11-556-0052.
4.
THIS DRAWING 15 ONLY TO ASSIST IN SHOWING
THE SCOPE OF DEMOLITION WORK AND 15 NOT
INTENDED TO INDICATE ALL DEMOLITION.
CONTRACTOR SHALL REMOVE ALL EXISTING
ITEMS AS REQUIRED TO COMPLETE THE JOB.
NOT ALL ITEMS TO BE DEMOLISHED ARE
SHOWN ON THE PLAN. CONTRACTOR SHALL BE
RESPONSIBLE FOR PERFORMING A WALK -THRU
OF THE PROJECT PRIOR TO SUBMITTING A BID
TO THE OWNER FOR IDENTIFYING POSSIBLE
CRITICAL ITEMS, NOT OR INCORRECTLY
ADDRESSED, WHICH REQUIRE REMOVAL/
RELOCATION,
PROVIDE SAFETY FEATURES DURING WORK AS
CALLED FOR IN SPECS, APPLICABLE CODES,
RULES AND REGULATIONS HAVING JURISDICTION
OF THE PROJECT.
CUT, REMOVE, PATCH, ALTER AND REFINISH
EXISTING CONSTRUCTION AS REQUIRED TO
LEAVE WORK COMPLETE AND IN SAT15FACTORY
MANNER
5. CONTRACTOR 15 TO PROTECT ALL UNDER- 8.
GROUND OR OTHER CONCEALED UTILITIES HE 15
TO INSPECT CEILING AND CHASES TO ASSURE
PROPER IDENTIFICATION OF UTILITIES,
MECHANICAL AND /OR ELECTRICAL
CONTRACTOR ARE TO CAP THEM AS REQUIRED.
S.
(a. OPENINGS LEFT THROUGH RATED AND SMOKE
PARTITIONS DUE TO REMOVAL OF DUCTWORK
CONDUIT SHALL BE CLOSED (BOTH SIDES)
AS PER A.H.C.A. PENETRATION DETAILS.
1. REMOVE ALL EXISTING ACOUSTICAL TILE CLG.
AND SUSPENDED SYSTEMS IN THE
RENOVATION AREA AS REQUIRED FOR
INSTALLATION OF WORK TO BE DONE.
COORDINATE REMOVAL WITH ELECTRICAL
CONTRACTOR REGARDING EXISTING LIGHTING
FIXTURES ETC - REPLACE CEILING
ACCORDINGLY AFTER COMPLETING OF WORK.
GENERAL DEMOLITION NOTES:
DEMOLITION 15 DENOTED BY BROKEN
CONTRACTOR 15 TO SAW -CUT ALL OPENINGS IN
10_ CONTRACTOR 15 TO COORDINATE
CONCRETE BLOCK WALLS IF REQUIRED,
DEMOLITION WORK WITH ADMINISTRATION AND
CONTRACTOR SHALL NOT DEMOLISH OPENINGS
15 TO GIVE SUFFICIENT ADVANCE NOTICE OF
WITH SLEDGE HAMMER UNTIL OUTLINES HAVE
THE BEGINNING OF WORK IN EACH EXISTING
BEEN CUT.
FLOOR TO ADMINISTRATION (12 HOUR
NEW COI ICRETE: COLUMN
MINIMUM)
RENOVATION WORK MAY ENTAIL INTERVENTIONS
EXISTING CONC. COLUMN
IN AREAS OUTSIDE OF THE IMMEDIATE SCOPE OF
11. CONTRACTOR SHALL VERIFY EXACT LOCATION
WORK, INCLUDING WORK ABOVE AND /OR BELOW
OF EXISTING CONCRETE COLUMNS IN AREAS
THE FLOOR LEVEL WITHIN THE SCOPE. IT MAY
WHERE WALLS ARE BEING REMOVED AND
REQUIRE WORK INVOLVING REMOTE UTILITY
INFORM ARCHITECT OF ANY CONFLICTS
LINES (ELECTRICAL MECHANICAL, PLUMBING,
BEFORE ANY WALLS ARE REMOVED SO THAT
COMMUNICATIONS). ANY WORK IN AREAS
A/E CAN INSPECT THEM FOR CLARIFICATION
OUTSIDE OF THE IMMEDIATE SCOPE OF WORK
PRIOR TO PROCEEDING WITH WORK..
SHALL BE ALL - INCLUSIVE, PROVIDING ALL
REQUIRED TO RECEIVE NEW SCHEDULED
-STRUCTURES, UTILITIES, FINISHES AND EQUIP.
REQUIRED TO RESTORE THE AREA TO FULLY
12. PATCH AND REPAIR ALL EXISTING SURFACES
OPERATIONAL CONDITIONS, TO FULLY
DAMAGED BY DEMOLITION AND /OR
COMPLYING RATING INTEGRITY, AND TO MEET
INSTALLATION OF NEW ELECTRICAL CONDUITS,
OWNER'S APPROVAL ALL WORK AS DESCRIBED
GAS PIPING, ETC- AS REQUIRED TO MATCH
IN THI5 NOTE 15 TO BE PART OF THE BASE
ADJACENT SURFACES AND /OR AS REQUIRED
CONTRACT PRICE, OR CONTRACT CONTINGENCY
FOR NEW SCHEDULED FINISHES.
ALLOWANCE FOR SUCH WORK.
THAT THERE WILL BE NO ADDITIONAL COST TO OWNER
13,
DEMOLITION 15 DENOTED BY BROKEN
18, CONTRACTOR TO SURVEY PROJECT AREA
EXI3TINcs RE'NFOfh,N ED C04C.
LINES,
PRIOR TO COMMENCEMENT OF WORK. NOTE
14.
FOR REMOVAL OF FIXTURES AND EQUIPMENT
AND REPAIR ANY DAMAGE TO AREAS
TO REMAIN
SEE ARCHITECTURAL, PLUMBING, MECHANICAL
WHERE WORK 15 GOING TO BE PER!FORMED_
NEW COI ICRETE: COLUMN
AND ELECTRICAL DRAWINGS.
NOTIFY OWNER AND ARCHITECT WITH A LIST
EXISTING CONC. COLUMN
OF WORK PRIOR TO CONTRACT.
(5.
PREPARE EXISTING CONCRETE SLAB AS REQ.
NEW :ONCRETE WALL'
BY GRINDING, LEVELING WITH ARDEX LEVELER
19
EXISTING WALL OR ^ .^
AS PER MANUFACTURERS SPECIFICATIONS.
THIS SET OF DRAWINGS 15 TO BE USED AS A UNIT.
MATCH EXISTING SLAB ELEVATION AS
CONTRACTOR 15 RESPONSIBLE FOR ALL DISCIPLINES,
REQUIRED TO RECEIVE NEW SCHEDULED
< SHOULD INCLUDE EVERYTHING THAT 15 NEEDED FOR
FLOORING MATERIAL.
MAKING ALL SYSTEMS WORK EXAMPLE: IF A SINK 15
--
- - - ---
SHOWN IN THE ARCHITECTURAL PLANS, IT IS ASSUMED
Iro.
VERIFY WITH CIVIL, PLUMBING, MECHANICAL
THAT THE G.C. IS PROVIDING EVERYTHING NEEDED,
AND ELECTRICAL DRAWINGS ITEMS TO BE
A/E WILL PROVIDE THEM WITH THE UNDERSTANDING
REMOVED /RELOCATED IN CASE OF
THAT THERE WILL BE NO ADDITIONAL COST TO OWNER
CONFLICT.
EXISTING DOOR TO BE REMOVED
I-I.
DESTINATION OF ALL EXISTING EQUIPMENT,
20. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL
PLUMBING FIXTURES, DOORS AND FRAMES, ETC.
INFORMATION REGARDING PARTIAL DEMOLITION,
TO BE REMOVED SHALL BE COORDINATED
INCLUDING BUT NOT LIMITED TO CMU CELL
pENOTES PORTION OF EXISTING
WITH THE OWNER
REINFORCEMENT
EXISTING CONCRETE STAIR F�D
AND ENCLOSURE TO
REMAIN
EXISTING CONCRETE
COLUMN TO REMAIN (TYP.)
eff
I°
T,
♦ 05
, A F QMMO
� In
Revisions:
a
A
A
0
d
W if
Z ��
wr
z
Wu�
Z �
ad
U
z
�<
a j
a
w Z
as
z
a
a
A
PERMIT SET
0
Sheet No.
A -2
OF
29
EXI3TINcs RE'NFOfh,N ED C04C.
COLUMN OR CONCRETE WALL
TO REMAIN
w
NEW COI ICRETE: COLUMN
EXISTING CONC. COLUMN
TO BE REMOVED
NEW :ONCRETE WALL'
EXISTING WALL OR ^ .^
PARTITION TO REMAIN
WALL OR PARTITION WITH
EXISTING DOOR TO REMAIN
--
- - - ---
EXISTING WALL OR
— —
— — — — —
PARTITION TO BE REMOVED
f
WALL OR PARTITION WITH
t
EXISTING DOOR TO BE REMOVED
==
DEMOLITION SYMBOL
(SEE DEMOLITION LEGEND)
pENOTES PORTION OF EXISTING
CONCRETE SLAB AND /OR JOISTS
TO BE REMOVED. SEE 5TRUCTURAL
DEMOLITION NOTES.
(D r,1
REMOVE EXISTING DOOR AND FRAME.
SEE DETAIL - - - - - -- SHEET A- - - - - - -'
REMOVE EXISTING PARTITION WALL
AS REQUIRED. ALL INTERIOR PARTITIONS AND
FURRING TO BE REMOVED. (TYP)
REMOVE PLUMBING FIXTURES AND CAP
3
ALL PLUMBING LINES ABOVE CEILING OR WITHIN
WALL AS REQUIRED.
(SEE ENGINEERING DRAWINGS)
REMOVE EXISTING FLOOR FINISH
`}
AS REQUIRED. PATCH AND LEVEL TO
RECEIVE NEW FINISH FLOOR
REMOVE EXISTING CANVAS CANOPY.'' "'
5
PATCH AND FINISH TO MATCH EXISTING
SEE NEW ARCH. AND STRUCT. DRAWINGS
FOR NEW CANOPY LOCATION.
REMOVE EX15TING CONCRETE SLAB
SAW CUT EXISTING SLAB TO PROVIDE
ACCESS UNDERGROUND FOR THE
INSTALLATION OF THE DRAINAGE LINES.
SEE PLUMBING DRAWINGS FOR
COORDINATION
EXISTING RAILING AT STAIR
QREMOVE
LOCATIONS.
NEW
aPROVIDE
MASONRY OPENING (SEE
DOOR SCHEDULE FOR SIZE).
REMOVE EXISTING CONC. 5LAB AS
im
REQUIRED FOR NEW GONG. FOOTING.
(SEE - STRUCTURAL DRAWINGS FOR SIZE)
PROVIDE NEW WALL. SEE WALL TYPE
Ii
SHEET.
REMOVE EXISTING: SOFFIT.
REMOVE ALL EXISTING FINISHES, INCLUDING
CEILING TILES, GRID, SUPPORT SYSTEM,
SOFFITS AND FLOORING.
REMOVE EXISTING ELECTRICAL OUTLETS,
SWITCHES, LIGHT FIXTURES AND DEVICES.
(SEE ENGINEERING DRAWINGS)
OREMOVE
EXISTING STRUCTURAL BEAM
Ih
NEW PLUMBING FIXTURES (TYPICAL).
REMOVE EX15TING STUCCO BAND
17
ON EXTERIOR ELEVATIONS.
SEE EXTERIOR ELEVATIONS SHEET._
EXISTING BLOCK WALL
OREMOVE
AS SHOWN.
REMOVE EXISTING PORTION OF BLOCK
WALL AS INDICATED.
Zm
REMOVE EXISTING WINDOW /STOREFRONT
REMOVE EXISTING WINDOW
REMOVE EX15TING A /C.
2i
SEE MEP DRAWINGS.
�2
REFER TO SITE PLAN FOR
SCOPE OF DEMOLITION WORK AT SITE.
EXISTING METAL SHED.
OREMOVE
Z3
REFER TO SITE DEMOLITION PLAN
Z4
REMOVE EXISTING CABINET. CITY OF E UT
no nimr,
I°
T,
♦ 05
, A F QMMO
� In
Revisions:
a
A
A
0
d
W if
Z ��
wr
z
Wu�
Z �
ad
U
z
�<
a j
a
w Z
as
z
a
a
A
PERMIT SET
0
Sheet No.
A -2
OF
29