14-1091-0061. THE DESIGN, INSTALLATION, MAINTENANCE, ALTERATION, AND INSPECTION OF
MECHANICAL SYSTEMS SHALL BE REGULATED BY THE 2010 FLORIDA BUILDING CODE -
RESIDENTIAL. EXISTING MECHANICAL SYSTEMS SHALL BE REGULATED BY THE 2010
FLORIDA BUILDING CODE - EXISTING BUILDING.
2. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, PERMITS,
FEES INSPECTIONS, TESTS, INSURANCE, ETC. REQUIRED FOR THE COMPLETION OF
THE AIR CONDITIONING SYSTEM SHOWN ON THE DRAWINGS AND/ OR LISTED BELOW.
3. VENTILATION DUCTWORK SHALL BE GALVANIZED STEEL WITH GAUGES, DUCT
CONSTRUCTION, BRACING AND SUSPENSION IN ACCORDANCE WITH THE
RECOMMENDATIONS SET FORTH IN THE LATEST EDITION OF THE A.S.H.R.A.E. GUIDE
AND S.M.A.C.N.A. STANDARDS. DUCT SIZES SHOWN ARE "INSIDE" DIMENSIONS. VERIFY
EXACT LOCATION OF DUCT WITH RESPECT TO STRUCTURE BEFORE FABRICATION.
4. FLEXIBLE DUCT SHALL BE STEEL HELIX WIRE ON 7/8" CENTERS, ENCAPSULATED IN A
CONTINUOUS SOFT VINYL FILM, JOINED BY MOLECULAR WELDING TO FORM AN AIR
TIGHT INNER CORE, THE CORE IS TO BE INSULATED WITH FIBERGLASS INSULATION
(R-6), AND SHEATHED IN A REINFORCED, ALUMINUM METALIZED POLYESTER VAPOR
BARRIER JACKET. PROVIDE SPIN COLLAR WITH DAMPER AND EXTRACTOR WHERE
FLEXIBLE DUCT IS CONNECTED TO RECTANGULAR DUCTWORK. DAMPER ACTUATOR
SHALL BE EXTENDED OUTSIDE INSULATION,
5. AIR CONDITIONING SUPPLY AND RETURN DUCTWORK RUNNING IN ATTIC SPACE SHALL
BE 1 -1/2" (R =6 MIN.) FIBERGLASS U.L. 181 LISTED, CLASS I AIR DUCT. DUCTWORK SHALL
BE FABRICATED IN ACCORDANCE WITH S.M.A.C.N.A. STANDARDS. DUCTWORK SHALL BE
FACED ON ONE SIDE WITH A FIRE - RESISTANT FOIL -SCRIM -KRAFT (FSK) VAPOR
RETARDER, AND ITS AIRSTREAM SURFACE SHALL BE FACED WITH A TIGHTLY BONDED
NON -WOVEN MAT. AIRSTREAM SURFACE MAT FACING SHALL BE TREATED WITH AN
EPA - REGISTERED ANTI - MICROBIAL AGENT TO AID IN THE PREVENTION OF FUNGAL AND
BACTERIAL GROWTH.
6. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE
WITH THE PROGRESS OF CONSTRUCTION AND IN STRICT COMPLIANCE WITH ALL
APPLICABLE CODES AND STANDARDS.
7. SUBMIT SHOP DRAWING OF ALL MATERIALS AND EQUIPMENT FOR APPROVAL PRIOR TO
FABRICATION.
8. OBTAIN FULL INFORMATION REGARDING PECULIARITIES AND LIMITATIONS OF SPACE
AVAILABLE FOR INSTALLATION OF THE EQUIPMENT AND MATERIALS UNDER CONTRACT
AND PROVIDE READY ACCESSIBILITY TO DAMPERS, VALVES AND OTHER APPARATUS,
INCLUDING ANY PART OF SYSTEM REQUIRED TO BE REACHED FOR MAINTENANCE AND
OPERATIONS.
9. CUT ALL OPENINGS AND CHASES REQUIRED TO ACCOMMODATE THE WORK UNDER
THIS DIVISION, AND REPAIR ALL FLOORS, WALLS, ETC., DAMAGED BY SUCH CUTTINGS.
ALL WORK DONE UNDER THIS HEADING MUST CONFORM IN EVERY RESPECT TO FINISH
AND QUALITY OF MATERIALS AND WORKMANSHIP SPECIFIED UNDER APPROPRIATE
SECTIONS FOR THE BUILDING.
10. TEMPERATURE CONTROL SHALL BE A ROOM THERMOSTAT FOR HEATING /COOLING
WITH STAGES AS REQUIRED.
11. VIBRATION ISOLATION: ALL EQUIPMENT AS PER MANUFACTURER RECOMMENDATIONS
TO ELIMINATE ANY EQUIPMENT NOISE FROM BEING HEARD.
12. GUARANTEES:
A. ALL COMPRESSOR MOTORS ON NEW EQUIPMENT FURNISHED UNDER THIS
CONTRACT SHALL HAVE A MIN. 5 YEARS PRODUCT GUARANTEE FROM DATE OF
START -UP.
B. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE
FROM DEFECTS FOR A PERIOD OF NOT LESS THAN A 1 YEAR FROM DATE OF
ACCEPTANCE.
13. TESTING:
A. ALL REFRIGERANT HIGH SIDE PIPING TO 300 PSIG. LOW SIDE TO 150 PSIG.
AFTER TESTING, EVACUATE SYSTEM TO 28% MERCURY GAUGE PRESSURE WITH
VACUUM PUMP. HOLD FOR 25 HOURS WITH PUMP OFF. BREAK VACUUM WITH
REFRIGERANT.
14, ALL CONDENSATE PIPING SHALL BE PVC SCHEDULE 40. INSULATE COND. PIPES ABOVE
GROUND WITH 1/2 INCH ARMAFLEX INSULATION.
15. ALL CONDENSING UNITS AND AIR HANDLING UNITS SHALL BE MOUNTED ABOVE FLOOD
CRITERIA,
16. COMPLIANCE REQUIRES AN AIR DISTRIBUTION SYSTEM TEST REPORT, BY A FLORIDA
CLASS 1 RATER, CONFIRMING DISTRIBUTION SYSTEM AIR LEAKAGE TO OUTDOORS NO
GREATER THAN 3 CFM PER 100 SQFT OF CONDITIONED FLOOR AREA AT PRESSURE
DIFFERENCE OF 25 PASCAL IN ACCORDANCE WITH N1110.A.2.
METAL ROUND FITTING
QUADRANT OPERATOR
TO BE OUTSIDE INSULATION
PROVIDE INSULATION GUARD
WHERE NECESSARY
PROVIDE FIBERGLASS
INSULATION SEAL TO
NECK & PERIMETER OF
DIFFUSER
DIFFUSER OR
REGISTER
SEAL. JOINT WITH
DUCT SEALER
AND TAPE -
FLOW \ \\
IU7
k n
R-6 MIN. INSULATION
INSULATED FLEX. DUCT
R-6 MIN. INSULATION
SEAL JOINT WITH
DUCT SEALER
AND TAPE
`-- R-6 MIN.
INSULATION
FLEXIBLE DUCT CONNECTION DETAIL
N.T.S.
EXISTING ROOF
STRUCTURE AND
FINISH
4 -16D NAILS —
THRU PLYWOOD
SHEATHING,
SEAL ALL NAIL
HEADS WITH
ROOF CEMENT
4" 0 26 GAUGE
GALVANIZED STEEL
DUCT. DUCT SHALL BE
FABRICATED IN
ACCORDANCE WITH
FLORIDA BUILDING
CODE RESIDENTIAL,
M1601.1 AND ACCA
MANUAL D
CEILING MOUNTED
EXHAUST FAN, SEE
EXHAUST FAN '-
SPECIFICATION
GALVANIZED STEEL ROOF CAP
WITH BUILT -IN BACKDRAFT
DAMPER AND BIRD SCREEN.
INSTALL PER ROOF CAP
MANUFACTURER'S AND ROOFING
SYSTEM MANUFACTURER'S
SPECIFICATIONS.
7
�o t4
cy
GENERAL NOTE:
STRUCTURAL MEMBERS
UNLESS APPROVED AND
DETAILED BY THE ARCHITECT
OF RECORD
WALL
d-/
50 ELBOW &
CAP ASSEMBLY
TYPICAL ROOF CAP DETAIL
TOILET EXH.
NTs
i i i • i
SCALE: 1/4 V -0°
ED EXHAUST FAN SPECIFICATION
_:499
VENTILATION FAN SHALL BE MODEL NUMBER RN110 AS MANUFACTURED BY NUTONE
ACCORDING TO LISTED SPECIFICATIONS. UNIT SHALL DELIVER 110 CFM AT A SOUND LEVEL
OF 0.6 SONES. FAN SHALL HAVE CORROSION RESISTANT GALVANIZED STEEL HOUSING WITH
FOUR -POINT MOUNTING CAPABILITY. FAN SHALL BE DUCTED TO ROOF CAP USING 41' ROUND
DUCTWORK. NON - METALLIC DAMPER /DUCT CONNECTOR SHALL BE INCLUDED. BLOWER
ASSEMBLY SHALL BE REMOVABLE, HAVE CENTRIFUGAL -TYPE BLOWER WHEEL AND A
PERMANENTLY LUBRICATED MOTOR DESIGNED FOR CONTINUOUS OPERATION & MOUNTED
WITH RESILIENT ANTI-VIBRATION MOUNTS.
CLASSIFICATION OF WORK
1. ALTERATION -LEVEL 2
SCOPE OF WORK
1. EXHAUST FAN AS REQUIRED FOR PROPOSED ALTERED MASTER BATH
2. SUPPLY AIR AS REQUIRED FOR PROPOSED ALTERED MASTER BATH
ea •RRl,. •y
t
AMILCAR R. MELENDE�1
FLORIDA REGISTRATION AR93063 /
nl
of
a I"GII ttect, RK
1001 SW 67 AVE, STE 102, Miami, FL 33144
TEL.: +1 305 894 6605 FAX.: +1 786 347 7692
INFO @ARM- ARCHITECT.COM
DE CARDENAS RESIDENCE
project name. `
6120 TWIN LAKES DR.
SOUTH MIAMI, FL
FOLIO #09- 4025 -040 -0570
project address.
0 2014 ARM ARCHITECT, P.A.