Ifa- MATERIALS d- COLD WATER PIPING DOWNSTREAM OF WATER METER SHALL BE TYPE "L" COOPER BELOW GROUND AND TYPE "M" COOPER ABOVE GROUND. b- COLD WATER PIPES INSIDE OF SLAB SHALL BE TYPE "K" SOFT COOPER. INSTALL INSIDE POLYETHYLENE CONDUI -. NO JOINS PERMITTED INSIDE SLAB. c- SANITARY WASTE AND VENT, AND STORM LINES INSIDE BUILDING SHALL BE PVC SCHEDULE 40. d- CONDENSATE DRAIN LINES SHALL BE SCHEDULE 40, PVC PIPE AND FITTINGS. 17- ALL PIPE THAT PASSES UNDER FOOTING OR THROUGH A FOUNDATION WALL SHALL BE PROTECTED BY SLEEVE PIPE (TWO PIPES SIZES GREATER) AS PER PLUMBING F.B.C. 305.5 18- PLUMBING CONTRACTOR SHALL PROVIDE AIR CONDITIONING CONDENSATE DRAIN AND TRAP. SEE AIR CONDITIONING PLANS FOR LOCATION OF UNITS AND DRAINS. 19- ALL CEILING PENETRATIONS, JOINTS, 4 CRACKS SHALL BE CAULKED, GASKETED, WEATHER STRIPPED OR OTHERWISE SEALED TO AVOID ADDITIONAL CONDITIONED AIR TO GO INTO ATTIC SPACE. WATER HEATER SPECS: IN COMPLIANCE W/ F.B.C. SHALL BE "TITAN —SCR2" MODEL N120 ELECTRONIC TANKLESS WATER HEATER OR EQUAL DIMENSIONS: 7"Wx10 "Hx2 3/4 "D WEIGHT: 8 POUNDS ENERGY EFF. : MIN. 97% ` NO R.V.D. OR OVER FLOW REQUIRED AS PER MANUFACTURER SPECS. NOTE: INSTALL WATER HEATER 8' ABOVE FINISH FLOOR. INSTANT UJATE F-,., HEATE F-.,, [DETAIL NTS WATER PIPING 51ZE O FIXTURE CONNECTION 5CHEDULE SYMBOL FIXTURE TYPE ® WASTE C.W. H.W. DESCRIPTION WC WATER CLOSET HOT WATER 3" 1/2- — FLOOR DRAIN(EXISTING) LAV LAVATORY TYP. 1 1/4" 1/2" 1/2" W.S.F.U. SK SINK AIR ADMITTANCE VALVE 1 1/2- 1/2- 1/2- DRINKING FOUNTAIN(NEW) WPS WHIRLPOOL PEDICURE SPA 2' 1/2" 1/2" WALL DRAIN NOTES: - - MINIMUM SIZE OF ALL ALL TRAPS SHALL BE PLUMBING DRAIN LINE BELOW FLOOR 2 INCHES CONSISTENT WITH FIXTURE OUTLET WATER HEATER SPECS: IN COMPLIANCE W/ F.B.C. SHALL BE "TITAN —SCR2" MODEL N120 ELECTRONIC TANKLESS WATER HEATER OR EQUAL DIMENSIONS: 7"Wx10 "Hx2 3/4 "D WEIGHT: 8 POUNDS ENERGY EFF. : MIN. 97% ` NO R.V.D. OR OVER FLOW REQUIRED AS PER MANUFACTURER SPECS. NOTE: INSTALL WATER HEATER 8' ABOVE FINISH FLOOR. INSTANT UJATE F-,., HEATE F-.,, [DETAIL NTS WATER PIPING 51ZE O EACH AA K SMZL BE ACCESS /BLF. FOR SEAWCE OR REPAIR AND LOC47ED AS PER fw PL UMB/NG 917.5 SCOPE OF WORK PLUMBING WORKS: NEW FOUR LAVATORIES, NEW TWO WHILPOOL PEDICURE SPA AND NEW INSTANT WATER HEATER SYMBOL 1/2- CW — HW Q 1/2- CW Q 3/4" CW — 1/2- HW ® 3/4' HW �5 3/4" CW — 3/4' HW Q in cW EACH AA K SMZL BE ACCESS /BLF. FOR SEAWCE OR REPAIR AND LOC47ED AS PER fw PL UMB/NG 917.5 SCOPE OF WORK PLUMBING WORKS: NEW FOUR LAVATORIES, NEW TWO WHILPOOL PEDICURE SPA AND NEW INSTANT WATER HEATER SYMBOL DE5CRIPTION SANITARY SEWER LINE ----- - - - - -- VENT LINE L C.O. CLEAN OUT ® F.C.O. FLOOR CLEAN OUT — COLD WATER HOT WATER —>q-- S.O.V. SHUT OFF VALVE % F.D FLOOR DRAIN(EXISTING) VTR VENT THRU ROOF TYP. TYPICAL F.U. SANITARY FIXTURE —UNIT W.S.F.U. WATER— SUPPLY FIXTURE —UNIT A.A.V. AIR ADMITTANCE VALVE SK SINK(NEW) DF DRINKING FOUNTAIN(NEW) WPS WHIRLPOOL PEDICURE SPA(NEW) NOTE: ALL SANITARY LINES SHALL RUN AS FOLLOWS- 2 1/2" O /7R SMALLER • 1/4" SLOPE PER LET. 3" 0 AND LARGER * 1/8" SLOPE PER LET. 4" MOV A6VW THE 110R/ZONT BRANCH ORA/N AS IER FBI;' PZIIV8 1NG 174 TOP CABINETS CABINET \_ 4" TOE REVEAL. TYf=. LOCATION OF AIR AlDt"11TTANCE VALVE(A_A_V_) NTS 0 1/2" 14W /CW - -- 1 RUN OUTSIDE ACROSS STREET FROM LOCATION NEXT TO WALL O M.S.D LAV ..._ 2 "AA.V. IWAI10 �1►C :���J�1:31►C�1�_1► 1/4 7Y=17_0" b ON I 1p = r • jx • �lpo co:c '04 a 42 C4 • , • • • uj on z a • • • Revision n � ws R. G. cirdo. , M. LOPEZ Dam a 04/01/09 Project # 08-401 Shft -t