Loading...
11-556-004EXISTING 4' HT. WALL TO BE DEMOLISHED4 REFER TO SITE PLAN FOR EXACT —C€N� y GENERAL DEMOLITION NOTES. 1. THIS DRAWING IS ONLY TO ASSIST IN SHOWING THE SCOPE OF DEMOLITION WORK AND 15 NOT INTENDED TO INDICATE ALL DEMOLITION. CONTRACTOR SHALL REMOVE ALL EXISTING ITEMS AS REQUIRED TO COMPLETE THE JOB. 2. NOT ALL ITEMS TO BE DEMOLISHED ARE SHOWN ON THE PLAN. CONTRACTOR SHALL BE RESPONSIBLE FOR PERFORMING A WALK -THRU OF THE PROJECT PRIOR TO SUBMITTING A BID TO THE OWNER FOR IDENTIFYING POSSIBLE CRITICAL ITEMS, NOT OR INCORRECTLY ADDRESSED, WHICH REQUIRE REMOVAL / RELOCATION. 3. PROVIDE SAFETY FEATURES DURING WORK AS CALLED FOR IN SPECS, APPLICABLE CODES, RULES AND REGULATIONS HAVING JURISDICTION OF THE PROJECT. 4. CUT, REMOVE, PATCH, ALTER AND REFINISH EXISTING CONSTRUCTION AS REQUIRED TO LEAVE WORK COMPLETE AND IN SATISFACTORY MANNER 5. CONTRACTOR IS TO PROTECT ALL UNDER- GROUND OR OTHER CONCEALED UTILITIES HE 19 TO INSPECT CEILING AND CHASES TO ASSURE PROPER IDENTIFICATION OF UTILITIES. MECHANICAL AND /OR ELECTRICAL CONTRACTOR ARE TO CAP THEM AS REQUIRED, ro. OPENINGS LEFT THROUGH RATED AND SMOKE PARTITIONS DUE TO REMOVAL OF DUCTWORK CONDUIT SHALL BE CLOSED (BOTH SIDES) AS PER A.H.C.A. PENETRATION DETAILS, I. REMOVE ALL EX15TING ACOUSTICAL TILE CLG. AND SUSPENDED SYSTEMS IN THE RENOVATION AREA AS REQUIRED FOR INSTALLATION OF WORK TO BE DONE, COORDINATE REMOVAL WITH ELECTRICAL CONTRACTOR REGARDING EXISTING LIGHTING FIXTURES ETC- REPLACE CEILING ACCORDINGLY AFTER COMPLETING OF WORK. 8. CONTRACTOR 15 TO SAW -GUT ALL OPENINGS IN CONCRETE BLOCK WALLS IF REQUIRED. CONTRACTOR SHALL NOT DEMOLISH OPENINGS WITH SLEDGE HAMMER UNTIL OUTLINES HAVE BEEN CUT. 3. RENOVATION WORK MAY ENTAIL INTERVENTIONS IN AREAS OUTSIDE OF THE IMMEDIATE SCOPE OF WORK, INCLUDING WORK ABOVE AND /OR BELOW THE FLOOR LEVEL WITHIN THE SCOPE. IT MAY REQUIRE WORK INVOLVING REMOTE UTILITY LINES (ELECTRICAL MECHANICAL, PLUMBING, COMMUNICATIONS). ANY WORK IN AREAS OUTSIDE OF THE IMMEDIATE SCOPE OF WORK SHALL BE ALL - INCLUSIVE, PROVIDING ALL STRUCTURES, UTILITIES, FINISHES AND EQUIP. REQUIRED TO RESTORE THE AREA TO FULLY OPERATIONAL CONDITIONS, TO FULLY COMPLYING RATING INTEGRITY, AND TO MEET OWNER'S APPROVAL ALL WORK AS DESCRIBED IN THIS NOTE 15 TO BE PART OF THE BASE CONTRACT PRICE, OR CONTRACT CONTINGENCY ALLOWANCE FOR SUCH WORK, 10. CONTRACTOR IS TO COORDINATE DEMOLITION WORK, WITH ADMINISTRATION AND 15 TO GIVE SUFFICIENT ADVANCE NOTICE OF THE BEGINNING OF WORK IN EACH EXISTING FLOOR TO ADMINISTRATION (12 HOUR MINIMUM) 11. CONTRACTOR SHALL VERIFY EXACT LOCATION OF EXISTING CONCRETE COLUMNS IN AREAS WHERE WALLS ARE BEING REMOVED AND INFORM ARCHITECT OF ANY CONFLICTS BEFORE ANY WALLS ARE REMOVED SO THAT A/E CAN INSPECT THEM FOR CLARIFICATION PRIOR TO PROCEEDING WITH WORK 12. PATCH AND REPAIR ALL EXISTING SURFACES DAMAGED BY DEMOLITION AND /OR INSTALLATION OF NEW ELECTRICAL CONDUITS, GAS PIPING, ETC- AS REQUIRED TO MATCH ADJACENT SURFACES AND /OR AS REQUIRED FOR NEW SCHEDULED FINISHES. 13. DEMOLITION IS DENOTED BY BROKEN LINES. 14. FOR REMOVAL OF FIXTURES AND EQUIPMENT SEE ARCHITECTURAL, PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS. 15. PREPARE EXISTING CONCRETE SLAB AS REQ. BY GRINDING, LEVELING WITH ARDEX LEVELER AS PER MANUFACTURERS SPECIFICATIONS. MATCH EXISTING SLAB ELEVATION AS REQUIRED TO RECEIVE NEW SCHEDULED FLOORING MATERIAL. 16. VERIFY WITH CIVIL, PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS ITEMS TO BE REMOVED /RELOCATED IN CASE OF CONFLICT. 11. DESTINATION OF ALL EXISTING EQUIPMENT, PLUMBING FIXTURES, DOORS AND FRAMES, ETC. TO BE REMOVED SHALL BE COORDINATED WITH THE OWNER E , t( 1 g I INSTALL NEW 12' DEEP CONC. SLAB W/3000 PSI. CONC. W/* 19 5'5 m 12 O.C, E.A. WAY ON 10 t MIL. VAPOR BARRIER ON WELL COMPACTED FILL -- WITHIN AREA INDICATED. 0' 1- 10' -6' i I_ 18. CONTRACTOR TO SURVEY PROJECT AREA PRIOR TO COMMENCEMENT OF WORK. NOTE AND REPAIR ANY DAMAGE TO AREAS WHERE WORK 15 GOING TO BE PERFORMED. NOTIFY OWNER AND ARCHITECT WITH A LIST OF WORK PRIOR TO CONTRACT. 13• THIS SET OF DRAWINGS 15 TO BE USED AS A UNIT. CONTRACTOR 15 RESPONSIBLE FOR ALL DISCIPLINES, 4 SHOULD INCLUDE EVERYTHING THAT 15 NEEDED FOR MAKING ALL SYSTEMS WORK. EXAMPLE. IF A SINK IS SHOWN IN THE ARCHITECTURAL PLANS, IT IS ASSUMED THAT THE G.C. IS PROVIDING EVERYTHING NEEDED, A/E WILL PROVIDE THEM WITH THE UNDERSTANDING THAT THERE WILL BE NO ADDITIONAL COST TO OWNER 20. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION REGARDING PARTIAL DEMOLITION, INCLUDING BUT NOT LIMITED TO CMU CELL REINFORCEMENT DENOTES EXISTING FOUNDATION. r`N /� 0 EXISTING CONCRETE STAIR AND ENCLOSURE TO REMAIN CONTRACTOR SHALL SAW GUT AND — REMOVE EXISTING CONC. SLAB WITHIN At l- A Mfte l/ ATP"e^a • Pv. i/±T At 1 ttrva/ t'1R DEEP CONC. SLAB W/3000 PSI. GONG. W/* 5'S m 12 O.C. EXISTING CONCRETE COLUMN TO REMAIN (TYPP.) CONTRACTOR SHALL SAW CUT AND REMOVE EXISTING CONC. SLAB WITHIN AREA INDICATED 4 INSTALL NEW 12' DEEP CONC. SLAB W13000 PSI. CONC. W/* 5'5 m 12 O.G. % TE SCALE: 1/4' = V-0" Coin W LU OL Za QL O I-Aps", 9 IN 11 � PM. ME _ R M DEMOLITION FLAN LEGEND_ _ EXISTING REINFORCED CONC. w COLUMN OR CONCRETE WALL TO REMAIN NEW CONCRETE COLUMN ® EXISTING CONC. COLUMN m TO BE REMOVED h NEW CONCRETE WALL EXISTING WALL OR PARTITION TO REMAIN WALL OR PARTITION WITH EXISTING DOOR TO REMAIN EXISTING WALL OR PARTITION TO BE REMOVED WALL OR PARTITION WITH EXISTING DOOR TO BE REMOVED �.� DEMOLITION SYMBOL ��ISy (SEE DEMOLITION LEGEND) DENOTES PORTION OF EXISTING CONCRETE SLAB AND /OR JOISTS TO BE REMOVED. SEE STRUCTURAL DEMOLITION NOTE ,5: REMOVE EXISTING DOOR AND FRAME. SEE DETAIL - - - - - -- SHEET A- - - - - -- REMOVE EXISTING PARTITION WALL AS REQUIRED. ALL INTERIOR PARTITIONS AND FURRING TO BE REMOVED. (TYP) REMOVE PLUMBING FIXTURES AND CAP ALL PLUMBING LINES ABOVE CEILING OR WITHIN WALL AS REQUIRED. (SEE ENGINEERING DRAWINGS) REMOVE EXISTING FLOOR FINISH 't AS REQUIRED. PATCH AND LEVEL TO RECEIVE NEW FINISH FLOOR EXISTING CANVAS ON CANOPY FRAME. OREMOVE 5 CANVAS TO MATCH COLOR OF NEW ENTRY CANOPY. REMOVE EXISTING CONCRETE SLOB SAW CUT EXISTING SLAB TO PROVIDE �J ACCESS UNDERGROUND FOR THE INSTALLATION OF THE DRAINAGE LINES. SEE PLUMBING DRAWINGS FOR COORDINATION. l @'\ REMOVE EXISTING RAILING AT STAIR °f LOCATIONS. PROVIDE NEW 9 MASONRY OPENING (SEE DOOR SCHEDULE FOR SIZE). EXISTING CONC. SLAB AS OREMOVE REQUIRED FOR NEW CONC. FOOTING. (SEE - STRUCTURAL DRAWINGS FOR SIZE) PROVIDE NEW WALL. SEE WALL TYPE 11 SHEET. REMOVE EXISTING SOFFIT. REMOVE ALL EXISTING FINISHES] INCLUDING 13 CEILING TILES, GRID, SUPPORT SYSTEM, SOFFITS AND FLOORING. REMOVE EXISTING ELECTRICAL OUTLETS, SWITCHES, LIGHT FIXTURES AND DEVICES. (SEE ENGINEERING DRAWINGS) t8 REMOVE EXISTING STRUCTURAL BEAM 1 NEW PLUMBING FIXTURES CTYPIGAL). I REMOVE EXISTING STUCCO BAND h ON EXTERIOR ELEVATIONS. SEE EXTERIOR ELEVATIONS SHEET. REMOVE EXISTING BLOCK WALL AS SHOWN. REMOVE EXISTING PORTION OF BLOCK 19 WALL AS INDICATED. j 20 REMOVE EXISTING WINDOW /STOREFRONT REMOVE EXISTING WIN y FI T MIAMI BUILDING EPT. REMOVE EXISTING A/C. I 2t SEE MEP DRAWINGS. STRUCI 11FAL Sm, TE N 22 NOT USED. ,l- ;JR01E Y: _ 23 NOT USED. I Z, it I 2_ 24 REMOVE EXISTING CABINET. Re,Aaion& ZL//�` �ai1310�1 *1 ry BLDG. DEPT. Gil . W H 0 w� z u z�� a� U a mem z o� 4 z w a �O LA.. Ii. W Q PERMIT SET DRAB RR 4 NM CkffjCKEDs LEN DATE: Oro-01-2011 SCALE- AS SHOWN SEAL Sheet No. A -] OF 29 JOB # 201115